HomeMy WebLinkAbout2022-11-02 PacketPage 1 of 6
City Council
Regular Meeting
AGENDA
(to be held both at the physical and virtual locations below)
Civic Center Council Chamber ♦ 300 Seminary Avenue ♦ Ukiah, CA 95482
To participate or view the virtual meeting, go to the following link: https://zoom.us/j/97199426600
Or you can call in using your telephone only:
Call (toll free) 1-888-788-0099
Enter the Access Code: 971 9942 6600
To Raise Hand enter *9
To Speak after being recognized: enter *6 to unmute yourself
Or One tap mobile (for easy connection on smart phones):
US: +16699009128,,97199426600# or +12532158782,,97199426600#
Alternatively, you may view the meeting (without participating) by clicking on the name of the meeting at
www.cityofukiah.com/meetings.
November 2, 2022 - 6:00 PM
1. ROLL CALL
2. PLEDGE OF ALLEGIANCE
3. PROCLAMATIONS/INTRODUCTIONS/PRESENTATIONS
3.a. Presentation of the 2022 Ukiah Leadership Academy Graduates.
Recommended Action: Receive presentation regarding the 2022 Ukiah Leadership Academy
graduates.
Attachments:
1. 2022 Ukiah Leadership Academy
4. PETITIONS AND COMMUNICATIONS
5. APPROVAL OF MINUTES
5.a. Approval of the Minutes for the October 19, 2022, Special Meeting.
Recommended Action: Approve the Minutes for the October 19, 2022, Special Meeting.
Attachments:
1. 2022-10-05 Draft Minutes - Special Meeting
Page 1 of 390
Page 2 of 6
5.b. Approval of the Minutes for the October 19, 2022, Regular Meeting.
Recommended Action: Approve the Minutes for the October 19, 2022, Regular Meeting.
Attachments:
1. 2022-10-19 Draft Minutes - Regular Meeting
6. RIGHT TO APPEAL DECISION
Persons who are dissatisfied with a decision of the City Council may have the right to a review of that decision by a court. The
City has adopted Section 1094.6 of the California Code of Civil Procedure, which generally limits to ninety days (90) the time
within which the decision of the City Boards and Agencies may be judicially challenged.
7. CONSENT CALENDAR
The following items listed are considered routine and will be enacted by a single motion and roll call vote by the City Council.
Items may be removed from the Consent Calendar upon request of a Councilmember or a citizen in which event the item will
be considered at the completion of all other items on the agenda. The motion by the City Council on the Consent Calendar will
approve and make findings in accordance with Administrative Staff and/or Planning Commission recommendations.
7.a. Adoption of Resolution Approving the City's Participation in the State's Clean Fuel Reward
Program Authorizing the City Manager to Execute the Participating Electric Utility Joinder to the
Clean Fuel Reward Program Governance Agreement; and Approval of the Northern California
Power Agency as the City's Authorized Initial Representative on the Clean Fuel Reward
Program Steering Committee.
Recommended Action: Adopt Resolution approving the City's participation in the State's Clean
Fuel Reward Program and authorizing the City Manager to execute the participating Electric
Utility Joinder to the Clean Fuel Reward Program Governance Agreement; and approve Northern
California Power Agency as the City's authorized initial representative on the Clean Fuel Reward
Program Steering Committee.
Attachments:
1. FINAL_CFR Governance Agreement.March 3.2020 with Large EDU Signatures
2. Joinder Agreement
3. Joinder Governance Agreement Resolution
7.b. Authorization for the City Manager to Execute a Construction Administration Services
Agreement with Mead and Hunt, Inc. for Runway 15-33 Pavement Rehabilitation Phase 2
Construction Continguent on Approval from the FAA, and Approve Corresponding Budget
Amendment.
Recommended Action: Authorize the City Manager to Execute a Construction Administration
Services Agreement with Mead and Hunt Inc. for Runway 15-33 Pavement Rehabilitation Phase 2
Construction contingent upon the FAA's approval of costs, and approve corresponding budget
amendment.
Attachments:
1. Mead & Hunt Contract
2. Independent Fee Estimate
7.c. Consideration of Approval of a Budget Amendment for the Ukiah Valley Fire Authority (UVFA)
Supplies and Maintenance Accounts.
Recommended Action: Approve amending the budget for an increase of $7,715 for the Ukiah
Valley Fire Authority (UVFA) building maintenance account and $3,100 for the Ambulance
supplies account for residual expenditures meant to be incurred in FY 2021-22.
Attachments: None
7.d. Review Landfill Closure Financial Plan Update.
Recommended Action: Receive and file update to the Landfill Closure Financial Plan.
Attachments:
1. Resolution No. 2016-03 - Establishing Funding Closure-Ukiah Solid Waste Disposal
Page 2 of 390
Page 3 of 6
2. Signed Landfill Inflation Form
7.e. Approval of Notice of Completion for Wahlund Construction Inc. for the Ford and Orchard Lift
Station Replacement, Specification 22-02, and Direct the City Clerk to File the Notice of
Completion with the County Recorder.
Recommended Action: Approve Notice of Completion for the Ford and Orchard Lift Station
Replacement, Specification 22-02, and direct the City Clerk to file the Notice of Completion with
the County Recorder.
Attachments:
1. Approving Staff Report
2. Notice-of-Completion
7.f. Report of Additional Amount for New 2023 Ford F-150 (All Electric) Lighting Pro Series Crew
Cab, and Approve Corresponding Budget Amendment.
Recommended Action: Receive the report, and approve the requested budget amendment.
Attachments:
1. PO 47870
2. Updated Quote Redwwod Ford
7.g. Approval of a Second Contract Amendment with GHD Inc. for Professional Engineering Services
for a Future Water Storage Tank Siting Study and Analysis, in the Amount of $20,000.
Recommended Action: Approve a second contract amendment with GHD Inc. for professional
engineering services for a future water storage tank siting study and analysis, in the amount of
$20,000.
Attachments:
1. Contract No. 2021-112
2. Contract No. 2021-112-A1
3. 2022-08-04 Ukiah Tank Siting Study - GHD Proposal
7.h. Report of the Acquisition of Two Diesel-Powered Emergency Intertie Pumps From Pac Machine
Co. in the Amount of $294,083.25, and Approve Corresponding Budget Amendment.
Recommended Action: Council will receive a report of the acquisition of two diesel-powered
emergency intertie pumps from Pac Machine Co. in the amount of $294,083.25, and consider
approving a corresponding budget amendment.
Attachments:
1. Grant Authorization
2. PO 40111
7.i. Approval of Notice of Completion for EIDIM Group, Inc. for the Council Chambers AV
Replacement Project, Specification No. 20-09, and Direct the City Clerk to File the Notice of
Completion with the County Recorder, and Approve Budget Amendment.
Recommended Action: Approve Notice of Completion for EIDIM Group, Inc. for the Council
Chambers AV Replacement Project, Specification No. 20-09, direct the City Clerk to file the Notice
of Completion with the County Recorder, and approve budget amendment.
Attachments:
1. Spec 20-09 Council Chambers AV Replacement
2. Change Order #1 - Increase in contract days
3. Change Order #2 - Additional work - Revised
4. Change Order #3 - Additional control programming
5. Notice-of-Completion
8. AUDIENCE COMMENTS ON NON-AGENDA ITEMS
Page 3 of 390
Page 4 of 6
The City Council welcomes input from the audience. If there is a matter of business on the agenda that you are interested in,
you may address the Council when this matter is considered. If you wish to speak on a matter that is not on this agenda that is
within the subject matter jurisdiction of the City Council, you may do so at this time. In order for everyone to be heard, please
limit your comments to three (3) minutes per person and not more than ten (10) minutes per subject. The Brown Act
regulations do not allow action to be taken on audience comments in which the subject is not listed on the agenda.
9. COUNCIL REPORTS
10. CITY MANAGER/CITY CLERK REPORTS
11. PUBLIC HEARINGS (6:15 PM)
12. UNFINISHED BUSINESS
12.a. Consideration of Approval of Scope of Work for General Plan Mobility Subconsultant GHD to
Expand the City's SB 743 Methodology to Include Multimodal Networks; Approval of Contract
Amendment with Mintier Harnish, General Plan Consultants; and Approval of Corresponding
Budget Amendment.
Recommended Action: Approve scope of work for General Plan mobility subconsultant GHD to
expand the City's SB 743 methodology to include multimodal networks; contract amendment with
Mintier Harnish, General Plan consultants; and a corresponding budget amendment.
Attachments:
1. 9-21-22 13a Presentation Given at Meeting
2. Ukiah SB-743 Methodology-10.3.22 GHD memo
3. Ukiah SB-743 Mitigation Proposal_10.21.22
4. Amendment 3- C#1819190 (GHD SB 743)
13. NEW BUSINESS
13.a. Introduction of an Ordinance, by Title Only, to Adopt the 2022 California Fire Code as
Amended.
Recommended Action: Introduce the Ordinance, by title only, amending Division 6, Chapter 3,
Articles 1 and and 3, of the Ukiah City Code, entitled: Fire Prevention Code, to adopt the 2022
Edition of the California Fire Code, including additions or amendments, as well as NFPA 1
Chapter 38 thereto to address local conditions.
Attachments:
1. 2022 Fire Code Adoption Ordinance Redline
2. 2022 Fire Code Adoption Ordinance Clean
13.b. Receive Updates on City Council Committee and Ad Hoc Assignments, and, if Necessary,
Consider Modifications to Assignments and/or the Creation/Elimination of Ad Hoc(s); Including
Consideration of Adoption of Resolution Appointed a Member and an Alternate Member to the
Ukiah Valley Basin Groundwater Sustainability Agency (UVBGSA).
Recommended Action: 1. Receive report(s). The Council will consider modifications to
committee and ad hoc assignments along with the creation/elimination ad hoc(s).
2. Adopt Resolution appointing a Member and an Alternate Member to the Ukiah Valley Basin
Groundwater Sustainability Agency (UVBGSA).
Attachments:
1. 2022 City Council Special Assignments
2. Ukiah Valley Basin GSA JPA
Page 4 of 390
Page 5 of 6
3. UVBGSA Appointing Resolution 2022
14. CLOSED SESSION - CLOSED SESSION MAY BE HELD AT ANY TIME DURING THE MEETING
14.a. Conference with Legal Counsel – Anticipated Litigation
(Government Code Section 54956.9(d)(2))
Significant exposure to litigation pursuant to paragraph (2) of subdivision (d) of Section
54956.9: (2 cases)
14.b. Conference with Legal Counsel – Existing Litigation
(Government Code Section 54956.9(d)(1)
Name of case: Roofing & Solar Construction, Inc. v. City of Ukiah et al., Mendocino County
Superior Court Case No. 22CV00048
14.c. Conference with Legal Counsel – Existing Litigation
(Government Code Section 54956.9(d)(1))
Name of case: Vichy Springs Resort v. City of Ukiah, Et Al; Case No. SCUK-CVPT-2018-70200
14.d. Conference with Legal Counsel – Existing Litigation
(Government Code Section 54956.9(d)(1))
Name of case: Russian River Keepers et al. v. City of Ukiah, Case No. SCUK-CVPT-20-74612
14.e. Conference with Real Property Negotiators
(Cal. Gov't Code Section 54956.8)
Property: APN Nos: 003-190-11
Negotiator: Sage Sangiacomo, City Manager
Negotiating Parties: Dave Hull
Under Negotiation: Price & Terms of Payment
Recommended Action: None
Attachments: None
14.f. Conference with Real Property Negotiators
(Cal. Gov’t Code Section 54956.8)
Property: APN Nos: 003-260-01, 003-500-14
Negotiator: Sage Sangiacomo, City Manager;
Negotiating Parties: Eric Crane and Francine Selim
Under Negotiation: Price & Terms of Payment
14.g. Conference with Labor Negotiator (54957.6)
Agency Representative: Sage Sangiacomo, City Manager
Employee Organizations: All Bargaining Units
14.h. Public Employee Performance Evaluation
(Government Code Section 54956
Title: City Manager
15. ADJOURNMENT
Please be advised that the City needs to be notified 72 hours in advance of a meeting if any specific accommodations or interpreter services
are needed in order for you to attend. The City complies with ADA requirements and will attempt to reasonably accommodate individuals with
disabilities upon request. Materials related to an item on this Agenda submitted to the City Council after distribution of the agenda packet are
available for public inspection at the front counter at the Ukiah Civic Center, 300 Seminary Avenue, Ukiah, CA 95482, during normal business
hours, Monday through Friday, 8:00 am to 5:00 pm.
Page 5 of 390
Page 6 of 6
I hereby certify under penalty of perjury under the laws of the State of California that the foregoing agenda was posted on the bulletin board at
the main entrance of the City of Ukiah City Hall, located at 300 Seminary Avenue, Ukiah, California, not less than 72 hours prior to the meeting
set forth on this agenda.
Kristine Lawler, City Clerk
Dated: 10/28/22
Page 6 of 390
Page 1 of 2
Agenda Item No: 3.a.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2191
AGENDA SUMMARY REPORT
SUBJECT: Presentation of the 2022 Ukiah Leadership Academy Graduates.
DEPARTMENT: City Clerk PREPARED BY: Kristine Lawler, City Clerk
PRESENTER: Sage Sangiacomo, City Manager
ATTACHMENTS:
1. 2022 Ukiah Leadership Academy
Summary: Fourteen City of Ukiah team members have completed the third Ukiah Leadership Academy and
will receive Certificates of Completion.
Background: The City Manager is pleased to announce the completion of the 2022 Ukiah Leadership
Academy. This innovative program was developed in 2017 as a result of input on the employee satisfaction
surveys and to help address the need for succession planning.
Over the course of this year, 14 participants from various departments have attended monthly sessions,
culminating in the presentation of their “class project” in the City Council Chambers.
While all City employees have opportunities for technical training related to their specific positions, it can be
difficult to obtain the “soft skills” associated with a leadership position. This program seeks to provide that.
Attendees heard firsthand from upper management in the organization about topics like navigating
communication with the community, the media and the elected officials, leading vs. managing, and more.
The Academy allows the City to develop talent internally and provide additional opportunities for advancement
to those team members who have already invested in the agency. It will improve communication between
departments and, ultimately, the City’s service to the community.
Each session was held at a different City facility and included a tour of that location. “Homework” projects
included practicing agenda summary reports. Each participant selected a topic that would make City
operations more efficient in some way, researched that topic, and developed an agenda summary report and a
presentation around it. Strong work was done by these team members, and some of these projects may result
in actual presentations to Council in the future.
Discussion: The 2022 participants were:
Donald Tubbs, Environmental Lab Technician I
Jason Benson, Senior Civil Engineer
Tom Corning, Patrol Lieutenant
Nick Kirby, Water/Sewer Leadworker
Olga Keough, Finance Controller
Ryan Kriken, Lead Waste Water Treatment Plant Operator
Page 7 of 390
Page 2 of 2
John Corippo, Fire Captain
Sonu Upadhyay, Senior Power Engineer
Steven Oropeza, Senior Building Inspector
Marianne Davison, Senior Recreation Coordinator
Tiffany Breece, Dispatch Supervisor
Tim Mitchell, Senior HR/Management Analyst
Traci Boyl, Senior Management Analyst
Zeb Herinckx, Airport Attendant
The City would like to recognize the achievements of these individuals.
Recommended Action: Receive presentation regarding the 2022 Ukiah Leadership Academy graduates.
BUDGET AMENDMENT REQUIRED: n/a
CURRENT BUDGET AMOUNT: n/a
PROPOSED BUDGET AMOUNT: n/a
FINANCING SOURCE: n/a
PREVIOUS CONTRACT/PURCHASE ORDER NO.: n/a
COORDINATED WITH: Sage Sangiacomo, City Manager and Shannon Riley, Deputy City Manager
Page 8 of 390
2022 Ukiah Leadership Academy
•Donald Tubbs
•Jason Benson
•Tom Corning
•Nick Kirby
•Olga Keough
•Ryan Kriken
•John Corippo
•Sonu Upadhyay
•Steven Oropeza
•Marianne Davison
•Tiffany Breece
•Tim Mitchell
•Traci Boyl
•Zeb Herinckx
Attachment 1
Page 9 of 390
Agenda Item 5a
CITY OF UKIAH
CITY COUNCIL MINUTES
Special Meeting
Virtual Meeting Link: https://zoom.us/j/97199426600
Ukiah, CA 95482
October 5, 2022
6:00 p.m.
1. ROLL CALL AND PLEDGE OF ALLEGIANCE
Ukiah City Council met at a Special Meeting on October 5, 2022, having been legally noticed
on September 30, 2022. The meeting was held virtually at the following link:
https://zoom.us/j/97199426600. Mayor Brown called the meeting to order at 5:01 p.m. Roll was
taken with the following Councilmembers Present: Juan V. Orozco, Douglas, F. Crane, Mari
Rodin, and Jim O. Brown. Councilmember Absent by Prearrangement: Josefina Dueňas.
Staff Present: Shannon Riley, Deputy City Manager; Sage Sangiacomo, City Manager; David
Rapport, City Attorney; Sheri Mannion, Human Resources Director/Risk Manager; and Kristine
Lawler, City Clerk.
MAYOR BROWN PRESIDING.
The Pledge of Allegiance was led by Councilmember Rodin.
2. AUDIENCE COMMENTS ON NON-AGENDA ITEMS
No public comment was given.
THE CITY COUNCIL ADJOURNED TO CLOSED SESSION AT 5:03 P.M.
3. CLOSED SESSION
a. Conference with Legal Counsel—Anticipated Litigation
(Government Code Section 54956.9(d)(2 & 3))
Significant exposure to litigation pursuant to Government Code Section
54956.9(d)(2)(Number of potential cases: 1)
b. Conference with Legal Counsel – Existing Litigation
(Government Code Section 54956.9(d)(1)
Name of case: Roofing & Solar Construction, Inc. v. City of Ukiah et al., Mendocino
County Superior Court Case No. 22CV00048
c. Conference with Legal Counsel – Existing Litigation
(Government Code Section 54956.9(d)(1))
Name of case: Vichy Springs Resort v. City of Ukiah, Et Al; Case No. SCUK-CVPT-
2018-70200
d. Conference with Legal Counsel – Existing Litigation
(Government Code Section 54956.9(d)(1))
Name of case: Russian River Keepers et al. v. City of Ukiah, Case No. SCUK-CVPT-20-
74612
Page 10 of 390
Agenda Item 5a
e. Conference with Real Property Negotiators
(Cal. Gov't Code Section 54956.8)
Property: APN Nos: 003-190-11
Negotiator: Sage Sangiacomo, City Manager
Negotiating Parties: Dave Hull
Under Negotiation: Price & Terms of Payment
Recommended Action: None
Attachments: None
f. Conference with Real Property Negotiators
(Cal. Gov’t Code Section 54956.8)
Property: APN Nos: 003-260-01, 003-500-14
Negotiator: Sage Sangiacomo, City Manager;
Negotiating Parties: Eric Crane and Francine Selim
Under Negotiation: Price & Terms of Payment
g. Conference with Labor Negotiator (54957.6)
Agency Representative: Sage Sangiacomo, City Manager
Employee Organizations: All Bargaining Units
h. Public Employee Performance Evaluation
(Government Code Section 54956
Title: City Manager
4. ADJOURNMENT
There being no further business, the meeting adjourned at 5:55 p.m.
________________________________
Kristine Lawler, City Clerk
Page 11 of 390
AGENDA ITEM 5b
Page 1 of 5
CITY OF UKIAH
CITY COUNCIL MINUTES
Regular Meeting
CIVIC CENTER COUNCIL CHAMBERS
300 Seminary Avenue, Ukiah, CA 95482
Virtual Meeting Link: https://zoom.us/j/97199426600
Ukiah, CA 95482
October 19, 2022
6:00 p.m.
1. ROLL CALL
Ukiah City Council met at a Regular Meeting on October 19, 2022, having been legally noticed on
October 14, 2022. The meeting was held in person and virtually at the following link:
https://zoom.us/j/97199426600. Mayor Brown called the meeting to order at 6:10 p.m. Roll was taken
with the following Councilmembers Present: Juan V. Orozco, Douglas, F. Crane, Mari Rodin,
Josefina Dueňas, and Jim O. Brown. Staff Present: Sage Sangiacomo, City Manager; David
Rapport, City Attorney; and Kristine Lawler, City Clerk.
MAYOR BROWN PRESIDING.
2. PLEDGE OF ALLEGIANCE
The Pledge of Allegiance was led by Shannon Riley, Deputy City Manager.
3. PROCLAMATIONS/INTRODUCTIONS/PRESENTATIONS
4. PETITIONS AND COMMUNICATIONS
Clerk stated that all communications had been distributed.
5. APPROVAL OF MINUTES
a. Approval of the Minutes for the October 5, 2022, Special Meeting.
b. Approval of the Minutes for the October 5, 2022, Regular Meeting.
Motion/Second: Crane/Orozco to approve Minutes of Special and Regular meetings of October 5,
2022, as submitted. Motion carried by the following roll call votes: AYES: Orozco, Crane, Rodin,
Dueňas, and Brown. NOES: None. ABSENT: None. ABSTAIN: None.
6. RIGHT TO APPEAL DECISION
7. CONSENT CALENDAR
a. Report of Disbursements for the Month of August 2022 - Finance.
b. Report of Disbursements for the Month of September 2022 - Finance.
c. Approval of Assignment of Agreement (COU No. 2223-132) for Professional Services to Radian
Generation, LLC. for Compliance and Reporting Services of Electric and Hydro Operations,
Required by Governmental Agencies – Electric Utility.
Page 12 of 390
City Council Minutes for October 19, 2022, Continued:
Page 2 of 5
d. Adoption of Resolution (2022-68) of the City Council Reconsidering the Circumstances of the State
of Emergency and Implementing Teleconferencing Requirements for City Council and Board and
Commission Meetings During a Proclaimed State of Emergency Due to the COVID-19 Pandemic
– City Attorney.
e. Report the Purchase (PO No. 48145) of Two 2023 Ford Hybrid Police Interceptor Utility Vehicles
from Redwood Ford for the Amount of $166,540.52, and Approve Corresponding Budget
Amendment - Police.
Motion/Second: Crane/Orozco to approve Consent Calendar Items 7a-7d, as submitted. Motion
carried by the following roll call votes: AYES: Orozco, Crane, Rodin, Dueňas, and Brown. NOES:
None. ABSENT: None. ABSTAIN: None
8. AUDIENCE COMMENTS ON NON-AGENDA ITEMS
No public comment was received.
9. COUNCIL REPORTS
Presenters: Councilmembers Rodin and Orozco, and Vice Mayor Duenas.
10. CITY MANAGER/CITY CLERK REPORTS
Presenters:
Pumpkinfest Wrap-up – Jake Burgess, Community Services Supervisor.
LATA (Broadband Infrastructure Planning) Grant Update – Jim Robbins, Grants
Manager.
Construction Update – Tim Eriksen, Public Works Director/City Engineer.
Third Leadership Academy – Sage Sangiacomo, City Manager
11. PUBLIC HEARINGS (6:15 PM)
a. Conduct a Public Hearing to Receive Public Comment, Discuss Final Grantee
Performance Under State Community Development Block Grant 20-CDBG-12036, and
Adopt a Resolution to Confirm Project Closeout and Full Reimbursement of Grant
Expenses from the California Department of Housing and Community Development.
Presenters: Jim Robbins, Grants Manager and Matthew Keizer, Chief Building Official.
Public Hearing opened at: 6:47 p.m.
No public comment was received.
Public Hearing closed at: 6:48 p.m.
Motion/Second: Crane/Orozco to adopt a resolution (2022-69) acknowledging accomplishments,
confirming activity completion, and confirming receipt of grant reimbursement funds from the State.
Motion carried by the following roll call votes: AYES: Orozco, Crane, Rodin, Dueňas, and Brown.
NOES: None. ABSENT: None. ABSTAIN: None.
b. Conduct a Public Hearing to Consider Adoption of a Permanent Local Housing Allocation
Plan, Adopt a Resolution Approving the Submittal of an Application in Response to the
2022 State Permanent Local Housing Allocation Program NOFA, and Approve
Corresponding Budget Amendments if Awarded Funding of the Application.
Page 13 of 390
City Council Minutes for October 19, 2022, Continued:
Page 3 of 5
Presenters: Jim Robbins, Grants Manager and Craig Schlatter, Community Development Director.
Public Hearing opened at: 6:55 p.m.
No public comment was received.
Public Hearing closed at: 6:55 p.m.
Motion/Second: Crane/Orozco to adopt the PLHA Five-Year Plan; adopt the Resolution (2022-70)
authorizing the submittal of an application (COU No. 2223-133) to HCD [State of California Housing
and Community Development] for the above activities; and approve corresponding budget
amendments if the application is awarded funding. Motion carried by the following roll call votes:
AYES: Orozco, Crane, Rodin, Dueňas, and Brown. NOES: None. ABSENT: None. ABSTAIN: None.
12. UNFINISHED BUSINESS
a. Receive and File First Quarter Financial Report.
Presenter: Dan Buffalo, Finance Director.
The report was received.
13. NEW BUSINESS
a. Annual Review and Approval of No Changes to the Existing Fee Schedule for the Ukiah
Police Department.
Presenter: Cedric Crook, Interim Police Chief.
Motion/Second: Crane/Orozco to approve no changes to the existing fee schedule for the Ukiah
Police Department. Motion carried by the following roll call votes: AYES: Orozco, Crane, Rodin,
Dueňas, and Brown. NOES: None. ABSENT: None. ABSTAIN: None.
b. Discussion and Possible Action Regarding the Cancellation of the January 4, 2023,
Regular City Council Meeting, with the Option for the Mayor and/or City Manager to Call
for a Special Meeting on an Alternate Date if Time Sensitive Business Arises.
Presenter: Sage Sangiacomo, City Manager.
Motion/Second: Crane/Rodin to approve the cancellation of the January 4, 2023, Regular City
Council Meeting, with the option for the Mayor and/or City Manager to call for a special meeting on
an alternate date if time sensitive business arises. Motion carried by the following roll call votes:
AYES: Orozco, Crane, Rodin, Dueňas, and Brown. NOES: None. ABSENT: None. ABSTAIN: None.
c. Receive Updates on City Council Committee and Ad Hoc Assignments and, if Necessary,
Consider Modifications to Assignments and/or the Creation/Elimination of Ad hoc(s).
Presenter: Sage Sangiacomo, City Manager.
Report was received.
d. Adoption of Resolution(s) Approving Successor Memoranda of Understanding Between
the City of Ukiah and Employee Bargaining Units, and Authorizing the City Manager to
Execute.
Presenter: Sage Sangiacomo, City Manager.
City Clerk, Kristine Lawler, uploaded the resolution with Exhibit A (MOU for Ukiah Police Officers
Association) to the website.
Page 14 of 390
City Council Minutes for October 19, 2022, Continued:
Page 4 of 5
Motion/Second: Orozco/Rodin to adopt a Resolution(s) (2022-71) approving successor
Memoranda of Understanding (COU No. 2223-134 - Ukiah Police Officers Association) between the
City of Ukiah and employee bargaining units, and authorize the City Manager to execute on behalf
of the City. Motion carried by the following roll call votes: AYES: Orozco, Crane, Rodin, Dueňas,
and Brown. NOES: None. ABSENT: None. ABSTAIN: None.
14. CLOSED SESSION
a. Conference with Legal Counsel—Anticipated Litigation
(Government Code Section 54956.9(d)(2 & 3))Significant exposure to litigation pursuant to
Government Code Section 54956.9(d)(2)(Number of potential cases: 1)
b. Conference with Legal Counsel – Existing Litigation
(Government Code Section 54956.9(d)(1)
Name of case: Roofing & Solar Construction, Inc. v. City of Ukiah et al., Mendocino County Superior
Court Case No. 22CV00048
c. Conference with Legal Counsel – Existing Litigation
(Government Code Section 54956.9(d)(1))
Name of case: Vichy Springs Resort v. City of Ukiah, Et Al; Case No. SCUK-CVPT-2018-70200
d. Conference with Legal Counsel – Existing Litigation
(Government Code Section 54956.9(d)(1))
Name of case: Russian River Keepers et al. v. City of Ukiah, Case No. SCUK-CVPT-20-74612
e. Conference with Real Property Negotiators
(Cal. Gov't Code Section 54956.8)
Property: APN Nos: 003-190-11
Negotiator: Sage Sangiacomo, City Manager
Negotiating Parties: Dave Hull
Under Negotiation: Price & Terms of Payment
f. Conference with Real Property Negotiators
(Cal. Gov’t Code Section 54956.8)
Property: APN Nos: 003-260-01, 003-500-14
Negotiator: Sage Sangiacomo, City Manager;
Negotiating Parties: Eric Crane and Francine Selim
Under Negotiation: Price & Terms of Payment
g. Conference with Real Property Negotiators
(Cal. Gov't Code Section 54956.8)
Property: APN Nos: 003-140-54 & 52
Negotiator: Sage Sangiacomo, City Manager
Negotiating Parties: JBT Investments LLC
Under Negotiation: Price & Terms of Donation
h. Conference with Real Property Negotiators
(Cal. Gov't Code Section 54956.8)
Property: APN Nos: 003-140-53
Negotiator: Sage Sangiacomo, City Manager
Negotiating Parties: Marideto LLC
Under Negotiation: Price & Terms of Donation
Page 15 of 390
City Council Minutes for October 19, 2022, Continued:
Page 5 of 5
i. Conference with Labor Negotiator (54957.6)
Agency Representative: Sage Sangiacomo, City Manager
Employee Organizations: All Bargaining Units
j. Public Employee Performance Evaluation
(Government Code Section 54956
Title: City Manager
Closed Session was held during the prior Special Meeting at 5:00 p.m. No report out was
received; direction was given to Staff.
15. ADJOURNMENT
There being no further business, the meeting adjourned at 7:15 p.m.
________________________________
Kristine Lawler, City Clerk
Page 16 of 390
Page 1 of 2
Agenda Item No: 7.a.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2109
AGENDA SUMMARY REPORT
SUBJECT: Adoption of Resolution Approving the City's Participation in the State's Clean Fuel Reward
Program Authorizing the City Manager to Execute the Participating Electric Utility Joinder to the Clean Fuel
Reward Program Governance Agreement; and Approval of the Northern California Power Agency as the City's
Authorized Initial Representative on the Clean Fuel Reward Program Steering Committee.
DEPARTMENT: Electric Utility PREPARED BY: Cindy Sauers, Electric Utility Director
PRESENTER: Cindy Sauers, Electric Utility Director
ATTACHMENTS:
1. FINAL_CFR Governance Agreement.March 3.2020 with Large EDU Signatures
2. Joinder Agreement
3. Joinder Governance Agreement Resolution
Summary: Council will consider adoption of a Resolution approving the City's participation in the State's Clean
Fuel Reward Program and authorizing the City Manager to execute the participating Electric Distribution Utility
Joinder to the Clean Fuel Reward (CFR) Governance Agreement (Attachment 1); and will consider approval of
the Northern California Power Agency (NCPA) as the City's authorized initial representative on the Clean Fuel
Reward Program Steering Committee.
Background: The Clean Fuel Reward (CFR) program is a statewide point of purchase cash rebate program for
electric vehicles (EVs), required by the state's Low Carbon Fuel Standard (LCFS) regulation. This rebate is
available at any participating car dealership within the state and is funded entirely by a percentage of utilities'
LCFS credits earned from residential EV charging. Utilities participating in the LCFS program, including
Ukiah, are required to enter into the CFR Governance Agreement before December 31, 2022, and comply with
the CFR Program's regulatory requirements. Additionally, as a participating electrical utility, Ukiah is required
to deposit $5,125, which is Ukiah's pro rata share of funding, to provide initial rebates for the program by
January 31, 2023. The funds will come from the sale of Ukiah Electric's LCFS credits.
The California Air Resources Board (CARB) developed the LCFS program in compliance with AB 32 (the
Global WarmingSolutions Act of 2006) to reduce the carbon intensity of transportation fuels used in California
by 10% by 2020 and 20% by 2030. Under the LCFS program, providers of alternate fuels generate credits
that can be sold to producers of traditional fossil fuels, helping those entities meet AB32 emission reduction
requirements. Electric Utilities that provide electricity to charge EVs, as Ukiah does, are eligible to receive
LCFS credits based on the number of EVs in their service territory.
As a small utility, the CFR Governance Agreement requires Ukiah to contribute 2% per year of its LCFS
program funds to the CFR program to fund EV rebates starting in 2023.
Discussion: In September 2018, CARB adopted amendments to the LCFS regulation creating a new
statewide, electric utility run point of purchase vehicle purchase CFR program funded exclusively by LCFS
credit revenue. CARB instituted these regulatory amendments to accelerate electric vehicle adoption in an
effort to support the state's greenhouse gas (GHG) reduction goals. Utilities, automakers, CARB and the
California Public Utilities Commission (CPUC) engaged in a collaborative process to implement the regulation
by developing a statewide point of purchase reward program with the goals of achieving equity for all electric
Page 17 of 390
Page 2 of 2
vehicle customers and making it seamless for customers to claim the rebate. Ukiah was represented by
NCPA in this process. The CPUC authorized Southern California Edison (SCE) to serve as the initial, short-
term administrator for the CFR program, and directed the CFR Steering Committee and CARB to engage a
longer-term replacement administrator. Participation requires the execution of the Participating Electric
Distribution Utility joinder (Attachment 2).
In 2022, the CFR program was paused; however, it is anticipated that CARB will restart the program in
2023. If the program is not restarted, the monies will be directed back to the funding utilities. Despite the
pause in the program, utilities are still required to deposit the initial pro rata share in order to continue to
participate in the LCFS program. Proceeds from the sale of the LCFS credits will help fund projects that
promote GHG reduction. An additional requirement of the regulation is that 30% of credits must be set aside
and used for equity programs and projects.
Staff recommends adopting Resolution (Attachment 3) approving the City's participation in the States Clean
Fuel Reward Program, and authorizing the City Manager to execute the participating Electric Utility
Joinder; and approve Northern California Power Agency as the City's authorized initial representative on the Clean
Fuel Reward Program Steering Committee.
Recommended Action: Adopt Resolution approving the City's participation in the State's Clean Fuel Reward
Program and authorizing the City Manager to execute the participating Electric Utility Joinder to the Clean Fuel
Reward Program Governance Agreement; and approve Northern California Power Agency as the City's
authorized initial representative on the Clean Fuel Reward Program Steering Committee.
BUDGET AMENDMENT REQUIRED: No
CURRENT BUDGET AMOUNT: N/A
PROPOSED BUDGET AMOUNT: N/A
FINANCING SOURCE: LCFS Credit Sale
PREVIOUS CONTRACT/PURCHASE ORDER NO.: N/A
COORDINATED WITH: N/A
Page 18 of 390
Attachment 1
Page 19 of 390
Page 20 of 390
Page 21 of 390
Page 22 of 390
Page 23 of 390
Page 24 of 390
Page 25 of 390
Page 26 of 390
Page 27 of 390
Page 28 of 390
Page 29 of 390
Page 30 of 390
Page 31 of 390
Page 32 of 390
Page 33 of 390
Page 34 of 390
Page 35 of 390
Page 36 of 390
Page 37 of 390
Page 38 of 390
Page 39 of 390
Page 40 of 390
Page 41 of 390
Page 42 of 390
Page 43 of 390
Page 44 of 390
Page 45 of 390
Page 46 of 390
Page 47 of 390
Page 48 of 390
Page 49 of 390
Page 50 of 390
Page 51 of 390
Page 52 of 390
Page 53 of 390
Page 54 of 390
Page 55 of 390
Page 56 of 390
Page 57 of 390
Page 58 of 390
Page 59 of 390
Page 60 of 390
Page 61 of 390
Page 62 of 390
Page 63 of 390
Page 64 of 390
Page 65 of 390
Page 66 of 390
Page 67 of 390
Page 68 of 390
Page 69 of 390
Page 70 of 390
Page 71 of 390
Page 72 of 390
Page 73 of 390
Page 74 of 390
Page 75 of 390
Page 76 of 390
Page 77 of 390
Page 78 of 390
43425759.3 55
IN WITNESS WHEREOF, this Agreement has been duly executed on behalf of the
Parties by their respective authorized officers (or respective designee) as of the year and dates first
written above.
Pacific Gas and Electric Company
By:
Name:
Title:
Address for Notice:
___________________________________
___________________________________
Los Angeles Department of Water & Power
By:
Name:
Title:
Address for Notice:
___________________________________
___________________________________
Southern California Edison Company
By:
Name: Kevin E. Walker
Title: Senior Vice President
Address for Notice:
___________________________________
___________________________________
Approved as to Legal Form and Content (optional)
By:
Name:
Title:
Approved as to Legal Form and Content (optional)
By:
Name:
Title:
Approved as to Legal Form and Content (optional)
By:
Name:
Title:
DocuSign Envelope ID: 01A174D4-9122-4EED-AC5C-A4096912C730
Page 79 of 390
San DiegoGas & Electric Company
Name:
Title: yu&
. 1. W r Address lor Notice:
<?>?ybQ vv V<Xic C iiiuc '
€?< •Di ar d.A
Sacramento Municipal Utility District
By:
Name:
Title:
Address for Notice:
Approved as to Legal Form and Content (optional)
By: "i
Name: ( i 1 1 \) IA
Title:
Approved as to Legal Form and Content (optional)
By:
Name:
Title:
43425759.3 56
Page 80 of 390
Page 81 of 390
Page 82 of 390
Page 83 of 390
Page 84 of 390
Page 85 of 390
Page 86 of 390
Page 87 of 390
Page 88 of 390
Page 89 of 390
Page 90 of 390
Page 91 of 390
Page 92 of 390
Page 93 of 390
Page 94 of 390
Attachment 2
43425759.3
EXHIBIT A
PARTICIPATING EDU JOINDER
This JOINDER AGREEMENT (“Joinder Agreement”), dated as of ____________, 2022
is made by the CITY OF UKIAH, a California municipal corporation (the “Joining EDU”), and
delivered to Southern California Edison Company, in its capacity as Program Administrator (in
such capacity and together with any successors in such capacity, the “Program Administrator”)
under that certain Governance Agreement (as amended, amended and restated, supplemented or
otherwise modified from time to time, the “Governance Agreement”; capitalized terms used but
not otherwise defined herein shall have the meanings assigned to such terms in the Governance
Agreement), dated as of March 3, 2020, made by and among Pacific Gas and Electric Company,
San Diego Gas & Electric Company, Southern California Edison Company, Los Angeles
Department of Water & Power, Sacramento Municipal Utility District, and the other electric
distribution utilities (“EDUs) party thereto.
WHEREAS, the Joining EDU is an EDU operating in the State of California and desires
to participate in the CFR Program developed and implemented by the EDUs that are parties to the
Governance Agreement and, in order to participate in the CFR Program, the Joining EDU is
required by the terms of the Governance Agreement and the LCFS Regulation to be joined as a
party to the Governance Agreement as a Participating EDU; and
WHEREAS, this Joinder Agreement supplements the Governance Agreement and is
delivered by the Joining EDU pursuant to Section Error! Reference source not found. of the
Governance Agreement; and
WHEREAS, the Joining EDU will materially benefit directly and indirectly from (i) the
CFR Program and from the LCFS Base Credits made available and to be made available by CARB
to the Joining EDU as a participant in the CFR Program and a Participating EDU under the
Governance Agreement, and (ii) from the Program Administrator’s administration of the CFR
Program on behalf of the Joining EDU and all Participating EDU; and
NOW THEREFORE, the Joining EDU hereby agrees as follows with the Program
Administrator and each other Party to the Governance Agreement:
1. Joinder. The Joining EDU hereby irrevocably, absolutely and unconditionally becomes
a party to the Governance Agreement as a Participating EDU, as a Party, and in each other capacity
(e.g., POU, IOU, Northern EDU, Southern EDU, etc.) under the Governance Agreement that is
applicable to the Joining EDU as a Participating EDU and Party thereunder, and agrees to be bound
by all the terms, conditions, covenants, obligations, liabilities and undertakings applicable to any
such Participating EDU or Party, or to which any such Participating EDU or Party is subject
thereunder, all with the same force and effect as if the Joining EDU were an original signatory to
the Governance Agreement. Without limiting the generality of the foregoing, (a) the Joining EDU
hereby designates and authorizes the Program Administrator to act on its behalf as the Program
Administrator under the Governance Agreement and under any Program Agreement, and
authorizes the Program Administrator to take such actions on its behalf and to exercise such powers
as are delegated to the Program Administrator by the terms hereof or thereof, together with such
actions and powers as are reasonably incidental thereto or as otherwise determined by the Steering
Page 95 of 390
Attachment 2
43425759.3
Committee, in each case in accordance with the terms and conditions of and for the time period
set forth in the Governance Agreement, and (b) the Joining EDU, on its own behalf and on behalf
of its Related Entities, does hereby irrevocably, unconditionally, voluntarily, knowingly, fully,
finally, completely, and forever grant and make the Release and Covenant Not to Sue, and agrees
to the indemnification and other obligations, set forth in Error! Reference source not found. of
the Governance Agreement with full knowledge and in full agreement with all of the terms,
conditions and obligations set forth therein and without limiting the generality of the foregoing
expressly acknowledges and agrees that it has been advised of, and does hereby specifically and
expressly waive and release all rights under, the provisions of Section 1542 of the Civil Code of
California, which provides as follows:
“A GENERAL RELEASE DOES NOT EXTEND TO CLAIMS THAT THE CREDITOR
OR RELEASING PARTY DOES NOT KNOW OR SUSPECT TO EXIST IN HIS OR
HER FAVOR AT THE TIME OF EXECUTING THE RELEASE AND THAT, IF
KNOWN BY HIM OR HER, WOULD HAVE MATERIALLY AFFECTED HIS OR HER
SETTLEMENT WITH THE DEBTOR OR RELEASED PARTY.”
2. Affirmations. The Joining EDU hereby makes each of the representations and warranties
and agrees to each of the covenants contained in the Governance Agreement that is made by any
Participating EDU, Party, and in each other capacity under the Governance Agreement that is
applicable to the Joining EDU as a Participating EDU and Party thereunder. The Joining EDU also
represents and warrants to the Program Administrator and to each other Party that (a) it has the
power and authority, and the legal right, to make, deliver and perform this Joinder Agreement and
has taken all necessary action to authorize the execution, delivery and performance of this Joinder
Agreement, (b) no consent or authorization of, filing with, notice to or other act by or in respect
of, any Governmental Authority or any other Person that has not been obtained, made or completed
is required in connection with the execution, delivery and performance, validity or enforceability
of this Joinder Agreement, (c) this Joinder Agreement has been duly and validly executed and
delivered on behalf of the Joining EDU, (d) the execution, delivery and performance of this
Agreement by such Joining EDU will not violate, conflict with, require consent under or result in
any breach or default under (i) any of such Joining EDU’s organizational, governing or charter
documents, (ii) any applicable law, or (iii) with or without notice or lapse of time or both, the
provisions of any material contract or agreement to which such Joining EDU is a party or to which
any of its material assets are bound, and (e) this Joinder Agreement constitutes a legal, valid and
binding obligation of the Joining EDU enforceable against such Joining EDU in accordance with
its terms, subject to the effects of bankruptcy, insolvency, fraudulent conveyance, reorganization,
moratorium and other similar laws relating to or affecting creditors’ rights generally, general
equitable principles (whether considered in a proceeding in equity or at law) and an implied
covenant of good faith and fair dealing.
3. Miscellaneous. Error! Reference source not found. of the Governance Agreement is
hereby incorporated into this Joinder Agreement by reference and shall be a part hereof, mutatis
mutandis.
[Signature page follows]
Page 96 of 390
Attachment 2
43425759.3
IN WITNESS WHEREOF, the parties hereto have caused this Joinder Agreement to be
executed as of the date first written above by their respective officers thereunto duly authorized.
CITY OF UKIAH
By_____________________
Name:
Title:
Contact Information for Notices:
If not already listed on Schedule Error! Reference source not found. to the Governance
Agreement, the Joining EDU hereby elects to be listed thereon as a Northern EDU.
AGREED TO AND ACCEPTED:
Southern California Edison Company, as Program Administrator
By_____________________
Name:
Title:
Contact Information for Notices:
Page 97 of 390
Attachment 3
RESOLUTION 2022-
RESOLUTION OF THE CITY COUNCIL FOR THE CITY OF UKIAH APPROVING THE CITY’S PARTICIPATION IN
THE STATE’S CLEAN FUEL REWARD PROGRAM AND AUTHORIZING THE CITY MANAGER TO EXECUTE
THE ELECTRIC DISTRIBUTION UTILITY JOINDER TO THE CLEAN FUEL REWARD GOVERNANCE
AGREEMENT
WHEREAS, in 2019, the California Air Resources Board Instituted the Clean Fuel Reward (CFR) as a new
statewide point-of-purchase cash rebate program at participating car dealerships, under the state’s Low
Carbon Fuel Standard (LCFS) regulation; and
WHEREAS, the LCFS regulation requires electric distribution utilities such as Ukiah, which receive funds
through the LCFS program, to contribute 2% of these funds to the CFR program from 2023 forward; and
WHEREAS, participating electric distribution utilities collaboratively developed CFR Program
Governance Agreement to fund and administer the EV rebate program, and the California Public
Utilities Commission approved the agreement in January 2020; and
WHEREAS, participating in the LCFS program has been beneficial to the Ukiah community by garnering
thousands of dollars in funding to facilitate EV adoption in the City, and participating in the CFR program
will meet the needs of the community by seamlessly reducing the purchase price of EVs at the point-of-
purchase; and
WHEREAS, the City’s cost of participating in the CFR program is estimated to be $500-$1,000 per year,
with an initial deposit of $5,125 to be paid by January 31, 2023 and will be funded by the City’s LCFS
Program revenues, with no ratepayer impacts.
NOW, THEREFORE BE IT RESOLVED, that the City Council of the City of Ukiah:
SECTION 1. Approves the City’s participation in the State’s Clean Fuel Reward Program, which will
provide rebates for Electric Vehicles at the point of purchase;
SECTION 2. Approves the Northern California Power Agency (NCPA) to be the City’s initial authorized
representative on the Clean Fuel Reward Program Steering Committee;
SECTION 3. Delegates authority to the City Manager and/or his designee to execute the Participating
Electric Distribution Utility Joinder to the Clean Fuel Reward (CFR) Program Governance Agreement
(Exhibit A).
PASSED, ADOPTED and APPROVED this 2nd day of November, 2022, by the following vote on roll call:
AYES:
NOES:
ABSENT:
ABSTAIN:
________________________________
Jim O. Brown, Mayor
_________________________
Kristine Lawler, City Clerk
ATTEST:
Page 98 of 390
EXHIBIT A
PARTICIPATING EDU JOINDER
This JOINDER AGREEMENT (“Joinder Agreement”), dated as of ____________, 2022
is made by the CITY OF UKIAH, a California municipal corporation (the “Joining EDU”), and
delivered to Southern California Edison Company, in its capacity as Program Administrator (in
such capacity and together with any successors in such capacity, the “Program Administrator”)
under that certain Governance Agreement (as amended, amended and restated, supplemented or
otherwise modified from time to time, the “Governance Agreement”; capitalized terms used but
not otherwise defined herein shall have the meanings assigned to such terms in the Governance
Agreement), dated as of March 3, 2020, made by and among Pacific Gas and Electric Company,
San Diego Gas & Electric Company, Southern California Edison Company, Los Angeles
Department of Water & Power, Sacramento Municipal Utility District, and the other electric
distribution utilities (“EDUs) party thereto.
WHEREAS, the Joining EDU is an EDU operating in the State of California and desires
to participate in the CFR Program developed and implemented by the EDUs that are parties to the
Governance Agreement and, in order to participate in the CFR Program, the Joining EDU is
required by the terms of the Governance Agreement and the LCFS Regulation to be joined as a
party to the Governance Agreement as a Participating EDU; and
WHEREAS, this Joinder Agreement supplements the Governance Agreement and is
delivered by the Joining EDU pursuant to Section Error! Reference source not found. of the
Governance Agreement; and
WHEREAS, the Joining EDU will materially benefit directly and indirectly from (i) the
CFR Program and from the LCFS Base Credits made available and to be made available by CARB
to the Joining EDU as a participant in the CFR Program and a Participating EDU under the
Governance Agreement, and (ii) from the Program Administrator’s administration of the CFR
Program on behalf of the Joining EDU and all Participating EDU; and
NOW THEREFORE, the Joining EDU hereby agrees as follows with the Program
Administrator and each other Party to the Governance Agreement:
1.Joinder. The Joining EDU hereby irrevocably, absolutely and unconditionally becomes
a party to the Governance Agreement as a Participating EDU, as a Party, and in each other capacity
(e.g., POU, IOU, Northern EDU, Southern EDU, etc.) under the Governance Agreement that is
applicable to the Joining EDU as a Participating EDU and Party thereunder, and agrees to be bound
by all the terms, conditions, covenants, obligations, liabilities and undertakings applicable to any
such Participating EDU or Party, or to which any such Participating EDU or Party is subject
thereunder, all with the same force and effect as if the Joining EDU were an original signatory to
the Governance Agreement. Without limiting the generality of the foregoing, (a) the Joining EDU
hereby designates and authorizes the Program Administrator to act on its behalf as the Program
Administrator under the Governance Agreement and under any Program Agreement, and
authorizes the Program Administrator to take such actions on its behalf and to exercise such powers
as are delegated to the Program Administrator by the terms hereof or thereof, together with such
actions and powers as are reasonably incidental thereto or as otherwise determined by the Steering
Page 99 of 390
Committee, in each case in accordance with the terms and conditions of and for the time period
set forth in the Governance Agreement, and (b) the Joining EDU, on its own behalf and on behalf
of its Related Entities, does hereby irrevocably, unconditionally, voluntarily, knowingly, fully,
finally, completely, and forever grant and make the Release and Covenant Not to Sue, and agrees
to the indemnification and other obligations, set forth in Error! Reference source not found. of
the Governance Agreement with full knowledge and in full agreement with all of the terms,
conditions and obligations set forth therein and without limiting the generality of the foregoing
expressly acknowledges and agrees that it has been advised of, and does hereby specifically and
expressly waive and release all rights under, the provisions of Section 1542 of the Civil Code of
California, which provides as follows:
“A GENERAL RELEASE DOES NOT EXTEND TO CLAIMS THAT THE CREDITOR
OR RELEASING PARTY DOES NOT KNOW OR SUSPECT TO EXIST IN HIS OR
HER FAVOR AT THE TIME OF EXECUTING THE RELEASE AND THAT, IF
KNOWN BY HIM OR HER, WOULD HAVE MATERIALLY AFFECTED HIS OR HER
SETTLEMENT WITH THE DEBTOR OR RELEASED PARTY.”
2.Affirmations. The Joining EDU hereby makes each of the representations and warranties
and agrees to each of the covenants contained in the Governance Agreement that is made by any
Participating EDU, Party, and in each other capacity under the Governance Agreement that is
applicable to the Joining EDU as a Participating EDU and Party thereunder. The Joining EDU also
represents and warrants to the Program Administrator and to each other Party that (a) it has the
power and authority, and the legal right, to make, deliver and perform this Joinder Agreement and
has taken all necessary action to authorize the execution, delivery and performance of this Joinder
Agreement, (b) no consent or authorization of, filing with, notice to or other act by or in respect
of, any Governmental Authority or any other Person that has not been obtained, made or completed
is required in connection with the execution, delivery and performance, validity or enforceability
of this Joinder Agreement, (c) this Joinder Agreement has been duly and validly executed and
delivered on behalf of the Joining EDU, (d) the execution, delivery and performance of this
Agreement by such Joining EDU will not violate, conflict with, require consent under or result in
any breach or default under (i) any of such Joining EDU’s organizational, governing or charter
documents, (ii) any applicable law, or (iii) with or without notice or lapse of time or both, the
provisions of any material contract or agreement to which such Joining EDU is a party or to which
any of its material assets are bound, and (e) this Joinder Agreement constitutes a legal, valid and
binding obligation of the Joining EDU enforceable against such Joining EDU in accordance with
its terms, subject to the effects of bankruptcy, insolvency, fraudulent conveyance, reorganization,
moratorium and other similar laws relating to or affecting creditors’ rights generally, general
equitable principles (whether considered in a proceeding in equity or at law) and an implied
covenant of good faith and fair dealing.
3.Miscellaneous. Error! Reference source not found. of the Governance Agreement is
hereby incorporated into this Joinder Agreement by reference and shall be a part hereof, mutatis
mutandis.
[Signature page follows]
Page 100 of 390
IN WITNESS WHEREOF, the parties hereto have caused this Joinder Agreement to be
executed as of the date first written above by their respective officers thereunto duly authorized.
CITY OF UKIAH
By_____________________
Name:
Title:
Contact Information for Notices:
If not already listed on Schedule Error! Reference source not found. to the Governance
Agreement, the Joining EDU hereby elects to be listed thereon as a Northern EDU.
AGREED TO AND ACCEPTED:
Southern California Edison Company, as Program Administrator
By_____________________
Name:
Title:
Contact Information for Notices:
Page 101 of 390
Page 1 of 2
Agenda Item No: 7.b.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2119
AGENDA SUMMARY REPORT
SUBJECT: Authorization for the City Manager to Execute a Construction Administration Services Agreement
with Mead and Hunt, Inc. for Runway 15-33 Pavement Rehabilitation Phase 2 Construction Continguent on
Approval from the FAA, and Approve Corresponding Budget Amendment.
DEPARTMENT: Airport PREPARED BY: Greg Owen, Airport Manager
PRESENTER: Greg Owen
ATTACHMENTS:
1. Mead & Hunt Contract
2. Independent Fee Estimate
Summary: The FAA has awarded the Airport with a construction grant for the Runway 15-33 Pavement
Rehabilitation Phase 2 project to complete the runway 15-33 width reduction from 150 Feet to 75 Feet; and
install new lighting (Construction). Mead and Hunt, Inc. has submitted a contract to provide construction
administration services. Therefore, Staff is seeking for Council to consider authorizing the City Manager to
Execute a Construction Administration Services Agreement for this project.
Background: On April 14, 2022, the project - Runway 15-33 width reduction from 150 feet to 75 feet; and install
new LED MIRLS (Medium Intensity Runway Lighting System), Runway Threshold Lights (Remove and Install New),
a New Runway 15 LED REIL (Runway End Identifier Lights), New Runway 33 LED REIL Installation, and a New
LED PAPI (Precision Approach Path Indicator) - was solicited for competitive bids, with the lowest responsive and
responsible bidder being Royal Electric, with a bid amount of $2,222,222.00.
The FAA funding is 90% of the total project cost, which is $2,713,255.79 (Royal Electric $2,222,222; Project
Administration and Inspection expense $242,246.90; and Independent Fee Estimate (IFE) $2,340, plus a 10%
contingency in the amount of $246,446.89 for construction and project management). Caltrans grant match of
5%, is $112,926.
The balance of the funds, or $158,399.58, will be funded from the Airport Fund.
The timing of this project is a concern that Staff has grappled with, since the Airport is open every day year
round. However, due to construction requirements and FAA funding for this project, the runway may be closed
during fire season, causing Cal Fire to relocate for several weeks. Cal Fire air tankers will be relocated to the
next closest bases, Santa Rosa and Chico, which are between 15-25 minutes away by air. Cal Fire supports
this project, and Staff has been working with Cal Fire on the projected runway closures. Helicopter access will
not be impacted by the project, even during construction. Staff will continue to work with the contractor to limit
the impact on Cal Fire and other airport users.
Discussion: Staff is requesting that the City Manager be authorized to execute the construction administration
services agreement (Attachment 1) with Mead and Hunt, Inc. for Runway 15-33 Pavement Rehabilitation
Phase 2. As part of the grant process, an independent fee estimate (IFE) is required from a separate
consulting firm. Staff requested Independent Fee Estimates to perform the required review of this project.
The IFE Spreadsheet is provided as Attachment 2. Staff has found that the Mead and Hunt, Inc. total project
costs are higher than the independent fee estimate. Staff has discussed this with Mead and Hunt, Inc. and
Page 102 of 390
Page 2 of 2
have determined that the independent fee estimate was lower due to the assumption that only staff from the
Sonoma County office would be working on this project. Due to the specialized nature of FAA projects, Mead
and Hunt, Inc. will be required to bring in staff from other offices. The cost of Mead and Hunt, Inc.'s contract is
included in the total cost of the grant.
Project Administration and Inspection Grant Estimate: $242,246.90
Independent Fee Estimate Project Cost: $133,391.75 (Attachment 2 Independent Fee Estimate (IFE)
Mead and Hunt, Inc.'s Total Project Cost:$242,246.90
Staff will be reviewing the cost difference with the FAA prior to executing the agreement with Mead and Hunt,
Inc. Thus, staff is requesting City Manager authorization to execute the contract with Mead and Hunt, Inc.
contingent on approval from the FAA.
As part of the recommended action, a budget adjustment for the whole project needs to be approved, to align
the budget with known costs to date.
Recommended Action: Authorize the City Manager to Execute a Construction Administration Services
Agreement with Mead and Hunt Inc. for Runway 15-33 Pavement Rehabilitation Phase 2 Construction
contingent upon the FAA's approval of costs, and approve corresponding budget amendment.
BUDGET AMENDMENT REQUIRED: Yes
CURRENT BUDGET AMOUNT: 77825200.80320.18032: $2,731,706 ; 7700000.43299.18032 (FAA Grant):
$2,258.536 ; 77800000.43173.18032 (Caltrans Grant): $112,926
PROPOSED BUDGET AMOUNT: 77825200.80230.18032: $2,713,256; 7700000.43299.18032 (FAA Grant):
$2,441,931
FINANCING SOURCE: FAA Grant, Caltrans Grant, and Airport Funds
PREVIOUS CONTRACT/PURCHASE ORDER NO.: N/A
COORDINATED WITH: Mary Horger, Financial Services Manager
Page 103 of 390
Exhibit A
Page 1 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
City of Ukiah
UKIAH MUNICIPAL AIRPORT
Construction Administration Scope of Services
for
Runway 15-33 MIRL, FAA PAPI and REIL Installation Phase 2
FAA AIP No.: 3-06-0268-020-2022
October 18, 2022 (Final)
PROJECT DESCRIPTION
This Scope of Services details the Construction Administration (CA) services to be provided by Mead &
Hunt, Inc. (CONSULTANT) for the Runway 15-33 MIRL, FAA PAPI and REIL Installation, Phase 2 (Project)
at the Ukiah Municipal Airport (Airport) for the City of Ukiah (SPONSOR). Work for this Project will be
funded by the Federal Aviation Administration (FAA) under the Airport Improvement Program (AIP) Grant
No. 3-06-0268-020-2022 and is subject to compliance with FAA regulations and standards.
Background
The Project is a continuation of the runway width reduction project. In December of 2020, Phase 1 of the
Project, which was reconstructing the center 75-foot keel, section was completed. This also included the
demolition of Taxiway B and the construction of a new connector taxiway, A2. This construction was
completed under FAA AIP Grant No. 3-06-0268-015-2019.
The CONSULTANT submitted the final bid documents for this Project to the SPONSOR on March 2, 2022.
Bid opening occurred on April 14, 2022, and the SPONSOR will subsequently submit a final grant
application to the Federal Aviation Administration (FAA) to receive federal funding for the construction of
the Project. It is anticipated that the FAA will award the construction grant in the summer or early fall of
2022, in advance of the SPONSOR issuing the Notice to Proceed (NTP) for this scope of work. The
estimated cost of construction is $2,089,540.00.
Project Elements
The Project will consist of the following elements:
Schedule 1: Runway 15-33 Width Reduction:
a) Installation of new LED Medium Intensity Runway Lights
b) Installation of new LED Medium Intensity Taxiway Lights
c) Installation of new LED Threshold Lights
d) Installation of new LED Guidance Signs
e) Installation of new CCR in Existing Vault
f) New conduit and cable for Runway and Taxiway Homerun
g) New Runway Pavement Markings
Page 104 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 2 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
Schedule 2: New FAA LED REILs and New FAA LED PAPI:
a) Installation of Runway 15 LED REILs
b) Installation of Runway 33 LED REILs
c) Demolition of Existing FAA VASIs
d) Installation of New LED Precision Approach Path Indicator
Project Duration
The Project has been divided into two Elements: 1) Mobilization and 2) Construction as detailed in the
Construction Safety and Phasing Plan (CSPP). The SPONSOR will issue separate NTPs to the Contractor
for the Mobilization Element and the Construction Element. The NTP for the Construction Element will not
be issued until the Mobilization Element is complete and the Contractor-provided Safety Plan Compliance
Document (SPCD) is approved by the SPONSOR. The anticipated Project duration is as follows:
Project Element Duration
Mobilization 30 Working Days
Construction Schedules 1 & 2 30 Working Days
Total 60 Working Days
Project Team
the CONSULTANT Under the supervision of a Senior Project Engineer, will assign a Project Manager (PM)
to this Project to monitor continuity through the phases of work, as described in this scope. The PM will be
responsible for the overall administration and review of construction progress, as well as coordination of
the team and subconsultant staff. Specific Project management tasks are detailed within
each phase of work as described in this Scope of Services.
The CONSULTANT will also assign a Project Construction Observer (CO) to oversee the day-to-day
construction activities. The CO will be on the jobsite with the Contractor and will document work performed
and monitor conformance with the Project Plans and Specifications. The CO will also coordinate material
testing with CON . CO responsibilities are detailed in Phase 3 of this scope of
work.
The CONSULTANT team will also consist of Project Engineers, Engineer III, II, and I designers, Technician
II, construction observers, and administrative and clerical staff as needed to perform the tasks in this scope
of work.
The CONSULTANT will perform material testing and CA services for the Project.
SCOPE OF SERVICES
T follows (and so referenced throughout
this scope):
1) Phase 1 Pre-Construction Services
2) Phase 2 Construction Administration Services
3) Phase 3 Construction Observation
4) Phase 4 Material Testing
5) Phase 5 Post-Construction Services
Page 105 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 3 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
PHASE 1 PRE-CONSTRUCTION SERVICES
1.1 PHASE 1 PROJECT MANAGEMENT AND COORDINATION
Project management tasks during Phase 1 will consist of the following:
1.1.1 Prepare Contract and Project Setup
The Senior Project Engineer, the PM, engineering and technical support and
administrative staff will prepare the contract between the CONSULTANT and the
SPONSOR. Administrative staff will also setup the internal Project database for finance
tracking, and internal Project directory for saving CA files.
1.1.2 Prepare Schedule
The PM will prepare, and the Project Engineer will review, a coordination schedule upon
receiving the Notice to Proceed (NTP) from the SPONSOR. This schedule will only show
major milestones to facilitate overall coordination of the Project. The Contractor will be
responsible for submitting a detailed construction schedule with work activities.
1.1.3 Prepare Project Management Plan (PMP)
The PM will prepare a PMP that will address the following Project elements: Vision and
Objectives, Project Team Roles and Responsibilities, Document Distribution Plan,
Communications Plan, Quality Control Plan, and Change Management Plan. The PM will
use the PMP as a tracking tool for the various elements throughout the Project.
1.1.4 Coordinate CONSULTANT Team
The PM and Senior Project Engineer will assign team members to the Project for office
CA activities and assign a CO to the Project for day-to-day field observation activities.
The PM will coordinate with the CO to plan for construction activities and identify
additional team members if needed to support the CO.
1.1.5 Coordinate Subconsultant(s) NIC1
1.1.6 Prepare Invoices
The PM will maintain a Project budget table to track costs on a monthly basis. At the
beginning of each month, the PM will review accrued costs from the previous month and
work with accounting staff to prepare invoices for the SPONSOR. The invoices will be
submitted in accordance with the SPONSOR e
invoices will include detailed cost breakdowns referencing the items in this scope of work
and indicate percent complete for each item. It is anticipated that one (1) invoice will be
prepared during the Phase 1 Pre-Construction services of this scope.
1.2 PHASE 1 PROJECT MEETINGS AND COMMUNICATION
The CONSULTANT will participate in various meetings and calls during Phase 1. Meetings and
communication items will be as follows:
1.2.1 Pre-Construction Conference
The CONSULTANT will arrange for and conduct the pre-construction conference. The
purpose of this conference is to review FAA and Project-specific requirements prior to
commencing construction. The conference is anticipated to be conducted at the Airport
and will be attended by the CONSULTANT, SPONSOR, representatives of FAA Airports
1 NIC = Not in Contract
Page 106 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 4 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
District Office (if possible), Contractor, subcontractors, and Airport tenants affected by
construction. The conference will include the following sub-tasks:
a. The CONSULTANT will schedule the conference and prepare an agenda to support
the meeting, as well as presentation material to illustrate the Project work areas.
b. The CONSULTANT will obtain and review the Project construction schedules from
the Contractor prior to presentation at the pre-construction conference. The
SPONSOR will be provided with copies of the construction schedules.
c. The CONSULTANT will preside at the pre-construction conference, prepare a record
of the conference, submit meeting minutes to the SPONSOR for review and
comment, and distribute the final meeting minutes to attendees. Up to two (2)
members from CONSULTANT team will attend (anticipated to consist of PM and CO).
1.2.2 Quality Control (QC) / Quality Assurance (QA) Workshop
The CONSULTANT team will attend and the contractor will conduct a QC/QA workshop
in accordance with Project Specification Item C-100. The QC/QA workshop will be
coordinated to occur during the pre-construction conference. A separate meeting agenda
and minutes will be prepared for the QC/QA workshop. The meeting will be attended by
the CONSULTANT team, SPONSOR, representatives of FAA Airports District Office (if
Up to three
(3) members from the CONSULTANT team will attend (anticipated to consist of PM,
Senior Engineer, and CO).
1.2.3 General Communication with SPONSOR and Contractor
The CONSULTANT will communicate with the SPONSOR and Contractor throughout
Phase 1 as needed via phone calls or email in addition to the meetings listed herein. One
hour each per week is anticipated.
1.3 PREPARE PROJECT DOCUMENTATION
The CONSULTANT will review / prepare the following Project documentation:
a. The CONSULTANT will review the construction contract, which will include checking that the
Contractor has met the Disadvantaged Business Enterprise (DBE) goal or made a good-faith
effort towards meeting the goal, and that the Contractor has provided proof of insurance and
the required bonds.
b. The CONSULTANT will assist the SPONSOR in preparing NTP letters for both the Mobilization
and Construction elements.
c. The CONSULTANT will setup templates for Project documentation on CONSULTANT standard
forms or SPONSOR-provided forms as applicable. Documentation will include, but is not limited
to, submittal review forms, weekly FAA reports, weekly charged working day reports, RFIs,
RFCPs, field directives, contract change orders, non-compliance notices, and applications for
payment.
d. The CONSULTANT will provide the Contractor with CAD files if requested (upon receipt of
CONSULTANT-provided disclaimer form signed by Contractor).
1.4 REVIEW MATERIAL SUBMITTALS FOR COMPLIANCE
The CONSULTANT will review Contractor-submitted material cut sheets, mix designs, shop
drawings, and certificates for compliance with Plans and Specifications. It is expected that up to
Page 107 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 5 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
nineteen (19) submittals will be provided by the Contractor for review. The scope assumes each
submittal will require up to one (1) resubmittal due to incomplete or incorrect information by the
Contractor. If more than one (1) resubmittal is required due to incomplete or incorrect information
by the Contractor, the cost for the CONSULTANT to review the resubmittal will be the responsibility
of the Contractor as stated in Specification Item SP-100. The CONSULTANT will also maintain a
submittal checklist, and track dates of submission and review.
1.5 PREPARE CONSTRUCTION MANAGEMENT PLAN (CMP)
The CONSULTANT will obtain the Contractor's QC Plan and will subsequently prepare the CMP.
The CMP combines data from the QC Plan with information of Project responsibilities from the
SPONSOR and CONSULTANT. The CMP will outline the submittal requirements and materials
testing requirements, as set forth in the construction documents and contained in FAA Advisory
Circular (AC) 150/5370-10H, Standard Specifications for Construction of Airports . The CMP will
summarize the types and frequency of testing required for quality acceptance, in addition to the
credentials of those performing the testing. A preliminary copy of the CMP will be submitted to the
SPONSOR and FAA for approval. After SPONSOR and FAA review, the CMP will be revised if
needed, and issued to the Contractor for use during the Project.
PHASE 1 DELIVERABLES
1) Pre-Construction Conference Meeting Minutes electronic files to SPONSOR and attendees
2) QC/QA Workshop Meeting Minutes electronic files to SPONSOR and attendees
3) Review of Contractor Submittals electronic files to SPONSOR and Contractor
4) CMP electronic files to SPONSOR, FAA, and Contractor
PHASE 2 CONSTRUCTION ADMINISTRATION (CA) SERVICES
2.1 PHASE 2 PROJECT MANAGEMENT AND COORDINATION
Project management tasks during Phase 2 will consist of the following:
2.1.1 Update Schedule
The schedule created during Phase 1 will be updated throughout construction as
necessary, based on actual milestones completed.
2.1.2 Coordinate PMP Updates
The PM will continue to coordinate and monitor PMP during Phase 2.
2.1.3 Coordinate CONSULTANT Team
The PM will assign responsibilities to office staff to complete the documentation efforts
described herein. The PM will also communicate with the CO on a regular basis to monitor
progress in the field. As part of this effort, the PM will create and maintain a detailed
construction checklist for the CO to keep track of action items, quantities, production
rates, and contractor compliance with Plans and Specifications. The PM will also review
daily reports prepared by the CO.
2.1.4 Coordinate Subconsultant - NIC
No subconsultants will be required. The PM will coordinate and schedule site visits for
tests by the CONSULTANT to perform QA testing.
Page 108 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 6 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
2.1.5 Prepare Invoices
The PM will continue to maintain the Project budget table and prepare invoices as defined
in Phase 1. It is anticipated that three (3) invoices will be prepared during Phase 2.
2.2 PHASE 2 PROJECT MEETINGS AND COMMUNICATION
The CONSULTANT will participate in various meetings and calls during Phase 2. Meetings and
communication items will be as follows:
2.2.1 Weekly Construction Progress Meetings
The CONSULTANT will conduct weekly meetings with the SPONSOR and Contractor to
discuss safety, schedule, work progress, action items, documentation, and other items
as needed to keep construction on track. FAA representatives may also attend some of
the meetings if appropriate. Up to five (5) meetings are anticipated during Phase 2. The
meetings are anticipated to be held in-person at a location near the job site. The CO will
attend each meeting in-person (as stated in Phase 3). The PM will also attend each
meeting, either in-person or virtually as appropriate for the work being performed that
week. The CONSULTANT will prepare an agenda and minutes to support each meeting.
2.2.2 Site Visits During Construction
The CONSULTANT will conduct periodic site visits to review Project progress and
monitor construction activities through substantial completion of the Construction
Element. Up to five (5) site visits are anticipated during Phase 2. Up to two (2) members
from the CONSULTANT team will attend each site visit (anticipated to consist of PM and
Engineer I).
2.2.3 General Communication with SPONSOR and Contractor
The CONSULTANT will communicate with the SPONSOR and Contractor throughout
Phase 2 as needed via phone calls or email in addition to the meetings listed herein.
2.3 WEEKLY WORKING-DAY REPORTS
The CONSULTANT will prepare weekly working-day reports tracking contract time and submit to
the Contractor for review. The reports will include days charged and documented weather, as well
as identification of days not charged due to inclement weather or other justified delays. Up to nine
(9) weekly working-day reports are anticipated for the Project.
2.4 WEEKLY FAA PROGRESS REPORTS
The CONSULTANT will prepare weekly FAA reports documenting the progress of the Project. The
reports will be based on FAA form 5370-1, Construction Progress and Inspection Report, and
include days charged, weather summary, percent completion, work in progress for current week
and following week, summary of material testing, and problem areas if applicable. The
CONSULTANT will also attach photographs documenting work completed. The CONSULTANT will
sign each report and send to FAA. Up to five (5) weekly FAA progress reports are anticipated for
the Project.
2.5 REQUESTS FOR INFORMATION (RFIs)
The CONSULTANT will prepare written responses, as necessary, to Contractor RFIs to clarify
design intent. Depending on the RFI, the response may require review of documentation not
Page 109 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 7 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
included in the Contract Documents, as well as coordination with and review by additional
CONSULTANT staff, SPONSOR, or FAA. Up to five (5) RFIs are anticipated for the Project.
2.6 GENERAL FIELD COORDINATION
In addition to formal RFIs, the CONSULTANT will respond to various questions and concerns that
arise in the field. Depending on the issue, the response may require review of documentation not
included in the Contract Documents, as well as coordination with and review by additional
CONSULTANT staff, SPONSOR, or FAA.
2.7 REQUESTS FOR COST PROPOSALS (RFCPs)
The CONSULTANT will prepare RFCPs if additional work is anticipated or desired, either due to
unforeseen site conditions, SPONSOR request for additional work, or other reasons as applicable.
The RFCP(s) will include a description of change, quantity estimates, and exhibits as needed to
illustrate the change. The CONSULTANT will send the RFCP to the Contractor to provide a cost
proposal. The CONSULTANT and the SPONSOR will then review the cost proposal to determine
if it is reasonable and follow up with negotiations, as necessary. The CONSULTANT will
communicate the proposed change and cost to the FAA for their concurrence prior to authorizing
the work. Depending on the determination, the CONSULTANT will prepare a field directive or
change order as described below. Up to two (2) RFCPs are anticipated for this Project.
2.8 FIELD DIRECTIVES
The CONSULTANT will prepare field directives as necessary to formalize direction that is not
otherwise stated in the Project Plans or Specifications, or in a response to an RFI. Following the
RFCP process above, the CONSULTANT will prepare a field directive authorizing the Contractor
to proceed with work as described. The field directive will include a description of change, quantity
estimates, and the related RFCP as applicable. If the field directive results in a change of quantities
or cost, it will be followed with a change order as described below. Up to two (2) field directives are
anticipated for the Project.
2.9 CONTRACT CHANGE ORDERS (CCOs)
Following the RFCP and field directive processes, the CONSULTANT will prepare CCOs to
formalize the change to the Contract cost. The CCO will consist of a CONSULTANT-prepared form
that follows the guidance of FAA Standard Operating Procedure (SOP) 7.00, Airport Improvement
Program Construction Project Change Orders . The form will include a table of the bid items that
changed in quantity, or new bid items that were created to capture the CCO cost. The form will also
include additional pages containing the FAA-required justification items in accordance with SOP
7.00. Documentation to support the CCO will be attached to the form, including but not limited to
RFCPs, field directives, Contractor time-and-expense reports, emails, and exhibits. CCOs will be
submitted to the SPONSOR and Contractor for review and signature and then be submitted to the
FAA by the CONSULTANT or the SPONSOR. CCOs that require new design elements are not
included in this scope of services. Up to two (2) CCOs are anticipated for the Project.
2.10 REVIEW OF QC/QA TEST RESULTS
The CONSULTANT will review test results provided by the Contractor to determine conformance
with the Project Plans and Specifications. If test results are failing, the CONSULTANT will
coordinate with the SPONSOR and Contractor to establish corrective actions. Depending on the
Page 110 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 8 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
nature of the testing, the CONSULTANT may need to coordinate with the FAA to determine
appropriate actions.
2.11 CERTIFIED PAYROLL AND DAVIS BACON REQUIREMENTS
The Federal Contract Provisions require that payroll and basic records relating to the Project be
maintained and comply with the Davis-Bacon Act Requirements (2 CFR § 200, Appendix II(D), 29
CFR Part 5). Such records shall contain the name, address, and social security number of each
such worker; his or her correct classification; hourly rates of wages paid (including rates of fringe
benefits or cash equivalents); daily and weekly number of hours worked; deductions made; and
actual wages paid.
The Contractor is responsible for the submission of copies of payrolls for all employees as well as
all subcontractors. Contractor will submit these documents to the CONSULTANT. Documents to
be provided include:
a. Fringe Benefits Statement
b. Certified Payroll Wage Hour Report
c. Statement of compliance
d. Non-performance week(s) documentation
The CONSULTANT will review Contractor-submitted payroll reports and monitor
compliance with paying employees per the Davis-Bacon Act requirements. Up to ten (10) weeks
of payroll reports are anticipated.
CONSULTANT will review up to two reports of each Contractor-submitted certified payroll. If more
than two reviews are required due to lack of information or incorrect information, the Contractor
shall be responsible for additional costs incurred. (Certified payroll must be submitted, reviewed,
and accepted prior to payment to Contractor each month.)
2.12 MONTHLY APPLICATIONS FOR PAYMENT
The CONSULTANT will track quantities on a weekly basis, based on CO daily reports, and share
with the Contractor for concurrence. At the beginning of each month, the CONSULTANT will review
progress billings submitted by the Contractor, prepare applications for payment using
CONSULTANT standard forms, and submit to the SPONSOR for processing. The CONSULTANT
will maintain a tracking spreadsheet with the bid items, showing work complete for previous periods,
current period, and total to date. This spreadsheet will be attached to the application for payment
each month. An explanation of variation between the contract and pay quantities (if any) will be
provided. Up to four (4) applications for payment are anticipated for the Project.
2.13 SUBSTANTIAL COMPLETION WALK-THROUGH AND DOCUMENTATION
2.13.1 Substantial Completion Walk-Through
The CONSULTANT will schedule and conduct a walk-through with the SPONSOR and
the Contractor to determine whether the Project has reached substantial completion and
verify that the work is in accordance with the Plans and Specifications. The
CONSULTANT will document items found to be deficient and will provide the Contractor
with a list of those items. The walk-through will be scheduled to occur near the end of
construction when the Contractor is still on-site and can easily mobilize to complete punch
list items. The PM and the CO will attend the walk-through (CO attendance as described
Page 111 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 9 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
in Phase 3). It is assumed a follow-up walk-through will not be needed after punch list
items are complete. The CO and SPONSOR will observe the completed Project during
final marking application, and the SPONSOR will continue to monitor punch list items if
needed after final marking application.
2.13.2 Punch List and Substantial Completion Letter
The CONSULTANT will prepare and maintain a punch list to include the deficient items
discovered prior to, during, and after the substantial completion walk-through. The PM
will coordinate with the CO to identify punch list items in advance of the walk-through and
will continue to add and update items as they are identified and completed. The
CONSULTANT will send each punch list update to the SPONSOR and Contractor. Upon
completion of the walk-through, the CONSULTANT will prepare a substantial completion
letter summarizing the findings of the walk-through and outstanding items remaining for
Project closeout; the letter will include the current version of the punch list items. The
CONSULTANT will submit this letter to the SPONSOR and Contractor.
PHASE 2 DELIVERABLES
1) Weekly Construction Progress Meeting Minutes electronic files to attendees
2) Weekly Working-Day Reports electronic files to the SPONSOR and Contractor
3) Weekly FAA Progress Reports electronic files to the SPONSOR and FAA
4) RFI Responses electronic files to the SPONSOR and Contractor
5) RFCPs electronic files to the SPONSOR and Contractor
6) Field Directives electronic files to the SPONSOR and Contractor
7) CCOs electronic files to the SPONSOR, Contractor, and FAA
8) Monthly Applications for Payment electronic files to the SPONSOR
9) Punch List and Substantial Completion Letter electronic files to SPONSOR and Contractor
PHASE 3 CONSTRUCTION OBSERVATION
3.1 DAILY CONSTRUCTION OBSERVATION
This task will include construction observation, coordination of material testing during construction,
and on-site construction administration for the duration of the Project. A full-time CO will be
assigned to this Project. The CO will have experience with civil improvement projects as required
for the Project. The CO will work with the PM to oversee the construction progress throughout the
Project. The duration for the Construction Element is anticipated to be 60 contractual working days
(split into 2 phases as stated in the Project Duration section). The budget for construction
observation has been developed based upon the Contractor working 22 shifts, with a 10.0-hour
workday; two additional days were allotted for the CO, one day at the beginning and one day at the
end of construction for set-up and clean-up, for a total of 24 shifts.
It is anticipated that the CO will need support during key-work activities (such as electrical activation
of lights, PAPI, REILs). The PM will designate a supporting Construction Observer (CO) as
necessary to support the CO in the field. Up to four shifts are anticipated for the supporting CO, in
addition to the 24 shifts for the CO.
Page 112 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 10 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
The CO and supporting CO will perform construction observation services including (as applicable),
but not limited to, the following:
a. Prepare daily reports to record the construction history of the Project. The reports will be made
available to the SPONSOR upon request for review during inspections or visits. The daily
reports will include, but not be limited to, the following information: weather conditions, number
of Contractor / subcontractor personnel and major equipment onsite, general location of work,
description of work items, estimated quantities, safety items, materials delivered, delays /
issues (if applicable), QC/QA tests performed, failed tests (if any) and action taken, instructions
to Contractors, record of visitors to Project and verbal or written instructions given, record of
telephone conversations and any verbal instructions received or authorizations granted,
engineering field force activity and hours worked, and detailed log of work completed
throughout the day.
b. Review and check layout and surveys conducted by the Contractor in accordance with the
Plans and Specifications.
c. Check construction activities for compliance with Plans and Specifications.
d. Respond to Contractor questions that arise in the field and communicate with PM to coordinate
direction.
e. Evaluate and determine the acceptability of substitute materials and equipment proposed by
the Contractor.
f. modifications to Plans or Specifications and report
those suggestions to the SPONSOR and PM.
g. Acquire field measurements.
h. CSPP and immediately bring any non-compliance
issues to the attention of the Contractor and the SPONSOR.
i. QC Program.
j. Assist PM in coordinating QA testing as stated in Phase 4. Communicate with Contractor to
facilitate the scheduling of QC testing.
k. Attend weekly construction progress meetings as stated in Phase 2.
l. Provide field information for office staff to prepare weekly FAA progress reports as stated in
Phase 2.
m. Conduct labor interviews to , in
accordance with the Davis-Bacon Act requirements, and provide to office staff for certified
payroll review as stated in Phase 2.
n. Provide field information for office staff to prepare RFCPs, field directives, and CCOs as stated
in Phase 2.
o. Assist in preparing applications for payment as described in Phase 2. Throughout construction,
the CO and CO will check quantities as work is performed and communicate with the Contractor
to establish quantities that will be included in monthly progress billings.
p. Work with Contractor to markup construction Plans with field changes if applicable and provide
to office staff to prepare Record Drawings as described in Phase 5.
q. Receive from Contractor and review the required maintenance and operating instructions,
schedules, guarantees, bonds, inspection certificates, tests, approvals, and other relevant
documents.
Page 113 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 11 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
r. Identify punch list items in advance of the substantial completion walk-through to support
preparation of punch list as stated in Phase 2.
s. Attend the substantial completion walk-through as stated in Phase 2.
PHASE 4 MATERIAL TESTING
4.1 MATERIAL TESTING
The material testing services will be performed by the Contractor in conformance with the Project
Quality Control Specifications. The CONSULTANT will be responsible for coordinating and
scheduling QA by material testing witnessing throughout the construction duration.
CONSULTANT will provide an Electrical Senior Engineer to witness the necessary quality control
tests performed by the Contractor in accordance with the cited requirements and standard methods
of FAA, ASTM, and AASHTO; record test results on the appropriate forms; prepare a summary and
disposition of testing and material inspection; record deviating tests; conduct random material
observations and compare against product submittals required by the FAA and observe and
evaluate such tests made by the Contractor in the field, as necessary, in accordance with Plans
and Specifications. CONSULTANT to provide copies of test reports to the SPONSOR of
-compliance issues shall
immediately be reported to the Contractor and SPONSOR.
This scope assumes the following material testing and construction administration support by
CONSULTANT:
a. Review Contractor-submitted QC Program.
b. Attend pre-construction conference and QC/QA workshop.
c. Conduct site observations, provide recommendations, and perform testing observations for the
following Items as described in the Project Specifications:
(1) Item SP1-2.5, 10kW CCR:
Visit site to observe condition of connections and functioning of the lights at multiple
settings.
(2) Item L-108, Underground Power Cables for Airports, Section 108-2.9:
5kV Reel, before and after whole circuit testing, insulation testing, earth resistance
testing for ground rods and counterpoise.
(3) Item L-110, Airport Underground Electrical Duct Banks and Conduits:
Review plastic conduit, fittings and detectable warning tape to meeting specifications.
Compaction testing for soils, aggregates, and pavement.
(4) Item L-125, Installation of Airport Lighting System:
Electrical grounding and circuit testing.
(5) Prepare final QA report including the tests performed herein.
PHASE 4 DELIVERABLES
1) Quality Acceptance Reports Electronic files to SPONSOR and Contractor
Page 114 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 12 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
PHASE 5 POST-CONSTRUCTION SERVICES
5.1 PHASE 5 PROJECT MANAGEMENT
Project management tasks during Phase 5 will consist of the following:
5.1.1 Update Schedule
The schedule created during Phase 1 will be updated to show Project closeout
milestones.
5.1.2 Coordinate PMP Updates
The PM will continue to coordinate and monitor PMP during Phase 5.
5.1.3 Coordinate CONSULTANT Team
The PM will assign responsibilities to office staff to complete the documentation efforts
described herein. The PM will also coordinate with the CO for providing field data to
complete the documentation efforts described herein.
5.1.4 Coordinate QA
The PM will coordinate to complete final QA report.
5.1.5 Prepare Invoices
The PM will continue to maintain the Project budget table and prepare invoices as defined
in Phase 1. It is anticipated that three (3) invoices will be prepared during Phase 5.
5.2 PHASE 5 COMMUNICATION
The CONSULTANT will communicate with the SPONSOR and Contractor throughout Phase 5 as
needed via phone call or email.
5.3 RECORD DRAWINGS
The CO and Contractor will coordinate throughout construction to document field constructed
conditions and markup the construction Plans as stated in Phase 3. Upon completion of
construction, the CONSULTANT will prepare the Record Drawings using AutoCAD Civil 3D 2020,
by updating the drawing files created during design. The Drawings will become record information.
The CONSULTANT will provide the SPONSOR with a set of reproducible Record Drawings in both
digital and hardcopy format, as requested.
5.4 FINAL CONSTRUCTION REPORT (FCR)
Upon completion of construction, the CONSULTANT will prepare and assemble the FCR in
conformance with FAA standards and requirements. The contents of the report will include, but are
not limited to, the following:
a. Project Description and Overview
b. Project Personnel
c. Contract Award and NTP (Including Bid Tabulation, Contract, and NTP Letters as Appendices)
d. Project Timeline
e. Summary of Work Accomplished (Including Table of Work Activities and Weeks Performed, as
well as weekly FAA progress reports as Appendix)
f. Contract Time
g. Labor Provisions
Page 115 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 13 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
h. SPONSOR Administrative Costs
i. Consultant Costs
j. Force Account (if applicable)
k. Construction Costs (including Final Application for Payment and CCOs as Appendices)
l. Summary of DBE Utilization (including DBE Utilization Form as Appendix)
m. Buy American Provisions (including Submittal Checklist as Appendix)
n. Construction Material Testing and Acceptance (including QC and QA Test Results as
Appendices)
o. including Letter of Completion and
Warranty as Appendix)
p. Record of Completion (including Substantial Completion Letter and SPONSOR Notice of
Completion as Appendices)
q. FAA-Required Sponsor Certification of Final Construction Acceptance as Appendix. This
certification shall be signed by the SPONSOR.
r. Recommendations
The CONSULTANT will coordinate with the Contractor, SPONSOR, and FAA to complete Project
closeout activities and assemble the documents to be included in the FCR. The CONSULTANT will
submit a draft version of the FCR for SPONSOR review. Upon receipt of SPONSOR review /
comments, the CONSULTANT will finalize the FCR and submit to the SPONSOR and FAA.
5.5 AIRPORT LAYOUT PLAN (ALP) RECORD DRAWING UPDATE NIC
The Project does not include any elements that would apply to an ALP Record Drawing update.
5.6 UPDATE AIRFIELD PAVEMENT MANAGEMENT SYSTEM (APMS) - NIC
The CONSULTANT will not update the current APMS previously prepared. This Project does not
impact pavement conditions. It is anticipated that a complete APMS update will be performed under
a future contract.
5.7 UPDATE AIRFIELD SIGNAGE AND MARKING PLAN NIC
An airfield signage and marking plan is not required for this Airport.
5.8 AGIS AS-BUILT SURVEY NIC
Due to the nature of Project improvements, an AGIS survey will not be performed as part of this
Project.
PHASE 5 DELIVERABLES
1) Record Drawings reproducible hardcopy and electronic files to SPONSOR
2) FCR three (3) bound copies to SPONSOR and electronic file to SPONSOR and FAA
Page 116 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 14 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
SCHEDULE OF COMPLETION
Phases 1-4
The CONSULTANT will complete the work called for under Phases 1-4 on a schedule submitted by the
Contractor and approved by the SPONSOR not to exceed 60 working days.
Phase 5
The CONSULTANT will complete the work called for under Phase 5 within 30 working days of the receipt
of a copy of the Notice of Completion filed by the SPONSOR.
SERVICES TO BE PROVIDED BY THE SPONSOR AND EXCLUDED SERVICES
The SPONSOR and CONSULTANT agree that the following items will be provided by the SPONSOR or
excluded from this scope and, if added to the CONSULTANT , will be considered as extra services
and a negotiated fee will be established, and an Amendment prepared:
1) Issuing of Notices to Airmen (NOTAMs) and announcements regarding the impact of the Project on
aviation activities.
2) Guaranteed access to and make provisions for the CONSULTANT to enter the Airport as required for
the CONSULTANT to perform his work under this Agreement.
3) Examination of documents requested by the SPONSOR and presented by the CONSULTANT and
render in writing decisions pertaining thereto within a reasonable time so as not to delay the work of
the CONSULTANT.
4) Contract change orders that require new design elements beyond the scope of the awarded contract.
5) Extensions of construction time beyond the awarded contract timeframes.
6) FAA grant reimbursement submission.
7) Filing of Notice of Completion to the FAA.
COMPENSATION FOR SERVICES
1) The total amount for services described in this Scope of Services is Two Hundred
Forty-two Thousand Two Hundred Forty-six Dollars and Ninety Cents ($242,246.90). This fee
includes labor, materials, expenses, and incidentals necessary to complete the work as described
herein. Cost and payment are broken out as follows:
a. Lump Sum: Payment for work outlined in Phases 1 and 5 of this Scope of Services shall be
made on a lump sum basis in the amount of Seventy-nine Thousand Five Hundred Seventy-
eight Dollars and Eighteen Cents ($79,578.18). Payments will be made monthly based on the
percentage of work complete.
b. Time-and-expense: Payment for work outlined in Phases 2, 3, and 4 of this Scope of Services
shall be made on a time-and-expense basis not to exceed One Hundred Sixty-two Thousand
Six Hundred Sixty-eight Dollars and Seventy-two Cents ($162,668.72). Payments will be
made monthly based on the hours of work complete, in conformance with the Mead & Hunt, Inc.
Standard Billing Rate Schedule, effective January 1, 2022, included as Attachment 2.
These amounts shall not be exceeded without written authorization from the SPONSOR. The cost
breakdown is included as Attachment 1 to this Scope.
Page 117 of 390
Ukiah Municipal Airport Rwy 15-33 MIRLs, FAA PAPI and REILs
Construction Administration Scope of Services
October 18, 2022 Final
Page 15 of 15
\\corp.meadhunt.com\sharedfolders\entp\2112200\192335.02\CFEE\Proposal\UKI Runway 15-33 Phase 2 PAPIs and REILs Construction Admin Scope_Final_10-18-22.docx
2) Payment for any additional services requested by the SPONSOR will be performed on a time-and-
expense basis in conformance with the Mead & Hunt, Inc. Standard Billing Rate Schedule, effective
January 1, 2022, included as Attachment 2. The CONSULTANT will establish the budget for additional
services prior to the start of work and may not exceed the budget without written authorization from the
SPONSOR. Any additional services must be authorized in writing by the SPONSOR.
End of Scope of Services
Respectfully submitted by,
MEAD & HUNT, Inc.
Robert Casagrande
Senior Project Engineer
Attachments
Attachment 1 Construction Administration Cost Estimate
Attachment 2 - Mead & Hunt, Inc. Standard Billing Rate Schedule (2022)
Page 118 of 390
Page 119 of 390
Page 120 of 390
MEAD & HUNT, Inc.
Standard Billing Rate Schedule
Effective January 2022
Standard Billing Rates
Clerical ............................................................................................................................................... $90.00 / hour
Technical Editor ................................................................................................................................. $123.00 / hour
Senior Editor ...................................................................................................................................... $180.00 / hour
Registered Land Surveyor ................................................................................................................. $140.00 / hour
Accounting, Administrative Assistant ................................................................................................. $115.00 / hour
Technician I, Technical Writer ........................................................................................................... $107.00 / hour
Technician II, Surveyor - Instrument Person ..................................................................................... $124.00 / hour
Technician III ...................................................................................................................................... $144.00 / hour
Technician IV .................................................................................................................................... $151.00 / hour
Senior Technician .............................................................................................................................. $189.00 / hour
Engineer I, Scientist I, Architect I, Interior Designer I, Planner I ....................................................... $136.00 / hour
Engineer II, Scientist II, Architect II, Interior Designer II, Planner II ................................................... $151.00 / hour
Engineer III, Scientist III, Architect III, Interior Designer III, Planner III ............................................. $163.00 / hour
Construction Resident Project Representative (RPR) ...................................................................... $172.00 / hour
Senior Engineer, Senior Scientist, Senior Architect, Senior Interior Designer, Senior Planner,
Senior Economist .............................................................................................................................. $210.00 / hour
Project Engineer, Project Scientist, Project Architect, Project Interior Designer, Project Planner .... $221.00 / hour
Senior Project Engineer, Senior Project Scientist, Senior Project Architect,
Senior Project Interior Designer, Senior Project Planner ................................................................... $261.00 / hour
Senior Associate, Principal, Senior Client / Project Manager ............................................................ $337.00 / hour
Expenses
Geographic Information or GPS Systems ........................................................................................ $100.00 / day
Total Station Survey Equipment ....................................................................................................... $110.00 / day
Charges for other equipment may appear in a proposal
Out-Of-Pocket Direct Job Expenses ................................................................................................. cost plus 15%
Such as reproductions, sub-consultants / contractors, etc.
Travel Expense
Company or Personal Car Mileage................................................................................................... $ IRS rate / mile*
* Rates will be charged at Current IRS rate
Air and Surface Transportation ......................................................................................................... cost plus 15%
Lodging and Sustenance .................................................................................................................. cost plus 15%
Billing and Payment
Travel time is charged for work required to be performed out-of-office. A minimum of two hours will be billed
for any work out-of-office.
Invoicing is on a monthly basis for work performed. Payment for services is due within 30 days from the date
of the invoice. An interest charge of 1.5% per month is made on the unpaid balance starting 30 days after the
date of invoice.
This schedule of billing rates is effective January 1, 2022, and will remain in effect until December 31, 2022,
unless unforeseen increases in operational costs are encountered. We reserve the right to change rates to reflect
such increases.
Page 121 of 390
Independent Fee Estimate
Ukiah Municipal Airport
PHASES and TASKS
Se
n
i
o
r
A
s
s
o
c
i
a
t
e
Se
n
i
o
r
P
r
o
j
e
c
t
En
g
i
n
e
e
r
Pr
o
j
e
c
t
E
n
g
i
n
e
e
r
(C
i
v
i
l
o
r
E
l
e
c
t
r
i
c
a
l
)
Se
n
i
o
r
E
n
g
i
n
e
e
r
/
Pr
o
j
e
c
t
M
a
n
a
g
e
r
En
g
i
n
e
e
r
I
I
I
En
g
i
n
e
e
r
I
I
En
g
i
n
e
e
r
I
Te
c
h
n
i
c
i
a
n
I
I
/
Co
n
s
t
O
b
s
e
r
v
e
r
Ad
m
i
n
i
s
t
r
a
t
i
v
e
As
s
i
s
t
a
n
t
Cl
e
r
i
c
a
l
Mi
l
e
a
g
e
(P
e
r
M
i
l
e
)
Re
n
t
a
l
C
a
r
(P
e
r
D
a
y
)
Me
a
l
s
(P
e
r
D
i
e
m
)
Printing,
Shipping &
Other
Mead & Hunt, Inc. Standard Billing Rates 2022 $340 $260 $220 $205 $165 $150 $135 $125 $115 $85 $0.625 $71 $59.25 1
1.1 Phase 1 Project Management and Coordination
1.1.1 Prepare Contract and Project Setup 1 3 12 1 33.00$ 3,728.00$
1.1.2 Prepare Schedule 0.5 1 335.00$
1.1.3 Prepare Project Management Plan (PMP)1 4 1,080.00$
1.1.4 Coordinate CONSULTANT Team 0.5 2 4 1,510.00$
1.1.5 Coordinate Subconsultant - NIC -$
1.1.6 Prepare Invoices - Up to 1 Anticipated 0.5 1 1 450.00$
1.2 Phase 1 Project Meetings and Communication
1.2.1 Pre-Construction Conference 6 10 1 8 0.5 120 1 3 29.00$ 5,155.25$
1.2.2 Quality Control (QC) / Quality Assurance (QA) Workshop 1 2 1 795.00$
1.2.3 General Communication with SPONSOR and Contractor 2 6 1,750.00$
1.3 Prepare Project Documentation 1 3 6 5 2,400.00$
1.4 Review Material Submittals - Up to 19 Anticipated 3 6 30 6,510.00$
1.5 Prepare Construction Management Plan (CMP)1 2 4 27.00$ 1,297.00$
Phase 1 Subtotal 1.5 21 0 51 0 41 0 14 2 0.5 120 1 3 89.00$ 25,010.25$
2.1 Phase 2 Project Management and Coordination
2.1.1 Update Schedule 0.5 2 540.00$
2.1.2 Coordinate PMP Updates 1 2 670.00$
2.1.3 Coordinate CONSULTANT Team 1 3 12 3,580.00$
2.1.4 Coordinate Subconsultant - NIC -$
2.1.5 Prepare Invoices - Up to 3 Anticipated 0.5 1.5 3 3 14.00$ 1,534.00$
2.2 Phase 2 Project Meetings and Communication
2.2.1 Weekly Const Progress Meetings - Up to 5 Anticipated 2.5 35 40 2.5 600 5 10 20.00$ 15,380.00$
2.2.2 Site Visits During Construction - (included in 2.2.1)0 0 -$
2.2.3 General Communication with Sponsor and Contractor 6 12 4,020.00$
2.3 Weekly Working Day Reports - Up to 9 Anticipated 1.5 4.5 1,312.50$
2.4 Weekly FAA Progress Reports - Up to 4 Anticipated 2 5 1,545.00$
2.5 Requests for Information (RFIs) - Up to 5 Anticipated 2.5 5 1,675.00$
2.6 General Field Coordination 4 10 3,090.00$
2.7 Requests for Cost Proposals (RFCPs) - Up to 2 Anticipated 1 4 1 1,230.00$
Date:
Total Cost
7/28/2022
Mead & Hunt (labor hours and rates)
Runway 15-33 MIRL, FAA PAPI, and REIL Installation - Phase 2
Expenses
PHASE 1 - PRE-CONSTRUCTION SERVICES
PHASE 2 - CONSTRUCTION ADMINISTRATION SERVICES
IFE Hours & Fees Page 1
Attchment 2
Page 122 of 390
Independent Fee Estimate
Ukiah Municipal Airport
PHASES and TASKS
Se
n
i
o
r
A
s
s
o
c
i
a
t
e
Se
n
i
o
r
P
r
o
j
e
c
t
En
g
i
n
e
e
r
Pr
o
j
e
c
t
E
n
g
i
n
e
e
r
(C
i
v
i
l
o
r
E
l
e
c
t
r
i
c
a
l
)
Se
n
i
o
r
E
n
g
i
n
e
e
r
/
Pr
o
j
e
c
t
M
a
n
a
g
e
r
En
g
i
n
e
e
r
I
I
I
En
g
i
n
e
e
r
I
I
En
g
i
n
e
e
r
I
Te
c
h
n
i
c
i
a
n
I
I
/
Co
n
s
t
O
b
s
e
r
v
e
r
Ad
m
i
n
i
s
t
r
a
t
i
v
e
As
s
i
s
t
a
n
t
Cl
e
r
i
c
a
l
Mi
l
e
a
g
e
(P
e
r
M
i
l
e
)
Re
n
t
a
l
C
a
r
(P
e
r
D
a
y
)
Me
a
l
s
(P
e
r
D
i
e
m
)
Printing,
Shipping &
Other
Mead & Hunt, Inc. Standard Billing Rates 2022 $340 $260 $220 $205 $165 $150 $135 $125 $115 $85 $0.625 $71 $59.25 1
Date:
Total Cost
7/28/2022
Mead & Hunt (labor hours and rates)
Runway 15-33 MIRL, FAA PAPI, and REIL Installation - Phase 2
Expenses
2.8 Field Directives - Up to 2 Anticipated 1 4 1 1,230.00$
2.9 Contract Change Orders (CCOs) - Up to 2 Anticipated 2 6 8 31.00$ 2,981.00$
2.10 Review of QC / QA Test Results 1 2 670.00$
2.11 Certified Payroll and Davis Bacon items - Up to 10 weeks 5 15 3,050.00$
2.12 Monthly Applications for Payment - Up to 4 Anticipated 2 6 10 27.00$ 3,277.00$
2.13 Substantial Completion Walk-Through & Documentation
2.13.1 Substantial Completion Walk-Through 6 120 1 1 1,435.25$
2.13.2 Punch List and Substantial Completion Letter 0.5 2 540.00$
Phase 2 Subtotal 1.5 32 0 125.5 0 60 15 0 3 2.5 720 6 11 92.00$ 47,759.75$
3.1 Daily Construction Observation 40 240 3920 28 28 41,497.00$
Phase 3 Subtotal 0 0 0 0 0 0 40 240 0 0 3920 28 28 -$ 41,497.00$
4.1 Material Testing - (witness testing)18 360 3 3 4,305.75$
Phase 4 Subtotal 0 0 0 18 0 0 0 0 0 0 360 3 3 -$ 4,305.75$
5.1 Phase 5 Project Management and Coordination
5.1.1 Update Schedule 0.5 1 335.00$
5.1.2 Coordinate PMP Updates 1 2 670.00$
5.1.3 Coordinate CONSULTANT Team 0.5 3 5 1,975.00$
5.1.4 Coordinate QA 0.5 2 540.00$
5.1.5 Prepare Invoices - Up to 3 Anticipated 1.5 3 3 14.00$ 1,364.00$
5.2 Phase 5 Communication 1 4 1,080.00$
5.3 Record Drawings 2 6 12 4 1 151.00$ 4,106.00$
5.4 Final Construction Report (FCR)1 2.5 6 16 1 44.00$ 4,749.00$
5.5 Airport Layout Plan (ALP) Record Drawing Update - NIC -$
5.6 Update Airfield Pavement Mgmt System (APMS) - NIC -$
5.7 Update Airfield Signage and Marking Plan - NIC -$
5.8 AGIS As-Built Survey - NIC -$
Phase 5 Subtotal 1.5 12 0 29 0 16 12 4 3 2 0 0 0 209.00$ 14,819.00$
133,391.75$ TOTAL PROJECT BUDGET
PHASE 3 - CONSTRUCTION OBSERVATION
PHASE 4 - MATERIAL TESTING - NIC
PHASE 5 - POST-CONSTRUCTION SERVICES
IFE Hours & Fees Page 2
Page 123 of 390
Page 1 of 1
Agenda Item No: 7.c.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2120
AGENDA SUMMARY REPORT
SUBJECT: Consideration of Approval of a Budget Amendment for the Ukiah Valley Fire Authority (UVFA)
Supplies and Maintenance Accounts.
DEPARTMENT: Finance PREPARED BY: Jessie Brunell, Senior Accountant
PRESENTER: Dan Buffalo, Finance Director
ATTACHMENTS:
None
Summary: Council will consider approving amending the budget for the Ukiah Valley Fire Authority (UVFA)
building maintenance and supplies accounts.
Background: Furniture purchases and maintenance activities at the North Fire Station located on Lovers Lane
were budgeted and intended to be incurred in the prior fiscal year, but were delayed at year-end. Those costs
were instead incurred in the current fiscal year, requiring a subsequent budget adjustment.
Discussion: Staff recommends that the City Council approve a budget amendment in the amount of $7,715
for the UVFA building and maintenance account needed to address planned but delayed general maintenance
activities at the station and $3,100 for the Ambulance supplies account for new furniture to accommodate
recently hired personnel.
Recommended Action: Approve amending the budget for an increase of $7,715 for the Ukiah Valley Fire
Authority (UVFA) building maintenance account and $3,100 for the Ambulance supplies account for residual
expenditures meant to be incurred in FY 2021-22.
BUDGET AMENDMENT REQUIRED: Yes.
CURRENT BUDGET AMOUNT: 10521210.56300: $40,000; 71021100.54100: $9,500
PROPOSED BUDGET AMOUNT: 10521210.56300: $47,715; 71021100.54100: $12,600
FINANCING SOURCE: Departmental Budgetary Surplus from FY 2022
PREVIOUS CONTRACT/PURCHASE ORDER NO.: PO #48106; PO #48104
COORDINATED WITH: Eric Singleton, Battalion Chief; Dan Buffalo, Finance Director
Page 124 of 390
Page 1 of 1
Agenda Item No: 7.d.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2151
AGENDA SUMMARY REPORT
SUBJECT: Review Landfill Closure Financial Plan Update.
DEPARTMENT: Finance PREPARED BY: Dan Buffalo, Finance Director
PRESENTER: Consent Calendar
ATTACHMENTS:
1. Resolution No. 2016-03 - Establishing Funding Closure-Ukiah Solid Waste Disposal
2. Signed Landfill Inflation Form
Summary: The City Council will receive an update on the Financial Plan of 2016 to finance closure, post-
closure, and a corrective action plan of the Ukiah Landfill.
Background: The City Council, at its regularly scheduled meeting of January 6, 2016, considered a strategy
to provide funding for the ultimate closure, post closure, and Corrective Action Plan (CAP) reserve of the
Ukiah Landfill. The strategy was memorialized in the City Council Resolution No. 2016-03 (Attachment 1). The
Resolution directs the Finance Director to present to Council, for consideration annually, the condition of the
financial plan, with any recommended adjustments.
Discussion: Costs to conduct closure, post-closure, and prepare a corrective action plan have been adjusted
by an inflationary index provided by CalRecycle. For 2022 the estimated cost with an assumed inflationary
adjustment of 4.1 percent from 2021 is $20,539,939. The change in cost is due to the annual inflation factor
provided by CalRecycle. The Finance Department, in coordination with Public Works and the City Manager's
Office, continues to revise the City's financing strategy to meet this obligation in full, using a combination of
reserves and cash inflows from surcharges collected at the transfer station.
Detail of the calculation and the breakdown by the various categories of closure are included in Attachment 2.
Recommended Action: Receive and file update to the Landfill Closure Financial Plan.
BUDGET AMENDMENT REQUIRED: No
CURRENT BUDGET AMOUNT: N/A
PROPOSED BUDGET AMOUNT: N/A
FINANCING SOURCE: N/A
PREVIOUS CONTRACT/PURCHASE ORDER NO.: N/A
COORDINATED WITH: Tim Eriksen, Public Works Director/City Engineer
Page 125 of 390
1
1
1
RESOLUTION NO. 2016-03
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF UKIAH ESTABLISHING
FINANCIAL MECHANISM FOR FUNDING CLOSURE, POST - CLOSURE MAINTENANCE,
AND CORRECTIVE ACTION PLAN FOR CITY OF UKIAH SOLID WASTE DISPOSAL SITE
WHEREAS:
1. The City of Ukiah solid waste disposal site ( "Landfill ") located at 3100 Vichy Springs Road,
Mendocino County Assessor Parcel No. 178- 130 -01), consisting of a landfill footprint of
approximately 40 acres, ceased operations and accepting solid waste in September 2001; and
2. Since September 2001, the City has maintained the Landfill, including monitoring wells
surrounding the perimeter of the property and a leachate collection system that captures and
disposes of leachate through the City's sewer system; and
3. Under applicable provisions of the California Public Resources Code and in Title 27 of the
California Code of Regulations ( "CCR "), the City is required to adopt a plan for the closure, post -
closure maintenance, and corrective actions required for the Landfill; and
4. Pursuant to 27 CCR 21180(a), the City must provide post - closure maintenance and a
corrective action plan reserve ( "CAP ") for a thirty -year period after closure; and
5. The cash collected by the City to provide for Closure, Post - Closure Maintenance, and the
CAP reserve are reflected in the City's financial statements as a net position of the disposal site
proprietary fund; and
6. The City is scheduled to complete the closure of the landfill ( "Closure ") in accordance with its
approved closure plan in 2016; and
7. Recently, new and more costly regulatory requirements relating to Closure have been
imposed by the California state agencies with jurisdiction over the Closure. These additional
requirements, including installation of a methane gas collection system, would have been
imposed, even if the Closure had occurred prior to the imposition of these new requirements;
and
8. The most recent engineer's estimates for Closure, including the gas collection system and
other additional requirements, indicate that the net proprietary fund for the Landfill is not
sufficient to cover all of the costs of Closure, Post - Closure Maintenance, and to establish a
CAP reserve; and
9. The City must provide the funding for Closure, Post - Closure Maintenance, and the CAP
reserve; and
10. On January 1, 2017, pursuant to the Amended and Restated Transfer Station Agreement
Transfer Station Agreement ") between the City of Ukiah and Solid Waste Systems, Inc.
SWS "), dated December 12, 2011, the City is entitled to acquire legal title to the Transfer
Station (Transfer Station) located at 3151 Taylor Drive, Ukiah, California, and the City and SWS
are obligated to enter a lease under which SWS will continue to operate the transfer station and
pay rent ( "Transfer Station Rent ") to the City for the use of the Transfer Station; and
1
Page 126 of 390
10. Dedicating Transfer Station Rent to fund Closure, Post - Closure Maintenance, and the Cap
Reserve as further provided herein will provide a source of revenue to fund those obligations
which exceed the disposal site proprietary fund; and
11. Commencing on January 1, 2012, the City adopted a City Surcharge on the Gate Fee at the
Transfer Station ( "Surcharge ") to provide a source of revenue in the Landfill /Solid Waste
Enterprise Fund for Closure and Post - Closure Maintenance, and the CAP reserve. The
Surcharge is currently $2.00 per ton of Solid Waste received at the Transfer Station. The
Surcharge is collected by SWS and remitted to the City, where it is recorded as revenue in the
Landfill /Solid Waste Enterprise Fund as Closure and Post - Closure Reserve; and
12. Committing the Surcharge at its current level or any future level approved by the City
Council will stabilize the Landfill /Solid Waste Enterprise Fund, provide a dedicated source of
revenue to comply with the City's Closure and Post - Closure Maintenance costs, and the
establishment and replenishment of the Cap Reserve; and
13. The combination of the disposal site proprietary fund, Transfer Station Rent, and the
Surcharge will provide adequate funding for City's Closure and Post - Closure Maintenance
costs, and the establishment and replenishment of the Cap Reserve, provided however, that an
increase in the Surcharge may be necessary once the final Closure costs and the method of
financing the City's obligations is determined;
NOW, THEREFORE, BE IT RESOLVED, by the City Council of the City of Ukiah as follows:
1. Transfer Station Rent is hereby committed to any unfunded Closure costs, Post - Closure
Maintenance costs, and the establishment and replenishment of the CAP reserve.
2. There is hereby established a Transfer Station Rents Special Revenue Fund (Special
Revenue Fund) for all Transfer Station Rent revenue which fund is established and dedicated to
pay for any Closure costs, Post - Closure Maintenance costs, and the establishment and
replenishment of the CAP reserve.
3. Revenue recorded in the Special Reserve Fund shall be given first preference over other
revenue sources, other than grants, in funding Closure and Post - Closure Maintenance
expenses and CAP reserve requirements that are not funded by the disposal site proprietary
fund.
4. Any Closure and Post - Closure Maintenance expenses and CAP reserve requirements not
funded by grants, the disposal site proprietary fund, and the Special Revenue Fund shall be
funded by the Surcharge.
5. The City Finance Director is hereby directed to prepare for City Council the approval a
Financial Plan (Plan) to extinguish in fifteen years the estimated unfunded Closure and thirty -
year Post - Closure Maintenance costs, and the CAP reserve requirements, and present the
Surcharge to be applied to the Transfer Station Gate Fee commencing on January 1, 2017. The
revised Surcharge shall be submitted to the City Council for approval no later than October
2016. Thereafter, in September of each year, the City Finance Director shall prepare an update
of the Plan to fund Closure, Post - Closure Maintenance, and CAP requirements. Any
recommended increase or decrease in the Surcharge resulting from the annual update of the
Plan shall be presented to the City Council for approval in October, and if approved, will be
applied to the Transfer Station Gate Fee immediately following January 1st.
2
1
1
1
Page 127 of 390
1
1
1
PASSED AND ADOPTED this 6th day of January 2016, by the following roll call vote:
AYES: Councilmember Crane, Mulheren, Doble, Brown, and Scalmanini.
NOES: None
ABSTAIN: None
ABSENT: None
ATTEST:
Kristine Lawler, City Clerk
Stephen G. Scalmanini, Mayor
Page 128 of 390
Attachment 2
Page 129 of 390
Attachment 2
Page 130 of 390
Attachment 2
Page 131 of 390
Attachment 2
Page 132 of 390
Page 1 of 2
Agenda Item No: 7.e.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2153
AGENDA SUMMARY REPORT
SUBJECT: Approval of Notice of Completion for Wahlund Construction Inc. for the Ford and Orchard Lift
Station Replacement, Specification 22-02, and Direct the City Clerk to File the Notice of Completion with the
County Recorder.
DEPARTMENT: Public Works PREPARED BY: Seth Strader, Administrative Analyst
PRESENTER: Tim Eriksen, Director of Public Works
ATTACHMENTS:
1. Approving Staff Report
2. Notice-of-Completion
Summary: Council will consider approving the Notice of Completion for the Ford and Orchard Lift Station
Replacement, Specification 22-02 and approve final payment of the 5% retention to Wahlund Construction Inc.
Background: The Public Works Department has completed the replacement of the mechanical and control
equipment of the Ford and Orchard Lift Station. Also included was wet well epoxy coating, site fencing, traffic
bollards and underground electric conduit for future development.
Discussion: At the June 1, 2022, City Council meeting Council had awarded the Ford and Orchard Lift Station
Replacement to Wahlund Construction Inc. in the amount of $220,775. The contract price was based on the
engineer’s estimate provided in the bid package (Attachment 1).
The project cost increased due to additional construction services that were not included in the original
contract but were found necessary during the course of project work. This includes additional vault upgrades
resulting in a revised total contract amount of $237,613.62.
The contract work was completed in conformance with the Project Plans on October 20, 2022. Final payment
of the retention will be made to the contractor after 35 days from the date the Notice of Completion
(Attachment 2) is filed with the County Recorder.
Recommended Action: Approve Notice of Completion for the Ford and Orchard Lift Station Replacement,
Specification 22-02, and direct the City Clerk to file the Notice of Completion with the County Recorder.
BUDGET AMENDMENT REQUIRED: N/A
CURRENT BUDGET AMOUNT: N/A
PROPOSED BUDGET AMOUNT: N/A
FINANCING SOURCE: N/A
PREVIOUS CONTRACT/PURCHASE ORDER NO.: 2122242
COORDINATED WITH: Tim Eriksen, Director of Public Works and Jason Benson, Senior Engineer
Page 133 of 390
Page 2 of 2
Page 134 of 390
Page 1 of 2
Agenda Item No: 7.i.
MEETING DATE/TIME: 6/1/2022
ITEM NO: 2022-1700
AGENDA SUMMARY REPORT
SUBJECT: Consideration of Award of Bid to Wahlund Construction, Inc. in the Amount of $220,775 for the
Ford and Orchard Lift Station Replacement Specification No. 22-02.
DEPARTMENT:Public Works PREPARED BY:Seth Strader, Administrative Analyst
PRESENTER:Tim Eriksen, Director of Public Works
ATTACHMENTS:
1.Bid Notice
2.Bid Tabulation
3.Wahlund Bid
Summary: Council will consider awarding a contract to Wahlund Construction in the amount of $220,775 for
Ford and Orchard Lift Station Replacement, Specification No. 22-02.
Background: It was determined that the existing lift station at Ford and Orchard that serves the Wagenseller
and surrounding communities has begun to fail. Both the pumps and control system are at end of life and
need replacement.
In addition to the lift station mechanical and control equipment replacement - and other improvements such as
wet well epoxy coating, site fencing, and traffic bollards - Public Works Staff coordinated with the Electric
Utility Department and included the installation of new primary underground electric conduits under Orchard
Avenue for future development.
Discussion: The City released the bid notice (Attachment 1) in April and interested contractors participated in
a bid walk for the project on May 3, 2022. The City received three construction bids for this project on May 18,
2022 (Bid Tabulation is Attachment 2). Wahlund Construction was the low bidder with a bid amount of
$220,775.
It is Staff's recommendation to award the bid (Attachment 3) for Specification No. 22-02 for the Ford and
Orchard Lift Station Replacement in the amount of $220,775 to Wahlund Construction, Inc.
An internal budget transfer will be performed to link budgeted Electric Utility Department funds to the Project
Code associated with the replacement project. (18134)
Recommended Action: Approve award of a contract to Wahlund Construction, Inc. in the amount of
$220,775.00 for the Ford and Orchard Lift Station Replacement, Specification No. 22-02.
BUDGET AMENDMENT REQUIRED: NO
CURRENT BUDGET AMOUNT: 84027221.80100.18134: $200,000 80126100.80230.18034: $0
PROPOSED BUDGET AMOUNT: 84027221.80100.18134: $170,825 80126100.80230.18134: $49,950 (by
internal transfer from PC 18044)
FINANCING SOURCE: N/A
PREVIOUS CONTRACT/PURCHASE ORDER NO.: N/A
ATTACHMENT 1
Page 135 of 390
Page 2 of 2
COORDINATED WITH: Tim Eriksen, Director of Public Works; Cindy Sauers, Electric Utility Director; Jason
Benson, Senior Engineer; Sonu Upadhyay, Senior Power Engineer; and Mary Horger, Financial Services
Manager.
Page 136 of 390
Please return to:
CITY OF UKIAH
300 Seminary Avenue
Ukiah, California 95482-5400
(707) 463-6200
NOTICE OF COMPLETION
NOTICE IS HEREBY GIVEN:
1.That the project described as: Ford and Orchard Lift Station Replacement, Specification No. 2022-02
2.That the nature of the title to the mechanical and control equipment replacement at the Ford and Orchard
Lift Station.
3.That on the 20th day of October 2022, the Contract work for this project was actually completed.
4.That the name and address of the Contractor is Wahlund Construction Inc., PO Box 6486 Eureka, CA
95502
5.That the real property herein referred to is situated in the County of Mendocino, State of California, and
is described as follows: City-owned property identified as the Ford and Orchard Lift Station.
I hereby certify under penalty of perjury that the forgoing is true and correct:
City Council Approval CITY OF UKIAH, a Municipal Corporation
_________________ By: __________
Date Kristine Lawler, City Clerk Date
State of California
County of Mendocino
Exempt from recording fees pursuant to Government Code Section 27383
ATTACHMENT 2
Page 137 of 390
Page 1 of 1
Agenda Item No: 7.f.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2166
AGENDA SUMMARY REPORT
SUBJECT: Report of Additional Amount for New 2023 Ford F-150 (All Electric) Lighting Pro Series Crew Cab,
and Approve Corresponding Budget Amendment.
DEPARTMENT: Finance PREPARED BY: David Mendez, Buyer II
PRESENTER: Neil Davis, Community Services Director
ATTACHMENTS:
1. PO 47870
2. Updated Quote Redwwod Ford
Summary: Council will receive a report regarding the additional funds needed for the purchase of one (1)
2023 Ford F-150 (All Electric) Lighting Pro Series Crew Cab Truck.
Background: On April 20, 2022, City Council approved the purchase of one (1) 2022 Ford F-150 (All Electric)
Lightning Pro Series Crew Cab Truck for the amount of $43,729.28 for the Parks Department.
Discussion: Staff issued Purchase Order 47870 (Attachment 1) to Redwood Ford of Ukiah for one (1) 2022
Ford F-150 (All Electric) Lighting Pro Series Crew Cab Truck for the amount of $43,729.28. Following the
order placement, Redwood Ford notified the City Staff that the Ford plant had stopped production of the 2022
models. Staff received the updated cost (Attachment 2) from Redwood Ford for the new 2023 Ford F-150
Lighting Pro Series Crew Cab Truck for the amount of $51,158.46. The difference is $7,429.18. A budget
amendment is necessary to cover this increase.
Recommended Action: Receive the report, and approve the requested budget amendment.
BUDGET AMENDMENT REQUIRED: Yes
CURRENT BUDGET AMOUNT: 10022100.80100.V3765: $0
PROPOSED BUDGET AMOUNT: 10022100.80100.V3765: $7,429.18
FINANCING SOURCE: General Fund
PREVIOUS CONTRACT/PURCHASE ORDER NO.: PO 47870
COORDINATED WITH: Dave Kirch, Fleet/Plant/Building Maintenance Supervisor; Mary Horger, Financial
Services Manager
Page 138 of 390
Page 139 of 390
Page 140 of 390
Page 1 of 2
Agenda Item No: 7.g.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2167
AGENDA SUMMARY REPORT
SUBJECT: Approval of a Second Contract Amendment with GHD Inc. for Professional Engineering Services for
a Future Water Storage Tank Siting Study and Analysis, in the Amount of $20,000.
DEPARTMENT: Public Works PREPARED BY: Seth Strader, Administrative Analyst
PRESENTER: Tim Eriksen, Director of Public Works
ATTACHMENTS:
1. Contract No. 2021-112
2. Contract No. 2021-112-A1
3. 2022-08-04 Ukiah Tank Siting Study - GHD Proposal
Summary: Council will consider approving a second contract amendment with GHD Inc. for professional
engineering services for a future water storage tank siting study and analysis, in the amount of $20,000.
Background: On August 27, 2020, GHD Engineers, Inc began professional engineering services for a siting
study for a water storage tank. (Attachment 1). Design work was added to the original agreement for the
additional study of two possible tank sites including access, tank water supply and interconnection with
existing City utilities (Attachment 2).
Discussion: GHD Inc. performed an initial desktop GIS analysis of potential tank sites which was followed by
a detailed planning study that investigated tank types, siting, sizing and hydraulic analysis.
This additional study will look in greater detail at the siting of proposed 1.5 million gallon storage tanks at Site
1 as well as more detail of system operations with higher or lower tanks and, if it is possible, a tank could be
sited to match the pressure already existing in Zone 1, eliminating the need for the installation of a booster
pump station (Attachment 3).
This second amendment will bring the contract to a not-to-exceed amount of $42,123.89.
Recommended Action: Approve a second contract amendment with GHD Inc. for professional engineering
services for a future water storage tank siting study and analysis, in the amount of $20,000.
BUDGET AMENDMENT REQUIRED: NO
CURRENT BUDGET AMOUNT: 82027110.52100: $127,116.46
PROPOSED BUDGET AMOUNT: N/A
FINANCING SOURCE: N/A
PREVIOUS CONTRACT/PURCHASE ORDER NO.: 2021112
COORDINATED WITH: Tim Eriksen, Director of Public Works and Jason Benson, Senior Engineer
Page 141 of 390
Page 2 of 2
Page 142 of 390
ATTACHMENT 1
Page 143 of 390
Page 144 of 390
Page 145 of 390
Page 146 of 390
Page 147 of 390
Page 148 of 390
Page 149 of 390
Page 150 of 390
Page 151 of 390
Page 152 of 390
Page 153 of 390
ATTACHMENT 2
Page 154 of 390
Page 155 of 390
Page 156 of 390
Page 157 of 390
Page 158 of 390
Page 159 of 390
Page 160 of 390
The Power of Commitment
GHD
2235 Mercury Way, Suite 150
Santa Rosa, California 95407
United States
www.ghd.com
Your ref: 2021-112-A1
Our ref: 11217088
August 04, 2022
Tim Eriksen, PE
Director of Public Works/City Engineer
Public Works Department
City of Ukiah
300 Seminary Avenue
Ukiah, CA 95482-5400
RE: Proposal for Professional Engineering Services: Siting and Analysis of Water Storage, Pumping
and Transmission System
Dear Mr. Eriksen:
GHD is pleased to provide this proposal for professional engineering services for the siting and analysis of new
water storage tanks, including mains and the need for pumping systems in areas south and west of the City
limits. The purpose of the project is to provide municipal water service to proposed future residential
developments and to augment existing water storage for the City. The City is working with a developer of an
area in the hills west of the City limits, and the development of the property requires water storage
infrastructure. The City would also like to augment its existing storage to increase fire protection and to provide
operational flexibility with the other tanks in the system.
Background
GHD performed an initial desktop GIS analysis of a storage system, potential tank sites and service area
pressures, and summarized the results in a technical memorandum dated September 18, 2020. This
memorandum was followed by a detailed planning study that investigated tank types, tank siting, tank sizing
and hydraulic analysis of four potential sites as well as interconnections with the City’s existing distribution
system. The purpose of the second study was to provide technical information and planning level costs so the
City can make informed decisions regarding the design and construction of one or more new water storage
tanks. The results of the study were summarized in a technical memorandum dated December 20, 2020.
This current study will look in greater detail at the siting of proposed 1.5 million gallon (MG) storage tanks
located at Site 1. The elevation of Site 1 is higher than the City’s other water tanks, and the City would like to
look in greater detail at system operations with higher tanks, and whether there is a feasible site at a lower
elevation where the tanks could be sited so they can “float” with the City’s other tanks in the Zone 1 pressure
zone, thereby eliminating the need for one or more booster pump stations and pressure reducing stations.
ATTACHMENT 3
Page 161 of 390
11217088 | RE: Proposal for Professional Engineering Services: Siting and Analysis of Water Storage, Pumping and Transmission System 2
Scope of Services
The Scope of Services proposed is to perform an update of the siting and hydraulic analysis summarized in a
technical memorandum dated December 20, 2020, with specific focus on the tanks to be located at Site 1, and
to determine whether there are any other feasible sites at a lower elevation.
The purpose of this task is to develop alternatives for storage, water main alignments, interconnections
between the proposed tanks and City water system, and establish the design basis referencing the analysis
results and recommendations developed in Technical Memorandum No. 2 for the Water Tank Planning.
A draft basis of design (BOD) report will be prepared to confirm the design concept, summarize the design
criteria, and investigate alternatives for interconnecting the tanks with the City’s existing water system and
existing Zone 1 tanks, updated hydraulic analysis for the system, determine the need for booster pumps, and
capture the recommendations and City input. GHD will assess the design criteria and City’s requirements,
including applicable standards, and other recommendations. GHD will prepare a draft BOD report including the
tank siting and analysis results including requirements and recommendations for the following:
– Siting options and recommended Site 1 tank siting
– Need for booster pump station at the west end of Redwood Avenue
– Redwood Avenue water main replacement
– Water tank interconnections
– Connection alternatives to the City’s water system
– Need for Pressure Reducing Valves (PRVs) and Check Valves (CVs)
– Updated hydraulic analysis
The draft BOD report will include a recommended project and will be submitted to the City comments. The
report will be updated to address comments and incorporate more detailed design information during the
design phase of the project.
Fee Proposal
Our understanding is that the contract mechanism will be through an amendment to the existing Professional
Service Agreement for this project. GHD proposes to complete the Scope of Services for the time-and-
materials fee not to exceed $20,000.00 without the prior written authorization of the City. Services not included
in this proposal can be provided by a negotiated fee at current rates.
We welcome the opportunity to continue working with the City of Ukiah on this important project and look
forward to contributing to its success. Should you have any questions, please do not hesitate to contact me.
Respectfully Submitted,
Matthew Kennedy, PE, TE
Principal Engineer
+1 707-540-3376
matt.kennedy@ghd.com
Copy to: Jason Benson
Page 162 of 390
Page 1 of 2
Agenda Item No: 7.h.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2168
AGENDA SUMMARY REPORT
SUBJECT: Report of the Acquisition of Two Diesel-Powered Emergency Intertie Pumps From Pac Machine
Co. in the Amount of $294,083.25, and Approve Corresponding Budget Amendment.
DEPARTMENT: Water Resources PREPARED BY: Seth Strader, Administrative Analyst, Sean White,
Water Resources Director
PRESENTER: Sean White, Water Resources Director
ATTACHMENTS:
1. Grant Authorization
2. PO 40111
Summary: Council will receive a report of the acquisition of two diesel-powered emergency intertie pumps
from Pac Machine Co. in the amount of $294,083.25, and approve the corresponding budget amendment.
Background: On December 15, 2021, Council authorized the City Manager or designee (Attachment 1) to
pursue grant funding for the purchase of two mobile, trailer-mounted pumps that can be used to connect the
existing City tanks to both the Millview Water and Willow Water systems. These would allow the different water
districts to be able to share water with each other to meet the needs of their customers in an emergency
drought situation or if water utilities are lost or shutoff due to a wildfire. The City of Ukiah was successful, and
the grant was awarded.
Discussion: Water Staff independently placed the order for the pumps with Pac Machine Co. in the amount of
$294,038.25. The two pumps arrived in late summer of 2022 and were tested by a combination of City,
Millview and Willow Water Staff to test that the machines and systems were ready if needed in an emergency.
Please see Attachment 2 for a copy of the confirming Purchase Order 40111 based on the invoice received
from Pac Machine Co. The grant funds received by the City covered $264,600.00, but did not cover the
additional expense of freight and tax. The Water fund will be covering the remaining $29,438.25 of the
purchase.
Since this was not formally budgeted, Staff requests a budget amendment of $294,083.25 to be approved, as
well as amending the budget in the offsetting grant revenue account in the amount of $264,600.
Recommended Action: Council will receive a report of the acquisition of two diesel-powered emergency
intertie pumps from Pac Machine Co. in the amount of $294,083.25, and consider approving a corresponding
budget amendment.
BUDGET AMENDMENT REQUIRED: Yes
CURRENT BUDGET AMOUNT: 82027113.56120.18382: $0; 82000000.43190.18382: $0
PROPOSED BUDGET AMOUNT: 82027113.56120.18382: $294,083.25; 82000000.43190.18382: $264,600
FINANCING SOURCE: Water Reserve Funds
PREVIOUS CONTRACT/PURCHASE ORDER NO.: 40111
COORDINATED WITH: Sean White, Water & Sewer Director
Page 163 of 390
Page 2 of 2
Page 164 of 390
ATTACHMENT 1
Page 165 of 390
Purchase Order
Purchase
Order #
THIS NUMBER MUST APPEAR ON ALL INVOICES,
PACKAGES AND SHIPPING PAPERS.
Fiscal Year Page of
Delivery must be made within
doors of specified destination.
PO TotalRECEIVING COPY
BILL TO
V
E
N
D
O
R
SHIP
TO
Date OrderedVendor Phone Number Date RequiredVendor Fax Number Buyer
Item#Description/Part No.Unit Price Extended PriceUOMQty
CITY OF UKIAHATTN: ACCOUNTS PAYABLE300 SEMINARY AVENUEUKIAH, CA 95482
Freight Method/TermsDelivery Reference Department/Location Sales Tax Rate
2023 1 1
40111-00
PAC MACHINE CO INC8570 23RD AVESACRAMENTO CA 95826-4902
CITY OF UKIAH - CORPORATION YD1320 AIRPORT ROADUKIAH CA 95482
10/26/2022916-387-1336 Seth Strader
0.000WATER DISTRIBUTIONDAVE KIRCH
$294,083.25
1 2.0 EACH $132,300.000 $264,600.00GOULDS 3656 END SUCTION CENTRIFUGAL PUMP,
MODEL #20BFSAE2A3R
820.50.00.27.271.2711.27113.56120.18382 $264,600.00
2 6000.0 DOLL $1.000 $6,000.00FREIGHT
820.50.00.27.271.2711.27113.56120.18382 $6,000.00
3 23483.3 DOLL $1.000 $23,483.25SALES TAX @ 8.875%
820.50.00.27.271.2711.27113.56120.18382 $23,483.25
REF REQ E40111
PER INVOICE #87645 DATED 8/17/22
TO BE REPORTED TO COUNCIL: 11/2/22
ATTACHMENT 2
Page 166 of 390
Page 1 of 2
Agenda Item No: 7.i.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2192
AGENDA SUMMARY REPORT
SUBJECT: Approval of Notice of Completion for EIDIM Group, Inc. for the Council Chambers AV
Replacement Project, Specification No. 20-09, and Direct the City Clerk to File the Notice of Completion with
the County Recorder, and Approve Budget Amendment.
DEPARTMENT: City Clerk PREPARED BY: Kristine Lawler, City Clerk
PRESENTER: Kristine Lawler, City Clerk
ATTACHMENTS:
1. Spec 20-09 Council Chambers AV Replacement
2. Change Order #1 - Increase in contract days
3. Change Order #2 - Additional work - Revised
4. Change Order #3 - Additional control programming
5. Notice-of-Completion
Summary: The City Council will consider approving a Notice of Completion for EIDIM Group, Inc. for the
Council Chambers AV Replacement Project, Specification No. 20-09, and approval of a budget amendment.
Background: The Chambers Upgrade project, which also included technology upgrades to conference rooms
No. 3 and 5, has been completed. This project was done to fix antiquated equipment in the council chamber,
and to bring audio/visual capability to conference rooms 3 and 5.
Discussion: At the September 2, 2020, City Council meeting, Council awarded the contract for the Council
Chambers AV Replacement Project to EIDIM Group, Inc., in the amount of $279,770.43.
Contract work was completed by the contractor in substantial conformance with the approved plans and
specifications and subsequent change orders (Attachment 1) on October 10, 2022. The final contract cost,
based on actual quantities constructed, is $284,211.67. The final payment of the retention will be made to the
contractor after 35 days from the date the Notice of Completion (Attachment 2) is filed with the County
Recorder.
Recommended Action: Approve Notice of Completion for EIDIM Group, Inc. for the Council Chambers AV
Replacement Project, Specification No. 20-09, direct the City Clerk to file the Notice of Completion with the
County Recorder, and approve budget amendment.
BUDGET AMENDMENT REQUIRED: Yes
CURRENT BUDGET AMOUNT: 20824700.80220.15016: $0
PROPOSED BUDGET AMOUNT: 20824700.80220.15016: $9,668.92
FINANCING SOURCE: N/A
PREVIOUS CONTRACT/PURCHASE ORDER NO.: Contract 2021-117
COORDINATED WITH: Mary Horger, Financial Services Manager; Ryan Burkhart, IT Manager
Page 167 of 390
Page 2 of 2
Page 168 of 390
CITY OF UKIAH
MENDOCINO COUNTY, CALIFORNIA
SPECIAL PROVISIONS
FOR
COUNCIL CHAMBERS AV REPLACEMENT
SPECIFICATION NO. 20-09
Non-Mandatory Pre-Bid Meeting via GoToMeeting:
11:00 a.m., Tuesday, August 4th, 2020
Pre-Registration Required
To pre-register, send an email to: mhorger@cityofukiah.com by 5:00 p.m., August 3, 2020
CITY OF UKIAH
300 Seminary Avenue
Ukiah, California 95482-5400
Bids Open: Tuesday, August 18, 2020
2:00 p.m.
Office of City Clerk
ATTACHMENT 1
Page 169 of 390
CITY OF UKIAH
MENDOCINO COUNTY, CALIFORNIA
CITY COUNCIL:
DOUGLAS CRANE– MAYOR
JUAN OROZCO – VICE-MAYOR
JIM BROWN – COUNCIL MEMBER
STEVE SCALMANINI – COUNCIL MEMBER
MAUREEN MULHEREN – COUNCIL MEMBER
SAGE SANGIACOMO – CITY MANAGER
TIM ERIKSEN - DIRECTOR OF PUBLIC WORKS / CITY ENGINEER
MARY HORGER – FINANCIAL SERVICES MANAGER
KRISTINE LAWLER – CITY CLERK
R. ALLEN CARTER - CITY TREASURER
CITY OF UKIAH
July 2020
Page 170 of 390
COUNCIL CHAMBERS AV REPLACEMENT iii Spec No. 20-09
TABLE OF CONTENTS
PAGE
NOTICE TO BIDDERS
INSTRUCTIONS TO BIDDERS .................................................................................................................... 1
GENERAL CONDITIONS
SECTION 1. PROPOSAL REQUIREMENTS AND GENERAL CONDITIONS ............................................ 3
1-01. Definitions
1-02. Examinations of Plans, Special Provisions and Site of Work
1-03. Proposal
1-04. Withdrawal of Bids
1-05. Public Opening of Bids
1-06. Bid Guaranty
1-07. Qualification of Bidders
1-08. Disqualification of Bidders
1-09. Identification of Subcontractors
1-10. General Provisions of the Standard Specifications
1-11. Addenda
SECTION 2. AWARD AND EXECUTION OF CONTRACT ........................................................................ 5
2-01. Award of Contract
2-02. Return of Proposal Guaranties
2-03. Execution of Contract
SECTION 3. SCOPE AND INTENT OF CONTRACT ................................................................................. 5
3-01. Effect of Inspection and Payments
3-02. Effect of Extension of Time
3-03. Extra Work
3-04. Assignment of Contract
3-05. Subcontractors
3-06. Interpretation of Special Provisions and Drawings
3-07. Addenda
3-08. Liability of City Officials
3-09. Dispute Resolution
SECTION 4. BONDS ................................................................................................................................... 6
4-01. Faithful Performance Bond
4-02. Material and Labor Bond
4-03. Defective Material and Workmanship Bond
4-04. Notification of Surety Companies
SECTION 5. INSURANCE REQUIREMENTS FOR CONTRACTORS ....................................................... 7
5-01. Minimum Scope of Insurance
5-02. Minimum Limits of Insurance
5-03. Deductibles and Self-Insured Retentions
5-04. Other Insurance Provisions
5-05. Acceptability of Insurers
5-06. Verification of Coverage
Page 171 of 390
COUNCIL CHAMBERS AV REPLACEMENT iv Spec No. 20-09
5-07. Subcontractors
SECTION 6. RESPONSIBILITIES AND RIGHTS OF CONTRACTOR....................................................... 8
6-01. Legal Address of Contractor
6-02. Office of Contractor at Site
6-03. Attention to Work
6-04. Liability of Contractor
6-05. Protection of Persons and Property
6-06. Protection of City Against Patent Claims
6-07. Protection of Contractor's Work Property
6-08. Regulations and Permits
6-09. Construction Utilities
6-10. Approval of Contractor's Plans
6-11. Suggestions to the Contractor
6-12. Termination of Unsatisfactory Subcontracts
6-13. Preservation of Stakes and Marks
6-14. Assistance to Engineer
6-15. Removal of Condemned Materials and Structures
6-16. Proof of Compliance with Contract
6-17. Errors and Omissions
6-18. Cooperation
6-19. Right of Contractor to Stop Work
6-20. Hiring and Dismissal of Employees
6-21. Wage Rates
6-22. Cleaning Up
6-23. Guaranty
SECTION 7. RESPONSIBILITIES AND RIGHTS OF CITY ...................................................................... 13
7-01. Authority of the Engineer
7-02. Inspection
7-03. Surveys
7-04. Rights-of-Way
7-05. Retention of Imperfect Work
7-06. Changes in the Work
7-07. Additional Drawings by City
7-08. Additional and Emergency Protection
7-09. Suspension of Work
7-10. Right of City to Terminate Contract
7-11. Use of Completed Portions
SECTION 8. WORKMANSHIP, MATERIALS AND EQUIPMENT ............................................................ 15
8-01. General Quality
8-02. Quality in Absence of Detailed Specifications
8-03. Materials and Equipment Specified by Name
8-04. Source of Materials
8-05. Storage of Materials
8-06. Drawings, Samples and Tests
SECTION 9. PROSECUTION OF WORK ................................................................................................. 16
9-01. Equipment and Methods
9-02. Time of Completion
9-03. Avoidable Delays
Page 172 of 390
COUNCIL CHAMBERS AV REPLACEMENT v Spec No. 20-09
9-04. Unavoidable Delays
9-05. Notice of Delays
9-06. Extension of Time
9-07. Unfavorable Weather and Other Conditions
9-08. Saturday, Sunday, Holiday and Night Work
9-09. Hours of Labor
SECTION 10. PAYMENT ........................................................................................................................... 17
10-01. Certification by Engineer
10-02. Progress Estimates and Payment
10-03. Substitution of Securities
10-04. Acceptance
10-05. Final Estimate and Payment
10-06. Delay Payments
10-07. Extra Work and Work Omitted
10-08. Compensation for Extra Work or Work Omitted
10-09. Compensation to the City for Extension of Time
10-10. Liquidated Damages for Delay
SECTION 11. MISCELLANEOUS ............................................................................................................. 20
11-01. Notice
11-02. Computation of Time
11-03 Claims Procedure Required by Public Contract Code Section 9204
11-04. Litigation and Forum Selection
11-05. Waiver
TECHNICAL SPECIFICATIONS
SECTION 12. GENERAL INFORMATION ................................................................................................ 23
12-01. Location and Scope of Work
12-02. Arrangement of Technical Specifications
12-03. Arrangement of Plans
12-04. Business Licenses
12-05. Permits
12-06. Standard Specifications and Standard Plans
12-07. Temporary Facilities
12-08. Public Convenience and Safety
12-09. Maintaining Traffic
12-10. Stream Pollution
12-11. Warranties
12-12. Utilities
12-13. Preconstruction Conference
12-14. Safety Requirements
SECTION 13. CONSTRUCTION DETAILS ............................................................................................... 22
SECTION 14. EXCLUSIONS FROM GENERAL CONDITIONS ............................................................... 22
14-01. Provisions to be Excluded from General Conditions
SECTION 15. AMENDMENTS TO GENERAL CONDITIONS .................................................................. 22
15-01. Provisions of General Conditions to be Amended
Page 173 of 390
COUNCIL CHAMBERS AV REPLACEMENT vi Spec No. 20-09
CERTIFICATES AND DOCUMENTS
BID SUBMITTAL CHECKLIST .................................................................................................................... 26
PROPOSAL ........................................................................................................................................... 27
BIDDING SCHEDULE ................................................................................................................................. 28
FAIR EMPLOYMENT PRACTICES CERTIFICATION ............................................................................... 30
WORKER'S COMPENSATION CERTIFICATE .......................................................................................... 31
CERTIFICATE OF NONDISCRIMINATION IN EMPLOYMENT ................................................................. 32
LIST OF PROPOSED SUBCONTRACTORS ............................................................................................. 33
STATEMENT OF EXPERIENCE OF BIDDER ............................................................................................ 34
SIGNATURE OF BIDDER ........................................................................................................................... 35
BIDDER'S BOND ........................................................................................................................................ 36
NON-COLLUSION AFFIDAVIT ................................................................................................................... 37
AGREEMENT ........................................................................................................................................... 38
INDEMNIFICATION AGREEMENT ............................................................................................................ 42
EXAMPLE BOND FORMS .......................................................................................................................... 43
DIRECTIONS FOR PREPARATION OF PERFORMANCE AND MATERIAL AND LABOR BOND .......... 47
DEFECTIVE MATERIAL AND W ORKMANSHIP (MAINTENANCE) BOND .............................................. 48
INSURANCE CERTIFICATES AND ENDORSEMENT FORMS
APPENDICES:
Appendix A – Master Pricing Table and Supporting Pricing Schedules
Appendix B – Technical Details
Appendix C - Drawings
Page 174 of 390
CITY OF UKIAH, MENDOCINO COUNTY, CALIFORNIA
NOTICE TO BIDDERS FOR COUNCIL CHAMBERS AV REPLACEMENT, SPECIFICATION NO. 20-09
NOTICE IS HEREBY GIVEN that sealed standard proposals for the COUNCIL CHAMBERS AV REPLACEMENT
project will be received at the Office of the City Clerk, Ukiah Civic Center Annex - located at 411 West Clay Street,
Ukiah California until 2:00 p.m. on August 18, 2020, at which time, or as soon thereafter as possible, they will be
publicly opened and read. Bids shall be addressed to the City Clerk and shall be endorsed “COUNCIL CHAMBERS
AV REPLACEMENT." DUE TO THE CITY’S CURRENT CLOSURE TO THE PUBLIC BECAUSE OF THE COVID-
19 EVENT, bids that are HAND DELIVERED must be placed in the Night Drop Box located to the right of the front
doors of the Ukiah Civic Center Annex, at the address listed above. As soon thereafter as possible, the bids will
be publicly opened via live streaming at http://www.cityofukiah.com/meetings/ and read. Bids are required for the
entire work described herein. No fax bids will be accepted.
All of the work to be performed is within the City of Ukiah and consists of the replacement of the audiovisual systems
in the existing office conference rooms and City Council chambers of the Civic Center building. General location of
the work is at the City of Ukiah Civic Center located at 300 Seminary Avenue, Ukiah, California 95482.
A Non-Mandatory Pre-Bid Meeting will take place via GoToMeeting at 11:00 a.m. on August 4th, 2020. Potential
bidders must pre-register for this meeting. To pre-register, please send an email to Mary Horger at
mhorger@cityofukiah.com by 5:00 p.m., August 3rd, 2020. Registrants will receive a reply email to confirm their
registration, along with log-in instructions for the meeting.
Plans and Special Provisions may be inspected and/or copies obtained from the City’s website at
www.cityofukiah.com/purchasing. No bid will be considered unless it is made on the forms furnished by the City
and is made in accordance with the details of the Special Provisions. Each bidder must be licensed as required by
law. Further information regarding the work or these specifications can be obtained by calling Mary Horger,
Financial Services Manager at (707) 463-6233 or by email at mhorger@cityofukiah.com.
The City Council reserves the right to reject any or all bids and to determine which proposal is, in its opinion, the
lowest responsive bid by a responsible bidder and which it deems in the best interest of the City to accept. The City
Council also reserves the right, but not the obligation, to waive any irregularity or failure to strictly comply with the
bidding requirements, that the City determines in the reasonable exercise of its discretion does not provide the
bidder with a competitive advantage over other bidders.
No contractor or subcontractor may be listed on a bid proposal for a public works unless registered with the
Department of Industrial Relations (“DIR”) pursuant to Labor Code section 1725.5 except as allowed. under Labor
Code section 1771.1(a). The prime contractor shall be responsible for posting job site notices as prescribed by
regulation. This project is subject to compliance monitoring and enforcement by the DIR.
Pursuant to provisions of Section 1770, including amendments thereof, of the Labor Cod e of the State of California,
the DIR Director has ascertained the general prevailing rate of wages for straight time, overtime , Saturdays,
Sundays and Holidays including employer payment for health and welfare, vacation, pension and similar purposes
for the City of Ukiah. Copies of his General Prevailing Wage Determination are available on the Internet at web
address: http://www.dir.ca.gov/DLSR/PWD/ The prime contractor for the work herein shall possess a current, valid
State of California, Class C10 Contractor's License. Pursuant to California Public Contract Code §22300, this
contract includes provisions that allow substitutions of certain types of securities in lieu of the City withholding a
portion of the partial payments due the Contractor to insure performance under this contract.
By order of the City Council, City of Ukiah, County of Mendocino, State of California.
Dated:________________________ ________________________________________
Kristine Lawler, City Clerk, City of Ukiah, California
PUBLISH ONE TIME: July 31, 2020
7/17/20
Page 175 of 390
COUNCIL CHAMBER AV REPLACEMENT 1 Spec. No. 20-09
INSTRUCTIONS TO BIDDERS
Council Chamber AV Replacement project shall be performed in accordance with the Plans and Special
Provisions therefor adopted, to which special reference is hereby made.
Each bidder must supply all the information required by the bid documents and Special Provisions.
Minority business enterprises will be afforded full opportunity to submit bids in response to this invitation and will
not be discriminated against on the grounds of race, color or national origin in consideration for an award of any
contract entered into pursuant to this advertisement. Women will be afforded equal opportunity in all areas of
employment. However, the employment of women shall not diminish the standards or requirements for the
employment of minorities.
All proposals or bids shall be accompanied by a cashier's check or certified check payable to the order of the
City of Ukiah amounting to 10 percent of the bid, or by a bond in said amount and signed by the bidder and a
corporate surety, payable to said City. Said check shall be forfeited, or said bond shall become payable to said
City in case the bidder depositing the same does not, within fifteen (15) days after written notice that the contract
has been awarded to him : (a) enter into a contract with the City and (b) furnish certificates of insurance and
endorsements, a bond of faithful performance and a payment bond as described in the Special Provisions.
No bidder shall withdraw his or her bid for a period of thirty (30) calendar days after the date set by the City for
the opening thereof.
The Contractor and any subcontractors shall each possess a valid City of Ukiah Business License prior to the
start of any work.
The Contractor shall furnish a project schedule to the Engineer prior to the start of any work and start work as
scheduled.
The work is to be completed within sixty-three (63) calendar days. The Contractor will pay to the City the sum of
five hundred ($500.00) dollars per day for each and every calendar day's delay beyond the time prescribed.
The staff shall notify a bidder by telephone, email or fax, if it intends to recommend the rejection of the bidder’s
bid. Any bid protest must be filed with the City Clerk not more than five calendar days following the bid
opening, or 2 calendar days following notice that staff is recommending the rejection of a bid. If any such
timely written protest is filed, all bidders shall be provided a copy of the protest within 2 calendar days of its
receipt, which may be delivered to the bidders as an email attachment or by fax. All such bidders may file with
the City Manager a written objection or other response to the protest.
All objections or responses filed not more than 5 days after receipt of the written protest will be presented to the
City Council at its next regular meeting occurring not less than 12 calendar days following the bid opening. The
City Council will resolve the bid protest at that meeting based on the written protest, any staff recommendation
and all timely written objections and responses. In accordance with the Brown Act, any person may address the
City Council on this item during the meeting. The City Council action on the protest shall represent a final decision
by the City on the protest.
Examination of Site, Drawings, Etc.
A Non-Mandatory Pre-Bid Meeting will take place via GoToMeeting at 11:00 a.m. on August 4th, 2020.
Potential bidders must pre-register for this meeting. To pre-register, please send an email to Mary Horger at
mhorger@cityofukiah.com by 5:00 p.m., August 3rd, 2020. Registrants will receive a reply email to confirm their
registration, along with log-in instructions for the meeting. Bidders shall thoroughly examine and be familiar
with the Plans and Special Provisions.
Oral statements or instructions made during this visit will not constitute an amendment to this solicitation. The
City will determine the appropriate action necessary, if any, and may issue a written amendment to the bid
request.
Bidders shall thoroughly examine and be familiar with the Plans and Special Provisions. The failure of any bidder
to receive or examine any form, instrument, addendum, or other document, shall in no way relieve the bidder
Page 176 of 390
COUNCIL CHAMBER AV REPLACEMENT 2 Spec. No. 20-09
from any obligation with respect to his or her proposal or to the contract. The drawings for the work show
conditions as they are supposed or believed by the Engineer to exist; but, it is neither intended nor shall it be
inferred that the conditions as shown thereon constitute a representation by the Engineer, the City or its officers
that such conditions are actually existent, nor shall the City, the Engineer or any of their officers or
representatives be liable for any loss sustained by the Contractor as a result of a variance between the conditions
shown on the drawings and the conditions actually revealed during the progress of the work or otherwise.
The bidder's attention is directed to the possible existence of obstructions and public improvements within the
limits of the work or adjacent thereto, which may or may not be shown on the Drawings. Any bid shall take into
consideration that conditions may exist underground or otherwise that are not known to the City or easily
detected during a site inspection that could impact the time or cost of completing the project. The City expects
the bids to anticipate such conditions so that it can know for budgeting and other purposes the total cost to
complete the project before accepting a bid and undertaking the legal obligation to construct the project. In
awarding the contract the City relies on the contractor’s representation that its bid anticipates differing site
conditions and the additional time or cost that such conditions may necessitate.
The bidder shall investigate to his or her satisfaction the conditions to be encountered, the character, quality and
quantities of work to be performed and materials to be furnished and the requirements of the Plans, Special
Provisions, Standard Specifications, Standard Plans, and Contract Documents. The submission of a proposal
shall be considered conclusive evidence that the bidder has made such examination and has accepted the
project workplace as a safe workplace to perform the work of the Contract.
Bidder Inquiries and Questions
Inquiries and questions must be submitted in writing via fax or email to the following designated contact person:
Mary Horger, Financial Services Manager
Fax: (707) 313-3621
Email: mhorger@cityofukiah.com
The City reserves the right to not respond to inquiries or questions submitted within 3 business days of the bid
opening.
Location of the Work
All of the work to be performed is within the City of Ukiah. Project is located at the Ukiah Civic Center, 300
Seminary Avenue, Ukiah CA 95482.
Page 177 of 390
COUNCIL CHAMBER AV REPLACEMENT 3 Spec. No. 20-09
GENERAL CONDITIONS
SECTION 1. PROPOSAL REQUIREMENTS AND GENERAL CONDITIONS
1-01. Definitions. Whenever any word or expression defined in this section, or pronoun used in its stead,
occurs in these contract documents, it shall have and is mutually understood to have the meaning given:
a. "City of Ukiah" or "City" shall mean the City of Ukiah, Mendocino County, California, acting
through its City Council or any other board, body, official or officials to which or to whom the
power belonging to the Council shall by virtue of any act or acts, hereafter pass or be held to
appertain.
b. "Engineer" shall mean the Engineer duly and officially appointed by the City to supervise and
direct the work of construction under this contract, acting personally or through agents or
assistants duly authorized by him, such agents or assistants acting within the scope of the
particular duties entrusted to them.
c. "Inspector" shall mean the engineering or technical inspector or inspectors duly authorized or
appointed by the Engineer, limited to the particular duties entrusted to him or her or them.
d. "Contractor" shall mean the party entering into contract with the City of Ukiah for the
performance of work covered by this contract and his or her authorized agents or legal
representatives.
e. "Date of signing of contract" or words equivalent thereto, shall mean the date upon which this
contract, with the signature of the Contractor affixed, together with the prescribed bonds, shall
be or shall have been delivered to the City or its duly authorized representatives.
f. "Day" or "days", unless herein otherwise expressly defined, shall mean a calendar day or days
of twenty-four hours each.
g. "The work" shall mean and include all the work specified, indicated, shown or contemplated in
the contract to construct the improvement, including all alterations, amendments or extensions
thereto made by contract change order or other written orders of the Engineer.
h. "Contract drawings", "drawings", "plans" shall mean and include 1) all drawings or plans which
may have been prepared by or on behalf of the City, as a basis for proposals, when duly signed
and made a part of this contract by incorporation or reference, 2) all drawings submitted in
pursuance of the terms of this contract by the successful bidder with his or her proposal and by
the Contractor to the City if and when approved by the Engineer and 3) all drawings submitted
by the Engineer to the Contractor during the progress of the work as provided for herein.
i. Where "as shown", "as indicated", "as detailed" or words of similar import are used, it shall be
understood that reference to the drawings accompanying these Special Provisions is made
unless stated otherwise.
Where "as directed", "as permitted", "approved" or words of similar import are used, it shall be
understood that the direction, requirements, permission, approval or acceptance of the Engineer
is intended unless stated otherwise.
As used herein, "provide" or "install" shall be understood to mean "provide or install complete
in place", that is, "furnish and install". "Shall" is mandatory; "may" is permissive.
1-02. Examination of Plans, Special Provisions and Site of Work. The bidder shall examine carefully the
Proposal, Plans, Special Provisions, Contract forms and the site of the work contemplated therefor. It will be
assumed that the bidder has investigated to his or her satisfaction the conditions to be encountered and the
character, quality and requirements of all Plans, Special Provisions, Standard Specifications, and Standard
Plans involved.
Page 178 of 390
COUNCIL CHAMBER AV REPLACEMENT 4 Spec. No. 20-09
1-03. Proposal. Bids shall be made on the blank forms prepared by the City. All bids shall give the prices bid,
both in writing and in figures and shall be signed by the bidder or his or her authorized representative, with his
or her address. If the bid is made by an individual or partner, his or her name and the post office address of his
or her business or partnership, along with his or her signature or the signature of one or more partners must be
shown; if made by a corporation, the bid shall show the name of the state under the laws of which the corporation
is chartered, the name of the corporation and the title of the person who signs on behalf of the corporation.
Each proposal shall be enclosed in a sealed envelope, endorsed as specified in the notice to bidders. Bidders
are warned against making erasures or alterations of any kind and proposals which contain omissions, erasures,
conditions, alterations, additions not called for, additional proposals or irregularities of any kind may be rejected.
1-04. Withdrawal of Bids. Any bid may be withdrawn at any time prior to the hour fixed in the notice to bidders
for the openings of bids, provided that a request in writing, executed by the bidder or his or her duly authorized
representative, for the withdrawal of such bid is filed with the City. The withdrawal of a bid will not prejudice the
right of a bidder to file a new bid.
1-05. Public Opening of Bids. Bids will be opened and read publicly at the time and place indicated in the
notice to bidders. Bidders or their agents are invited to be present.
1-06. Bid Guaranty. Each bid must be accompanied by a certified check, cashier's check or bidder's bond
executed by an admitted surety insurer, payable to the order of the City of Ukiah in an amount not less than 10
percent of the bid as a guarantee that the bidder will enter into a contract, if awarded the work.
1-07. Qualification of Bidders. No contractor or subcontractor may be listed on a bid proposal for a public
works project (submitted on or after March 1, 2015) unless registered with the Department of Industrial Relations
pursuant to Labor Code section 1725.5 [with limited exceptions from this requirement for bid purposes only
under Labor Code section 1771.1(a)]. No contractor or subcontractor may be awarded a contract for public work
on a public works project (awarded on or after April 1, 2015) unless registered with the Department of Industrial
Relations pursuant to Labor Code section 1725.5. The prime contractor shall be responsible for posting job site
notices as prescribed by regulation. This project is subject to compliance monitoring and enforcement by the
Department of Industrial Relations.
Each bidder shall be licensed under the provisions of Chapter 9, Division 3 of the Business and Professions
Code and shall be skilled and regularly engaged in the general class or type of work called for under this contract.
A statement setting forth this experience and business standing shall be submitted by each bidder on the form
provided herewith. It is the intention of the City to award a contract only to a bidder who furnishes satisfactory
evidence that he or she has the requisite experience and ability and that he or she has sufficient capital, facilities
and equipment to enable him or her to prosecute the work successfully and promptly within the time and in the
manner agreed.
In determining the degree of responsibility to be credited to a bidder, the City may weigh evidence that the bidder
or his or her personnel charged with the responsibility in the work, has performed satisfactorily other contracts
of like nature and magnitude or comparable difficulty at similar rates of progress.
1-08. Disqualification of Bidders. More than one bid from an individual business, partnership, corporation or
association, under the same or different names, will not be considered. Reasonable grounds for believing that
any bidder is financially interested in more than one bid for the work will cause the rejection of all bids in which
he or she is so interested. If there is reason to believe that collusion exists among the bidders, none of the
participants in such collusion will be considered. Bids in which the prices obviously are unbalanced may be
rejected.
1-09. Identification of Subcontractors. All bids shall comply with the Subletting and Subcontracting Fair
Practices Act (Public Contract Code Section 4100 and following) and shall set forth:
(a) The name and the location of the place of business of each subcontractor who will perform work or
labor, or render service to the prime contractor in or about the construction of the work, or to a
subcontractor licensed by the State of California who, under subcontract to the prime contractor,
specially fabricates and installs a portion of the work according to detailed drawings contained in the
plans and Special Provisions, in an amount in excess of one-half of 1 percent of the prime contractor's
total bid.
Page 179 of 390
COUNCIL CHAMBER AV REPLACEMENT 5 Spec. No. 20-09
(b) The portion of the work which will be done by each such subcontractor. The prime contractor shall
list only one subcontractor for each such portion defined by the prime contractor in his or her bid.
1-10. General Provisions of the Standard Specifications. All provisions of the General Provisions, Sections
1 through 11, of the Standard Specifications, shall be applicable to the contract except as modified by these
Special Provisions. The Standard Specifications are set forth in Section 12-06 of these Special Provisions.
1-11. Addenda. If it becomes necessary to revise any part of these plans and specifications after they have
been released, the City will issue an addendum containing the revision. All addenda will be posted on the City’s
website at www.cityofukiah.com/purchasing with the rest of the bid documents. Anyone who intends to submit
a bid in response to this Request for Bid must check the website frequently for any posted addenda. Anyone
submitting a bid will be deemed to have seen and agreed to be bound by the posted addenda.
SECTION 2. AWARD AND EXECUTION OF CONTRACT
2-01. Award of Contract. Award of the contract, if it be awarded, will be to the lowest responsible bidder whose
bid complies with all the specified requirements. The award, if made, will be made within thirty (30) days after
opening of the bids. The City reserves the right to reject any and all bids and to waive any irregularity in the
proposal not pertaining to cost.
2-02. Return of Proposal Guaranties. All bid guaranties will be held until the contract has been fully executed,
after which they will be returned upon request to the respective bidders whose bids they accompany.
2-03. Execution of Contract. The contract agreement shall be executed in duplicate by the successful bidder
and returned, together with the contract bonds, insurance certificates and endorsements, within fifteen (15) days
after written notice of the award of the contract. After execution by the City; one copy shall be filed with the City
and one copy shall be returned to the Contractor. If the bidder fails or refuses to enter into the contract agreement
within the required time, then the bid guaranty accompanying the bid shall be forfeited to the City.
SECTION 3. SCOPE AND INTENT OF CONTRACT
3-01. Effect of Inspection and Payments. Neither the inspection by the Engineer or an inspector, nor any
order, measurement or approved modification, nor certificate or payment of money, nor acceptance of any part
or whole of the work, nor any extension of time, nor any possession by the City or its agents, shall operate as a
waiver of any provision of this contract or of any power reserved therein to the City, or of any right to damages
thereunder; nor shall any breach of this contract be held to be a waiver of any subsequent breach. All remedies
shall be construed as cumulative.
3-02. Effect of Extension of Time. The granting of any extension of time on account of delays which, in the
judgement of the City, are avoidable delays shall in no way operate as a waiver on the part of the City of its
rights under this contract.
3-03. Extra Work. If extra work orders are given in accordance with provisions of this contract, such work shall
be considered a part hereof and shall be subject to each and all of its terms and requirements.
3-04. Assignment of Contract. The contract may be assigned or sublet in whole or in part only upon the
written consent of the City acting through its authorized agents. Consent will not be given to any proposed
assignment which would relieve the original contractor or its surety of their responsibilities under the contract
nor will the Engineer consent to any assignment of a part of the work under the contract.
3-05. Subcontractors. The Contractor shall be as fully responsible for the acts and omissions of his or her
subcontractors and of persons either directly or indirectly employed by them, as he or she is for the acts and
omissions of persons directly employed by him.
The Contractor shall cause appropriate provisions to be inserted in all subcontracts relative to the work to bind
subcontractors to the terms of this Contract which are applicable to the work of subcontractors.
Page 180 of 390
COUNCIL CHAMBER AV REPLACEMENT 6 Spec. No. 20-09
Nothing contained in this contract shall be construed to create or shall be relied upon to create any contractual
relationship between any subcontractor and the City and no action may be brought by any subcontractor against
the City based on this contract.
3-06. Interpretation of Special Provisions and Drawings. The Special Provisions and the Contract Drawings
are intended to be explanatory of each other. Any work indicated in the Contract Drawings and not in the Special
Provisions, or vice versa, is to be executed as if indicated in both. In case of a discrepancy or conflict between
the Technical Specifications and Contract Plans, the Technical Specifications shall govern. All work shown on
the Contract Drawings, the dimensions of which are not figured, shall be accurately followed to the scale to
which the drawings are made, but figured dimensions are in all cases to be followed, where given, though they
differ from scaled measurements. Large scale drawings shall be followed in preference to small scale drawings.
Should it appear that the work to be done, or any of the matters relative thereto, are not sufficiently detailed or
explained in these contract documents, including the contract drawings, the Contractor shall apply to the
Engineer for such further explanations as may be necessary and shall conform thereto as part of this contract,
so far as may be consistent with the terms of this contract. In the event of any doubt or questions arising
respecting the true meaning of the Special Provisions, reference shall be made to the Engineer and his or her
decision thereon shall be final. If the Contractor believes that a clarification or interpretation justifies an increase
in the contract price or contract time, the Contractor must comply with the written notice provisions of Sections
9-05 and 10-07 of these Special Provisions. Contractor’s attention is directed to Section 12-06 of the Technical
Specifications regarding the Standard Specifications and Standard Plans.
3-07. Addenda. If it becomes necessary to revise any part of these plans and specifications after they have
been released, the City will issue an addendum containing the revision. All addenda will be posted on the City’s
website at www.cityofukiah.com/purchasing with the rest of the bid documents. Anyone who intends to submit
a bid in response to this Request for Bid must check the website frequently for any posted addenda. Anyone
submitting a bid will be deemed to have seen and agreed to be bound by the posted addenda.
3-08. Liability of City Officials. No city official, nor the Engineer, nor any authorized assistant of any of them,
shall be personally responsible for any liability arising under this contract.
3-09. Dispute Resolution. Claims of $375,000 or less by the Contractor that arise under this Contract are
subject to the mandatory dispute resolutions provisions in Public Contract Code Sections 20104-20104.6.
SECTION 4. BONDS
4-01. Faithful Performance Bond. As a part of the execution of this contract, the Contractor shall furnish a
bond of a surety company or other securities providing equivalent protection such as cash, letter of credit, or
certificates of deposit, acceptable to the City, conditioned upon the faithful performance of all covenants and
stipulations under this contract. The amount of the bond shall be 100 percent of the total contract price, as this
sum is set forth in the agreement.
4-02. Material and Labor Bond. As a part of the execution of this contract, the Contractor shall furnish a bond
of a surety company or other securities providing equivalent protection such as cash, letter of credit or certificates
of deposit acceptable to the City in a sum not less than 50 percent of the total contract price, as this sum is set
forth in the agreement for the payment in full of all persons, companies or corporations who perform labor upon
or furnish materials to be used in the work under this contract, in accordance with the provisions of Sections
3247 through 3252 inclusive of the Civil Code of the State of California and any acts amendatory thereof.
4-03. Defective Material and Workmanship Bond. As a condition precedent to the completion of this contract,
the Contractor shall furnish a bond of a surety company acceptable to the City in an amount not less than 5
percent (5%) of the final contract price, to hold good for a period of one (1) year after the completion and
acceptance of the work, to protect the City against the results of defective materials, workmanship and
equipment during that time. This bond shall be delivered to the City before the final payment under this contract
will be made.
4-04. Notification of Surety Companies. The surety companies shall familiarize themselves with all of the
conditions and provisions of this contract and they waive the right of special notification of any change or
modification of this contract or of extension of time, or decreased or increased work, or of the cancellation of the
Page 181 of 390
COUNCIL CHAMBER AV REPLACEMENT 7 Spec. No. 20-09
contract, or of any other act or acts by the City or its authorized agents, under the terms of this contract; and
failure to so notify the aforesaid surety companies of changes shall in no way relieve the surety companies of
their obligation under this contract.
SECTION 5. INSURANCE REQUIREMENTS FOR CONTRACTORS
(WITH CONSTRUCTION RISKS)
Contractor shall procure and maintain for the duration of the contract insurance against claims for injuries to
persons or damages to property which may arise from or in connection with the performance of the work
hereunder by the Contractor, his or her agents, representatives, employees or subcontractors.
5-01. Minimum Scope of Insurance
Coverage shall be at least as broad as:
1. Insurance Services Office Commercial Liability Coverage (occurrence form CG 0001).
2. Insurance Services Office form number CA 0001 (Ed. 1/87) covering Automobile Liability, code 1 (any
auto).
3. Worker's Compensation insurance as required by the State of California and Employer's Liability
Insurance.
4. Course of Construction insurance covering for “all risks” of loss.
5-02. Minimum Limits of Insurance
Contractor shall maintain limits no less than:
1. General Liability: $1,000,000 per occurrence for bodily injury, personal injury and property
damage including operations, products and completed operations. If
Commercial General Liability Insurance or other form with a general aggregate
limit is used, either the general aggregate limit shall apply separately to this
project/location or the general aggregate limit shall be twice the required
occurrence limit.
2. Automobile Liability: $1,000,000 per accident for bodily injury and property damage.
3. Employer's Liability: $1,000,000 per accident for bodily injury and property damage.
4. Course of Construction: Completed value of the project with no co-insurance penalty provisions.
5-03. Deductibles and Self-insured Retentions. Any deductibles or self-insured retentions must be declared
to and approved by the City. At the option of the City, either: the insurer shall reduce or eliminate such
deductibles or self-insured retentions as respects the City, its officers, officials, employees and volunteers; or
the Contractor shall provide a financial guarantee satisfactory to the City guaranteeing payment of losses and
related investigations, claim administration and defense expenses.
5-04. Other Insurance Provisions
The general liability and automobile liability policies are to contain, or be endorsed to contain, the following
provisions:
1. The City, its officers, officials, employees and volunteers are to be covered as Additional Insured with
respect to liability arising out of automobiles owned, leased, hired or borrowed by or on behalf of the
contractor; and with respect to liability arising out of work or operations performed by or on behalf of the
Contractor including materials, parts or equipment furnished in connection with such work or operations.
General liability coverage can be provided in the form of an endorsement to the Contractor's insurance,
or as a separate owner's policy.
Page 182 of 390
COUNCIL CHAMBER AV REPLACEMENT 8 Spec. No. 20-09
2. The workers’ compensation policy is to be endorsed with a waiver of subrogation. The insurance
company, in its endorsement, agrees to waive all rights of subrogation against the City, its officers,
officials, employees and volunteers for losses paid under the terms of this policy which arises from the
work performed by the named insured for the City.
3. For any claims related to this project, the Contractor's insurance coverage shall be primary insurance
as respects the City, its officers, officials, employees or volunteers. Any insurance or self-insurance
maintained by the City, its officers, officials, employees or volunteers shall be excess of the Contractor's
insurance and shall not contribute with it.
4. Each insurance policy required by this clause shall be endorsed to state that coverage shall not be
canceled by either party, except after thirty (30) days' prior written notice by certified mail, return receipt
requested, has been given to the City.
5. Coverage shall not extend to any indemnity coverage for the active negligence of the additional insured
in any case where an agreement to indemnify the additional insured would be invalid under Subdivision
(b) of Section 2782 of Civil Code.
6. Course of Construction policies shall contain the following provisions:
a.) The City shall be named as loss payee.
b.) The insurer shall waive all rights of subrogation against the City.
5-05. Acceptability of Insurers
Insurance is to be placed with insurers with a current A.M. Best's rating of no less than the following:
A++ VII A- VIII
A+ VII B++ X
A VII B+ X
5-06. Verification of Coverage. Contractor shall furnish the City with original certificates and amendatory
endorsements effecting coverage required by this clause. The endorsements shall be on forms provided by the
City or on other than the City's forms, provided those endorsements or policies conform to the requirements. All
certificates and endorsements are to be received within 15 days from written notice of contract award, and the
work shall not commence until the certificates and endorsements have been approved by the City. The City
reserves the right to require complete certified copies of all required insurance policies, including endorsements
affecting the coverage required by these Special Provisions at any time.
5-07. Subcontractors. Contractor shall include all subcontractors as insureds under its policies or shall furnish
separate certificates and endorsements for each subcontractor. All coverages for subcontractors shall be subject
to all of the requirements stated herein.
SECTION 6. RESPONSIBILITIES AND RIGHTS OF CONTRACTOR
6-01. Legal Address of Contractor. Both the address given in the proposal and the Contractor's office in the
vicinity of the work are hereby designated as places to either of which drawings, samples, notices, letters or
other articles or communications to the Contractor may be mailed or delivered. The delivery at either of these
places of any such thing from the City or its agents to the Contractor shall be deemed sufficient service thereof
upon the Contractor and the date of such service shall be the date of such delivery. The address nam ed in the
proposal may be changed at any time by notice in writing from the Contractor to the City. Nothing herein
contained shall be deemed to preclude or render inoperative the service of any drawing, sample, notice, letter
or other article or communication to or upon the Contractor personally.
6-02. Office of Contractor at Site. During the performance of this contract, the Contractor shall maintain a
suitable office at the site of the work which shall be the headquarters of a representative authorized to receive
drawings and any such thing given to the said representatives or delivered at the Contractor's office at the site
of work in his or her absence shall be deemed to have been given to the Contractor.
Page 183 of 390
COUNCIL CHAMBER AV REPLACEMENT 9 Spec. No. 20-09
6-03. Attention to Work. The Contractor shall give his or her personal attention to and shall supervise the
work to the end that it shall be prosecuted faithfully and when he or she is not personally present on the work,
he or she shall at all reasonable times be represented by a competent superintendent or foreman who shall
receive and obey all instructions or orders given under this contract and who shall have full authority to execute
the same and to supply materials, tools and labor without delay and who shall be the legal representative of the
Contractor. The Contractor shall be liable for the faithful observance of any instructions delivered to him or her
or to his or her authorized representative.
6-04. Liability of Contractor. The Contractor shall do all of the work and furnish all labor, materials, tools and
appliances, except as otherwise herein expressly stipulated, necessary or proper for performing and completing
the work herein required in the manner and within the time herein specified. The mention of any specific duty or
liability imposed upon the Contractor shall not be construed as a limitation or restriction of any general liability
or duty imposed upon the Contractor by this contract, said reference to any specific duty or liability being made
herein merely for the purpose of explanation.
The right of general supervision by the City shall not make the Contractor an agent of the City and the liability of
the Contractor for all damages to persons or to public or private property, arising from the Contractor's execution
of the work, shall not be lessened because of such general supervision.
Until the completion and final acceptance by the City of all the work under and implied by this contract, the work
shall be under the Contractor's responsible care and charge. The Contractor shall rebuild, repair, restore and
make good all injuries, damages, re-erections and repairs, occasioned or rendered necessary by causes of any
nature whatsoever, excepting only acts of God and none other, to all or any portions of the work, except as
otherwise stipulated.
To the fullest extent permitted by law, Contractor shall indemnify and hold harmless the City and its officers,
directors, agents and employees from and against all claims, damages, losses and expenses including but not
limited to attorneys' fees, costs of suit, expert witness fees and expenses and fees and costs of any necessary
private investigators arising out of or resulting from the performance of the work, provided that any such claim,
damage, loss or expense (1) is attributable to bodily injury, sickness, disease or death, or to injury to or
destruction of tangible property, other than the work itself, including the loss of use resulting therefrom and (2)
is caused in whole or in part by any act or omission of the Contractor, any subcontractor, or anyone directly or
indirectly employed by any of them, or anyone for whose acts any of them may be liable, regardless of whether
or not it is caused in part by a party indemnified hereunder, or by the negligence or omission of a party
indemnified herein.
In any and all claims against the City or any of its agents or employees by any employee of the Contractor, any
subcontractor, anyone directly or indirectly employed by any of them, or anyone for whose acts any of them may
be liable, the indemnification obligation shall not be limited in any way by any limitation on the amount or type of
damages, compensation or benefits payable by or for the Contractor or any subcontractor under workers' or
workmen's compensation acts, disability benefit acts, or other employee benefit acts. The obligation to indemnify
shall extend to and include acts of the indemnified party which may be negligent or omissions which may cause
negligence.
The City shall have the right to estimate the amount of such damage and to cause the City to pay the same and
the amount so paid for such damage shall be deducted from the money due the Contractor under this contract;
or the whole or so much of the money due or to become due the Contractor under this contract as may be
considered necessary by the City, shall be retained by the City until such suits or claims for damages shall have
been settled or otherwise disposed of and satisfactory evidence to that effect furnished to the City.
6-05. Protection of Persons and Property. The Contractor shall furnish such watchman, guards, fences,
warning signs, walks and lights as shall be necessary and shall take all other necessary precautions to prevent
damage or injury to persons or property.
All property line fences and improvements in the vicinity of the work shall be protected by the Contractor and, if
they are injured or destroyed, they and any other property injured by the Contractor, his or her employees or
agents, shall be restored to a condition as good as when he or she entered upon the work.
Page 184 of 390
COUNCIL CHAMBER AV REPLACEMENT 10 Spec. No. 20-09
6-06. Protection of City Against Patent Claims. All fees, royalties or claims for any patented invention, article
or method that may be used upon or in any manner connected with the work under this contract shall be included
in the price bid for the work and the Contractor and his or her sureties shall protect and hold the City, together
with all of its officers, agents, servants and employees, harmless against any and all demands made for such
fees or claims brought or made on account of this contract. The Contractor shall, if requested by the Engineer,
furnish acceptable proof of a proper release from all such fees or classes.
Should the Contractor, his or her agents, servants or employees, or any of them be enjoined from furnishing or
using any invention, article, material or appliance supplied or required to be supplied or used under this contract,
the Contractor shall promptly substitute other articles, materials or appliance, in lieu thereof, of equal efficiency,
quality, finish, suitability and market value and satisfactory in all respects to the Engineer. Or, in the event that
the Engineer elects, in lieu of such substitution, to have supplied and to retain and use, any such invention,
article, material or appliance, as may by this contract be required to be supplied, in that event the Contractor
shall pay such royalties and secure such valid licenses as may be requisite and necessary for the City, its
officers, agents, servants and employees, or any of them, to use such invention, article, material or appliance
without being disturbed or in any way interfered with by any proceeding in law or equity on account thereof.
Should the Contractor neglect or refuse to make the substitution promptly, or to pay such royalties and secure
such licenses as may be necessary, then in that event the Engineer shall have the right to make such
substitution, or the City may pay such royalties and secure such licenses and charge the cost thereof against
any money due to the Contractor from the City or recover the amount thereof from him or her and his or her
sureties notwithstanding final payment under this contract may have been made.
6-07. Protection of Contractor's Work Property. The Contractor shall protect his or her work, supplies and
materials from damage due to the nature of the work, the action of the elements, trespassers, or any cause
whatsoever under his or her control, until the completion and acceptance of the work. Neither the City nor any
of its agents assumes any responsibility for collecting indemnity from any person or persons causing damage to
the work of the Contractor.
6-08. Regulations and Permits. The Contractor shall secure and pay for all permits, give all notices and
comply with all laws, ordinances, rules and regulations bearing on the conduct of the work as drawn and
specified. If the Contractor observes that the Plans and Special Provisions are at variance therewith, he or she
shall promptly notify the Engineer in writing and any necessary changes shall be adjusted as provided in the
contract for changes in the work. The contractor and any subcontractors shall each secure and maintain a valid
City of Ukiah Business License. The City of Ukiah will issue a no fee encroachment permit to the Contractor
allowing him or her to perform work within City right of way or within City property after the Contract Documents
have been executed and insurance certificates and endorsements have been approved by the City.
6-09. Construction Utilities. The Contractor shall be responsible for providing for and in behalf of his or her
work under this contract, all necessary utilities, such as special connection to water supply, telephones, power
lines, fences, roads, watchmen, suitable storage places, etc.
6-10. Approval of Contractor's Plans. The approval by the Engineer of any drawing or any method of work
proposed by the Contractor in accordance with paragraph 8-06 shall not relieve the Contractor of any of his or
her responsibility for his or her errors therein and shall not be regarded as any assumption of risk or liability by
the City or any officer or employee thereof and the Contractor shall have no claim under this contract on account
of the failure or partial failure or inefficiency of any plan or method so approved. Such approval shall be
considered to mean merely that the Engineer has no objection to the Contractor's using, upon his or her own full
responsibility the plan or method approved.
6-11. Suggestions to the Contractor. Any plan or method of work suggested by the Engineer to the
Contractor, but not specified or required, if adopted or followed by the Contractor in whole or in part, shall be
used at the risk and responsibility of the Contractor; and the Engineer and the City shall assume no responsibility
thereof.
6-12. Termination of Unsatisfactory Subcontracts. Should any subcontractor fail to perform in a satisfactory
manner the work undertaken by him, such subcontract shall be terminated immediately by the Contractor upon
notice from the Engineer.
Page 185 of 390
COUNCIL CHAMBER AV REPLACEMENT 11 Spec. No. 20-09
6-13. Preservation of Stakes and Marks. The Contractor shall preserve carefully bench marks, reference
points and stakes and in case of destruction he or she shall replace his or her stakes, reference points and
bench marks and shall be responsible for any mistakes that may be caused by their unnecessary loss or
disturbance. Contractor’s attention is directed to Section 7-03 of these Special Provisions.
6-14. Assistance to Engineer. At the request of the Engineer the Contractor shall provide men from his or her
force and tools, stakes and other materials to assist the Engineer temporarily in making measurements and
surveys and in establishing temporary or permanent reference marks. Payment for such materials and
assistance will be made as provided for under the caption "Extra Work," provided, however, that the cost of
setting stakes and marks carelessly lost or destroyed by the Contractor's employees will be assessed to the
Contractor.
6-15. Removal of Condemned Materials and Structures. The Contractor shall remove from the site of the
work, without delay, all rejected and condemned materials or structures of any kind brought to or incorporated
in the work and upon his or her failure to do so, or to make satisfactory progress in so doing, within forty-eight
(48) hours after the service of a written notice from the Engineer, the condemned material or work may be
removed by the City and the cost of such removal shall be taken out of the money that may be due or may
become due the Contractor on account of or by virtue of this contract. No such rejected or condemned material
shall again be offered for use by the Contractor under this Contract.
6-16. Proof of Compliance with Contract. In order that the Engineer may determine whether the Contractor
has complied with the requirements of this contract, not readily enforceable through inspection and tests of the
work and materials, the Contractor shall, at any time when requested, submit to the Engineer properly
authenticated documents or other satisfactory proofs as to his or her compliance with such requirements.
6-17. Errors and Omissions. If the Contractor, in the course of the work, finds any errors or omissions in plans
or in the layout as given by survey points and instruction, or if he or she finds any discrepancy between the plans
and the physical conditions of the locality, he or she shall immediately inform the Engineer, in writing and the
Engineer shall promptly verify the same. Any work done after such discovery, until authorized, will be done at
the Contractor's risk.
6-18. Cooperation. The Contractor shall cooperate with all other contractors who may be performing work in
behalf of the City and workmen who may be employed by the City on any work in the vicinity of the work to be
done under this contract with the work of such contractors or workmen. he or she shall make good promptly, at
his or her own expense, any injury or damage that may be sustained by other contractors or employees of the
City at his or her hands.
Any difference or conflict which may arise between the Contractor and other contractors, or between the
contractor and workmen of the City in regard to their work shall be adjusted and determined by the Engineer. If
the work of the Contractor is delayed because of any acts or omissions of any other contractor or of the City, the
Contractor shall on that account have no claim against the City other than for an extension of time.
6-19. Right of Contractor to Stop Work. Under the following conditions the Contractor shall have the right, if
he or she so desires, to stop the work and terminate the contract upon ten (10) days written notice to the Engineer
and recover from the City payment for all work actually performed and for all satisfactory materials actually
delivered to the site of the work for permanent incorporation therein, all as may be shown by the estimate of the
Engineer.
(1) If the work is stopped under an order of any court or other competent public authority for a period
of time of three (3) months through no act or fault of the Contractor or of anyone employed by
him.
(2) If the Engineer fails to issue the monthly certificate for payment in accordance with the terms of
this contract.
(3) If the City fails to pay the Contractor within sixty (60) days after it shall have become due, as
provided by the terms of this contract, any sum certified by the Engineer or awarded by the City.
Page 186 of 390
COUNCIL CHAMBER AV REPLACEMENT 12 Spec. No. 20-09
All provided that if such action to terminate the contract be not instituted by the Contractor within ten (10) days
after the alleged existence of such condition and if written notice of such action be not at that time delivered to
the City and the Engineer, then such right shall lapse until another occasion arises according to this section.
6-20. Hiring and Dismissal of Employees. The Contractor shall employ only such foremen, mechanics and
laborers as are competent and skilled in their respective lines of work and whenever the Engineer shall notify
the Contractor that any person on the work is, in his or her opinion, incompetent, unfaithful, intemperate or
disorderly, or refuses to carry out the provisions of this contract, or uses threatening or abusive language to any
person on the work representing the City, or is otherwise unsatisfactory, such person shall be discharged
immediately from the work and shall not be re-employed upon it except with the consent of the Engineer.
6-21. Wage Rates.
1. Contractor shall pay all mechanics and laborers employed or working upon the site of the work
unconditionally and without subsequent deductions or rebate on any account the full amounts due at
the time of payment at wage rates not less than those contained in the applicable prevailing wage
determination, regardless of any contractual relationship which may be alleged to exist between the
Contractor and subcontractors and such laborers and mechanics.
2. Contractor shall comply with the California Labor Code Section 1775. In accordance with said Section
1775, Contractor shall forfeit as a penalty to the Owner, $50.00 (or the higher minimum penalty as
provided in Section 1775(B)(ii) – (iii)) for each calendar day or portion thereof, for each workman paid
less than the stipulated prevailing rates for such work or craft in which such workman is employed for
any work done under the Contract by him or her or by any subcontractor under him or her in violation of
the provisions of the Labor Code and in particular, Labor Code Sections 1770 to 1780, inclusive. In
addition to said penalty and pursuant to Section 1775, the difference between such stipulated prevailing
wage rates and the amount paid to each workman for each calendar day or portion thereof for which
each workman was paid less than the stipulated prevailing wage rate shall be paid to each workman by
the Contractor.
3. Pursuant to the provision of Section 1770 of the Labor Code of the State of California, Owner has
ascertained the general prevailing rate of wages (which rate includes employer payments for health and
welfare, vacation, pension and similar purposes) applicable to the work to be done, for straight time
work. The holiday wage rate listed shall be applicable to all holidays recognized in the collective
bargaining agreement of the particular craft, classification or type of workmen concerned. Copies of the
General Prevailing Wage Determination are available on the Internet at web address:
http://www.dir.ca.gov/DLSR/PWD The Contractor shall post the wage determination at the site of work
in a prominent place where it can easily be seen by the workers.
4. City will not recognize any claim for additional compensation because the Contractor has paid any rate
in excess of the prevailing wage rate obtained by the Contractor. The possibility of wage increases is
one of the elements to be considered by the Contractor in determining his or her bid and will not in any
circumstances be considered as the basis for a claim against the City.
5. The Labor Commissioner through the Division of Labor Standards Enforcement (DLSE) may at any time
require contractors and subcontractors to furnish electronic certified payroll records directly to DLSE.
Commencing with contracts awarded or after April 1, 2015, all contractors and subcontractors must
furnish electronic certified payroll records directly to the DLSE.
6. Travel and Subsistence Payments.
Contractor shall make travel and subsistence payments to each workman needed to execute
the work in accordance with the requirements in Section 1773.8 of the Labor Code (Chapter
880, Statutes of 1968).
7. Apprentices.
Page 187 of 390
COUNCIL CHAMBER AV REPLACEMENT 13 Spec. No. 20-09
Attention is directed to the provisions in Sections 1777.5 (Chapter 1411, Statutes of 1968) and
1777.6 of the California Labor Code concerning the employment of apprentices by the
Contractor or any subcontractor under him. Contractor and any subcontractor under him or her
shall comply with the requirements of said sections in the employment of apprentices.
Information relative to apprenticeship standards, wage schedules and other requirements may
be obtained from the Director of Industrial Relations, ex officio the Administrator of
Apprenticeship, San Francisco, California, or from the Division of Apprenticeship Standards and
its branch offices.
6-22. Cleaning Up. The Contractor shall not allow the site of the work to become littered with trash and waste
material, but shall maintain the same in a neat and orderly condition throughout the construction period. The
Engineer shall have the right to determine what is or is not waste material or rubbish and the place and manner
of disposal.
On or before the completion of the work, the Contractor shall without charge therefore carefully clean out all pits,
pipes, chambers or conduits and shall tear down and remove all temporary structures built by him or her and
shall remove rubbish of all kind from any of the grounds which he or she has occupied and leave them in first
class condition.
6-23. Guaranty. All work shall be guarantied for a period of one year from the date of acceptance by the City.
The Contractor shall promptly make all needed repairs arising out of defective materials, workmanship and
equipment.
The City is hereby authorized to make such repairs if within ten days after the mailing of a notice in writing to the
Contractor or his or her agent, the Contractor shall neglect to make or undertake with due diligence the aforesaid
repairs, provided, however, that in case of an emergency where, in the opinion of the City delay would cause
serious loss or damage, repairs may be made without notice being sent to the Contractor and the Contractor
shall pay the costs thereof.
Pursuant to the provisions of Section 4-03 of these Special Provisions, the Contractor shall furnish a Defective
Material and Workmanship Bond in an amount not less than 5 percent of the final contract price, which shall be
effective for a period of one (1) year after the completion and acceptance of the work.
SECTION 7. RESPONSIBILITIES AND RIGHTS OF CITY
7-01. Authority of the Engineer. All work done under this contract shall be done in a workmanlike manner
and shall be performed to the reasonable satisfaction of the Engineer, who shall have general supervision of all
work included hereunder. To prevent disputes and litigation, the Engineer (1) shall in all cases determine the
amount, quality, acceptability and fitness of the several kinds of work and materials which are to be paid for
under this contract, (2) shall decide all questions relative to the true construction, meaning and intent of the
Special Provisions and Drawings, (3) shall decide all questions which may arise relative to the classifications
and measurements of quantities and materials and the fulfillment of this contract and (4) shall have the power
to reject or condemn all work or material which does not conform to the terms of this contract. his or her estimate
and decision in all matters shall be a condition precedent to an appeal for arbitration, or the right of the Contractor
to receive, demand, or claim any money or other compensation under this agreement and a condition precedent
to any liability on the part of the City to the Contractor on account of this contract. Whenever the Engineer shall
be unable to act, in consequence of absence or other cause, then such engineer as the Engineer or the City
shall designate, shall perform any and all of the duties and be vested with any or all of the powers herein given
to the Engineer.
7-02. Inspection. The City will provide engineering personnel for the inspection of the work.
The Engineer and his or her representatives shall at all times have access to the work whenever it is in
preparation or progress and the Contractor shall provide proper facilities for such access and inspection.
If the Special Provisions, the Engineer's instruction, laws, ordinances, or any public authority require any work
to be specially tested or approved, the Contractor shall give the Engineer timely notice of its readiness for
Page 188 of 390
COUNCIL CHAMBER AV REPLACEMENT 14 Spec. No. 20-09
inspection and, if the inspection is by an authority other than the Engineer, of the date fixed for such inspection.
Inspections by the Engineer shall be promptly made at the source of supply where practicable. If any work shall
be covered up without approval or consent of the Engineer, it must, if required by the Engineer, be uncovered
for examination and properly restored at the Contractor's expense.
Re-examination of any work may be ordered by the Engineer and, if so ordered, the work must be uncovered
by the Contractor. If such work is found to be in accordance with the contract documents, the City shall pay the
cost of re-examination and replacement. If such work is not in accordance with the contract documents, the
Contractor shall pay such cost.
Properly authorized and accredited inspectors shall be considered to be the representatives of the City limited
to the duties and powers entrusted to them. It will be their duty to inspect materials and workmanship of those
portions of the work to which they are assigned, either individually or collectively, under instructions of the
Engineer and to report any and all deviations from the Drawings, Special Provisions and other contract
provisions which may come to their notice. Any inspector may be considered to have the right to order the work
entrusted to his or her supervision stopped, if in his or her opinion such action becomes necessary, until the
Engineer is notified and has determined and ordered that the work may proceed in due fulfillment of all contract
requirements.
7-03. Surveys. Contractor shall furnish all land surveys, establish all base lines and bench marks and make
sufficient detailed surveys needed for working points, lines and elevations. The Contractor shall develop all slope
stakes and batter boards. Contractor shall also develop all additional working points, lines and elevations as he
or she may desire to facilitate his or her methods and sequence of construction.
7-04. Rights-of-Way. The City will provide all necessary rights-of-way and easements in or beneath which
work will be performed by the Contractor under this contract.
7-05. Retention of Imperfect Work. If any portion of the work done or material furnished under this contract
shall prove defective and not in accordance with the Plans and Special Provisions, and if the imperfection in the
same shall not be of sufficient magnitude or importance to make the work dangerous or undesirable, the
Engineer shall have the right and authority to retain such work instead of requiring the imperfect work to be
removed and reconstructed, but he or she shall make such deductions therefor in the payments due or to
become due the Contractor as may be just and reasonable.
7-06. Changes in the Work. The Engineer shall have the right, in writing, to order additions to, omissions from,
or corrections, alterations and modifications in the line, grade, form, dimensions, plan, or kind or amount of work
or materials herein contemplated, or any part thereof, either before or after the beginning of construction.
However, the arithmetical sum of the cost to the City of additions and subtractions from the work under this
contract shall not exceed 10 percent of original contract amount or $5,000, whichever is the greater, unless
based upon a supplementary agreement to be made therefore.
The order of such additions, omissions, corrections, alterations and modifications shall be in writing and signed
by the Engineer and, in order, shall then be binding upon the Contractor. The Contractor shall proceed with the
work as changed and the value of such change shall be determined as provided for in section 10-07 of these
Special Provisions.
Such alterations shall in no way affect, vitiate, or make void this contract or any part thereof, except that which
is necessarily affected by such alterations and is clearly the evident intention of the parties to this contract.
7-07. Additional Drawings by City. The drawings made a part of this contract at the time of its execution are
intended to be fairly comprehensive and to indicate in more or less detail the scope of the work. In addition to
these drawings, however, the Engineer shall furnish such additional drawings from time to time during the
progress of the work as are necessary to make clear or to define in greater detail the intent of the Special
Provisions and the contract drawings and the Contractor shall make his or her work conform to all such drawings.
7-08. Additional and Emergency Protection. Whenever, in the opinion of the Engineer, the Contractor has
not taken sufficient precautions for the safety of the public or the protection of the works to be constructed under
this contract, or of adjacent structures or property which may be injured by the processes of construction on
account of such neglect and whenever, in the opinion of the Engineer, an emergency shall arise and immediate
Page 189 of 390
COUNCIL CHAMBER AV REPLACEMENT 15 Spec. No. 20-09
action shall be considered necessary in order to protect public or private, personal or property interest, then and
in that event, the Engineer, with or without notice to the Contractor may provide suitable protection to the said
interests by causing such work to be done and such material to be furnished as shall provide such protection as
the Engineer may consider necessary and adequate.
The cost and expense of such work and material so furnished shall be borne by the Contractor and, if the same
shall not be paid on presentation of the bills therefor, then such costs shall be deducted from any amounts due
or to become due the Contractor.
The performance of such emergency work under the direction of the Engineer shall in no way relieve the
Contractor from any damages which may occur during or after such precaution has been taken by the Engineer.
7-09. Suspension of Work. The City may at any time suspend the work or any part thereof by giving five (5)
days written notice to the Contractor. The work shall be resumed by the Contractor within ten (10) days after the
date fixed in the written notice from the City to the Contractor so to do. The City shall reimburse the Contractor
for expense incurred by the Contractor in connection with the work under this contract as a result of such
suspension.
If the work, or any part thereof, shall be stopped by the notice in writing aforesaid and if the City does not give
notice in writing to the Contractor to resume work at a date within ten (10) days of the date fixed in the written
notice to suspend, then the Contractor may abandon that portion of the work so suspended and he or she will
be entitled to the estimates and payments for all work done on the portions so abandoned, if any, plus 5 percent
of the value of the work so abandoned, to compensate for loss of overhead, plant expense and anticipated profit.
7-10. Right of City to Terminate Contract. If the Contractor should be adjudged a bankrupt, or if he or she
should make a general assignment for the benefit of his or her creditors, or if a receiver should be appointed on
account of his or her insolvency, or if he or she should persistently or repeatedly refuse or should fail, except in
cases for which extension of time is provided, to supply sufficient properly skilled workmen or proper materials,
or if he or she should fail to make prompt payments to subcontractors or for material or labor, or persistently
disregard laws, ordinances or the instructions of the Engineer, or otherwise be guilty of a substantial violation of
any provision of the contract, then the City, upon the certificate of the Engineer that sufficient cause exists to
justify such action, may, without prejudice to any other right or remedy and after giving the Contractor seven
days written notice, terminate the employment of the Contractor and take possession of the premises and of all
materials, tools and appliances and finish the work by whatever method the City may deem expedient. In such
case, the Contractor shall not be entitled to receive any further payment until the work is finished. If the unpaid
balance of the contract price shall exceed the expense of finishing the work, including compensation for
additional managerial and administrative services, such excess shall be paid to the Contractor. If such expense
shall exceed such unpaid balance, the Contractor shall pay the difference to the City. The expense incurred by
the City as herein provided and the damage incurred through the Contractor's default, shall be certified by the
Engineer.
7-11. Use of Completed Portions. The City shall have the right to take possession of and use any completed
or partially completed portions of the work, notwithstanding the time for completing the entire work or such
portions which may not have expired; but such taking possession and using shall not be deemed an acceptance
of any work not completed in accordance with the contract documents. If such prior use increases the cost of or
delays the work, the Contractor shall be entitled to such extra compensation, or extension of time or both, as the
Engineer may determine.
SECTION 8. WORKMANSHIP, MATERIALS and EQUIPMENT
8-01. General Quality. Materials and equipment shall be new and of a quality equal to that specified or
approved. Work shall be done and completed in a thorough and workmanlike manner.
8-02. Quality in Absence of Detailed Specifications. Whenever under this contract it is provided that the
Contractor shall furnish materials or manufactured articles or shall do work for which no detailed specifications
are set forth, the materials or manufactured articles shall be of the best grade in quality and workmanship
obtainable in the market from firms of established good reputation, or, if not ordinarily carried in stock, shall
conform to the usual standards for first-class materials or articles of the kind required, with due consideration of
Page 190 of 390
COUNCIL CHAMBER AV REPLACEMENT 16 Spec. No. 20-09
the use to which they are to be put. In general, the work performed shall be in full conformity and harmony with
the intent to secure the best standard of construction and equipment of the work as a whole or in part.
8-03. Materials and Equipment Specified by Name. Whenever any material or equipment is indicated or
specified by patent or proprietary name or by the name of the manufacturer, such specification shall be
considered as used for the purpose of describing the material or equipment desired and shall be considered as
followed by the words "or approved equal". The Contractor may offer any material or equipment which shall be
equal in every respect to that specified, provided that written approval first is obtained from the Engineer.
8-04. Source of Materials. Price, fitness and quality being equal, preference shall be given by the Contractor
for supplies grown, manufactured or produced in the State of California and, next, for such products partially
produced in this State in accordance with Government Code Section 4332.
8-05. Storage of Materials. Materials shall be so stored to ensure the preservation of their quality and fitness
for the work. They shall be so located and disposed that prompt and proper inspection thereof may be made.
8-06. Drawings, Samples and Tests. As soon as possible after execution of the contract, the Contractor shall
submit to the Engineer, in quintuplicate, sufficient information including, if necessary, assembly and detail
drawings to demonstrate fully that the equipment and materials to be furnished comply with the provisions and
intent of these Special Provisions and Drawings. If the information thus submitted indicates the equipment or
materials is acceptable, the Engineer will return one copy stamped with his or her approval; otherwise, one copy
will be returned with an explanation of why the equipment or material is unsatisfactory. The Contractor shall
have no claims for damages or for extension of time on account of any delay due to the revision of drawings or
rejection of material. Fabrication or other work performed in advance of approval shall be done entirely at the
Contractor's risk. After approval of equipment or material, the Contractor shall not deviate in any way from the
design and specifications given without the written consent of the Engineer.
When requested by the Engineer, a sample or test specimens of the materials to be used or offered for use in
connection with the work shall be prepared at the expense of the Contractor and furnished by him or her in such
quantities and sizes as may be required for proper examination and tests, with all freight charges prepaid and
with information as to their sources.
All samples shall be submitted before shipment and in ample time to permit the making of proper tests, analyses,
or examination before the time at which it is desired to incorporate the material into the work. All tests of materials
furnished by the Contractor shall be made by the Engineer. Samples shall be secured and tested whenever
necessary to determine the quality of the material.
SECTION 9. PROSECUTION OF WORK
9-01. Equipment and Methods. The work under this contract shall be prosecuted with all materials, tools,
machinery, apparatus and labor and by such methods as are necessary to the complete execution of everything
described, shown, or reasonably implied. If at any time before the beginning or during the progress of the work,
any part of the Contractor's plant or equipment, or any of his or her methods of execution of the work, appear to
the Engineer to be unsafe, inefficient, or inadequate to insure the required quality or the rate of progress of the
work, he or she may order the Contractor to increase or improve his or her facilities or methods and the
Contractor shall comply promptly with such orders; but, neither compliance with such orders nor failure of the
Engineer to issue such orders shall relieve the Contractor from his or her obligation to secure the degree of
safety, the quality of the work and the rate of progress required of the Contractor. The Contractor alone shall be
responsible for the safety, adequacy and efficiency of his or her plant, equipment and methods.
9-02. Time of Completion. The Contractor shall promptly begin the work under this contract and shall complete
and make ready for full use all portions of the project made the subject of this contract within the time set forth
in the agreement bound herewith.
9-03. Avoidable Delays. Avoidable delays in the prosecution or completion of the work shall include all delays
which might have been avoided by the exercise of care, prudence, foresight and diligence on the part of the
Contractor. The City will consider as avoidable delays within the meaning of this contract (1) delays in the
prosecution of parts of the work, which may in themselves be unavoidable, but do not necessarily prevent or
delay the prosecution of other parts of the work nor the completion of the whole work within the time herein
Page 191 of 390
COUNCIL CHAMBER AV REPLACEMENT 17 Spec. No. 20-09
specified, (2) reasonable loss of time resulting from the necessity of submitting plans to the Engineer for approval
and from the making of surveys, measurements, inspections, and testing and (3) such interruptions as may
occur in the prosecution of the work on account of the reasonable interference of other contractors employed by
the City which do not necessarily prevent the completion of the whole work within the time herein specified.
9-04. Unavoidable Delays. Unavoidable delays in the prosecution or completion of the work under this contract
shall include all delays which may result, through cause beyond the control of the Contractor and which he or
she could not have provided against by the exercise of care, prudence, foresight and diligence. Orders issued
by the City changing the amount of work to be done, the quantity of material to be furnished or the manner in
which the work is to be prosecuted and unforeseen delays in the completion of the work of other contractors
under contract with the City will be considered unavoidable delays, so far as they necessarily interfere with the
Contractor's completion of the whole of the work. Delays due to normally adverse weather conditions will not be
regarded as unavoidable delays. However, truly abnormal amounts of rainfall, temperatures or other weather
conditions for the location of the work and time of year may be considered as unavoidable delays if those
conditions necessarily cause a delay in the completion of the work.
9-05. Notice of Delays. Whenever the Contractor foresees any delay in the prosecution of the work and, in
any event, immediately upon the occurrence of any delay which the contractor regards as an unavoidable delay,
he or she shall notify the Engineer in writing of the probability of the occurrence of such delay and its cause, in
order that the Engineer may take immediate steps to prevent, if possible, the occurrence or continuance of the
delay, or, if this cannot be done, may determine whether the delay is to be considered avoidable or unavoidable,
how long it continues and to what extent the prosecution and completion of the work are to be delayed thereby.
9-06. Extension of Time. Should any delays occur which the Engineer may consider unavoidable, as herein
defined, the Contractor shall, pursuant to his or her application, be allowed an extension of time proportional to
said delay or delays, beyond the time herein set forth, in which to complete this contract; and liquidated damages
for delay shall not be charged against the Contractor by the City during an extension of time granted because
of unavoidable delay or delays.
Any claim by Contractor for a time extension based on unavoidable delays shall be based on written notice
delivered to the Engineer within 15 days of the occurrence of the event giving rise to the claim. Failure to file
said written notice within the time specified shall constitute a waiver of said claim. Notice of the full extent of the
claim and all supporting data must be delivered to the Engineer within 45 days of the occurrence unless the
Engineer specifies in writing a longer period. All claims for a time extension must be approved by the Engineer
and incorporated into a written change order.
9-07. Unfavorable Weather and Other Conditions. During unfavorable weather and other conditions, the
Contractor shall pursue only such portions of the work as shall not be damaged thereby. No portions of the work
whose satisfactory quality or efficiency will be affected by any unfavorable conditions shall be constructed while
these conditions remain, unless, by special means or precautions approved by the Engineer, the Contractor
shall be able to overcome them.
The Contractor shall be granted a time extension of one day for each unfavorable weather day which prevents
him or her from placing concrete forms or placing and finishing concrete or asphalt concrete. Such unfavorable
weather day is defined as a rain day where precipitation prevents the contractor from performing the work more
than four (4) continuous hours within the authorized work period or a temperature day where the ambient
temperature is below that specified for the placement of materials associated with the controlling work item for
more than four (4) continuous work hours of the authorized work period.
9-08. Saturday, Sunday, Holiday and Night Work. No work shall be done between the hours of 6 p.m. and
7 a.m., nor on Saturdays, Sundays or legal holidays except such work as is necessary for the proper care and
protection of work already performed, or except in cases of absolute necessity and in any case only with the
permission of the Engineer.
It is understood, however, that night work may be established as a regular procedure by the Contractor if he or
she first obtains the written permission of the Engineer and that such permission may be revoked at any time by
the Engineer if the Contractor fails to maintain at night adequate force and equipment for reasonable prosecution
and to justify inspection of the work.
Page 192 of 390
COUNCIL CHAMBER AV REPLACEMENT 18 Spec. No. 20-09
9-09. Hours of Labor. Eight (8) hours of labor shall constitute a legal day's work and the Contractor or any
subcontractor shall not require or permit more than eight hours of labor in a day from any person employed by
him or her in the performance of the work under this contract, unless paying compensation for all hours worked
in excess of eight (8) hours per day at not less than 1½ times the basic rate of pay. The Contractor shall forfeit
to the City, as a penalty, the sum of twenty-five dollars ($25.00) for each workman employed in the execution of
the contract by him or her or by any subcontractor, for each calendar day during which such laborer, workman,
or mechanic is required or permitted to labor more than eight hours in violation of the provisions of Section 1810
to 1816, inclusive, (Article 3, Chapter 1, Part 7, Division 2) of the Labor Code of the State of California and any
acts amendatory thereof.
SECTION 10. PAYMENT
10-01. Certification by Engineer. All payments under this contract shall be made upon the presentation of
certificates in writing from the Engineer and shall show that the work covered by the payments has been done
and the payments thereof are due in accordance with this contract.
10-02. Progress Estimates and Payment. The Engineer shall, within the first seven (7) days of each month,
make an estimate of the value of the work performed in accordance with this contract during the previous
calendar month.
The first estimate shall be of the value of the work satisfactorily completed in place and meeting the requirements
of the contract. And every subsequent estimate, except the final estimate, shall be of the value of the work
satisfactorily completed in place since the last preceding estimate was made; provided, however, that should
the Contractor fail to adhere to the program of completion fixed in this contract, the Engineer shall deduct from
the next and all subsequent estimates the full calculated accruing amount of the liquidated damages to the date
of said estimate, until such time as the compliance with the program has been restored.
The estimate shall be signed by the Engineer and, after approval, the City shall pay or cause to be paid to the
Contractor in the manner provided by law, an amount equal to 95 percent of the estimated value of the work
satisfactorily performed and complete in place.
10-03. Substitution of Securities.
1. At such times that Pubic Contract Code Section 22300 is in effect Contractor may propose the substitution
of securities of at least equal market value for any moneys to be withheld to ensure performance under the
Contract. Market value shall be determined as of the day prior to the date such substitution is to take place.
Such substitution shall be made at the request and expense of the Contractor. The securities shall be one or
more of the following types:
(a) Bonds or interest-bearing notes or obligations of the United States, or those for which the faith and
credit of the United States are pledged for the payment of principal and interest.
(b) Bonds or interest-bearing notes on obligations that are guaranteed as to principal and interest by a
federal agency of the United States.
(c) Bonds of the State of California, or those for which the faith and credit of the State of California are
pledged for the payment of principal and interest.
(d) Bonds or warrants, including, but not limited to, revenue warrants, of any county, city, metropolitan
water district, California water district, California water storage district, irrigation district in the State of
California, municipal utility district, or school district of the State of California, which are rated by Moody's
or Standard and Poor as A or better.
(e) Bonds, consolidated bonds, collateral trust debentures, consolidated debentures, or other
obligations issued by federal land banks or federal intermediate credit banks established under the
Federal Farm Loan Act, as amended; debentures and consolidated debentures issued by the Central
Bank for Cooperatives and banks for cooperatives established under the Farm Credit Act of 1933, as
amended; bonds, or debentures of the Federal Home Loan Bank Board established under the Federal
Home Loan Bank Act; and stock, bonds, debentures and other obligations of the Federal National
Page 193 of 390
COUNCIL CHAMBER AV REPLACEMENT 19 Spec. No. 20-09
Mortgage Association established under the National Housing Act as amended and bonds of any
Federal Home Loan Mortgage Corporation.
(f) Commercial paper of "prime" quality as defined by a nationally recognized organization which rates
such securities. Eligible paper is further limited to issuing corporations: (1) organized and operating
within the United States; (2) having total assets in excess of five hundred million dollars ($500,000,000);
and (3) approved by the Pooled Money Investment Board of the State of California. Purchases of eligible
commercial paper may not exceed 180 days' maturity, nor represent more than 10 percent of the
outstanding paper of an issuing corporation.
(g) Bills of exchange or time drafts on and accepted by a commercial bank, otherwise known as bankers
acceptances, which are eligible for purchase by the Federal Reserve System.
(h) Certificates of deposits issued by a nationally or state-chartered bank or savings and loan
association.
(i) The portion of bank loans and obligations guaranteed by the United States Small Business
Administration or the United States Farmers Home Administration.
(j) Student loan notes insured under the Guaranteed Student Loan Program established pursuant to
the Higher Education Act of 1965, as amended (20 U.S.C. 1001, et seq.) and eligible for resale to the
Student Loan Marketing Association established pursuant to Section 133 of the Education Amendments
of 1972, as amended (20 U.S.C. 1087-2).
(k) Obligations issued, assumed or guaranteed by International Bank for Reconstruction and
Development, the Inter-American Development Bank, the Asian Development Bank, or the Government
Development Bank of Puerto Rico.
(l) Bonds, debentures and notes issued by corporations organized and operating within the United
States. Such securities eligible for substitution shall be within the top three ratings of a nationally
recognized rating service.
2. The securities shall be deposited with City or with any commercial bank as escrow agent, who shall arrange
for transfer of such securities to the Contractor upon satisfactory completion of the contract. Any interest accrued
or paid on such securities shall belong to the Contractor and shall be paid upon satisfactory completion of the
contract.
The market value of the securities deposited shall at all times be maintained in an amount at least equal, in the
sole judgment of City, to the moneys to be withheld pursuant to the Contract Documents to ensure performance
of the Contract. In order to comply with this condition, Contractor shall deposit additional securities as necessary
upon request by City or the escrow agent.
3. Upon acceptance of any Proposal that includes substituting securities for amounts withheld to ensure
performance, a separate escrow agreement satisfactory in form and substance to City shall be prepared and
executed by City, the Contractor and the escrow agent, which may be City. The escrow agreement shall specify,
among other matters, value of securities to be deposited; procedures for valuing the securities and for adding or
withdrawing securities to maintain the market value of the deposited securities at least equal to the amount of
moneys which would otherwise be withheld; the terms and conditions of conversion to cash in case of the default
by the Contractor; and terms, conditions and procedure for termination of the escrow. City shall have no
obligation to enter any such Agreement that does not provide the City with the unilateral right to convert securities
to cash and to gain immediate possession of the cash.
10-04. Acceptance. The work must be accepted by vote of the City Council of the City of Ukiah when the
whole shall have been completed satisfactorily. The Contractor shall notify the Engineer, in writing, of the
completion of the work, whereupon the Engineer shall promptly, by personal inspection, satisfy himself as to the
actual completion of the work in accordance with the terms of the contract and shall thereupon recommend
acceptance by the City Council.
Page 194 of 390
COUNCIL CHAMBER AV REPLACEMENT 20 Spec. No. 20-09
10-05. Final Estimate and Payment. The Engineer shall, as soon as practicable after the final acceptance of
the work done under this contract, make a final estimate of the amount of work done thereunder and the value
thereof.
Such final estimate shall be signed by the Engineer, and after approval, the City shall pay or cause to be paid
to the Contractor, in the manner provided by law, the entire sum so found to be due hereunder, after deducting
therefrom all previous payments and such other lawful amounts as the terms of this contract prescribe.
In no case will final payment be made in less than thirty-five (35) days after the filing of the notice of completion
with the County Recorder.
10-06. Delay Payments. Should any payment due the Contractor or any estimate be delayed, through fault of
the City beyond the time stipulated, such delay shall not constitute a breach of contract or be the basis for a
claim for damages, but the City shall pay the Contractor interest on the amount of the payment at the rate of 6
percent per annum for the period of such delay. The terms for which interest will be paid shall be reckoned, in
the case of any monthly or progress payment, from the twentieth day of the month next succeeding the month
in which the work was performed to the date of payment of the estimate; and in the case of the final estimate,
from the forty-fifth day after acceptance to the date of payment of the final estimate.
The date of payment of any estimate shall be considered the day on which the payment is offered or mailed as
evidenced by the records of the Treasurer of the City. If interest shall become due on any delayed payment, the
amount thereof, as determined by the City, shall be added to a succeeding payment. If the interest shall become
due on the final payment, it shall be paid on a supplementary voucher to interest or any sum or sums which, by
the terms of this contract, the City is authorized to reserve or retain.
10-07. Extra Work and Work Omitted. Whenever corrections, alterations, or modifications of the work under
this contract ordered by the Engineer and approved by the City increase the amount of work to be done, such
added work shall be known as "extra work"; and when such corrections, alterations, or modifications decrease
the amount of work to be done, such subtracted work shall be known as "work omitted".
When the Contractor considers that any changes ordered involve extra work, he or she shall immediately notify
the Engineer in writing and subsequently keep him or her informed as to when and where extra work is to be
performed and shall make claim for compensation therefor each month not later than the first day of the month
following that in which the work claimed to be extra work was performed and he or she shall submit a daily
complete statement of materials and labor used and expenses incurred on account of extra work performed,
showing allocation of all materials, labor and expenses.
All such claims shall state the date of the Engineer's written order and the date of approval by the City authorizing
the work on account of which claim is made. Unless such notification is made in writing within the time specified
and unless complete statements of materials used and expenses incurred on account of such extra work are
furnished as above required, the Contractor shall not be entitled to payment on account of extra work and
Contractor shall be deemed to have waived the right to make any future claims for compensation for such extra
work.
When changes decrease the amount of work to be done, they shall not constitute a claim for damages on
account of anticipated profits on the work that may be omitted.
10-08. Compensation for Extra Work or Work Omitted. Whenever corrections, additions, or modifications
in the work under this contract change the amount of work to be done or the amount of compensation due the
Contractor, excepting increases or decreases in contract items having unit contract prices for each measurable
quantity installed in place, and such changes have been ordered in writing by the Engineer and approved by the
City prior to the Contractor performing the extra work, then a price may be agreed upon. Failing such an
agreement in price, the Contractor shall be compensated for performing extra work pursuant to the provisions
of Section 4-1.03 D,"Extra Work", and Section 9-1.03,"Force Account Payment" of the Standard Specifications.
This method of determining the price of work shall not apply to the performance of any work which is required
or reasonably implied to be performed or furnished under this contract.
Page 195 of 390
COUNCIL CHAMBER AV REPLACEMENT 21 Spec. No. 20-09
10-09. Compensation to the City for Extension of Time. In case the work called for under this contract is
not completed within the time limit stipulated herein, the City shall have the right as provided hereinabove, to
extend the time of completion thereof. If the time limit be so extended, the City shall have the right to charge to
the Contractor and to deduct from the final payment for the work the actual cost to the City of engineering,
inspection, superintendence and other overhead expenses which are directly chargeable to the contract and
which accrue during the period of such extension, except that the cost of final unavoidable delays shall not be
included in such charges.
10-10. Liquidated Damages for Delay. It is agreed by the parties to the contract that time is of the essence
and that, in case all the work is not completed before or upon the expiration of the time limit as set forth, damage,
other than those cost items identified in section 10-09, will be sustained by the City and that it is and will be
impracticable to determine the actual amount of damage by reason of such delay; and it is therefore agreed that
the Contractor will pay to the City the sum of five hundred dollars ($500.00) per day for each and every calendar
day's delay beyond the time prescribed.
SECTION 11. MISCELLANEOUS
11-01. Notice. Whenever any provision of the contract documents requires the giving of written notice, it shall
be deemed to have been validly given if delivered in person to the individual or to a member of the firm or to an
officer of the corporation for whom it is intended, or if delivered at or sent by registered or certified mail, postage
prepaid, to the last business address known to the giver of the notice. If mailed, the notice shall be deemed
received on the date of delivery stated in the return receipt.
11-02. Computation of Time. When any period of time is referred to in the Contract Documents by days, it
shall be computed to exclude the first and include the last day of such period. If the last day of any such period
falls on a Saturday or Sunday or on a day made a legal holiday by the law of the applicable jurisdiction, such
day shall be omitted from the computation.
11-03. Claims Procedure Required by Public Contract Code Section 9204. This section shall apply to any
claim by the Contractor arising in connection with this project in accordance with Public Contract Code Section
9204.
a, For purposes of this section "Claim" means a separate demand by the Contractor sent by registered mail or
certified mail with return receipt requested, for one or more of the following:
(A) A time extension, including, without limitation, for relief from damages or penalties for delay
assessed by the City under this contract.
(B) Payment by the City of money or damages arising from work done by, or on behalf of, the Contractor
pursuant to this contract and payment for which is not otherwise expressly provided or to which the Contractor
is not otherwise entitled.
(C) Payment of an amount that is disputed by the City.
b.
(1)
(A) Upon receipt of a claim pursuant to this section, the City shall conduct a reasonable review
of the claim and, within a period not to exceed 45 days, shall provide the Contractor a written statement
identifying what portion of the claim is disputed and what portion is undisputed. Upon receipt of a claim, a public
entity and the contractor may, by mutual agreement, extend the time period provided in this subdivision.
(B) The Contractor shall furnish reasonable documentation to support the claim.
(C) If the City needs approval from its governing body to provide the Contractor a written
statement identifying the disputed portion and the undisputed portion of the claim, and the governing body does
not meet within the 45 days or within the mutually agreed to extension of time following receipt of a claim sent
Page 196 of 390
COUNCIL CHAMBER AV REPLACEMENT 22 Spec. No. 20-09
by registered mail or certified mail, return receipt requested, the City shall have up to three days following the
next duly publicly noticed meeting of the governing body after the 45-day period, or extension, expires to provide
the claimant a written statement identifying the disputed portion and the undisputed portion.
(D) Any payment due on an undisputed portion of the claim shall be processed and made within
60 days after the City issues its written statement. If the City fails to issue a written statement, paragraph (3)
shall apply.
(2)
(A) If the Contractor disputes the City's written response, or if the City fails to respond to a claim
issued pursuant to this section within the time prescribed, the Contractor may demand in writing an informal
conference to meet and confer for settlement of the issues in dispute. Upon receipt of a demand in writing sent
by registered mail or certified mail, return receipt requested, the City shall schedule a meet and confer
conference within 30 days for settlement of the dispute.
(B) Within 10 business days following the conclusion of the meet and confer conference, if the
claim or any portion of the claim remains in dispute, the City shall provide the claimant a written statement
identifying the portion of the claim that remains in dispute and the portion that is undisputed. Any payment due
on an undisputed portion of the claim shall be processed and made within 60 days after the public entity issues
its written statement. Any disputed portion of the claim, as identified by the contractor in writing, shall be
submitted to nonbinding mediation, with the City and the Contractor sharing the associated costs equally. The
City and Contractor shall mutually agree to a mediator within 10 business days after the disputed portion of the
claim has been identified in writing. If the parties cannot agree upon a mediator, each party shall select a
mediator and those mediators shall select a qualified neutral third party to mediate with regard to the disputed
portion of the claim. Each party shall bear the fees and costs charged by its respective mediator in connection
with the selection of the neutral mediator. If mediation is unsuccessful, the parts of the claim remaining in dispute
shall be subject to applicable procedures outside this section.
(C) For purposes of this section, mediation includes any nonbinding process, including, but not
limited to, neutral evaluation or a dispute review board, in which an independent third party or board assists the
parties in dispute resolution through negotiation or by issuance of an evaluation. Any mediation utilized shall
conform to the timeframes in this section.
(D) Unless otherwise agreed to in writing by the City and the Contractor, the mediation
conducted pursuant to this section shall excuse any further obligation under Public Contract Code Section
20104.4 to mediate after litigation has been commenced.
(3) Failure by the City to respond to a claim from the Contractor within the time periods described in
this subdivision or to otherwise meet the time requirements of this section shall result in the claim being deemed
rejected in its entirety. A claim that is denied by reason of the public entity's failure to have responded to a claim,
or its failure to otherwise meet the time requirements of this section, shall not constitute an adverse finding with
regard to the merits of the claim or the responsibility or qualifications of the Contractor.
(4) Amounts not paid in a timely manner as required by this section shall bear interest at 7 percent per
annum.
(5) If a subcontractor or a lower tier subcontractor lacks legal standing to assert a claim against a public
entity because privity of contract does not exist, the Contractor may present to the public entity a claim on behalf
of a subcontractor or lower tier subcontractor. A subcontractor may request in writing, either on his or her own
behalf or on behalf of a lower tier subcontractor, that the Contractor present a claim for work which was
performed by the subcontractor or by a lower tier subcontractor on behalf of the subcontractor. The subcontractor
requesting that the claim be presented to the public entity shall furnish reasonable documentation to support the
claim. Within 45 days of receipt of this written request, the Contractor shall notify the subcontractor in writing as
to whether the Contractor presented the claim to the public entity and, if the original contractor did not present
the claim, provide the subcontractor with a statement of the reasons for not having done so.
c. A waiver of the rights granted by this section is void and contrary to public policy, provided, however, that
(1) upon receipt of a claim, the parties may mutually agree to waive, in writing, mediation and proceed directly
Page 197 of 390
COUNCIL CHAMBER AV REPLACEMENT 23 Spec. No. 20-09
to the commencement of a civil action or binding arbitration, as applicable; and (2) the City may prescribe
reasonable change order, claim, and dispute resolution procedures and requirements in addition to the
provisions of this section, so long as the contractual provisions do not conflict with or otherwise impair the
timeframes and procedures set forth in this section.
11-04. Litigation and Forum Selection. Contractor and City stipulate and agree that any litigation relating to
the enforcement or interpretation of this contract, arising out of Contractor's performance or relating in any way
to the work shall be brought in Mendocino County and that venue will lie in Mendocino County.
Except as otherwise expressly provided by law, the parties waive any objections they might otherwise have to
the propriety of jurisdiction or venue in the state courts in Mendocino County and agree that California law shall
govern any such litigation.
The duties and obligations imposed by these General Conditions and the rights and remedies available
hereunder to the parties hereto and, in particular but without limitation, the warranties, guaranties and obligations
imposed upon the Contractor and all of the rights and remedies available to the City thereunder, shall be in
addition to and shall not be construed in any way as a limitation of, any rights and remedies available to any or
all of them which are otherwise imposed or available by law or contract, by special warranty or guaranty, or by
other provisions of the contract documents and the provisions of this paragraph shall be as effective as if
repeated specifically in the contract documents in connection with each particular duty, obligation, right and
remedy to which they apply. All warranties and guaranties made in the contract document shall survive final
payment and termination or completion of this contract. The City disclaims an express or implied warranty that
the plans and specifications identify all site conditions that could affect the time or cost to complete the Work.
11-05. Waiver. The Contractor shall strictly comply with all notices and other contract requirements. Waiver by
the City of any failure of the Contractor to comply with any term of the contract, including the notice provisions,
shall not be deemed a waiver of a subsequent breach.
Page 198 of 390
COUNCIL CHAMBER AV REPLACEMENT 24 Spec. No. 20-09
TECHNICAL SPECIFICATIONS
SECTION 12. GENERAL INFORMATION
12-01. Location and Scope of Work. All of the work to be performed is within the City of Ukiah and consists
of the replacement of the audiovisual systems in the existing office conference rooms and City Council chambers
of the Civic Center building. General location of the work is at the City of Ukiah Civic Center located at 300
Seminary Avenue, Ukiah, California 95482.
The Contractor should familiarize himself with the local conditions of the project sites. Failure to do so will in no
way relieve him of the responsibility for performing any of the work or operations required as a part of this
contract. Further information regarding the work or these specifications can be obtained from Mary Horger at
(707) 463-6233.
12-02. Arrangement of Technical Specifications. The Technical Specifications are arranged in sections
covering the various phases of work as follows:
Section No. Title
12 General Information
13 Construction Details
14 Exclusions from General Conditions
15 Amendments to General Conditions
12-03. Arrangement of Plans. General locations and linear quantities of the work are shown in Appendix "A".
A map will be provided to the successful bidder showing the exact locations of the work to be done.
12-04. Business Licenses. The Contractor and any subcontractors shall each secure and maintain a valid
City of Ukiah Business License prior to the start of any portion of the work.
12-05. Permits. The Contractor shall provide, procure, and pay for all permits required to complete this work.
12-06. Standard Specifications and Standard Plans. The Standard Specifications and Standard Plans of
the California State Department of Transportation, 2015, are hereby made a part of these Special Provisions
and are hereinafter referred to as "California Standard Specifications" and "California Standard Plans."
Whenever in the California Standard Specifications and the California Standard Plans the following terms are
used, they shall be understood to mean and refer to the following:
Department of Transportation - The City Council.
Director of Public Works - The City of Ukiah Director of Public Works.
Engineer - The Engineer, designated by the City Council, acting either directly or through properly authorized
agents, such agents acting within the scope of the particular duties entrusted to them.
Laboratory - The designated laboratory authorized by the City of Ukiah to test materials and work involved in the
contract.
State - The City of Ukiah
Other terms appearing in the California Standard Specifications and the California Standard Plans shall have
the intent and meaning specified in Section I, Definition of Terms of the California Standard Specifications.
In case of discrepancy between the contract documents, the order of precedence from the highest to lowest is
as follows:
1. (City) Special Provisions
Page 199 of 390
COUNCIL CHAMBER AV REPLACEMENT 25 Spec. No. 20-09
2. (City) Project Plans
3. City Standard Plans and Details
4. California Standard Plans
5. California Standard Specifications
12-07. Temporary Facilities. All temporary facilities are the responsibility of the Contractor. The removal of
said facilities shall be the responsibility of the Contractor. The Contractor shall be responsible for any and all
damages to existing facilities which are a result of the work.
12-08. Public Convenience and Safety. The Contractor shall conduct operations so as to cause the least
possible obstruction and inconvenience to public traffic. The Contractor shall, at his or her expense, furnish such
flag persons and furnish, erect, construct and maintain such fences, barriers, lights, signs, detours, pedestrian
walkways, driveway ramps and bridging as may be necessary to give adequate warning to the public that work
is in progress and that dangerous conditions exist, to provide access to abutting properties and to permit the
flow of pedestrian and vehicular traffic to safely and expeditiously pass the work.
12-09. Maintaining Traffic. Attention is directed to Section 7-1.08, "Public Convenience," 7-1.09, "Public
Safety," 7-1.092, "Lane Closure," and 7-1.095, "Flagging Costs," of the California Standard Specifications.
Streets shall be open to through vehicular traffic during non-working hours. All public traffic shall be permitted to
pass through the work with as little inconvenience and delay as possible.
Full costs for "Maintaining Traffic", including "Flagging Costs", shall be considered as included in the various
items of work and no additional compensation will be made.
12.10. Stream Pollution. The Contractor shall exercise every reasonable precaution to prevent muddying or
silting of live streams, and the Contractor's attention is called to the fact that the terms of this contract do not
relieve him or her of responsibility for compliance with Sections 5650 and 12015 of the Fish and Game Code or
other applicable statutes relating to pollution prevention or abatement.
12-11. Warranties. Unless otherwise indicated, the Contractor shall warrant all materials provided and work
performed under this contract for a period of one year from the date of final acceptance. He shall replace
promptly and at his own expense any materials and/or workmanship which fail during this warranty period.
12-12. Utilities. No water, sewer or electrical services will be provided by the owner. It is the Contractor's sole
responsibility to arrange such services as necessary.
12-13. Preconstruction Conference. A preconstruction conference will be held before any work will be allowed
to commence. This meeting will cover inspection, schedule for work, and among other items, the responsibilities
and procedures of each of the interested parties to assure that the project will be completed in accordance with
the contract documents.
12-14. Safety Requirements. The Contractor shall comply with all pertinent provisions of the Department of
Labor "Safety and Health Regulations for Construction (29 FCS Part 1518, 36 CFR 7340)", with additions or
modifications thereto, in effect during construction of this project.
Page 200 of 390
COUNCIL CHAMBER AV REPLACEMENT 26 Spec. No. 20-09
SECTION 13 - CONSTRUCTION DETAILS
13-01. Technical Specifications. Refer to Appendix B and Appendix C.
SECTION 14. EXCLUSIONS FROM GENERAL CONDITIONS
14-01. Provisions to be Excluded from General Conditions. The following designated provisions of the
General Conditions are hereby determined to be inapplicable to the proposed work and, therefore, are hereby
excluded from the terms of the Notice to Bidders, Proposal, Agreement and other contract documents as though
entirely omitted from said General Conditions:
(1) Section 6-02. Office at the Site
(2) Section 7-03. Surveys
No other exclusions.
SECTION 15. AMENDMENTS TO GENERAL CONDITIONS
15-01. Sections of General Conditions to be Amended.
The following designated sections of the Special Provisions are hereby amended to read as follows:
No amendments.
Page 201 of 390
COUNCIL CHAMBER AV REPLACEMENT 27 Spec. No. 20-09
BID SUBMITTAL CHECKLIST
The following is a checklist to assist you in your submission of your bid documents. Please make sure you
include the following when submitting your bid documents to reduce the risk of having your bid rejected:
Did you include?...
o Proposal (Page 27)
Unit prices filled out clearly.
Extended prices filled out clearly and calculated correctly
Total bid amount filled out clearly and calculated correctly
If providing “or equal”, supplied supporting documentation as required
Sign the proposal, and provide complete information
CLSB No. and expiration date
Department of Industrial Relations Public Works Contractor Registration Number
o Fair Employment Practices Certification (Page 30)
Filled out completely per instruction
o Worker’s Compensation Certificate (Page 31)
Filled out completely per instruction
o Certification of Non-Discrimination in Employment (Page 32)
Filled out completely per instruction
o List of Proposed Subcontractors (Page 33)
Filled out completely per instruction
o Statement of Experience (Page 34)
o Signature of Bidder (Page 35)
Filled out completely per instruction
Authorized signature provided
o Bidder’s Bond (Page 36)
Filled out completely per instruction
o Non-Collusion Affidavit (Page 37)
Filled out completely per instruction
Notarized
o Additional Information to be Submitted with Bid Return: refer to Appendix A, Section 274100,
Par1, Sub-Section 1.5.
o Addenda Issued
Check the City website for any addenda issued: www.cityofukiah.com/purchasing.
Page 202 of 390
COUNCIL CHAMBER AV REPLACEMENT 28 Spec. No. 20-09
CITY OF UKIAH
MENDOCINO COUNTY, CALIFORNIA
PROPOSAL
FOR
COUNCIL CHAMBER AV REPLACEMENT
Specification No. 20-09
The undersigned, as bidder,
declares that he or she has examined thoroughly all of the contract documents herein contained, that this
proposal is made without collusion with any other person, firm or corporation and that all laws and ordinances
relating to the interest of public officers in this contract have been complied with in every respect.
AND he or she proposes and agrees, if this proposal is accepted,
1) that he or she will contract with the City of Ukiah, Mendocino County, California, in the form of the
copy of the agreement herein contained
a) to provide all necessary machinery, tools, apparatus and other means of construction;
b) to furnish all materials;
c) to provide all superintendence, overhead expenses and all labor and expenses of whatever
nature necessary to complete the job in conformity with the specifications and drawings and
other contract provisions herein or reasonably implied hereby or as necessary to complete
the work in the manner and within the time named herein and according to the requirements
and to the reasonable satisfaction of the City Engineer;
d) to pay all charges of freight transportation and hauling;
2) that he or she indemnifies the City against any loss or damage arising from any act of the
undersigned as Contractor; and
3) that he or she will accept as full payment therefor the following sums:
Page 203 of 390
COUNCIL CHAMBER AV REPLACEMENT 29 Spec. No. 20-09
BIDDING SCHEDULE
In the case of any discrepancy between the unit price and the total set forth for the item, the unit price shall
prevail; provided, however, that if the amount set forth as a unit price is ambiguous, unintelligible or uncertain
for any reason, or is omitted, or in the case of lump sum items, is not the same amount as the entry in the “Total”
column, then the amount set forth in the “Total” column for the item shall prevail in accordance with the following:
1. As to lump sum items, the amount set forth in the “Total” column shall be the unit price;
2. As to unit basis items, the amount set forth in the “Total” column shall be divided by the estimated
quantity for the item and the price thus obtained shall be the unit price.
The Total Base Bid shall be the sum of the items in the “Total” column. In case of discrepancy between the sum
of the items in the “Total” column and the amount entered as Total Base Bid, the sum of the “Total” column items
shall prevail. The bid comparison will be based on the sum of the items in the “total” column for each bidder.
The Unit prices for the various Construction Items below include all costs associated with the General
Conditions, Special Provisions, Requirements of the Construction Contract, and represent the total, complete,
in-place cost for each specific Construction Item in accordance with the Construction Documents, including all
elements, work components, accessories, and connections, shown in applicable details or required to yield a
complete, sound and functional component or system appropriate for its intended function, whether or not such
is specifically described or listed in any description of measurement or payment. The total amount of the
Construction items below shall represent the total and complete cost of the fully functional Project. All work not
specifically listed below be required to complete the work of the various construction items and the cost of such
shall be considered as included throughout the various unit prices indicated.
Lowest bid will be based on the lowest Base Bid.
Page 204 of 390
COUNCIL CHAMBER AV REPLACEMENT 30 Spec. No. 20-09
NAME OF BIDDER:
SPEC #: 20-09
PROJECT NAME: COUNCIL CHAMBER AV REPLACEMENT
PLEASE REFER TO APPENDIX A FOR MASTER PRICING TABLE,
AND SUPPORTING PRICING SCHEDULES TO SUBMIT WITH YOUR BID.
We, the undersigned, acknowledge that the City Council has reserved the right to reject any or all bids and to
determine which proposal is, in its opinion, the lowest responsive bid from a responsible bidder and that which
it deems in the best interest of the City to accept. We, the undersigned, further agree, if this proposal shall be
accepted, to sign the agreement and to furnish the required bonds with satisfactory surety, or sureties, within
fifteen (15) calendar days after written notice that the contract is ready for signature; and, if the undersigned
shall fail to contract, as aforesaid, it shall be understood that he or she has abandoned the contract and that,
therefore, this proposal shall be null and void and the proposal guaranty accompanying this proposal, or the
amount of said guaranty, shall be forfeited to and become the property of the City. Otherwise, the proposal
guaranty accompanying this proposal shall be returned to the undersigned.
Witness our hands this day of ___________________, 20____.
Licensed in accordance with an act providing for the registration of California Contractors License No.
___________, expiration date _____________.
THE CONTRACTOR'S LICENSE NUMBER AND EXPIRATION DATE STATED HEREIN ARE MADE UNDER
PENALTY OF PERJURY.
Department of Industrial Relations Public Works Contractor Registration Number:_____________________
Signature of bidder or bidders, with business name, address, and phone number:
By: _____________________________________________________________
Print Name: _______________________________________________________
Company Name: _______________________________ Address: __________________________________
City: _________________ Zip: _________________Phone #:
Notice: In the case of a corporation, give below the addresses of the principal office thereof and names and
addresses of the President, Secretary, Treasurer.
Corporations:
Address of principal office:
Name and address of President:
Name and address of Secretary:
Name and address of Treasurer:
Page 205 of 390
COUNCIL CHAMBER AV REPLACEMENT 31 Spec. No. 20-09
FAIR EMPLOYMENT PRACTICES CERTIFICATION
TO:_____________________________________________________________
________________________________________________________________
The undersigned, in submitting a bid for performing the following work by Contract, hereby certifies that he or
she has or will meet the standards of affirmative compliance with the Fair Employment Practices requirements
of the Special Provisions contained herein.
COUNCIL CHAMBER AV REPLACEMENT
By ________________________________________________________________
(Signature of Bidder)
Business Name: _________________________________________________
Business Mailing Address:
_______________________________________
Business Location:
_________________________________________________
_________________________________________________
(The bidder shall execute the certification of this page prior to submitting his or her proposal.)
Page 206 of 390
COUNCIL CHAMBER AV REPLACEMENT 32 Spec. No. 20-09
WORKER'S COMPENSATION CERTIFICATE
I am aware of the provisions of Section 3700 of the Labor Code which require every employer to be insured
against liability for Worker's Compensation or undertake self-insurance in accordance with the provisions of that
code and I will comply with such provisions before commencing the performance of the work of this contract.
Witness my hand this________ day of _______________, 20____
By ________________________________________________________________
(Signature of Bidder)
Business Name: _________________________________________________
Business Mailing Address:
_______________________________________
Page 207 of 390
COUNCIL CHAMBER AV REPLACEMENT 33 Spec. No. 20-09
CERTIFICATION OF NONDISCRIMINATION IN EMPLOYMENT
The bidder represents that he or she has/has not, participated in a previous contract or subcontract subject to
either the equal opportunity clause herein or the clause contained in Section 301 of Executive Order 10925; that
he or she has/has not, filed all required compliance reports; and that representations indicating submission of
required compliance prior to subcontract awards.
Witness my hand this________ day of _______________, 20____
By ________________________________________________________________
(Signature of Bidder)
Business Name: _________________________________________________
Business Mailing Address:
_______________________________________
(This certification shall be executed by the bidder in accordance with Section 60-1.6 of the Regulations of the
President's Committee on Equal Employment Opportunity for implementing Executive Orders 10925 and
11114.)
Page 208 of 390
COUNCIL CHAMBER AV REPLACEMENT 34 Spec. No. 20-09
LIST OF PROPOSED SUBCONTRACTORS
In compliance with the provisions of Sections 4100-4108 of the California Public Contract Code and any
amendments thereof, each bidder shall set forth (a) the name and location of the place of business of each
subcontractor who will perform work or labor or render service in or about the construction site or a subcontractor
licensed by the State of California who, under subcontract to the prime contractor, specially fabricates and
installs a portion of the work or improvement according to detailed drawings contained in the plans and
specifications in an amount in excess of one-half of 1 percent of the total bid and (b) the California Contractor
License Number for each subcontractor, and (c) the portion of the work to be done by each subcontractor.(See
General Conditions Section 1-09.) Include with the name of each sub-contractor their Department of Industrial
Relations Public Works Contractor Registration Number.
SUBCONTRACTO
R NAME
SUBCONTRACTO
R LICENSE
NUMBER
SUBCONTRACTO
R DIR
REGISTRATION
NUMBER
SUBCONTRACTO
R BUSINESS
ADDRESS
DESCRIPTIO
N OF WORK
Page 209 of 390
COUNCIL CHAMBER AV REPLACEMENT 35 Spec. No. 20-09
STATEMENT OF EXPERIENCE OF BIDDER
The bidder is required to provide information regarding work of similar magnitude or character he or she has
done and to give references that will enable the City Council to judge of his or her experience, skill and business
standing and his or her ability to conduct work as completely and rapidly as required under the terms of the
contract.
For qualifications requirements of Bidder, refer to Appendix B, Section 274100, Part 1, Sub-Section 1.3.
For required documentation to be submitted with the bid documents to establish that the bidder meets
the Qualifications requirements, please refer to Section 274100, Part 1, Sub-Section 1.5.B.
Page 210 of 390
COUNCIL CHAMBER AV REPLACEMENT 36 Spec. No. 20-09
SIGNATURE(S) OF BIDDER
Accompanying this proposal is ___________________________________
(insert the words "cash ($)", "cashier's check" or "bidder's bond", as the case may be) in an amount equal to at
least 10 percent of the bid.
The names of all persons interested in the foregoing proposal as principals are as follows:
IMPORTANT NOTICE: If bidder or other interested person is a corporation, provide the legal name of
corporation and also the names of the president, secretary, treasurer and manager thereof. If a co-partnership,
provide the true name of firm and also the names of all individual co-partners composing the firm. If bidder or
other interested person is an individual, provide the first and last names in full.
_________________________________________________________________
_________________________________________________________________
_________________________________________________________________
Licensed in accordance with an act providing for the registration of Contractors:
License No. ______________________________, License Expiration Date .
Signature(s) of Bidder: ______________________________________________
______________________________________________
______________________________________________
NOTE: If bidder is a corporation, the legal name of the corporation shall be set forth above together with
the signature of the officer or officers authorized to sign contracts on behalf of the corporation; if bidder
is a co-partnership, the true name of the firm shall be set forth above together with the signature of the
partner or partners authorized to sign contracts in behalf of the co-partnership; and if bidder is an
individual, his or her signature shall be placed above. If a member of a partnership, a Power of Attorney
must be on file with the Department prior to opening bids or submitted with the bid; otherwise, the bid
will be disregarded as irregular and unauthorized.
Business address: ___________________________________________________
___________________________________________________
Place of residence: ___________________________________________________
___________________________________________________
Dated: __________________
Page 211 of 390
COUNCIL CHAMBER AV REPLACEMENT 37 Spec. No. 20-09
CITY OF UKIAH
Mendocino County, California
BIDDER'S BOND
KNOW ALL MEN BY THESE PRESENTS,
That we, ______________________________________________________________
________________________________________________________________, as PRINCIPAL and
________________________________________________________________
________________________________________________________________, as SURETY,
are held and firmly bound unto the City of Ukiah in the penal sum of 10 PERCENT OF THE TOTAL AMOUNT
OF THE BID of the Principal above named, submitted by said Principal to the City of Ukiah, as the case may be,
for the work described below, for the payment of which sum in lawful money of the United States, well and truly
to be made, to the City Clerk to which said bid was submitted, we bind ourselves, our heirs, executors,
administrators and successors jointly and severally, firmly by these presents. In no case shall the liability of the
surety hereunder exceed the sum of $____________________
THE CONDITION OF THIS OBLIGATION IS SUCH,
That whereas the Principal has submitted the above-mentioned bid to the City of Ukiah, as aforesaid, for certain
construction specifically described as follows, for which bids are to be opened at the Office of the City Clerk,
Ukiah Civic Center, Ukiah, California, on August 18, 2020 for COUNCIL CHAMBER AV REPLACEMENT.
NOW, THEREFORE, If the aforesaid Principal is awarded the contract and, within the time and manner required
under the specifications, after the prescribed forms are presented to him or her for signatures, enters into a
written contract, in the prescribed form, in accordance with the bid and files two bonds with the City of Ukiah,
one to guarantee faithful performance and the other to guarantee payment for labor and materials, as required
by law, then this obligation shall be null and void; otherwise, it shall be and remain in full force and virtue.
IN WITNESS WHEREOF, we have hereunto set our hands and seals on this ______ day of ________________,
A.D. 20_____.
__________________________________________________(Seal)
__________________________________________________(Seal)
__________________________________________________(Seal)
Principal
__________________________________________________(Seal)
__________________________________________________(Seal)
__________________________________________________(Seal)
Surety
Address: __________________________________________________________
__________________________________________________________
__________________________________________________________
Page 212 of 390
COUNCIL CHAMBER AV REPLACEMENT 38 Spec. No. 20-09
NON-COLLUSION AFFIDAVIT
Note: Bidder shall execute the affidavit on this page prior to submitting his or her bid.
To City Council, City of Ukiah:
The undersigned in submitting a bid for performing Council Chamber AV Replacement by contract, being duly
sworn, deposes and says:
that he or she has not, either directly or indirectly, entered into any agreement, participated in any
collusion, or otherwise taken any action in restraint of free competitive bidding in connection with such
contract.
__________________________________________________
__________________________________________________
__________________________________________________
Signature(s) of Bidder
Business Address:__________________________________________________
__________________________________________________
__________________________________________________
Place of Residence:__________________________________________________
__________________________________________________
__________________________________________________
NOTARIZATION
Subscribed and sworn to before me this ______ day of _________, 20____.
__________________________________________________
Notary Public in and for the County of______________________________, State of California.
My Commission Expires ________________________, 20 ____.
Page 213 of 390
COUNCIL CHAMBER AV REPLACEMENT 39 Spec. No. 20-09
CITY OF UKIAH
Mendocino County, California
AGREEMENT
FOR
COUNCIL CHAMBER AV REPLACEMENT
Specification No. 20-09
THIS AGREEMENT, made this ______ day of ___________________, 20____, by and between the City of
Ukiah, Mendocino County, California, hereinafter called the City and _______________________ hereinafter
called the Contractor,
WITNESSETH:
WHEREAS, the City has caused to be prepared in accordance with law, specifications, drawings and other
contract documents for the work herein described and shown and has approved and adopted these contract
documents, specifications and drawings and has caused to be published in the manner and for the time required
by law a notice to bidders inviting sealed proposals for doing the work in accordance with the terms of this
contract and
WHEREAS, the Contractor, in response to the notice to bidders, has submitted to the City a sealed proposal
accompanied by a proposal guaranty in an amount of not less than 10 percent of the bid price for the construction
of the proposed work in accordance with the terms of this contract and
WHEREAS, the City, in the manner prescribed by law, has publicly opened, examined and canvassed the
proposals submitted and as a result has determined and declared the Contractor to be the lowest and best
regular responsible bidder for the work and for the sums named in the proposal,
NOW, THEREFORE, THIS AGREEMENT WITNESSETH:
Article 1. Work to be Done and Contract Days Allowed.
That the Contractor shall provide all necessary machinery, tools, apparatus and other means of construction;
shall furnish all materials, superintendence, overhead, expenses, all labor and expenses of whatever nature
necessary for completion of the work in conformity with the Special Provisions and other contract documents
hereto attached and according to such instructions as may be given by the Engineer. The Contractor shall
complete the work within sixty-three (63) calendar days. Contract days shall be counted starting with the 10th
day following receipt of notice that the contract has been executed by the City. Contractor, at his or her option,
may begin work prior to start of counting contract days, however, in no event shall the Contractor start work
without giving notification to the Engineer at least 72 hours prior to the start of work, without obtaining an
encroachment permit from the City, or without having submitted certificates of insurance that have been
accepted and approved by the Engineer
Page 214 of 390
COUNCIL CHAMBER AV REPLACEMENT 40 Spec. No. 20-09
Article II. Contract Prices.
That the City shall pay the Contractor the prices stated in the proposal submitted by the Contractor, for complete
performance of the contract by the Contractor. The Contractor hereby agrees to accept the prices as full
compensation for all material and appliances necessary to the work, for all labor and use of tools and other
implements necessary to execute the work contemplated in this contract; for all loss or damage arising out of
the nature of the work or from the action of the elements, or from any unforeseen obstructions or difficulties
which may be encountered in the prosecution of the work; for all risks of every description connected therewith;
for all expenses of the work, as herein specified; for all liability and other insurance, for all overhead and other
expenses incident to the work; all according to the Contract Drawings, the Special Provisions, the Details, the
instructions and the requirements of the City.
Article III. Labor Discrimination.
Attention is directed to Section 1735 of the Labor Code, which reads as follows:
"No discrimination shall be made in the employment of persons upon public works because of the race,
color, national origin or ancestry, or religion of such persons and every contractor for public works
violating this section is subject to all the penalties imposed for a violation of this chapter."
In connection with the performance of work under this contract, the Contractor agrees as follows:
(a) The Contractor will not willfully discriminate against any employee or an applicant for employment
because of race, color, religion, ancestry, or national origin. The Contractor will take affirmative
action to ensure that applicants are employed and that employees are treated during employment
without regard to their race, color, religion, ancestry, or national origin. Such action shall include,
but not be limited to, the following: employment, upgrading, demotion or transfer; recruitment or
recruitment advertising; layoff or termination; rates of pay or other forms of compensation; and
selection for training, including apprenticeship. The Contractor agrees to post in conspicuous
places, available to employees and applicants for employment, notices to be provided by the
awarding authority setting forth the provisions of this Fair Employment Practice section.
(b) The Contractor will send to each labor union or representative of workers with which he or she has
a collective bargaining agreement or other contract or understanding, a notice, to be provided by
the awarding authority, advising the said labor union or worker's representative of the Contractor's
commitments under this section, to employees and applicants for employment.
(c) The Contractor will permit access to his or her records of employment, employment
advertisements, application forms and other pertinent data and records by the Fair Employment
Practices Commission, City of Ukiah or any other appropriate agency of the State of California
designated by the awarding authority, for the purposes of investigation to ascertain compliance
with the Fair Employment Practices section of this contract.
(d) A finding of willful violation of the Fair Employment Practices section of this Contract or of the Fair
Employment Practices Act shall be regarded by the awarding authority as a basis for determining
the Contractor to be not a "responsible bidder" as to future contracts for which such Contractor
may submit bids, for revoking the Contractor's pre-qualification rating, if any and for refusing to
establish, reestablish or renew a pre-qualification rating for the Contractor.
The City of Ukiah shall deem a finding of willful receipt of written notice from the Fair Employment
Practices Act to have occurred upon that it has investigated and determined that the Contractor
Page 215 of 390
COUNCIL CHAMBER AV REPLACEMENT 41 Spec. No. 20-09
has violated the Fair Employment Practices Act and has issued an order under Labor Code Section
1426 or obtained an injunction under Labor Code Section 1429.
Upon receipt of such written notice from the Fair Employment Practices Commission, the City shall
notify the Contractor that unless he or she demonstrates to the satisfaction of the awarding
authority within a stated period that the violation has been corrected, his or her pre-qualification
rating will be revoked at the expiration of such period.
(e) The Contractor agrees that should the City determine that the Contractor has not complied with the
Fair Employment Practices section of this Contract, then pursuant to Labor Code Section 1735 and
1775 the Contractor shall, as a penalty to the City, forfeit for each calendar day or portion thereof,
for each person who was denied employment as a result of such non-compliance, the penalties
provided in the Labor Code for violation of prevailing wage rates. Such monies may be recovered
from the Contractor. The City may deduct any such damages from any monies due the Contractor.
(f) Nothing contained in this Fair Employment Practices section shall be construed in any manner of
fashion so as to prevent the City or the State of California from pursuing any other remedies that
may be available at law.
(g) Prior to awarding the Contract, the Contractor shall certify to the awarding authority that he or she
has or will meet the following standards for affirmative compliance, which shall be evaluated in
each case by the awarding authority:
(1) The Contractor shall provide evidence, as required by the City that he or she has notified all
supervisors, foremen and other personnel officers in writing of the content of the anti-discrimination
clause and their responsibilities under it.
(2) The Contractor shall provide evidence, as required by the City, that he or she has notified all
sources of employees’ referrals (including unions, employment agencies, advertisements,
Department of Employment) of the content of the anti-discrimination clause.
(3) The Contractor shall file a basic compliance report, as required by the City. Willfully false
statements made in such reports shall be punishable as provided by law. The compliance report
shall also spell out the sources of the work force and who has the responsibility for determining
whom to hire, or whether or not to hire.
(4) Personally, or through his or her representatives, the Contractor shall, through negotiations
with the unions with whom he or she has agreements, attempt to develop an agreement which will:
a. Spell out responsibilities for nondiscrimination in hiring, referral, upgrading and training.
b. Otherwise implement an affirmative anti-discrimination program in terms of the unions'
specific areas of skill and geography to the end that qualified minority workers will be available
and given and equal opportunity for employment.
(5) The Contractor shall notify the City of opposition to the anti-discrimination clause by individuals,
firms or organizations during the period of its pre-qualification.
(h) The Contractor will include the provisions of the foregoing paragraphs 1 through 5 in every first tier
subcontract so that such provisions will be binding upon each such subcontractor.
(i) The "Fair Employment Practices Certification" must be completed and signed prior to the time of
submitting the bid.
Page 216 of 390
COUNCIL CHAMBER AV REPLACEMENT 42 Spec. No. 20-09
Article IV. Parts of the Contract.
That the complete contract consists of the following documents, all of which shall be considered a part of this
agreement.
1. Notice to Bidders
2. Wage Rates
3. General Conditions
4. Technical Specifications
5. Proposal
6. Fair Employment Practices Certification
7. Agreement
8. Contract Bonds
9. Contract Drawings and Construction Details
10. Standard Drawings
11. Indemnification Agreement
IN WITNESS WHEREOF, this contract being executed in duplicate and the parties having caused their names
to be signed by authority of their duly authorized office this _____ day of _____________, 20____.
CITY OF UKIAH, MENDOCINO COUNTY, CALIFORNIA
By: ______________________________________________________________
CITY MANAGER, CITY OF UKIAH
Attest: ______________________________________________________________
CITY CLERK, CITY OF UKIAH
By: ______________________________________________________________
CONTRACTOR
Attest: ______________________________________________________________
Title: ______________________________________________________________
The foregoing contract is approved as to form and legality this ______ day of ______________, 20 ____.
__________________________________________________
CITY ATTORNEY, CITY OF UKIAH
Page 217 of 390
COUNCIL CHAMBER AV REPLACEMENT 43 Spec. No. 20-09
INDEMNIFICATION AGREEMENT
This Indemnification Agreement is made and entered in Ukiah, California, on _________________, 20____,
by and between the City of Ukiah (Ukiah) and _____________________________________ (Contractor).
Contractor is
_________________________________________________________________________________
___________________________________________ for Ukiah.
As a condition of issuing the work order, attached hereto, Ukiah requires assurance that Contractor will protect
Ukiah from damage or damage claims which arise from its performance of the work.
Accordingly, Contractor agrees as follows:
1. Indemnification. Contractor shall indemnify and hold harmless Ukiah and its officers, agents, and
employees from and against any claim, loss, or damage, including the legal and other costs of defending against
any claim of damage or loss which arises out of the Contractor’s negligent or wrongful performance under the
work order attached hereto, except for claims, losses, or damages resulting from the sole and exclusive
negligence or other wrongful conduct of Ukiah or its officers, agents and employees.
CONTRACTOR
BY: _______________________________________________
TITLE: _______________________________________________
Page 218 of 390
COUNCIL CHAMBER AV REPLACEMENT 44 Spec. No. 20-09
CITY OF UKIAH
Mendocino County, California
FAITHFUL PERFORMANCE BOND
KNOW ALL MEN BY THESE PRESENTS,
That we the undersigned, ______________________________________________________________
__________________________________________________________________________________,
AS PRINCIPAL, and
__________________________________________________________________________________,
AS SURETY,
are held firmly bound unto THE CITY OF UKIAH, hereinafter called the “City”, in the penal sum of
dollars ($____________________)
for the payment of which sum we bind ourselves, our heirs, executors, administrators, and successors, jointly
and severally.
WHEREAS, the Principal has entered into a certain Contract with the City, dated __________, 20_____,
a copy of which is hereto attached and made a part hereof,
NOW, THEREFORE, the condition of this obligation is such that if the Principal shall in all respects fully perform
the Contract and all duly authorized modifications thereof, during its original term and any extensions thereof
that may be granted and during any guaranty period for which the Contract provides, and if the Principal shall
fully satisfy all claims, arising out of the prosecution of the work under the Contract and shall fully indemnify the
City for all expenses which it may incur by reason of such claims, including its attorney's fees and court costs,
and if the Principal shall make full payment to all persons supplying labor, services, materials, or equipment in
the prosecution of the work under the Contract, in default of which such persons shall have a direct right of action
hereupon; and if the Principal shall pay or cause to be paid all sales and use taxes payable as a result of the
performance of the Contract as well as payment of gasoline and special motor fuels taxes in the performance of
the Contract and all motor vehicle fees required for commercial motor vehicles used in connection with the
performance of the Contract, then this obligation shall be void; otherwise, it shall remain in full force and effect.
No modification of the Contract or extension of the term thereof, nor any forbearance on the part of the City shall
in any way release the Principal or the Surety from liability hereunder. Notice to the Surety of any such
modification, extension, or forbearance is hereby waived.
IN WITNESS WHEREOF, the aforesaid Principal and Surety have executed this instrument and affixed their
seals hereto, this ________ day of _______________,20_______.
In the presence of:
WITNESS:
_________________________________
________________________________(SEAL)
(Individual Principal)
___________________________________
(Business Address)
___________________________________
(City/State/Zip Code)
Page 219 of 390
COUNCIL CHAMBER AV REPLACEMENT 45 Spec. No. 20-09
WITNESS:
____________________________________
______________________________(SEAL)
(Corporate Principal)
___________________________________
(Business Address)
___________________________________
(City/State/Zip Code)
ATTEST:
________________________________
(Corporate Principal) Affix
Corporate
Seal
___________________________________
(Business Address)
___________________________________
(City/State/Zip Code)
ATTEST:
____________________________ ________________________________ Affix
(Corporate Surety) Corporate
Seal
___________________________________
(Business Address)
___________________________________
(City/State/Zip Code)
The rate of premium on this bond is $___________________________ per thousand.
The total amount of premium charges is $____________________________..
(The above is to be filled in by Surety Company). (Power of Attorney of person signing for Surety Company must
be attached).
(CERTIFICATE AS TO CORPORATE PRINCIPAL)
I,_________________________________________, certify that I am the
______________________________ Secretary of the corporation named as Principal in the foregoing bond;
that _______________________________________, who signed the said bond on behalf of the Principal, was
then ____________________________________________ of said corporation; that I know his signature, and
that his signature thereto is genuine; and that said bond was duly signed, sealed, and attested to for and in
behalf of said corporation by authority of its governing body.
____________________________________________ Affix Corporate Seal
Page 220 of 390
COUNCIL CHAMBER AV REPLACEMENT 46 Spec. No. 20-09
CITY OF UKIAH
Mendocino County, California
MATERIAL AND LABOR BOND
KNOW ALL MEN BY THESE PRESENTS,
That we the undersigned, ______________________________________________________
__________________________________________________________________________, AS PRINCIPAL,
and
__________________________________________________________________________
__________________________________________________________________________, AS SURETY,
are held firmly bound unto THE CITY OF UKIAH, hereinafter called the “City” in the penal sum of
dollars ($____________________)
for the payment of which sum we bind ourselves, our heirs, executors, administrators, and successors, jointly
and severally.
WHEREAS, the Principal has entered into a certain Contract with the City, dated _________________,
20_____,
a copy of which is hereto attached and made a part hereof,
NOW, THEREFORE, the condition of this obligation is such that if the Principal shall in all respects fully perform
the Contract and all duly authorized modifications thereof, during its original term and any extensions thereof
that may be granted and during any guaranty period for which the Contract provides, and if the Principal shall
fully satisfy all claims, arising out of the prosecution of the work under the Contract and shall fully indemnify the
City for all expenses which it may incur by reason of such claims, including its attorney's fees and court costs,
and if the Principal shall make full payment to all persons supplying labor, services, materials, or equipment in
the prosecution of the work under the Contract, in default of which such persons shall have a direct right of action
hereupon; and if the Principal shall pay or cause to be paid all sales and use taxes payable as a result of the
performance of the Contract as well as payment of gasoline and special motor fuels taxes in the performance of
the Contract and all motor vehicle fees required for commercial motor vehicles used in connection with the
performance of the Contract, then this obligation shall be void; otherwise, it shall remain in full force and effect.
No modification of the Contract or extension of the term thereof, nor any forbearance on the part of the City shall
in any way release the Principal or the Surety from liability hereunder. Notice to the Surety of any such
modification, extension, or forbearance is hereby waived.
IN WITNESS WHEREOF, the aforesaid Principal and Surety have executed this instrument and affixed their
seals hereto, this ________ day of _______________,20_______.
In the presence of:
WITNESS:
____________________________________
________________________________(SEAL)
(Individual Principal)
___________________________________
(Business Address)
___________________________________
Page 221 of 390
COUNCIL CHAMBER AV REPLACEMENT 47 Spec. No. 20-09
(City/State/Zip Code)
WITNESS:
____________________________________
______________________________(SEAL)
(Corporate Principal)
___________________________________
(Business Address)
___________________________________
(City/State/Zip Code)
ATTEST:
________________________________
(Corporate Principal) Affix
Corporate
Seal
___________________________________
(Business Address)
___________________________________
(City/State/Zip Code)
ATTEST:
____________________________ ________________________________ Affix
(Corporate Surety) Corporate
Seal
___________________________________
(Business Address)
___________________________________
(City/State/Zip Code)
The rate of premium on this bond is $___________________________ per thousand.
The total amount of premium charges is $____________________________..
(The above is to be filled in by Surety Company). (Power of Attorney of person signing for Surety Company must
be attached).
(CERTIFICATE AS TO CORPORATE PRINCIPAL)
I,_________________________________________, certify that I am the
______________________________ Secretary of the corporation named as Principal in the foregoing bond;
that _______________________________________, who signed the said bond on behalf of the Principal, was
then ____________________________________________ of said corporation; that I know his signature, and
that his signature thereto is genuine; and that said bond was duly signed, sealed, and attested to for and in
behalf of said corporation by authority of its governing body.
____________________________________________ Affix Corporate Seal
Page 222 of 390
COUNCIL CHAMBER AV REPLACEMENT 48 Spec. No. 20-09
DIRECTIONS FOR PREPARATION OF PERFORMANCE AND MATERIAL AND LABOR BOND
1. Individual sureties, partnerships, or corporations not in the surety business will not be acceptable.
2. The name of the Principal shall be shown exactly as it appears in the Contract.
3. The penal sum shall not be less than required by the Specifications.
4. If the Principals are partners or joint venturers, each member shall execute the bond as an individual
and state his place of residence.
5. If the Principal is a corporation, the bond shall be executed under its corporate seal.
If the corporation has no corporate seal, it shall so state and affix a scroll or adhesive seal following the
corporate name.
6. The official character and authority of the person(s) executing the bond for the Principal, if a corporation,
shall be certified by the Secretary or Assistant Secretary thereof under the corporate seal, or copies
attached to such records of the corporation as will evidence the official character and authority of the
officer signing, duly certified by the Secretary or Assistant Secretary, under the corporate seal, to be
true copies.
7. The current power-of-attorney of the person signing for the surety company must be attached to the
bond.
8. The date of the bond must not be prior to the date of the Contract.
9. The following information must be placed on the bond by the surety company:
a. The rate of premium in dollars per thousand; and
b. The total dollar amount of premium charged.
10. The signature of a witness shall appear in the appropriate place attending to the signature of each party
of the bond.
11. Type or print the name underneath each signature appearing on the bond.
12. An executed copy of the bond must be attached to each copy of the Contract (original counterpart)
intended for signing.
Page 223 of 390
COUNCIL CHAMBER AV REPLACEMENT 49 Spec. No. 20-09
CITY OF UKIAH
Mendocino County, California
DEFECTIVE MATERIAL AND WORKMANSHIP (MAINTENANCE) BOND
KNOW ALL MEN BY THESE PRESENTS,
That we, _____________________________________________________________________
__________________________________________________________________, as PRINCIPAL
and__________________________________________________________________________
___________________________________________________________________, as SURETY,
are held and firmly bound unto the City of Ukiah as Obligee, in the penal sum of
___________________________________________________________________________________
_________________________________________________________($____________________),
(5 PERCENT OF THE FINAL CONTRACT AMOUNT)
to which payment well and truly to be made, we do bind ourselves, our and each of our heirs, executors,
administrators, successors and assigns jointly and severally, firmly by these presents.
WHEREAS, the said Principal entered into a Contract with the City of Ukiah
dated_________________________
for _________________________________________________________________________________
____________________________________________________________________________________
WHEREAS, said Contract has been completed, and was approved on the ______ day of ___________,
_________,
NOW, THEREFORE, THE CONDITION OF THIS OBLIGATION IS SUCH, that if the Principal shall guarantee
that the work will be free of any defective materials or workmanship which become apparent during the period
of one (1) year following completion of the Contract, then this obligation shall be void, otherwise to remain in full
force and effect, provided however, any additional warranty or guarantee whether expressed or implied is
extended by the Principal or Manufacturer only, and the surety assumes no liability for such a guarantee.
Signed, sealed, and dated this __________ day of ____________, 20_____.
__________________________________________________(Seal)
BY:_______________________________________________(Seal)
__________________________________________________(Seal)
Principal
__________________________________________________(Seal)
BY:_______________________________________________(Seal)
__________________________________________________(Seal)
Surety
Page 224 of 390
".9 :8-=,<2878/7;=:*7,.#.:>2,.;//2,.7,8:6
##%$ ))
$)%
"%"$#"$$#%"#$#%" )#$
($"$"$&"")$ #'
)
$$"
)
$$"
)
$$"
)
$$"
)
$$"
#%"
$##$"$)$$$ ##%"'&##%$$#%"&"$ ) "$$'$#$)
"!%"$$""$)$"$"$"%$'$"# $$'$#"$$)##%") "$$#%"")
$ ##""##%$$$$"#(%##$##% #$##')& "%) #
$"
$) #%"
)
%"
)$&
$ ))
( "$$
)) $#$%##
"$)
"
#
%""
'"B#$"$"B#
"$
$"
""$
"%$# #"$
"#&"$#%")
%"
"*7A87./2:.
( ##*7A87.9.:;87
%$$&$)
)%$
'%$#
#%%$#
"%$#
'%$#
"$)
#$
)%")9.:9.:;87
)%")9.:*,,2-.7<
" "$)
(##$)
%"
$"$
%""
%""
"$
'""B# #$
)"B# $)
#$$%$")
$
## )$
## )
" "$)
%"##$"%$
%$#%"
#" $ "$# $# &# "#$"$# # $#
87.8/<1.*+8>.-.;,:2+.-9852,2.;?255+.,*7,.5.-=7<25*/<.:
-*AB;?:2<<.778<2,.1*;+..702>.7<8<1.2<A*<<1.*--:.;;27-2,*<.-+.58?
$1.2<A2<;8//2,2*5;8//2,.:;.6958A..;*7->85=7<..:;*:.*--.-*;27;=:.-;87*552*+252<A7;=:*7,. 852,2.;52;<.-*+8>.
<2;*0:..-<1*<*7A27;=:*7,.8:;.5/27;=:*7,.6*27<*27.-+A<1.2<A?255*995A27.@,.;;8/*7-78<,87<:2+=<.?2<1<1.27;=:*7,.-.;,:2+.-*+8>.
$1.2<A2;7*6.-*58;;9*A..87$1. :89.:<A7;=:*7,. 852,2.;-.;,:2+.-*+8>.2/*7A
55:201<;8/;=+:80*<287=7-.:<1. :89.:<A7;=:*7,. 852,A52;<.-*+8>.1*>.+..7?*2>.-*0*27;<<1.2<A
$1.'8:4.:B;869.7;*<2877;=:.:7*6.-*+8>. 2/*7A*0:..;<8?*2>.*55:201<;8/;=+:80*<287*0*27;<<1.2<A/8:273=:2.;<8.6958A..;8/<1.27;=:.-:.;=5<270/:86?8:4/8:<1.2<A8:=;.8/<1.2<AB;
9:.62;.;8:/*,252<2.;
Page 225 of 390
+6 85*;):/545,49;8'4)+ +8</)+9,,/)+4)583
"!%
%"
!"
!./9+4*589+3+4:35*/,/+9/49;8'4)+685</*+*;4*+8:.+,5225=/4-
!%#!
"
'3+5,**/:/54'249;8+*+89549
588-'4/@':/549
5)':/5495,5<+8+*6+8':/549
/:?5,"1/'./:95,,/)+895,,/)/'29
+3625?++9'4*<52;4:++89
+3/4'8?<+4;+
"1/'.
,45+4:8? '66+'89'(5<+/4,583':/548+7;/8+*:5)5362+:+:./9+4*589+3+4:=/22(+9.5=4/4
+)2'8':/549'9'662/)'(2+:5:./9+4*589+3+4:
+):/54 $ "/9'3+4*+*:5/4)2;*+'9'4 '**/:/54'2 /49;8+*:.+6+895495858-'4/@':/5499.5=4/4:.+
).+*;2+(;:542?=/:.8+96+)::52/'(/2/:? ,58B(5*/2?/40;8?CB6856+8:?*'3'-+C58B6+8954'2'4*'*<+8:/9/4-/40;8?C'8/9/4-5;:5,B?5;8
=581C6+8,583+*,58:.':/49;8+*
5*/,/)':/549:5 ,583
!.+/49;8+*9).+*;2+*'(5<+/4)2;*+9:.+/49;8+*A9+2+):+*58'665/4:+*5,,/)+895,,/)/'29+3625?++9'4*<52;4:++89
!./9/49;8'4)+9.'22(+68/3'8?'98+96+):9:.+/49;8+*9.5=4/4:.+9).+*;2+'(5<+58/,+>)+999.'229:'4*/4'4
;4(851+4).'/4 5,)5<+8'-++>)+995,:.+'3+*49;8+*A99).+*;2+*;4*+82?/4-68/3'8?)5<+8'-+4+/:.+8+<+4:'4?
5:.+8/49;8'4)+3'/4:'/4+*(?:.+49;8+*9).+*;2+*'(5<+9.'22(+/4+>)+995,:./9/49;8'4)+'4*9.'2245:(+)'22+*
;654:5)54:8/(;:+=/:./:
!.+/49;8'4)+',,58*+*(?:./9652/)?9.'2245:(+)'4)+2+*+>)+6:',:+8:./8:?
*'?968/58=8/::+445:/)+(?)+8:/,/+*
3'/28+:;848+)+/6:8+7;+9:+*.'9(++4-/<+4:5:.+/:?
5<+8'-+9.'2245:+>:+4*:5'4?/4*+34/:?)5<+8'-+,58:.+'):/<+4+-2/-+4)+ 5,:.+'**/:/54'2/49;8+*/4'4?)'9+
=.+8+'4'-8++3+4::5/4*+34/,?:.+'**/:/54'2/49;8+*=5;2*(+/4<'2/*;4*+8 ;(*/</9/54(5, +):/54
5,:.+
/</25*+
&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&
/-4':;8+;:.58/@+*+68+9+4:':/<+
&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&
**8+99
&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&
&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&&
.54+;3(+8
49;8'4)+ +8</)+9,,/)+4)585*/,/+*
Page 226 of 390
;1<?@2:2;A <
6AF<3'86.5A52H6AFI@@B2.A2
"$!'$
&292=5<;2
"!+ !$&!
;@B?.;02<:=.;F
"<960F <
"<960F"2?6<13?<:A<
!%%'%& &*" %;09B1216;96:6A@
;.116A6<;A<96:6A@
21B0A6/92 %293;@B?21$2A2;A6<;05208D5605<3
%'$ ""&+&56@6;@B?.;02=2?A.6;@A<A52<=2?.A6<;.;1<?A2;.;0F<3
A52;.:216;@B?21B;12?.99D?6AA2;.4?22:2;A@.;1=2?:6A@6;3<?02D6A5A52
6AFB;92@@052082152?2 6;D56050.@2<;9FA523<99<D6;4@=206360
.4?22:2;A@.;1=2?:6A@D6A5A526AF.?20<C2?21
&+$ &%"$&%
&+"! %'$
!$
'% %%'&!"!+
!&$
!&$"$!(%! %
&!&+
=2?.00612;A3<?/<169F6;7B?F.;1=?<=2?AF1.:.42
%';12?D?6A2?G@?2=?2@2;A.A6C23<?09.6:@=B?@B.;AA<A56@6;@B?.;02
.:2
11?2@@
&292=5<;2
;0<;@612?.A6<;<3A52=?2:6B:05.?421.;1;<AD6A5@A.;16;4.;F6;0<;@6@A2;A@A.A2:2;A6;A52=<96AFA<D5605A56@2;1<?@2:2;A6@ .AA.0521<?.;F2;1<?@2:2;A;<D<?52?2.3A2?.AA.0521A52?2A<6A6@.4?221
.@3<99<D@
%'$&526AF6A@<33602?@<33606.9@2:=9<F22@.;1C<9B;A22?@.?26;09B121.@6;@B?21@D6A5?24.?1A<1.:.42@.;11232;@2<309.6:@.?6@6;43?<:A52<D;2?@56=<=2?.A6<;:.6;A2;.;02B@2
9<.16;4<?B;9<.16;4<3.;F.BA<<D;2192.12156?21<?/<??<D21/FA52 .:21;@B?21<?3<?D5605A52 .:21;@B?216@?2@=<;@6/92
! &$'&! !&$#'$@?2@=20A@D<?8=2?3<?:21/FA52 .:21;@B?213<?<?<;/25.93<3A526AFA526;@B?.;02.33<?121/FA56@=<960F@5.99./2=?6:.?F6;@B?.;02.@?2@=20A@A52
6AF6A@<33602?@<33606.9@2:=9<F22@.;1C<9B;A22?@<?/@A.;16;.;B;/?<82;05.6;<30<C2?.422E02@@<3A52 .:21;@B?21G@=?6:.?F0<C2?.42;F6;@B?.;02<?@2936;@B?.;02:.6;A.6;21/FA52
6AF6A@<33602?@<33606.9@2:=9<F22@.;1C<9B;A22?@@5.99/22E02@@<3A52 .:21;@B?21G@6;@B?.;02.;1;<A0<;A?6/BA2D6A56A
&! !&)6A5?2@=20AA<A526;A2?2@A@<3A526AFA56@6;@B?.;02@5.99;<A/20.;029212E02=A.3A2?A56?AF 1.F@=?6<?D?6AA2;;<A602/F?2026=A211296C2?F5.@/22;46C2;A<A526AF
%!"!!($&56@=<960F.33<?1@0<C2?.42.A92.@A.@/?<.1.@
3=?6:.?F6;@B?.;02%2?C602@!336023<?:;B:/2?
1
<12
.;F.BA< <?
32E02@@.33<?1@0<C2?.42D56056@.A92.@A.@/?<.1.@A52=?6:.?F6;@B?.;023<?:@?232?2;0216;A52=?20216;4@20A6<;
E02=A.@@A.A21./<C2;<A56;452?26;@5.99/25291A<D.6C2.9A2?<?2EA2;1.;F<3A5296:6A@0<;16A6<;@.4?22:2;A@<?2E09B@6<;@<3A52=<960FA<D5605A56@2;1<?@2:2;A6@.AA.0521
!$% &!$
&+
6AF<3'86.5
%2:6;.?FC2;B2
'86.5.963<?;6.
'&!$,?<82?42;A ';12?D?6A2?---------
$"$% &&(
=?6;AAF=2;.:2D.??.;AA5.A
5.C2.BA5<?6AFA</6;1A52./<C2:2;A6<;216;@B?.;020<:=.;F.;1/F:F
@64;.AB?252?2<;1<@</6;1A56@0<:=.;FA<A56@2;1<?@2:2;A
%64;.AB?2
<?646;.9 @64;.AB?2?2>B6?21
&292=5<;2 .A2@64;21
Page 227 of 390
1;@6.#21)0;0-B1;@C5,69:-4-5;6
::<-);-
#
"-3-7065-
& "
5:<9)5+-647)5@
631+@6
631+@-916,.964;6
!# " $!!
! #5,-9>91;-9A: 9-79-:-5;);1=- .69 +3)14: 7<9:<)5; ;6 ;01:
15:<9)5+-
)4-
,,9-::
"-3-7065-
& !"&"!
)+0++1,-5;
1:-):- 631+@141;
1:-):- )+04736@--
5+65:1,-9);165 6.;0-79-41<4+0)9/-,)5,56;>1;0:;)5,15/)5@15+65:1:;-5;:;);-4-5;15;0-7631+@;6>01+0;01:-5,69:-4-5;1:);;)+0-,69 )5@-5,69:-4-5;56>69
0-9-).;-9);;)+0-,;0-9-;61;1:)/9--,):.6336>:
"""01:15:<9)5+-:0)3356;*-+)5+-3-,-?+-7;).;-9;019;@ ,)@:79169>91;;-556;1+-*@9-+-17;-,,-31=-9@0):*--5/1=-5;6;0-1;@
%$ !# ""01:5:<9)5+-647)5@)/9--:;6>)1=-)3391/0;:6.:<*96/);165)/)15:;;0-1;@1;:6..1+-96..1+1)3:-4736@--: )5,=63<5;--9:.69
36::-:7)1,<5,-9;0-;-94:6.;01:7631+@>01+0)91:-.964;0->6927-9.694-,*@;0-)4-,5:<9-,.69;0-1;@
?+-7;)::;);-,)*6=-56;015/0-9-15:0)33*-0-3,;6>)1=-)3;-969-?;-5,)5@6.;0-3141;:+65,1;165:)/9--4-5;:69 -?+3<:165:6.;0-7631+@;6>01+0;01:-5,69:-4-5;1:
);;)+0-,
!"
"&
1;@6.#21)0
!-415)9@=-5<-
#21)0)31.6951)
#" '962-9/-5;#5,-9>91;-9
((((((((((
!""$
7915;;@7-5)4->)99)5;;0);
0)=-)<;0691;@;6*15,;0-)*6=-4-5;165-,15:<9)5+-+647)5@)5,*@4@
:1/5);<9-0-9-65,6:6*15,;01: +647)5@;6;01:-5,69:-4-5;
!1/5);<9-
691/15)3:1/5);<9-9-8<19-,
"-3-7065- );-:1/5-,
Page 228 of 390
P-2703 City of Ukiah California
Council Chambers AV Replacement
AREA QUANTITY of
SPACES
EQUIPMENT ENGINEERING PRE-INSTALL INSTALL G&A TAXES AREA TOTAL
27 41 20 - CITY OF UKIAH COUNCIL CHAMBERS:
AUDIOVISUAL SYSTEMS
1
27 41 30 - CITY OF UKIAH CONFERENCE ROOM 3:
AUDIOVISUAL SYSTEMS
1
27 41 35 - CITY OF UKIAH CONFERENCE ROOM 5:
AUDIOVISUAL SYSTEMS
1
27 41 00 - Training Costs, per Part 1.24 1
27 41 00 - Warranty
Year One (1) - Per Part 1.6 1
27 41 00 - Software Service Contract Costs, Per
3.3.D.2 1
27 41 20 - CITY OF UKIAH COUNCIL CHAMBERS: BID
ALTERNATE 'A'
1
27 41 00 - Warranty Year Two (2) - Per Part 1.7 1
27 41 00 - Warranty Year Three (3) - Per Part 1.7 1
27 41 00 - Warranty Year Four (4) - Per Part 1.7 1
27 41 00 - Warranty Year Five (5) - Per Part 1.7 1
ADD ALTERNATE 3
ADD ALTERNATE 4
ADD ALTERNATE 5
TOTAL BASE BID===>>>
Appendix A - P-2703 CITY OF UKIAH COUNCIL CHAMBERS AV REPLACEMENT
MASTER PRICING TABLE - 27 41 00 AUDIOVISUAL SYSTEMS
BASE BID
ADD ALTERNATE 1
ADD ALTERNATE 2
SECTION 27 41 00 - APPENDIX 'A'
AUDIOVISUAL SYSTEMS MASTER PRICING
PAGE 1 of 1
Page 229 of 390
P-2703 City of Ukiah California
Council Chambers AV Replacement
Item #Drawing/
Appendix Ref.Product Manuf.Model #Unit Qty Ext.
1 CSP-01 Control Processor - 3-series processor
with Ethernet dual-NIC, serial ports
Crestron - or equal
Specify :______________
CP3N - or equal
Specify:________________________1 __________
2 CP-01 Control Touch Panel - 10.1" diagonal, with
tabletop kit, black finish
Crestron - or equal
Specify:______________
TSW-1060-B-S, w/ TSW-1060-
TTK-B-S kit- or equal
Specify :______________
__________1 __________
3 IPS-01 Ethernet Switch - Rack-mounted 24-port
PoE+/PoE++,L3 managed switch,
stackable; 2 x 10 GE combo + 2 x 10GE
SFP+, PoE, PoE+, (8) 60w PoE (740W)
Cisco - or equal
Specify:______________
SG550X-24MPP - or equal
Specify:________________________1 __________
4 IPS-02 Ethernet Switch - 5-port unmanaged, pre-
configured AVB switch, for use with Biamp
AVB audio network interfaces; Dedicated
Ethernet port for network control/monitor
MOTU - or equal
Specify:______________
9305 -AVB Switch - or equal
Specify:________________________1 __________
5 CPC-01 Owner Furnished PC Computer - Small-
form-factor (Intel NUC), with undertable
mounting bracket, for use on-
network/credentialled access and UC/MS
Teams - Located under Secretary's dais
position
By Owner By Owner OFE/ETR/
FBO
1 OFE/ETR/
FBO
6 FPD-01 Flat panel display - 98" LCD, LED backlit,
350nit output, RS-232/IP control
NEC - or equal
Specify :______________
C981Q - or equal
Specify :________________________2 __________
7 FPD-01 Flat panel display mount - X-Large heavy-
duty fixed floor mount - bolt down type, for
98" flat panel display
Chief/LegrandAV - or equal
Specify :______________
XBM1U- or equal
Specify :________________________2 __________
8 FPD-02 Flat panel display - 75" LCD, LED backlit,
350nit output, RS-232/IP control
NEC - or equal
Specify :______________
C751Q - or equal
Specif y:________________________2 __________
9 FPD-02 Flat panel display mount - Large fixed wall
mount - thin-profile to meet ADA <4"
requirements, for 75" flat panel display
Chief/LegrandAV - or equal
Specify :______________
LSTU - or equal
Specify :________________________2 __________
10 FPD-03 Desktop Monitor - 22" LCD, LED backlit
panel, HD1080, 16:9 aspect, with HDMI
input, thin-bezel, 250nit output
NEC - or equal
Specify :______________
EA224WMI-BK - or equal
Specify :________________________9 __________
11 FPD-03 Desktop Monitor Stand - Adjustable angle,
low-profile, with VESA100x100 mount for
EA224 monitor
ErgoMart - or equal
Specify :______________
Limbo SL102 - VESA100mm- or
equal Specify :________________________9 __________
12 VP-01 Video Projector - HD Ceiling-mounted
Laser-lamped, DMD type unit, with
NEC - or equal
Specify :______________
NP-PA803UL with NP41ZL lens -
or equal
Specify :______________
__________1 __________
13 VP-01 Video Projector Ceiling Mount - Universal 5-
axis adjustable mount, include CMA ceiling
plate and 1.5" NPT adjustable pole as
required and verified in-field
Chief/LegrandAV - or equal
Specify :______________
RPMAUW - or equal
Specify :________________________1 __________
14 EPS-01 Motorized Projection Screen - Surface-
mount ceiling/wall, tensioned, 78"x139",
HD Progressive 1.3 surface, with 6" black
drop, with custom bracket to mount to
angled soffit (verify on-site). White finish,
integral LVC, no switch
Da-Lite/LegrandAV - or equal
Specify :______________
Tensioned Contuor Electrol -
24742L (with custom drop) - or
equal Specify :______________
__________1 __________
15 HDA-01 HDMI Distribution Amplifier - 1x8
HDMI2.0b/HDCP2.2; with undertable
mount
Crestron - or equal
Specify :______________
HD-DA8-4KZ-E - or equal
Specify :________________________1 __________
16 IPD-01 AV-over-IP Decoder Unit - PoE+; HDMI2.0
output, RS-232 control pass, undertable
mount
Crestron - or equal
Specify :______________
DM-NVX D30 - or equal
Specify :________________________6 __________
17 IPD-02/ IPE-02 AV-over-IP Encoder/Decoder Unit - PoE+;
HDMI2.0 (2) auto-switch input, (1) output,
USB2.0/KVM, Audio Breakaway RS-232
control pass, undertable mount
Crestron - or equal
Specify :______________
DM-NVX-350 - or equal
Specify :________________________2 __________
18 IPE-01 AV-over-IP Encoder Unit - PoE+; HDMI2.0
input, RS-232 control pass, undertable
mount
Crestron- or equal
Specify :______________
DM-NVX E30 - or equal
Specify :________________________4 __________
19 HDS-01 HDMI Switcher - 8x1, HDMI2.0b/HDCP2.2,
RS-232, with undermount kit
Extron - or equal
Specify :______________
SW8 HD 4k PLUS w/ UTS100 &
ZipClip50 for undertable
mounting - or equal
Specify :______________
__________1 __________
20 CAM-01 HD PTZ Camera - Invert ceiling mounted
unit with 1/2.86 CMOS sensor, 20x zoom,
PoE+, H.264/AVC streaming, HDMI, and
3G-SDI outputs, white finish
Panasonic - or equal
Specify :______________
AW-HE130WP - or equal
Specify :________________________1 __________
21 CAM-01 PTZ Camera Auto-Tracking Software,
desktop version for single camera install
Panasonic - or equal
Specify:______________
AW-SF100/200 - or equal
Specify:________________________1 __________
DISPLAY & VIDEO
Appendix A
27 41 20 - CITY OF UKIAH COUNCIL CHAMBERS: AUDIOVISUAL SYSTEMS
CONTROL
SECTION 27 41 20 - APPENDIX 'A'
AUDIOVISUAL SYSTEMS
PAGE 1 of 4
Page 230 of 390
P-2703 City of Ukiah California
Council Chambers AV Replacement
Item #Drawing/
Appendix Ref.Product Manuf.Model #Unit Qty Ext.
Appendix A
27 41 20 - CITY OF UKIAH COUNCIL CHAMBERS: AUDIOVISUAL SYSTEMS
22 CAM-02 HD PTZ Camera - Invert ceiling mounted
unit with 1/2.3 CMOS sensor, 30x zoom,
PoE+, H.264/AVC streaming, HDMI, and
USB outputs, white finish
Panasonic - or equal
Specify:______________
AW-HD40H(WPJ9) - or equal
Specify:________________________2 __________
23 N/A USB 3.0 Extension Cable - for connection
of CAM-02 to OPC-01 and OPC-01 to DSP-
01 for UC/Web-conferencing
Vaddio - or equal
Specify :______________
440-1005-023 - or equal
Specify :________________________2 __________
24 WPA-01 Wireless Presentation Appliance - 1 HDMI
input, 2 HDMI output, dual-NIC & local AP -
Include 3-years mfgr support in quote
Mersive - or equal
Specify :______________
Solstice POD Gen3 +Solstice
Subscription (3 yrs) - or equal
Specify :______________
__________1 __________
24 REC-01 Recording/Streaming Appliance - Rack-
mount, 2-HDMI input, dual-image/PIP
support, H.264/265 streaming, recording to
SD card, RTMP/RTSP support for client
CivicPlus software & cloud services
Epiphan - or equal
Specify :______________
Pearl Mini - or equal
Specify :________________________1 __________
25 HDA-02 HDMI Distribution Amplifier - 1x2
HDMI2.0b/HDCP2.2; with rack-mount kit
Extron - or equal
Specify :______________
DA2 HD 4k PLUS w/ RSU 126 &
ZipClip50 for undertable
mounting - or equal
Specify :______________
__________2 __________
26 SDI-01 HDMI-to-3/12G SDI Converter, with
embedded audio conversion to SDI
AJA - or equal
Specify :______________
HA5-12G - or equal
Specify :________________________1 __________
27 IPD-01 H.264/AVC Transmitter/Receiver-Decoder -
IP H.264 stream to HDMI 2.0 0utput with
embedded audio. Provide rack-mount kit
and mounting accessories
Crestron - or equal
Specify :______________
DM-TXRX-100-STR - or equal
Specify :________________________1 __________
28 MBU-2/ MIC-
03
Conferene Microphone & Base Unit - 20"
gooseneck cardioid capsule, mic-only base
unit with PTM/PTT & Request-to-Talk
buttons (RTT)
Shure- or equal
Specify :______________
MXCMIU-FS & MXC420DF/ - or
equal Specify :________________________1 __________
29 MBU-1/MIC-
01/02
Conferene Microphone & Base Unit - 16"
gooseneck cardioid capsule, mic &
speaker base unit with PTM/PTT &
Request-to-Talk buttons (RTT) - Qty 4 day-
one, with up to 5 additional as FUTURE
Shure - or equal
Specify :______________
MXCMIU-FL & MXC416DF/ - or
equal Specify :________________________8 __________
30 MIU-1 Conference Microphone Modular Interface
unit, for up to two flush front-plate units -
Provide with manufacturer cabling in
lengths required (Shure-only, no non-mfgr
CAT patch cabling allowed)
Shure - or equal
Specify :______________
MXCMIU w/mounting bracket &
EC-6001 cables in lengths as
required - or equal
Specify :______________
__________5 __________
31 CCU-01 Conference Microphone Central Control
Unit - Rackmount unit with analog I/O and
power supply to supply up to 60 units
Shure - or equal
Specify:______________
DIS-CCU w/PS-CCU - or equal
Specify :________________________1 __________
32 MIC-04 Ceiling Surface-mounted Beamforming
Microphones - Up to 4 tracking beam
elements per mic, Include in-ceiling
breakout/networking box per each 2-mics
Biamp - or equal
Specify :______________
Parle TCM-X (white) - or equal
Specify :________________________2 __________
33 MIC-04 Ceiling Surface-mounted Beamforming
Microphones - Up to 4 tracking beam
elements per mic, Expansion unit for each
TCM-X unit
Biamp - or equal
Specify :______________
Parle TCM-XEX (white) - or
equal Specify :________________________2 __________
34 WMR-01 Wireless Mic system w/ Beltpack
transmitter, Omnidirectional condenser
lavalier mic; with rcvr rackmount kit
Shure - or equal
Specify :______________
QLXD14/85 - or equal
Specify :________________________1 __________
35 WMR-01 Wireless Mic system w/ hand held
transmitter SM58 capsule; with rcvr
rackmount kit
Shure - or equal
Specify :______________
QLXD24/SM58 - or equal
Specify :________________________1 __________
36 MIC-05/WMR-
02
Wireless Mic Transmiter - Wireless
gooseneck basetype & 10" hypercardioid
gooseneck mic element, with QLXD4
receiver unit & rackmount kits
Shure - or equal
Specify :______________
QLXD8/MX410S & QLXD4 - or
equal Specify :________________________2 __________
37 WMR-02 Wireless Mic Transmiter - Surface
Boundary Layer type, with QLXD4 receiver
unit & rackmount kits
Shure - or equal
Specify :______________
QLXD6 & QLXD4 - or equal
Specify :________________________2 __________
32 RFD-1 Rackmount antenna distribution system for
QLX-D systems; include cabling & power
supplies as needed to power system
Shure - or equal
Specify :______________
UA845UWB - or equal
Specify :________________________2 __________
AUDIO
SECTION 27 41 20 - APPENDIX 'A'
AUDIOVISUAL SYSTEMS
PAGE 2 of 4
Page 231 of 390
P-2703 City of Ukiah California
Council Chambers AV Replacement
Item #Drawing/
Appendix Ref.Product Manuf.Model #Unit Qty Ext.
Appendix A
27 41 20 - CITY OF UKIAH COUNCIL CHAMBERS: AUDIOVISUAL SYSTEMS
33 ANT-1 Antennae, 1/2-wave dipole & mounting
bracket kit for mounting above accessible
ceiling (order model to match frequency
range chosen, based upon specification)
Shure - or equal
Specify :______________
UA505 & UA8 - or equal
Specify :________________________2 __________
34 DSP-1 Rackmount Audio DSP Unit - 12x8 Analog
I/O + 8 channels USB for UC/Web-
conferencing; AEC inputs, VoIP/SIP &
POTS interfaces; AVB audio networking
Biamp - or equal
Specify :______________
TesiraFORTE AVB VT - or equal
Specif y:________________________1 __________
35 ADA-01 Audio Distribution Amplifier - 1x3
Stereo/Mono output, Line, with Rackmount
kit
Extron - or equal
Specify :______________
MDA 3A -or equal
Specify :________________________1 __________
36 AMP-01 Audio Power Amplifier - 2 Channel, Low-Z,
100W per-channel, with rackmount kit
Extron - or equal
Specify :______________
XPA U1002 w/RSU 129 - or
equal Specify :________________________1 __________
37 ALS-01
38 ALS-02
39 S-01 Wall-mounted column loudspeakers - 2"x8
driver set, with wall-mount aiming brackets,
color-white
JBL-Pro -- or equal
Specify:______________
CBT-100LA-1-W- or equal
Specify :________________________2 __________
40 Portable Press Audio Distribution Box, Portable - 1
line input x 12 mic outputs, passive, in
ruggedized case with pass-thru
Whirlwind- or equal
Specify :______________
PB12- or equal
Specify :________________________1 __________
41 TTB-01 Flush Mount In-table Captive Cable and
Power Box - (2) HDMI captive cables;
Duplex 120V power + USB-C & USB-A
power; with bracket kit & undertable cable
cover kit
Extron- or equal
Specify :______________
Cable Cubby 1202 (70-1184-02,
w/60-1782-01, (2) 26-663-04, 70-
1040-03, 70-1080-02)- or equal
Specify:______________
__________5 __________
42 TTB-02 Flush Mount In-table Captive Cable and
Power Box - (1) HDMI captive cables; (2)
USB-A captive cables; Duplex 120V power
+ USB-C & USB-A power; with bracket kit
& undertable cable cover kit
Extron- or equal
Specify:______________
Cable Cubby 1202 (70-1184-02,
w/60-1782-01, (2) 26-663-04, 70-
1040-03, 70-1080-02)- or equal
Specify:______________
__________1 __________
43 TTB-03 Flush Mount In-table Captive Cable and
Power Box - (1) HDMI captive cable,
simplex 120V power
Extron- or equal
Specify:______________
Cable Cubby 202US (70-139-02,
26-663-06)- or equal
Specify:______________
__________1 __________
44 PP-01 CAT6A 10G Coupler PatchPanel - Normal
Density 24-port; Provide with 24" patch
cables in quantity
Panduit- or equal
Specify:______________
CP246X88BL- or equal
Specify :________________________1 __________
45 -Wireless Mic Transmitter Recharging
Station - for HH & Belt-pack units, or
Tabletop transmitter batteries
Shure- or equal
Specify :______________
SBC220-US- or equal
Specify :________________________1 __________
46 WP-02 Wall panel for XLR-M line out to portable
Press Feed box(es)
Pro-Co, RCI, Panelcrafters, etc…-
or equal Specify:______________
Custom __________2 __________
47 AER-01 Floor-standing AV Equipment Rack -
38RU, 23"W x 32"D, w/29" usable depth:
Include side/top panels, rear door, skirted
caster base, Rear-rack rail kit; all required
blank and vent panels; top fan cooling kit
with thermostat, and all required
accessories for a turnkey and finished,
closed rack
Middle Atlantic - or equal
Specify:______________
BGR-38SA-32 (w/BGR-RR38;
CBS-BGR; bgr-522FT-FC) - or
equal Specify:______________
__________1 __________
48 AER-01 Pull-out rack shelf - for Pearl Mini unit Middle Atlantic - or equal
Specify :______________
KB-SS - or equal
Specify :________________________1 __________
49 AER-01 Vertical PDU for rack - Distro from UPS-01 Middle Atlantic - or equal
Specify :______________
PD-2420SC-NS- or equal
Specify :________________________1 __________
50 AER-01 Rack Shelf for OFE PC - 4RU, adjustable
depth
Middle Atlantic - or equal
Specify :______________
U4V- or equal
Specify :________________________1 __________
51 AER-01 Rack drawer with foam insert for mic
storage - 2RU
Middle Atlantic - or equal
Specify :______________
D2 (w/FI-2 each)- or equal
Specify :________________________2 __________
52 TTB-01/03 Video Connector Adaptor Ring Set - (1)
DisplayPort male to HDMI female, (1) Mini-
DisplayPort male to HDMI female, (1) Mini-
HDMI "C" male to HDMI female, and (1)
Micro-HDMI "D" to HDMI female on
securing clamp 'ring' cable
Liberty AV- or equal
Specify :______________
DL-AR2- or equal
Specify :________________________8 __________
MISCELLANEOUS HARDWARE
Assistive Listening Kit - Combo FM (72-
76MHz)/Wi-Fi set with Wi-Fi server;
Signage; Cabling; (4) FM receivers
w/earphones & T-coil lanyards; charging kit
& power supplies
WilliamsAV - or equal
Specify :______________
FM 557 PRO ((1) FM T55 transmitter
(4) PPA R37N receivers
(4) EAR 022 surround earphones
(2) NKL 001 neckloops
(2) BAT KT6 two-bay chargers and
rechargeable batteries
(1) ANT 005 remote coaxial antenna
(1) IDP 008 ADA wall plaque
(1) RPK 005 rack panel kit)- or equal
Specify:______________
__________
1
__________
SECTION 27 41 20 - APPENDIX 'A'
AUDIOVISUAL SYSTEMS
PAGE 3 of 4
Page 232 of 390
P-2703 City of Ukiah California
Council Chambers AV Replacement
Item #Drawing/
Appendix Ref.Product Manuf.Model #Unit Qty Ext.
Appendix A
27 41 20 - CITY OF UKIAH COUNCIL CHAMBERS: AUDIOVISUAL SYSTEMS
53 PBB-01 Projector service enclosure and mounting
system - Provide with projector NPT pipe
receiver, 2RU mounting space, 5-gang
spaces for power/data/connectivity.
Provide with support cabling, safety
support cables, and 2x2 insert panel to
match ceiling
FSR Inc.- or equal
Specify:______________
CB-22P- or equal
Specif y:________________________1 __________
54 __________LOT __________
55 __________LOT __________
56 LTG-01 Lighting Control Keypad - for control of non-
dimming 277V main room fixtures
Crestron- or equal
Specify:______________
C2N-CBD-E-W-S- or equal
Specify :________________________2 __________
57 LTG-02 Lighting Control Keypad - for control of
dimming 120V soffit can lights
Crestron- or equal
Specify :______________
C2N-CBD-E-W-S- or equal
Specify :________________________2 __________
58 Lighting Control Interface Processor and
enclosure, for use with Cameo/Cresnet
devices and 120/277V dimming/switching
modules
Crestron- or equal
Specify:______________
GLNET-CN- or equal
Specify :________________________1 __________
59 Lighting Control Module, for use with
GLNET-CN and switched 277V lighting
loads
Crestron- or equal
Specify :______________
GL-EXP-SW-CN- or equal
Specify :________________________2 __________
60 Lighting Control Module, for use with
GLNET-CN and dimable 120V lighting
loads
Crestron- or equal
Specify :______________
GL-EXP-DIMU-CN- or equal
Specify :________________________2 __________
Appendix A
27 41 20 - CITY OF UKIAH COUNCIL CHAMBERS: BID ALTERNATE 'A'
Miscellaneous hardware, accessories, connectors, cabling, terminal blocks, etc., necessary to insure a complete
and operating system.
Set audiovisual systems schematic drawings, shall be printed, laminated & stored in pocket of audiovisual
equipment rack.
SECTION 27 41 20 - APPENDIX 'A'
AUDIOVISUAL SYSTEMS
PAGE 4 of 4
Page 233 of 390
P-2703 City of Ukiah California
Council Chambers AV Replacement
Item #Drawing/ Appendix
Ref.Product Manuf.Model #Unit Qty Ext.
1 CP-02 Control Button Panel & 3-series Processor,
wall-mounted 3-gang type, with serial port
and relay/analog/digital I/O, IP network
interface
Crestron - or equal
Specify:______________
MPC3-302-W - or equal
Specify:______________
__________1 __________
2 IPS-03 Ethernet Switch - Rack-mounted 8-port
PoE+/PoE++,L2/L3 managed switch, 60W
power budget
Cisco - or equal
Specify:______________
SG350-10P - or equal
Specify :________________________1 __________
3 CPC-02 Owner Furnished PC Computer - Small-
form-factor (Intel NUC), with undertable
mounting bracket, for use on-
network/credentialled access and UC/MS
Teams - Located under Secretary's dais
position
By Owner By Owner OFE/ETR/
FBO
1 OFE/ETR/
FBO
4 FPD-04 Flat panel display - 75" LCD, LED backlit,
350nit output, RS-232/IP control
NEC - or equal
Specify:
C751Q - or equal
Specify:
__________1 __________
5 FPD-04 Flat panel display mount - Large fixed wall
mount - for 75" flat panel display
Chief/LegrandAV - or equal
Specify:
LTMU - or equal
Specify :__________1 __________
6 HDRX-01 HD-Base-T & HDMI Auto-swticher: HDBT
and local HDMI input, HDMI output, with
network control & I/O
Crestron - or equal
Specify:______________
HD-RX-201-C-E - or equal
Specify:______________
__________1 __________
7 HDTX-01 HD-Base-T Transmitter, undertable mount Crestron - or equal
Specify:
HD-TX-101-C-E - or equal
Specify:
__________1 __________
8 CAM-03 HD Fixed Zoom Camera - Display mounted
wide-angle lens, with matching remote
UTPx2 receiver unit - output HDMI, USB,
H.264/RTSP
Vaddio/LegrandAV - or equal
Specify:______________
WideSHOT SE QUSB
Systems - or equal
Specify:______________
__________1 __________
9 WPA-01 Wireless Presentation Appliance - 1 HDMI
input, 2 HDMI output, dual-NIC & local AP -
Include 3-years mfgr support in quote
Mersive - or equal
Specify:______________
Solstice POD Gen3
+Solstice Subscription (3
yrs) - or equal
Specify:
__________1 __________
10 REC-01 Recording/Streaming Appliance - Rack-
mount, 2-HDMI input, dual-image/PIP
support, H.264/265 streaming, recording to
SD card, RTMP/RTSP support for client
CivicPlus software & cloud services
Epiphan - or equal
Specify:______________
Pearl Mini - or equal
Specify :______________
__________1 __________
11 HDA-02 HDMI Distribution Amplifier - 1x2
HDMI2.0b/HDCP2.2; with rack-mount kit
Extron - or equal
Specify:______________
DA2 HD 4k PLUS w/ RSU
126 & ZipClip50 for
undertable mounting - or
equal
Specify:
__________2 __________
12 UCC-01 Unified Conferencing Hub - 1-HDMI IN/2-
HDMI Out, with USB2.0/3.0 connectivity for
cameras, user PC, Bluetooth dialing, IP
network control/mgmt.
Biamp - or equal
Specify:______________
Devio SCR-25 - or equal
Specify:______________
__________1 __________
13 MIC-05 Ceiling Surface-mounted Beamforming
Microphones - Up to 4 tracking beam
elements per mic, with single daisy-chain
connectivity for 2-mics
Biamp - or equal
Specify:______________
Devio DCM-1 - or equal
Specify:________________________2 __________
14 FPD-04 Side-bar Speakers - 2-way custom sized
units to mount to display sides. Provide
VESA mounting bracket to pair to display
Innovox - or equal
Specify:______________
FS-V2 (Pair) - or equal
Specify:______________
__________1 __________
15 TB-01 Flush Mount In-table Captive Cable and
Power Box - (1) HDMI captive cables;
Duplex 120V power + USB-C & USB-A
power; with bracket kit & undertable cable
cover kit
Extron - or equal
Specify:______________
Cable Cubby 1202 (70-
1184-02, w/60-1782-01, (2)
26-663-04, 70-1040-03, 70-
1080-02) - or equal
Specify:
__________1 __________
16 TTB-01/03 Video Connector Adaptor Ring Set - (1)
DisplayPort male to HDMI female, (1) Mini-
DisplayPort male to HDMI female, (1) Mini-
HDMI "C" male to HDMI female, and (1)
Micro-HDMI "D" to HDMI female on
securing clamp 'ring' cable
Liberty AV - or equal
Specify:______________
DL-AR2 - or equal
Specify:________________________1 __________
17 __________LOT __________
18 __________LOT __________
MISCELLANEOUS HARDWARE
Miscellaneous hardware, accessories, connectors, cabling, terminal blocks, etc., necessary to insure a
complete and operating system.
Set audiovisual systems schematic drawings, shall be printed, laminated & stored in pocket of
audiovisual equipment rack.
AUDIO
Appendix A
27 41 30 - CITY OF UKIAH CONFERENCE ROOM 3: AUDIOVISUAL SYSTEMS
CONTROL
DISPLAY & VIDEO
SECTION 27 41 30 - APPENDIX 'A'
AUDIOVISUAL SYSTEMS
PAGE 1 of 1
Page 234 of 390
P-2703 City of Ukiah California
Council Chambers AV Replacement
Item #Drawing/ Appendix
Ref.Product Manuf.Model #Unit Qty Ext.
1 CP-02 Control Button Panel & 3-series Processor,
wall-mounted 3-gang type, with serial port
and relay/analog/digital I/O, IP network
interface
Crestron - or equal
Specify:______________
MPC3-302-W - or equal
Specify:______________
__________1 __________
2 IPS-03 Ethernet Switch - Rack-mounted 8-port
PoE+/PoE++,L2/L3 managed switch, 60W
power budget
Cisco - or equal
Specify:______________
SG350-10P - or equal
Specify:________________________1 __________
3 CPC-02 Owner Furnished PC Computer - Small-
form-factor (Intel NUC), with undertable
mounting bracket, for use on-
network/credentialled access and UC/MS
Teams - Located under Secretary's dais
position
By Owner By Owner OFE/ETR/
FBO
1 OFE/ETR/
FBO
4 FPD-05 Flat panel display - 65" LCD, LED backlit,
350nit output, RS-232/IP control
NEC - or equal
Specify:
C651Q - or equal
Specify:
__________1 __________
5 FPD-05 Flat panel display mount - Large fixed wall
mount - for 75" flat panel display
Chief/LegrandAV - or equal
Specify:______________
LTMU - or equal
Specify:________________________1 __________
6 HDRX-01 HD-Base-T & HDMI Auto-swticher: HDBT
and local HDMI input, HDMI output, with
network control & I/O
Crestron - or equal
Specify:______________
HD-RX-201-C-E - or equal
Specify:______________
__________1 __________
7 HDTX-01 HD-Base-T Transmitter, undertable mount Crestron - or equal
Specify:
HD-TX-101-C-E - or equal
Specify:
__________1 __________
8 CAM-03 HD Fixed Zoom Camera - Display mounted
wide-angle lens, with matching remote
UTPx2 receiver unit - output HDMI, USB,
H.264/RTSP
Vaddio/LegrandAV - or
equal
Specify:______________
WideSHOT SE QUSB
Systems - or equal
Specify:______________
__________1 __________
9 WPA-01 Wireless Presentation Appliance - 1 HDMI
input, 2 HDMI output, dual-NIC & local AP -
Include 3-years mfgr support in quote
Mersive - or equal
Specify:______________
Solstice POD Gen3
+Solstice Subscription (3
yrs) - or equal
Specify:
__________1 __________
10 REC-01 Recording/Streaming Appliance - Rack-
mount, 2-HDMI input, dual-image/PIP
support, H.264/265 streaming, recording to
SD card, RTMP/RTSP support for client
CivicPlus software & cloud services
Epiphan - or equal
Specify:______________
Pearl Mini - or equal
Specify:________________________1 __________
11 HDA-02 HDMI Distribution Amplifier - 1x2
HDMI2.0b/HDCP2.2; with rack-mount kit
Extron - or equal
Specify:______________
DA2 HD 4k PLUS w/ RSU
126 & ZipClip50 for
undertable mounting - or
equal
Specify:
__________2 __________
12 UCC-01 Unified Conferencing Hub - 1-HDMI IN/2-
HDMI Out, with USB2.0/3.0 connectivity for
cameras, user PC, Bluetooth dialing, IP
network control/mgmt.
Biamp - or equal
Specify:______________
Devio SCR-25 - or equal
Specify:______________
__________1 __________
13 MIC-05 Ceiling Surface-mounted Beamforming
Microphones - Up to 4 tracking beam
elements per mic, with single daisy-chain
connectivity for 2-mics
Biamp - or equal
Specify:______________
Devio DCM-1 - or equal
Specify:________________________1 __________
14 FPD-05 Side-bar Speakers - 2-way custom sized
units to mount to display sides. Provide
VESA mounting bracket to pair to display
Innovox - or equal
Specify:______________
FS-V2 (Pair) - or equal
Specify:______________
__________1 __________
15 TB-01 Flush Mount In-table Captive Cable and
Power Box - (1) HDMI captive cables;
Duplex 120V power + USB-C & USB-A
power; with bracket kit & undertable cable
cover kit
Extron - or equal
Specify:______________
Cable Cubby 1202 (70-
1184-02, w/60-1782-01, (2)
26-663-04, 70-1040-03, 70-
1080-02) - or equal
Specify:______________
__________1 __________
16 TTB-01/03 Video Connector Adaptor Ring Set - (1)
DisplayPort male to HDMI female, (1) Mini-
DisplayPort male to HDMI female, (1) Mini-
HDMI "C" male to HDMI female, and (1)
Micro-HDMI "D" to HDMI female on
securing clamp 'ring' cable
Liberty AV - or equal
Specify:______________
DL-AR2 - or equal
Specify:______________
__________1 __________
17 __________LOT __________
18 __________LOT __________
AUDIO
MISCELLANEOUS HARDWARE
Miscellaneous hardware, accessories, connectors, cabling, terminal blocks, etc., necessary to insure
a complete and operating system.
Set audiovisual systems schematic drawings, shall be printed, laminated & stored in pocket of
audiovisual equipment rack.
Appendix A
27 41 35 - CITY OF UKIAH CONFERENCE ROOM 5: AUDIOVISUAL SYSTEMS
CONTROL
DISPLAY & VIDEO
SECTION 27 41 35 - APPENDIX 'A'
AUDIOVISUAL SYSTEMS
PAGE 1 of 1
Page 235 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 1 of 31
SECTION 274100 – COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
PART 1 - PART 1 - GENERAL INFORMATION
1.1 SCOPE OF WORK – GENERAL
A. This project encompasses the replacement of the audiovisual systems in the existing office
conference rooms and City Council chambers of the Civic Center building of The City of Ukiah in
Mendocino County, California.
B. Spaces in Scope
1.Locations within the scope of this RFP include the following spaces as outlined in Related Work
Sections:
a.Council Chambers – An approximately 55’ deep by 34’ wide legislative chamber used for
meetings of the City Council, as well as meetings of executive staff and management, as well
as public hearings and community events. The Chambers include a 7-person dais, a
speaking podium, as well as seating for the City Clerk, and city employees in front of and
adjacent to the dais. There is fixed audience seating for up to 120 members of the public, as
well as a divisible door that separates the Chambers from the Civic Center Lobby. The
Council Chambers includes these ancillary spaces:
b.Lobby – An approximately 44’ wide by 28’ deep room, with an operable wall separating
the Council Chambers space. AV in the space is limited to a pair of zoned ceiling s peakers
to allow this space to host overflow audiences from the Chambers, as well as provide audio
to late-arrival members of the public. This overflow audio zone also includes a switch
selectable outdoor speaker subzone that provides audio to the exterior entry area. These
existing zones will be preserved and reused in the new replacement systems – with the
existing outdoor zone to be reassigned to new ceiling speakers in the restrooms at the entry,
with the outdoor speakers being abandoned in-place.
c.AV Rack Room & CATV POP – An approximately 8’ wide by 6’ deep room housing the
existing AV equipment rack, as well as a small IDF for the IT network and a POP
demarcation for the local community access provider (Comcast). Work in this space is to
include:
i.Replacement of existing AV equipment rack and equipment, including removal of
existing rack and supporting hardware and replacement with an existing OFE 19”x
29”D x 42RU high equipment rack, providing necessary bland and filler panels and
accessories, and integration into the existing infrastructure and power.
ii.Reinstallation and integration of new AV systems to provide audio and video feeds to
the Comcast POP and associated SDI-to-fiber interfaces to the demarcation point on
the wall (see drawings).
d.Conference Room 3 – A medium sized conference and committee meeting room of
approximately 20 seats. Work in this space is to include replacement of the existing display
unit, as well as addition of wireless presentation, web-conferencing, and capture/streaming of
content to the city network and city’s web-based recordkeeping and recording services
(CivicPlus).
e.Conference Room 5 – A small conference room in the city facilities outbuilding just to the
west of the main Civic Center. This space is to receive a similar Scope to Conference Room
3, but with a smaller display and single microphone
f.Further Scope within the Council Chambers includes:
i.Replacement of display systems as described in paragraph ‘a’ above.
APPENDIX B - TECHNICAL DETAILS
Page 236 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 2 of 31
ii. Replacement of all audio systems and cabling, including microphones, loudspeakers
and associated hardware. Included in the Scope will be the removal of ALL existing
audiovisual systems owned by the City. Existing ceiling speakers will be assessed
by the Contractor and retained and reused with their existing amplification, if found to
be serviceable and performing well.
iii. Replacement of all video input and transport systems and cabling.
iv. Replacement of any control systems and cabling.
v. Addition of systems to allow:
a) Recording and streaming of meetings
b) Support of unified conferencing and web-conferencing
c) Delegate-style conferencing system, with dais and podium microphone/speaker
units and moderator control from the City Clerk’s position
d) Input of computer signals from the podium, each seat at the dais, as well as two
inputs from the Secretary’s position at the dais – both a laptop and fixed PC.
e) Capture of audio from the audience, as well as from any tabled meetings taking
place in the general gallery of the space
f) Wireless microphones for support of presenters , city employees, and meeting
attendees
g) Comprehensive unified control of room systems using a touchpanel at the
Secretary’s position at the Dais, as well as any Owner -furnished PC computer
running a touchpanel emulation – using Wi-Fi or remote support
h) Wireless presentation of content in the room using gue st Wi-Fi, from any device
running common operating systems
i) Integration of AV feeds to and SDI-to-Fiber conversion system owned by the local
community access CATV provider (Comcast)
j) Integration of AV recorder and streaming interface to City’s cloud-services based
recordkeeping platform (CivicPlus) using RTMP/RTSP protocols.
1.2 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including Owner’s Cover Documents, Sample
Contract, etc…, apply to this Section.
B. Equipment Schedules, as referenced in the drawings and specification Appendices.
C. Related Sections under this Section, describing the audiovisual systems to be installed in each
space-type, including details for function, operation, and programming.
1. 27 41 20 – Council Chambers Audiovisual Systems
2. 27 41 30 – Conference Room 3 Audiovisual Systems
3. 27 41 35 – Conference Room 5 Audiovisual Systems
1.3 QUALIFICATIONS OF BIDDERS
A. The Bidder shall be a firm with at least ten years of experience in the design, engineering,
fabrication, assembly, and installation of audiovisual systems of similar magnitude and quality as
specified for the subject job, and shall submit documentation to this effect with the bid return.
B. Each bidder shall have at least one project manager or engineering staff employee on this pro ject
possessing a certificate, from AVIXA (CTS-D) or another recognized organization or institution
providing formal training in audiovisual systems design or engineering. Proof of this shall be
supplied with bid.
Page 237 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 3 of 31
C. Each bidder shall have at least one supervisory employee on this project possessing a certificate,
from AVIXA (CTS-I) or another recognized organization or institution providing formal training in
audiovisual systems installation and commissioning. Proof of this shall be supplied with bid.
D. All employees of the contractor to install this system must be competent technicians who are
experienced in the installation and interconnection of professional audiovisual systems (AVIXA CTS
and relevant manufacturer certifications (i.e. – Crestron DMC).
E. All lead engineering and project management is to be handled by a qualified, full-time employee of
the audiovisual contractor. No outsourcing or sub-contracting of this phase will be accepted.
Engineering may be conducted in concert with a selected loudspeaker systems manufacturer, who
may provide supplementary systems evaluation, modelling, design, or systems engineering to
supplement the Contractor, under the supervision of the Contractor’s project manager or engineer.
F. Each bidder shall maintain an adequately equipped and staffed service department and shall
regularly provide service for systems similar to this design. This shall include an office staffed with
personnel at all times, Monday through Friday, between the hours of 8:30 AM and 8:30 PM Pacific
Time (adjusted to daylight or savings time – per that time of the year). Answering services, cellular
telephones, pager numbers and call forwarding systems are helpful but do not meet nor comply
with the intent of this specification.
G. The bidder shall include with their proposal a schedule of support, including response times for
on- site service, from the time a service-call is placed by the Owner, to the time service personnel
will be on-site to address the Owner’s service need.
H. The bidder shall note whether phone or on-site responses will be provided directly by on-staff
personnel or if they will be relying upon a 3rd-party which will be sub-contracted to supply such
service(s). The bidder shall provide the name and location of such a 3rd party within their response.
I. Each bidder shall be currently authorized by the manufacturer of the major components of the
system to sell their products and initiate warranty service on the same items. Major components of
the system shall include, but not be limited to, data/video projectors and displays; video distribution,
processing and switching equipment; audio distribution and processing equipment; power
amplifiers, speakers, etc. Proof of this may be requested during the bidding process. Proof of
franchise shall be in the form of a letter from the appropriate manufacturer addressed to the
Owner’s Representative stating that the contractor is currently authorized to sell their products.
Letters from the sales representative (rep) shall not be accepted as proof.
1.4 DEFINITIONS OF TERMS
A. The term “Owner” shall refer to City of Ukiah, Mendocino County, California.
B. The term “Architect” shall refer to City of Ukiah designated Representative acting in the role of
Project Manager for the City.
C. The term “Consultant” shall refer to ABD Engineering & Design, also referred to as Engineer in the
Owner’s Cover Documents.
D. The term “Bidder” shall refer to a firm submitting a n RFP response to this specification and the
Governing Documents provided as part of this RFP.
E. The term “Contractor” or “Integrator” shall refer to the Systems Contractor/Integrator who has been
awarded the contract for the subject job and who has responsibility for performance of the work
specified herein.
F. The acronym “NIC” shall refer to material and work which is “Not in Contr act” and for which the
Contractor is not responsible except as otherwise detailed herein.
G. The term “OFE” shall refer to “Owner Furnished Equipment”, which will be provided by the Owner.
The Contractor shall be responsible for removing this equipment from the Owner’s premises as
appropriate and re-installing and integrating this equipment in good working order as detailed
herein.
Page 238 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 4 of 31
H. The term “shall” is mandatory; the term “will” is informative; the term “should” is Permissive.
I. The term “Work” describes all construction type processes. Including but not limited to, labor,
equipment, materials and services specified herein.
J. The term “Furnish” means to purchase and deliver to the project onsite location, with every
necessary accessory and support, all as part of the Work. Purchasing shall include payment of all
sales taxes and other surcharges as may be required to assure that purchased items are free of all
liens, claims, or encumbrances.
K. “Install” – To perform every operation necessary to establish secure mounting and correct
operation at the proper location in the project, all as part of the Work.
L. The term “provide” means furnish and install.
M. The term “commissioning” refers to the process by which equipment or systems (which are
installed, complete or near completion) are tested to verify if they function according to their design
objectives or specifications.
N. The term “Project” is the installation of Audiovisual Systems in the facility or facilities described
within this specification.
O. The term “Drawings” refers to Audiovisual systems drawings and any details, risers, etc.
associated with the work.
P. Certain words or phrases as used in the Drawings or Specifications for the Work may have
multiple meanings such as those specified in codes or other industry standards . The words or
phrases mentioned below shall be understood to have the following specified meanings with regard
to the audiovisual systems described herein:
1. “Circuit” – Any design of circuitry.
2. “Circuitry” – Any type of Work which consists of wires/cables, raceways, specialty wiring method
assemblies complete with associated junction boxes, pull boxes, outlet boxes, joints, couplings,
splices, and connections except where limited to a lesser meaning by specific description.
3. “Concealed” (as applied to circuitry) – Covered completely by building materials, except for
penetrations (by boxes and fittings) to a level flush with the surface as necessitated by functional
or specified accessibility requirements.
4. “EC” – Electrical Contractor, in the context of either a sub-contractor to the Bidder or an
independent Contractor.
5. “Exposed” (as applied to circuitry) – Not covered in any way by building materials.
6. “Normal Work Conditions” – Locations within building confines that are not damp, wet, or
hazardous and that are not used for air handling.
7. “Patch Panel” – A System of terminal blocks, patch cords, and backboards that facilitate
administration of cross-connecting cables.
8. “Raceway” – Any pipe, duct, extended enclosure, or conduit (as specified for a particular
System) which is used to contain wires, and which is of such nature as to require that the wires
be installed by a “pulling in” procedure.
9. “Riser” – Shall refer to the portion of the installation that transmits between building floors (or
between audiovisual Systems rooms), also referred to as “Backbone Cabling.”
10. “audiovisual Closet” – The enclosed area or room specifically designated for the routing,
termination, and/or cross connecting of audiovisual Systems cable (i.e. riser cable) to other
Audio- Visual Systems cable and/or equipment.
11. “AV Systems Control Room” and/or “AV Systems Headend” – The enclosed area or room
specifically designated for the routing, termination, and/or cross connecting of audiovisual
System cable (i.e. riser cable) to other Audio-Visual System cable, and/or equipment, and racks.
12. “AV System(s)” – audiovisual System(s), includes all components contained herein that work in
conjunction to create and completely integrated and fully functioning system as described within
the Drawings and Specifications.
13. “audiovisual Systems Wiring” – see “Circuitry.”
14. “audiovisual Systems Work” – See “Work.”
Page 239 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 5 of 31
15. “Standard” (as applied to wiring devices) – Not of a separately designated individual type.
16. “System” – See “AV Systems.”
17. “Wiring” – see “Circuitry.”
18. “AVC” – audiovisual Systems Contractor.
19. Where the term “Conduit” is used without specific reference to type, it shall be understood to
mean “raceway.”
1.5 INFORMATION TO BE SUBMITTED WITH BID RETURN
A. Bidder to provide as part of their bid submittal - the following breakdown of submitted Costs for
evaluation, as detailed in Appendix A:
1. Equipment Costs
a. The bid return shall include detailed lists of all equipment to be supplied. Each piece of
equipment shall be individually priced and carried over for multiples to a total. Equipment that
is contained in lots or groupings, such as wiring, connectors, or loose general hardware shall
be provided in a lump-sum lot and noted as “lot” and noted appropriately in the proposal.
Totals for each area are to be transferred to the Master Pricing Table provided for in
Appendix A. The Master Pricing Table will be used to determine the low bidder.
2. Non-Equipment Costs
a. Non-equipment costs shall be furnished separately with the equipment costs within the
Master Pricing Table provided for in Appendix A. These non- equipment costs shall be
detailed for each of the following categories:
i. Engineering: Including all required designs, drawings, run sheets, instruction
manuals, etc.
ii. Pre-installation: Including all fabrication, modification, assembly, rack wiring, etc.,
performed on the Contractor’s premises.
iii. Installation: Including all on-site installation and wiring, coordination and
supervision, etc. performed on the Owner’s premises.
iv. Commissioning: Including all final measurements and testing, performance
verification, systems tuning and adjustments, and documentation of said
measurements and testing, along with a final report summarizing the results of the
commissioning. Include costs for on-site checkout/inspective by the Owner and
Consultant, as well as costs for Owner Training sessions, as outlined further in this
specification document.
v. General and Administrative: Including all ‘G & A’ expenses, shipping, insurance,
and guarantees.
vi. Taxes (if applicable).
3. Subcontractor Costs: Upon award of Contract - at the request of the Owner, Contractor shall
provide cost schedule for each subcontractor to be used by the Prime Contractor, broken down
by the same general order as items ‘A.2.a’ above.
B. Submitted with the bid documents, the Bidder is to provide as part of their submittal, the following
General Information to include:
1. The number of years in business.
2. Resumes of key personnel. Resumes must reflect skills relating to audio, video & display
systems, systems and hardware rigging, teleconferencing (audio and video), integrated control
systems, software platforms, programming, project management, etc.
3. Locations of all currently staffed and operational offices complete with the number of technical
support personnel in each office.
4. Project References (minimum of three (3) required for work of similar magnitude or character)
a. These should include:
Page 240 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 6 of 31
i. End user contact name, with current title and position, telephone number and e-mail
address.
ii. Functional description of the project.
iii. Project scope and approximate dollar amount (single projects should be equivalent
to the size of this project, not accumulative work of a single client).
iv. Timeline of project and final completion date.
v. All projects identified must be verifiable and have been completed within the
last three years (36 months).
5. List of products for which the firm is a direct dealer, including the duration of the dealership and
the extent of any factory training. This list should include, but not be limited to:
a. Large screen display systems, both projection and display-type, including but not limited to
direct-view indoor/outdoor LED, LCD/LED/OLED, DLP/DMD and LCoS.
b. Specialized display systems (as applicable).
c. Video networked/IP switching/routing, scaling, conversion, and distribution systems.
d. Large-venue loudspeaker systems, such as long-throw and line-array systems, and high-
power amplifiers and amplification.
e. Computer processor-controlled audio systems including but not limited to audio digital
signal processors and IP distribution systems.
f. Integrated control systems.
g. Video and Audio Broadcast systems – production & transport.
h. IT and IP networking equipment as used in audiovisual systems
implementations/installations.
6. List of technical products that the firm has installed and serviced but are not a direc t dealer for.
C. Schedule of Implementation: Upon award of Contract, the following shall be provided by the
Contractor:
1. Contractor to verify the project schedule and confirm that they will comply with the project
schedule and deliver a complete audiovisual system within the specified time frame.
2. Contractor may shall indicate their acceptance of the project schedule by submitting a
scheduling plan, indicating the various pertinent terminal dates after award of contract for
completion of design, pre-installation work, on-site installation work, and testing and acceptance
on a “per phase” basis.
3. At a minimum the schedule should include the following information:
a. Number of days required for submission of the following documents from receipt of notice
to proceed:
i. Product submittals, with any significant lead-times noted
ii. Engineered submittals
iii. Touchpanel GUI and other UI submittals
iv. Spreadsheet of network connected device MAC address, device names/models, and
IP address request tables to coordinate with Owner’s IT management for
implementation of network services. Table shall include information regarding any
class-of-service, QoS or IGMP version and settings needed.
v. Commissioning test documents and reports
b. Benchmark dates of other Subcontractor or Owner-furnished/Owner-installed items, and
Page 241 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 7 of 31
days to completion of tasks associated with those benchmarks.
D. If provided, the Bidder shall review attached cover documents and schedule for additional
information.
E. Alternate Equipment
1. All bids shall be submitted on the basis of the specified equipment as outlined in the Appendix
‘A’ sections of this specification. The Bidder may propose alternate equipment, or equipment
they feel meets the intent of “equal” or “equivalent” as described below in Subsection ‘E’. If
proposing an “equal” or “equivalent”, the bidder shall provide the alternate manufacturer’s name
and part numbers in the areas provided for in Appendix A.
2. Proposals for alternate equipment will receive careful and equitable consideration if the
differences do not depart from the overall intent of the design and operation of the system, are in
the best interests of the Owner, and are equal in durability and usability.
3. All such proposals for alternate equipment shall be accompanied by full technical information,
“cuts” and specifications for the equipment so proposed. The Bidder shall identify the
substantive differences between the alternate and the specified equipment.
F. Sub-Contract Information
1. If the Bidder proposes to sub-contract portions of the work – such sub-contractors shall be
identified in accordance with the Owner’s Front-End Documents for Sub-Contractor
requirements. The work as performed by a sub-contractor shall be considered as part of the
contractor’s responsibility with that work as part of the contractor’s s tatement. Any contract
arising as a direct result of these proceedings shall be binding on the successful bidder and the
terms of said contract shall be submitted with the bid return.
1.6 WARRANTY STATEMENT
A. To maintain certain manufacturer’s warranties, said equipment must be installed, aligned and
serviced by those installers authorized by said manufacturer to perform those duties. If the
contractor is not authorized, by said manufacturer, it is his sole responsibility to make the
appropriate arrangements and bear all cost and consequences thereof.
B. The Bidder shall include a statement of warranty on the entire system and on the individual pieces
of equipment. The system warranty shall be for a minimum of 365 days from the date of
commissioning by the Owner and Consultant (refer to 3.5 for “Commissioning Test” requirements).
This warranty shall obligate the Contractor to provide all equipment, material, and labor at no
charge to the Owner, during the warranty period, in the event of a system or equipment
malfunction.
C. In cases where the manufacturer’s warranty period is greater than twelve months, the contractor is
required to honor that warranty for the full extent of the manufacturer’s warranty period. This shall
exclude any labor costs incurred by the contractor removing and re-installing the defective items
after the system warranty expiration.
D. In cases where the manufacturer’s warranty period is less than 12 months, the contractor is
liable for defects in the item up to-but not exceeding-the first twelve-month period on any
contractor provided items.
E. The system warranty shall include a minimum of four (4) preventative maintenance visits over the
systems warranty time period, to perform operation checks of the equipment, re-measure systems
performance and re-tune the system’s DSP settings, equalization, dynamics, etc... for optimum
performance, as well as check the projectors, screens, display and signal
transport/switching/matrixing systems, network hardware, firmware and software, as well as
respective mounting and rigging hardware for safety and integrity.
F. All manufacturers’ equipment warranties shall be activated in the Owner’s name and shall
commence on the date that commissioning is completed. In the case of Contractor -modified
equipment, the manufacturer’s warranty is normally voided. In such cases, the Contractor shall
provide the Owner with a warranty equivalent to that of the original manufacturer.
Page 242 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 8 of 31
G. In the event of malfunction or failure of any audiovisual equipment provided by the AV integrator,
the integrator is responsible for providing replacement of faulty equipment, or providing “loaner”
equipment. In the event that “loaner” equipment is provided, said equipment shall meet or exceed
the original equipment specifications until the original equipment can be replaced.
H. In Cases where the contractor is providing and installing audiovisual equipment and/or hardware
to be integrated with equipment furnished by others, it shall be the responsibility of the contractor to
warrant their equipment as described herein; unless said equipment shows misuse and or abuse by
others during re-installation of, or connection of equipment by others.
I. Telephone Support
1. The Audiovisual Contractor shall respond via telephone within two (2) hours to any request for
service. This first contact should outline the nature of the problem or functional anomaly. The AV
Contractor shall make available an individual knowledgeable with the installed system, and who
can address specific system issues described by the system operators.
J. On-Site Support
1. The system warranty shall be an “on-site” warranty, with a twenty-four (24) hour response time.
Telephone support shall be available between normal business hours, Monday through Friday. If
a 3rd-part sub-Contractor is to be used, the Bidder shall include this information, with firm name,
location and primary contact information included.
1.7 PREVENTATIVE MAINTENANCE & SERVICE CONTRACT
A. In addition to the preventative maintenance described under 1.6 Warranty and other paragraphs,
the Bidder shall offer a separate annual preventative maintenance contract by pricing for five (5)
years on a year-to- year basis. This preventative maintenance contract shall cover all installed
systems and include a minimum of three (3) visits per year, at regular intervals to perform operation
checks of the equipment, clean filters, check drivers, to inspect and perform safety checks on
rigging, lubricate moving parts as recommended by the respective manufacturers and to adjust and
align rigging and loudspeaker units or arrays to maintain performance as set initially. The
preventative maintenance contract is an option for the Owner to exercise immediately after
expiration of the warranty period. The Bidder shall include the pricing for the first (1) year in the
Base Bid, with each subsequent year priced as Add Alternates #2 through #5.
B. Upon award of Contract, The Contractor shall also submit separate costs for other emergency “on-
call” service visits and an “in-shop” hourly rate for repair and maintenance work.
C. The costs for this service contract shall not be commingled with the costs for the systems base
bid. The lowest bid based upon base-bid will also take into account the proposed costs of the first
year preventative maintenance Contract/Warranty proposed.
1.8 SUB-CONTRACT
A. Refer to Owner’s Front-End Documents for sub-Contractor requirements, including participation
requirements and limitations, including State requirements.
B. If the Bidder proposes to sub-contract the installation and wiring, or other portions of the work, the
Bidder shall provide direct supervision of the sub-contracted work.
C. Because of the complexity of the systems, the supervision of such sub-contracted work cannot be
intermittent, but shall be continuous during the installation.
D. It is the sole responsibility of the bidder to research and provide any and all necessary sub -
contracts pricing for union labor that cannot be provided from within its own organization.
Information related to this must be provided with this bid return.
E. If it is the intention of the Bidder to “team” with one or more other AV Contractors, then this must
be clearly identified in the bid return. The Contractor returning the bid will be considered as the
prime in respect of this, and will hold full responsibility for the performance of the members of their
team, including themselves and all other sub-contractors engaged in the performance of this
Page 243 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 9 of 31
contract.
1.9 INVESTIGATION OF CONTRACTUAL AND SCHEDULING QUESTIONS
A. It shall be the responsibility of the Bidder to investigate all potential contract, union, and
scheduling questions, and to guarantee compliance with all requirements and regulations in effect
on the job site. Any potential problems in this respect shall be identified in the bid return. The
contractor shall comply with all local state and federal regulations.
B. A Pre-Bid Meeting will be scheduled by the Owner to provide access to the site for investigation by
Bidders. The Consultant will be available via phone during this meeting to address any Bidder
questions. Refer to Owner’s Cover Documents for details regarding the Pre-Bid meeting.
1.10 CONTRACTOR’S GENERAL RESPONSIBILITIES
A. The Contractor shall be responsible for delivering a turnkey system to the Owner.
B. The Contractor shall furnish all equipment and materials, whether specifically mentioned herein or
not, to ensure a complete and operating system. The NIC and OFE equipment and materials are
specifically exempted from this requirement.
C. The Contractor shall generate all shop drawings and information for the complete installation and
wiring of the system. The Contractor shall provide (or sub-contractor for) the on-site installation and
wiring, and shall provide on-going supervision and coordination during the implementation phase.
D. The Contractor shall be responsible for the initial adjustment of the systems as herein prescribed
and shall provide all test equipment for the system checkout and commissioning. Contractor shall
provide on-the- job training in the operation and maintenance of the systems for personnel
designated by the Owner.
E. The Contractor shall coordinate and submit to all site policies and adhere to all site safety
procedures put in place by the Owner.
F. The Contractor shall attend all construction meetings as required by the Owner.
G. The Contractor shall perform an RF Spectrum Analysis Survey identifying all available
frequencies that may be required by any wireless equipment under this specification such that
appropriate frequency allocations may be identified for the purpose of purchasing corresponding
transmitters and receivers. The Contractor shall be responsible for the validity of the survey and
any subsequent equipment substitution that may result even if such equipment has been previously
accepted by submittal.
1.11 PROJECT MANAGEMENT
A. The Contractor shall provide a Project Manager to oversee and coordinate all activities on the
Project
B. Project Manager’s Duties and Responsibilities:
1. The Contractor shall provide to the Owner, as a part of the Pre-Construction Submittals, the
name of the Project Manager that will provide all duties and responsibilities as specified in this
Section, during the term of the project.
2. The Project Manager onsite shall maintain the ability of making all managerial decisions on
behalf of the Contractor on a day-to-day basis, and shall retain the authority of accepting n otices
of deduction, inspection reports, payment schedules and any other project related
correspondence on behalf of the Owner.
3. The Project Manager shall attend project meetings as required, during which time all System
related issues are discussed, scheduled, confirmed, and/or resolved.
4. The Project Manager shall be available during normal business hours (8:00 am to 5:00 pm) by
telephone during the term of the project.
a. After normal business hours, the Project Manager shall be available within four (4) hours
Page 244 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 10 of 31
(5:00 pm to 9:00 pm) by email during the term of the project for urgent matters.
b. In the event that the Project Manager is not available within the allotted time frame, the
Contractor may designate additional staff to temporarily act as the Project Manager for all
correspondence with the Owner.
c. The Contractor shall ensure that any individual temporarily assuming the duties of the
Project Manager is at equal or higher level in the Contractor’s managerial chain of command.
5. Upon notification by the Owner, of any project related installation issue, or issue that may
contradict the Specifications as stated herein, the Project Manager shall respond to such issue
verbally and/or in writing within an eight (8) hour period.
a. Responses to such issues as stated above shall include a clear understanding of the
issue, along with a tentative plan of action, reflecting milestones and/or deadlines to resolve
the issue.
b. Where appropriate, based on the overall importance of the project issue, the Project
Manager shall follow-up their initial response with a written response to the issue within 24
hours of the Project Manager being notified of the identification of the issue.
6. Prior to the initiation of the Work, the Project Manager shall submit a schedule reflecting key
milestones of the Work, including but not limited to the following
a. Bid award
b. Kick-off meeting
c. Plan submittal
d. Pre-Construction submittal
e. Ordering, delivery, and installation of System equipment
f. Field equipment delivery
g. Project management schedule
h. Payment schedule
i. Installation cut-over date(s), including provisioning of temporary equipment to allow for
regularly scheduled Council or Planning Commission meeting(s), as coordinated with the
Owner
j. Installation completion date
k. System training
l. Delivery of As-Built documentation
m. Delivery of Operations & Maintenance Manuals
n. Commissioning
o. Acceptance of System
7. The Project Manager shall update the schedule on a weekly basis to reflect the status of each
key milestone as the Work progresses.
8. As the System installation progresses, the Project Manager shall be capable of discussing
any/or all of the above-mentioned items at the request of the Owner, and shall address each
item, as it relates to the current status of the Work.
9. If for any reason, the contractor shall become unable to meet the milestones outlined in their
project schedule, the Project Manager shall notify the Consultant, Architect, and Owner’s related
laborers or Contractors associated with related work, so as minimize delays in other Work.
1.12 REFERENCE TO ARCHTECT/OWNER’S GENERAL CONDITIONS
A. The Owner’s Front-end Documents (General Conditions) shall be considered part of this
Page 245 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 11 of 31
Specification except where this Specification contains statements which are more definitive or more
restrictive than those contained in the General Conditions regarding a specific item or items. This
specification shall not be interpreted as waiving or overruling of any requirements expressed in the
General Conditions.
B. References in the General Conditions to “Engineer”, shall refer to the Consultant/Architect role in
this and related Sections.
1.13 APPLICABLE CODES, STANDARDS, PERMITS, AND INSPECTIONS
A. All audiovisual work shall meet or exceed the latest requirements of all National, State, City,
County, and other Authorities having Jurisdiction over the audiovisual work and the project.
B. Installation procedures, methods and conditions shall be in compliance with the latest
requirements of the Federal Occupational Safety and Health Administration (OSHA), the Americans
with Disabilities Act (ADA) and the Architectural Barriers Act (ABA).
C. The Contractor is responsible for all costs incurred to meet these codes and conditions.
D. Additional codes and industry standards and practices pertaining to the work:
1. International Building Code (IBC)
2. California Building Standards Code 2019 – Title 24
3. NFPA-72 National Fire Alarm and Signaling Code, 2013 Edition
4. International and National Electric Codes (IEC/ NEC)
5. IEC 60268-16 Third Edition 2003-05 Objective rating of speech intelligibility
6. ANSI/AVIXA
7. Sustainable Technology Environments Program
8. Underwriters Laboratories, Inc. (UL)
9. Building Industry Consulting Service International (BICSI) Telecommunications Distribution
Methods Manual - latest edition.
10. ANSI/TIA/EIA-568-B - Commercial Building Telecommunications Cabling Standard
11. ANSI/TIA/EIA-569 - Commercial Building Standards for Telecommunications Pathways and
Spaces
12. ANSI/TIA/EIA-606-A. Administration Standard for Commercial Telecommunications
Infrastructure
13. ANSI J-STD-607-A, Commercial Building Grounding (Earthing) and Bonding Requirements for
Telecommunications
14. EIA RS-232 Serial Communications Electrical Interface
15. EIA RS-310-C Racks, Panels and Associated Equipment
16. FCC Part 15
17. FCC Part 68
18. IEEE 802.3
19. California Electrical Code, 2019 Edition (adoption of NFPA 70 National Electrical Code, 2017
Edition)
a. Article 800 Communications Circuits
b. NFPA 75 Protection of Electronic Computer / Data Processing Equipment, 2013 Edition
1.14 CONFORMANCE WITH EXISTING SYSTEMS
A. In cases where systems and/or facilities in this scope of work ar e similar in nature to existing
systems and/or facilities:
1. The required hardware, system functionality and system flow shall conform to the existing
systems in order to share existing resources and minimize training requirements for the end
user. This includes, but is not limited to, the following:
a. Commonality in equipment
b. Commonality in operation
Page 246 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 12 of 31
c. Commonality in room layout
B. It is the responsibility of the Contractor to inspect the existing systems prior to beginning
engineering and fabrication to ensure consistency with any and all existing systems and notify the
design team of any discrepancies.
1.15 STATUS REPORTS
A. After the award of contract, the Contractor is responsible for providing weekly status reports
outlining his progress on the project. These reports should include information on the work
completed during the week, the work to be completed during the upcoming week and any potential
scheduling issues. The following should be included in this Status Report:
B. Expected date of project submittals, including equipment cut sheets, shop drawings, control
system interface designs, etc.
C. Anticipated completion date and percentage complete of in-house rack fabrication and testing,
prior to shipping to the job-site.
D. Anticipated completion date and percentage complete of control system programming, prior to
shipping to the job-site.
E. Schedule and percentage complete of on-site wiring and supervision.
F. Schedule and percentage complete of on-site installation.
G. Schedule and work -plan outline for owner training.
H. Schedule for systems checkout and turnover to the Owner.
1.16 RELATED WORK NOT IN CONTRACT (NIC)
A. Certain equipment and materials will be provided and installed by others. Unless otherwise
indicated in these specifications, or on the related drawings, these will inc lude the following:
1. Enterprise IP network hardware, such as IP switches, routers, wireless access points (WAPs),
enterprise servers and end-user computing devices, such as desktop PCs, tablets,
smartphones, and terminal hardware will be provided by the Owner’s IT group.
2. Enterprise IT infrastructure, such as horizontal and riser backbone and station copper UTP and
fiber-optic cabling, terminations, patch-panels, fiber trays and patch panels. All IT infrastructure
shall be coordinated and provided by the Owner’s IT group and their designated Contractors
and Subcontractors.
B. Though not under the scope of this document, the Audiovisual Systems Contractor is responsible
for coordination of these and any other related items required to provide and integrate a fully
functional AV system as described in this specification, including accessory hardware or cabling
necessary to interface to the NIC equipment.
1.17 OWNER FURNISHED EQUIPMENT
A. The Contractor shall be responsible for obtaining any new or existing OFE equipment fro m the
Owner. Existing equipment shall be brought back to the Contractor’s facility where they shall
ascertain that the OFE equipment is performing at or above factory specifications.
B. If existing equipment is not operating “as-new”, or is missing accessories necessary to be properly
integrated with the rest of the system as intended, the Contractor shall provide a proposal, including
a time line, for returning the equipment to “as-new” condition, provide the needed accessories,
arrange to have the owner replace equipment, or submit a proposal for replacement or alternative
equipment.
C. All designated Windows-based PC computers to be installed in rooms for use by staff will be OFE,
provided and configured by Owner’s IT Department.
D. The contractor shall coordinate with the Owner’s IT Department for all I/O interfacing and
performance requirements, including any specific hardware and software requirements, including:
Page 247 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 13 of 31
CPU or GPU performance, RAM, input connectivity and quantities (i.e.: HDMI, Display-Port, 3.5mm
audio USB 2.0/3.0 buses, etc.)
1.18 QUALITY OF MATERIALS AND EQUIPMENT
A. All materials and equipment supplied by the Contractor shall be new and shall meet or exceed the
latest published specification of the manufacturer in all respects.
B. The Contractor shall supply the latest model available at the time of order placement for each
piece of equipment.
C. All equipment shall be UL listed, or equivalent.
1.19 CONTRACTOR’S DOCUMENTATION
A. Pre-Construction Submittals
1. Prior to fabrication, the Contractor shall submit to the Owner’s Representative, for approval, any
custom designs pertaining to the systems. Contractor is to provide one (1) sets of all
documentation. Drawing submittals to be delivered electronically in PDF and working format
(such as AutoCAD 2013-2020) to ABD and the Owner, and at their option to the architect.
These designs include, but are not limited to, the following:
a. Complete system construction and point to point wiring schematic drawings, including all
component values, and showing complete letter and number identification of all wire and
cable as well as jacks, terminals, and connectors. All connections are to be shown; details
with “typical” connection diagrams are not acceptable.
b. Provide bound technical specification details (cut sheets) on all equipment required to
complete this project.
i. Product cut sheets shall include a bill-of-materials (BoM) itemizing all products, by
space and by system, including all selected options and accessories, for quick
review by the Consultant and Architect. Product submittals lacking this BoM will be
rejected.
ii. Where the same product is to be used in multiple spaces or systems, the Contractor
shall submit only one copy of product, using the BoM for each space to indicate
specifics of the product within that space, so as to minimize the size and complexity
of the product submittal.
iii. Product cut sheets shall be limited to the pages necessary to convey the product
selection with intent to order – showing model information and selected options or
accessories. Product cut sheets shall NOT include installation or owner/operator
manuals, installation drawings and diagrams. Product submittals over 5 -6 pages in
length will be rejected.
iv. Product cut sheets shall indicate color and/or finish selection, if applicable. Finish
and/or color should be included for selection or confirmation by the Architect or
Owner.
c. All control system GUI design pages, both touchpanel-based and button control , or
computer based as appropriate.
d. All control system panel layouts, where applicable.
e. All panels, plates, and designation strips, including details relating terminology, engraving
finish and color.
f. All custom designed structures, supports, rigging (motorized and fixed) consoles, tables,
carts, support bases, and shelves.
g. Schematic drawings of all custom components, assemblies and circuitry, including wall
and/or floor plates.
Page 248 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 14 of 31
h. All unusual equipment modifications.
i. Run sheets or field wiring details, indicating wiring types and quantities in each run or
pathway.
j. Patch panel assignment layout drawings.
k. Elevation Drawings of each equipment rack, both front and rear as appropriate.
l. All items of equipment, whether a stock manufactured item or custom -built item, shall be
supported by complete and detailed schematic drawings and replacement parts lists. No
“black boxes” or unidentified components shall be acceptable under this specification.
m. Verification of the focal lengths of projection lenses to achieve the specified image sizes.
n. Testing procedures, passing criteria and checklists for all systems included in this
specification. Testing procedures are to include (at a minimum) testing methods, materials,
equipment, and documentation of results to be provided
o. Note: Submittals not providing testing procedures will be rejected.
1.20 SUB-CONTRACT
A. In accordance with the General Conditions, no sub-contract will be permitted for the Contractor’s
responsibilities, as herein defined, unless specifically identified in the Bid submission and approved
by the Owner.
B. The Contractor shall have sole responsibility for the satisfactory implementation of each system,
even though the Contractor may have sub-contracted a portion of the installation or had certain
manufacturers install their own equipment.
1.21 COOPERATION WITH OTHER TRADES
A. It shall be the responsibility of the Contractor to cooperate at all times, and to the fullest extent,
with all trades doing work in the building, to the end that lost time, work stoppages, interference,
and inefficiencies do not occur.
B. It shall also be the responsibility of the Contractor to participate in the preparation of coordination
drawings and attend coordination meetings, before and during construction, at the request of the
Construction Manager. It is not anticipated that these meetings will be held more than once a week.
1.22 EQUIPMENT DELIVERY AND STORAGE
A. All equipment delivered prior to installation shall be stored by the Contractor at their place of
business. Costs of all shipping, and of all unusual storage requirements, shall be borne b y the
Contractor. The Contractor shall inform the Owner seven (7) days in advance of delivery to the site.
It shall be the responsibility of the Contractor to make appropriate arrangements, and to coordinate
with authorized personnel at the site, for the acceptance, handling, protection, and storage of
equipment so delivered.
1.23 CLEANUP AND REPAIR
A. Upon completion of work each day the Contractor shall remove all his refuse and rubbish from and
about the premises, and shall leave the relevant areas and equipment clean and in an operational
state. The Contractor shall be responsible for repairing any damage caused to the premises by the
Contractor’s installation activities, at no cost to the Owner.
1.24 OWNER TRAINING
A. The Contractor shall provide on-the-job training by a suitably qualified instructor, to personnel
designated by the Owner, to instruct them in the operation and maintenance of the systems. In the
event the Contractor does not have qualified instructors on staff for certain sophisticated
equipment, the Contractor will provide a manufacturer’s representative for such instruction to the
owner at no additional cost. All training shall take place after the systems are operational and
accepted. Owner is to retain 5% of contract fee until final acceptance as defined under the General
Page 249 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 15 of 31
Conditions.
B. There shall be a minimum of 12 hours, over four (4) sessions of end-user training included in this
specification. The cost to train owner’s personnel to service the equipment shall be listed separately
in the Bid Master Pricing Table. Training shall be broken into and cover the following topics:
1. Day to day operation of the systems for Council and Commission meetings, including:
a. Operation of the control systems touchpanel
b. Operation of the conferencing microphone systems
c. Operation of the cameras and camera auto-tracking software
d. Operation of the wireless presentation appliance
e. Operation of the recording/streaming appliance, including streaming, recording/saving,
publishing content
f. Operation of the display systems
g. Operation of the wireless microphone systems
2. Operation for public meetings and presentations
3. Procedures and operations for system malfunctions, including: frozen control panels, inoperative
displays, malfunctioning audio DSP and IP transport systems – including resetting endpoints
and/or switches
4. Procedures for cleaning and upkeep
5. Procedures for obtaining help-desk and service calls from the Contractor
1.25 PUBLICATION
A. No information relative to this job may be released for publication without prior written approval
from the Owner or Owner’s Representative.
1.26 INSURANCE
A. Refer to Section 5 of the General Conditions for Owner’s insurance and related requirements.
PART 2 - PRODUCT
2.1 EQUIPMENT AND MATERIALS—GENERAL
A. All equipment and components shall be new and the manufacturer's current model.
B. All components and the system as a whole shall meet or exceed the minimum standards issued
by the EIA and TIA.
C. All work and materials in conjunction with this installation shall meet or exceed the provisions of
the current edition of the California Electrical Code and other applicable codes.
D. The materials, appliances, equipment, and devices shall be tested and listed by Underwriters'
Laboratories, Inc. or other similar testing agency. The system shall be listed by U.L. or other testing
agency, and each major component shall bear the manufacturer's name, catalog number, and U.L.
or other testing agency label.
E. The Contractor shall be responsible for providing a complete and fully functional system, including
all necessary components, whether included in this specification or not.
F. Pricing for Alternates shall be provided on the same document as the base bid, under a separate
line item for each Alternate. All costs associated with each Alternate shall be included in the price
for each. Alternates will be evaluated against the Base Bid equally across Bids when determining
the lowest responsive Bid.
2.2 MANUFACTURERS
A. Listing of approved manufacturers for each component follows component description below and
within the Appendix ‘A’ documents.
Page 250 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 16 of 31
2.3 COMPONENTS
A. The approved manufacturers, quantities, and model numbers as noted in the Appendix ‘A’
documents shall form the basis of the system. These are minimum requirements. The Contractor
shall verify all quantities prior to ordering and installation. Quantities are provided for reference only.
The Contractor is still responsible to provide a complete and working system without claim for
additional payment. All equivalents and alternates must be approved by the Consultant prior to
system installation.
B. The Contractor shall furnish all equipment and work as noted on the drawings or specifications.
Contractor shall follow the specific design references and account for clear design intent. In case of
a conflict between the drawings and specification, furnish the equipment and work with the greatest
cost impact.
2.4 EQUIPMENT
A. Provide all equipment, including hardware devices, accessories, mounts and mounting hardware
as per the Appendix ‘A’ Equipment List included in the drawings. Provide pricing and quantities, per
manufacturer and model numbers listed.
B. Where options and accessory selections exist that are not identified in Appendix ‘A’, provide
pricing for base-line option, with finish, color or option selection to be determined through submittal
process, by Architect and Consultant.
C. Provide costs for all wiring, connectors, terminations, fasteners, labels, and miscellaneous
hardware not noted by individual lines under then row so named in the Appendix ‘A’ section.
D. Provide costs in the spaces provided, with the Bid Summary sheet to include totals for equipment,
and related costs for:
1. Engineering time
2. Pre-Installation labor and services
3. Installation labor and services (on-site)
4. General and Administrative Costs
5. Total for all Scope and Work
2.5 WIRE, PLATES, SPLITTERS, BOXES
A. AV plates (see drawings for details and qty): All panels and plates are to be constructed of
engraved black laminate with 1/8” steel backing or engraved black anodized aluminum unless
otherwise noted. All lettering is to be white and should be easily readable.
B. Mic/Line Wire -- (qty as needed): 22AWG 2-conductor with shield.
1. Belden 9451
2. West Penn 454
C. Speaker Wire main speakers – (qty as needed): 12 AWG, 2 conductors, twisted pair with overall
jacket.
1. West Penn 227
2. Belden New Generation 5000UE
3. Gepco 1200
D. Cat6 wire – (qty as needed): UTP Cat6 8 conductor, 24AWG, overall PVC jacket.
1. Belden 2413
2. West Penn 4246
E. Cat6 wire – (qty as needed): F/UTP Cat6 8 conductor, 23AWG, overall PVC jacket. Foil over CAT -
6 for all HD-BASE-T applications.
1. Belden 1351A
2. West Penn 4246F
Page 251 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 17 of 31
F. Refer to Part 3.1.D.16 table for complete list of acceptable wiring types for all AV applications.
PART 3 - EXECUTION
3.1 INSTALLATION PRACTICES
A. General
1. Installation shall include the delivery to the installation site, unloading, setting in place, fastening
to walls, floors, ceilings, counters, or other structures where required, interconnecting wiring of
the system components, equipment alignment and adjustment, programming and configuration
and all other work whether or not expressly required herein which is necessary to res ult in
complete and fully operational systems.
2. Prior to ordering equipment, the contractor shall coordinate the frequencies of all wireless
devices to prevent unwanted interaction between devices and rooms. This includes, but is not
limited to, wireless microphones, assisted listening system devices, wireless control panels, etc.
3. All accessories, including rack mounting hardware, power supplies, etc., shall be obtained from
the original equipment manufacturer. Unless otherwise noted or specified, third part y
accessories shall not be used.
4. All installation practices shall be in accordance with, but not limited to, these specifications and
drawings. Installation shall be performed in accordance with the applicable standards,
requirements, and recommendations of National, State, and Local authorities having jurisdiction.
5. If, in the opinion of the Contractor, an installation practice is desired or required, which is
contrary to these specifications or drawings, a written request for modification shall be made to
the Owner and Consultant. Modifications shall not commence without written approval from the
Consultant.
6. During the installation, and up to the date of final acceptance, the Contractor shall be under
obligation to protect his finished and unfinished work against damage and loss. In the event of
such damage or loss, the damage shall be replaced or repaired at no cost to the Owner.
B. Physical Installation
1. All equipment shall be firmly secured in place unless requirements of portability dictate
otherwise.
2. All equipment shall have an engraved plaque permanently affixed, denoting its function.
3. Fastenings and supports shall be adequate to support their loads with a safety factor as per
AHJ. All boxes, equipment, etc., shall be secured plumb and square.
4. Projectors, lenses, and mirrors shall be solidly mounted and braced or isolated, so that there is
no observable movement in the image induced by motor vibration or other mechanical
operations at the intended minimum viewing distance.
5. In the installation of equipment and cable, consideration shall be given not only to operational
efficiency, but also to overall aesthetic factors.
6. All overhead equipment must have security cables attached to the building structure to assist in
the prevention of loss as required by current California Building Codes.
C. Finishes, Trim and Escutcheon Components
1. To insure a proper finished appearance, the Contractor shall furnish and install trim/escutcheon
components at all conditions where A/V components pass through the finished ceilings. This
would include but not be limited to video projector supports, television monitor/receiver supports
and any other component which is not specifically supplied with integral flanges/trim
components; i.e. speaker mounts, assistance listening devices, etc.
2. The visible component of any trim should be minimal in size, preferably no wider than 1/2”. All
trim components at the ceiling plane shall be finished to match the approved ceiling finish. The
audiovisual contractor should obtain a sample from the General Contractor, including any
custom color information, or standard color numbers.
3. All visible components and finish options shall be submitted to the Owner and Consultant for
review and approval prior to fabrication.
D. Raceway Systems and Cable Installation
Page 252 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 18 of 31
1. All wire bundles are to be neat and combed free of cable crossovers.
2. All cables, regardless of length, shall be marked with a permanent, self-laminating wrap-around
number or letter cable marker at both ends, similar to the Panduit “Pan-Code” system. Labels
must be computer-generated for legibility. Wire labels done by hand in the field must be
replaced with computer generated labels. There shall be no unmarked cables at any place in the
system. Marking codes used on cables shall correspond to codes shown on drawings and or run
sheets.
3. All cables shall be grouped according to the signals being carried. In order to reduce signal
contamination, separate groups shall be formed for the following cable families:
a. Power cables
b. Control cables
c. Data cables (both IEEE 802 and proprietary signal types (HD-Base-T)
d. Video cables
e. Audio cables carrying signals less than – 20 dBm
f. Audio cables carrying signals between – 20 dBm and +20 dBm
g. Audio cables carrying signals above +20 dBm
4. As a general practice, all power cables, control cables, and high-level cables shall be run on the
left side of an equipment rack as viewed from the rear. All other cables shall be run on the right
side of an equipment rack, as viewed from the rear.
5. Cables ties shall be placed at appropriate intervals of no greater than six inches for vertical
bundles, two inches for horizontal bundles.
6. All vertical cable bundles shall be attached to the rack frame.
7. All cables shall be continuous lengths without splices. All system wire, after being cut and
stripped, shall have the wire strands twisted back to their original lay and be terminated by
approved soldered or mechanical means. Except where noted otherwise in the specifications,
NO BARE WIRE TERMINATIONS WILL BE ACCEPTED. Heat-shrink tubing shall be used to
insulate the ground or drain wire. Unused wires at the end of a cable shall remain unstripped
and shall be laid back and held in place with wire ties.
8. All solder connections shall be made with rosin-core solder using temperature-controlled solder
stations. Care shall be taken to avoid cold or cracked solder joints. Any connections that do not
appear to be clean and shiny, or which show signs of cracking, shall be re -soldered by the
contractor before final acceptance of the system.
9. Mechanical connections using insulated, crimp-type connectors shall be bonded to the
connector by soldering the wire to the metal part of the connector.
10. Connections made with screw actuated pressure type terminal strips shall be made by stripping
approximately 1/4 inch of insulation from the stranded conductor. Then the un-tinned wire shall
be inserted into the terminal and the screw tightened using a secure fitting precision screwdriver.
11. Terminal blocks, boards, strips or connectors shall be furnished for all cables which interface
with racks, cabinets, consoles, or equipment modules. No audio cables shall run directly to the
audio patch panel jacks. Each audio patch panel shall be furnished with an audio terminal block
and all audio cables to and from the audio patch panel shall terminate on this block.
12. All wire markers shall face a common direction.
13. All cables shall have proper connector housing.
14. Cables shall not protrude from the back of racks.
15. All cable entry shall be through the tops of racks or through entrance holes in the base of the
rack. No cable shall enter racks through front, rear or side panel openings.
16. Unless otherwise called for in these specifications and drawings, the following cables, or their
approved equals, shall be used in these systems:
Type Manufacturer Non-Plenum Plenum
RF-50 Ohm (Horizontal RG-8) Times Microwave Microwave LMR400
Page 253 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 19 of 31
RG-58 (50 OHM) Belden 8262 82240
Video (SDI) Belden 4505R 4505P
Control (4 conductor shielded) Belden 1502R 1502P
Control (12 conductor shielded) Belden 9556 6309FE
Audio (mic/line) (balanced or
unbalanced stereo)
Belden 9451/1266A 9451P
Audio (analog production intercom,
balanced stereo)
Belden 1266A/9451D 9451DP
Audio (8 Ohm program speakers) Belden 8473 1861A
Audio (70 Volt Speaker) Belden 8461 1863A
HD-Base-T (DM) CAT6a-F/UTP Belden 10GX62F 10GX 10GX63F
Ethernet, AV-over-IP CAT6a UTP Belden 10GX32 10GX 10GX33
Note: These cable types are cited to illustrate the type and quality of cable required. Unless otherwise noted,
cables from other manufacturers, i.e. Canare, CommScope, Extron, Gepco, Liberty, etc. will be considered if
data sheets indicating equivalency are submitted to Consultant for approval prior to installation.
17. All cables that can be terminated in the field (except video and pulse cables, which m ust be cut
to an electrical length) shall be cut to the length dictated by the run. No splices shall be
permitted in any pull boxes without prior permission of the Consultant. For equipment mounted
on casters, in drawers or on slides, the interconnecting c ables shall be provided with a service
loop of appropriate length.
18. No cable shall be installed with a bend radius less than that recommended by the cable
manufacturer.
19. Where cables are visible, the cables will be sheathed in a color wrap that has been subm itted for
approval by the Design Team.
E. Connection Plate Receptacles unless otherwise specified
1. Audio (microphone or line level) – XLR type.
2. Audio (loudspeaker level) – Neutrik Speakon®.
3. HD-Base-T – Neutrik Ethercon, Ruggedized RJ-45, CAT6A compliant, full-shielding for F/UTP
applications
4. Audio over IP (Audinate Dante, AES67, AVB (IEEE 802.1 TSN) - Neutrik Ethercon, Ruggedized
RJ-45, CAT6 compliant
5. 3G/12G SDI Video – BNC type (50 or 75 Ohm as required).
6. DVI (Inclusive of DVI-A, DVI-I and DVI-D signal types) – DVI-I type connector unless otherwise
specified.
7. HDMI – HDMI 2.0b compliant with locking nut.
8. USB – USB Type A (for 2.0/3.0 applications), USB Type C (for 3.0/3.1 and later applications,
including high-power charging).
9. Category 6/6A – RJ45 Type, full shielded body/barrel.
10. Note: All connectors on wall plates, or in other exposed locations, are to be recessed.
F. Patch Panel Assignments
1. All patch panels shall be wired so that signal “sources” (outputs from) appear on the upper row
of a row pair; and all “loads” (inputs to) appear on the lower row of a row pair.
G. Patch Panel Designation Strips
1. All audio and video patch panel designation strips shall utilize alphanumeric identifications and
Page 254 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 20 of 31
descriptive information. The jack position in each horizontal row shall be numbered sequentially
from left to right. The horizontal jack rows shall be lettered sequentially from top to bottom. The
alphanumeric identification of each jack shall be included on the functional block drawings, as
well as on reproductions of these drawings, which shall be mounted in an appropriate location
near the patch bays.
H. All IP switches furnished by the Contractor, whether specified by the Consultant or Owner, or not
specified, shall be verified for use in their intended application by the ma nufacturer of the transport
platform being supported by the IP switches in the systems. Applications shall include, but not be
limited to:
1. AV-over-IP transport platforms, such as:
a. Creston NVX
b. Extron NAV
c. AMX SVSi
d. QSC Q-Sys
2. Audio-over-IP transport platforms, such as:
a. AVB audio (refer to Part 3)
b. Audinate Dante
c. AES67 standard transport
I. Network switches provided shall meet the minimum bandwidth requirements, not only of the
endpoint nodes, but also provide adequate switching and ‘backplane’ bandwidth t o allow support of
all endpoint nodes that will be in simultaneous use in the system or network segment in question.
J. Maintaining Ground Integrity
K. In order to minimize problems resulting from improper grounding, and to achieve maximum signal -
to- noise ratios, the following grounding practices shall be adhered to in order to maintain the
integrity of the grounding system:
1. General
a. Because of the great number of possible variations in grounding systems, it shall be the
responsibility of the Contractor to follow good engineering practice, as outlined below, and to
deviate from these practices only when necessary to minimize crosstalk, ground loops,
ground- induced noise, and to maximize signal-to-noise ratios in the audio, video, and control
systems.
2. System Power Ground
a. A single primary “system ground” shall be established for the system in each particular
area. All grounding conductors in that area shall connect to this primary system ground.
b. The system ground shall be provided at the audio equipment rack for the area, and shall
consist of a copper bar of sufficient size to accommodate all secondary ground conductors. A
copper conductor having a maximum of 0.1 Ohms total resistance shall connect the primary
system ground bar to the nearest approved ground. The Contractor shall be responsible for
determining if the metallic conduit is properly electrically bonded to the building ground
system.
c. Secondary system grounding conductors shall be provided between all racks, audio
consoles, and audiovisual system equipment local to the area. Each of these grounding
conductors shall have a maximum of 0.1 Ohms total resistance.
d. Under no conditions shall the AC neutral conductor, either in the power panel or in a
receptacle outlet, be used as a system ground, except as specifically defined by NFPA 70 for
bonding.
Page 255 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 21 of 31
e. Ungrounded equipment with either an inline transformer or a 2-prong plug, shall be
bonded to the rack bus bar using #12awg cable.
3. Audio Cable Shields
a. All audio cable shields shall be grounded at one point only. There ar e no exceptions. For
inter and intra-rack wiring, this requires that the shield be connected at one end only. For
ungrounded portable equipment, such as microphones, the shield shall be connected at both
ends but grounded at only one end.
4. Video Receptacles
a. All video receptacles that are provided and installed by the Contractor shall be insulated
from the mounting panel, outlet box, or wireway. Unless otherwise detailed herein, this shall
be accomplished by using insulated-from-panel type receptacles.
5. Audio Receptacles
a. All audio receptacles that are provided and installed by the Contractor shall be insulated
from the mounting panel, outlet box, or wireway. Unless otherwise detailed herein, this shall
be accomplished by using insulated-from-panel type receptacles.
3.2 GENERAL SYSTEM PERFORMANCE STANDARDS
A. Unless restricted by the published specifications of a particular piece of equipment, or unless
otherwise required under the Detailed Specifications, the following performance standards shall be
met by each system. The signal paths for the above Performance Standards shall be as follows:
From all source inputs to all signal destinations. See Contractor System Checkout 3.3 for testing
procedures.
B. Analog Audio
1. Frequency Response: Within plus or minus 0.5dB, 20 Hz to 20,000 Hz
2. Signal to Noise Ratio: greater than 90dB (including crosstalk and hum at all input/output levels)
3. Total Harmonic Distortion: 0.05% maximum from 20 Hz to 20,000 Hz.
4. Input Levels
a. Microphone (Nominal) ........................... -50dbu
b. Overload (Minimum gain) ...................... -5dbu
c. Maximum Gain....................................... -26dbu
d. Line (Nominal) ....................................... +4dbu
e. Overload (Minimum gain) ...................... +24dbu
f. Maximum Gain....................................... +9dbu
g. Input Common Mode Rejection.............. >100db Output Levels
h. Line (Nominal) ....................................... +4dbu
i. Maximum................................................ +24dbu
j. Output Impedance................................... < 0.5 Ohms
k. Load Impedance...................................... >150 Ohms
C. 3G SDI – Per SMPTE 424M
D. 12G SDI – Per SMPTE ST-2082
E. HDMI – Per HDMI Ver. 1.4b; HDMI 2.0b
F. DVI – Per DVI Ver. 1.0
G. Display Port Version 1.4
Page 256 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 22 of 31
H. Audio Video Bridging (AVB)
1. IEEE 802.1AS: Timing and Synchronization for Time-Sensitive Applications
2. IEEE 802.1Qat: Stream Reservation Protocol (SRP)
3. IEEE 802.1Qav: Forwarding and Queuing for Time-Sensitive Streams
4. IEEE 802.1BA: Audio Video Bridging Systems
I. Audiovisual System, Control System and User Interface Programming
J. Control system user interfaces pages and programming shall be designed for this project
exclusively. While there are a great number of design approaches to designing the user interface,
the following guidelines shall be adhered to:
1. The use of custom system programming from prior projects and/or ‘modules’ provided by a
given manufacturer or programmer may or may not meet the functional intent of the systems
and work described herein. It is the responsibility of the contractor to meet the functional intent
of the systems in this specification, including any and all necessary modification of program
code or creation of custom modules as required.
2. The operation(s) of all system(s) are to match the functional intent already implemented at the
owner’s facilities as applicable.
3. All panels are to have the time and date as icons, in the same position on every page.
4. All panels are to have a title, indicating the piece of equipment and/or functionality being
controlled.
5. Final programming shall include capability to remotely control all functions of the audiovisual
system. Only functions required for normal use shall appear on top level pages while underlying
“Tech Pages” shall provide access to full manufacturer’s remote-control functionality.
6. Devices similar in nature shall be programmed to operate with a common format.
7. No individual component shall be programmed to function atypically.
8. Whenever the same button appears on more than one page, it will be in the same position on
each page.
9. Where feasible, multi-level access to controls should be implemented. See paragraph “5”,
above.
10. During performance testing, all equipment shall be operated under standard conditions as
recommended by the manufacturer.
11. Please see Detailed Specifications for further information on specific control system
programming requirements.
3.3 CONTRACTOR CLOSEOUT DOCUMENTATION
A. Close Out Submittals
B. At the completion of the installation, the Contractor shall provide one (1) set of electronic copies,
and to the Owner one (1) set of hard-copies of each of the following:
1. Test results, in “spreadsheet” format, of electrical audio and/or video performance testing for all
systems end-to-end in every room and/or between rooms as applicable.
2. Note: It is the sole responsibility of the Contractor to fully test the audiovisual systems prior to
Consultant check-out and verification. Until these test results are provided, no audiovisual
systems check-out or verifications (functional or otherwise) will be performed by t he Consultant.
If any anomalies in system performance are detected, the Contractor shall correct these before
performing any other tests.
3. Results of RF Spectrum analysis as used to establish available frequencies for wireless devices
included in this contract.
4. Equipment manufacturer’s operation manuals for each piece of equipment.
5. “As-built” drawings for every item indicated in the “Detailed Specification” sections of this
specification as installed. A final, approved copy shall be placed in a metal pocket mounted on
the inside of the rear door of the rack. Contractor to coordinate the preferred format (hard copy
or digital) of these documents with the owner upon completion.
6. System functional block drawings showing all input and output circuit cable and term inal block
numbers as well as all jack field circuit I.D. designations. A copy of these drawings shall be
Page 257 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 23 of 31
framed in protective plastic and mounted near the equipment racks, or as otherwise directed by
the owner.
7. A System Operation and Maintenance Manual. This manual shall be produced by the Contractor
especially for the systems detailed herein. The “Operation” section shall describe all typical
procedures necessary to activate each system to provide for the functional requirements as
listed under the Detailed Specifications. Manuals will use graphical representation of touch
panel screens, as to easily be identified by user. Owner’s Manuals and/or Operations manuals
supplied by manufacturers for a given piece of equipment, though required, are not acceptable
substitutes for these materials.
8. The reader of this manual shall be assumed to be technically competent, but unfamiliar with this
particular facility. Additionally, the Contractor shall provide a single page of basic operating
instructions for each room, and other audio-visually equipped spaces.
9. The “Maintenance” section shall provide a recommended maintenance schedule with reference
to the applicable pages in the manufacturer’s maintenance manuals. Where inadequate
information is provided by the manufacturer, the Contractor shall provide the information
necessary for proper maintenance.
10. In addition to the Operation and Maintenance Manual(s), the contractor shall provide a simplified
user’s guide (“cheat sheet”) for each audiovisual system.
C. Acceptance Testing
1. System acceptance testing shall not be conducted until all final “as -built” drawings, manuals and
operational testing have been completed and documentation has been submitted for
Consultants review.
2. Acceptance testing shall be conducted with AV Contra ctor, Consultant, and Owner in
attendance.
3. Contractor shall demonstrate that all components of the Audiovisual Systems are in proper
working order and comply with specifications.
4. At time of acceptance testing, all items found to be outside of specification requirements; Owner
requirements, code requirements or general installation practices shall be added as new items
to the final Punch List. All items found outside of specification requirements shall be fully
functional prior to final acceptance of system .
5. The AV Contractor shall compile an inventory of installed equipment prior to time of acceptance
testing and compared against equipment listed in contractual documents.
6. Acceptance testing may be suspended by Consultant if Audiovisual Systems are not complete
and operable, equipment failure occurs, or installation is not in accordance with specifications.
AV Contractor shall be responsible for any costs incurred by Consultant for additional site visits
required to complete acceptance testing.
D. Software Documentation
1. As part of the audiovisual control system the AV Contractor shall enter into a software license
agreement with the Owner for all custom software interfaces provided as part of this contract.
Unless specifically agreed to separately by the Owner and Contractor in subsequent documents
holding precedence, the following sample software license agreement shall be adhered to.
“Sample Software License Agreement
This Software License is made by AV Contractor to Owner as an essential element of the services to be
rendered by the AVC as defined in the system specification and any associated documents.
Owner and AV Contractor agree that this Software License is deemed to be part of, and subject to, the
terms of the Agreement applicable to both parties.
SECTION 1
LICENSE GRANT AND OWNERSHIP 1.1
The AV Contractor hereby grants to Owner a worldwide, perpetual, non-exclusive, non-transferable
license to all software for Customer's use in connection with the establishment, use, maintenance and
modification of the system implemented by the AVC. The term “Software” for the purposes of the license
agreement shall refer to all source code, executable object code, and the patches, scripts, modifications,
Page 258 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 24 of 31
enhancements, designs, concepts or other materials that constitute the software programs necessary for
the proper function and operation of the system as delivered by the AVC and accepted by the Owner.
1.2
Except as expressly set forth in this paragraph, the AVC shall at all times own all intellectual property
rights to the software. Any and all licenses, product warranties or service contracts provided by third
parties in connection with any software, hardware or other software or services provided in the system
shall be delivered to Owner for the sole benefit of Owner.
1.3
Owner may supply to the AVC or allow the AVC to use certain proprietary information, including service
marks, logos, graphics, software, documents and business information and plans that have been authored
or pre-owned by Owner. All such intellectual property shall remain the exclusive property of Owner and
shall not be used by the AVC for any purposes other than those associated with delivery of the system.
SECTION 2
COPIES, MODIFICATION, AND USE
2.1
Owner may make copies of the software for archival purposes and as required for modifications to the
system. All copies and distribution of the software shall remain within the direct control of Owner and its
representatives.
2.2
Owner may make modifications to the source code version of the software, if and only if the results of all
such modifications are applied solely to the system. In no way does this Software License confer any right
in Owner to license, sublicense, sell, or otherwise authorize the use of the software, whether in executable
form, source code or otherwise, by any third parties, except in connection with the use of the system as
part of Owner's business.
2.3
All express or implied warranties relating to the software shall be deemed null and void in case of any
modification to the software made by any party other than the AVC.
SECTION 3
WARRANTIES AND REPRESENTATIONS
The AVC represents and warrants to Owner that:
3.1
It has all necessary rights and authority to execute and deliver this Software License and perform its
obligations hereunder and to grant the rights granted under this Software License to Owner;
3.2
The goods and services provided by AVC under this Software License, including the software and all
intellectual property provided hereunder, are original to the AVC or its subcontractors or partners; and
3.3
The software, as delivered as part of the system, will not infringe or otherwise violate the rights of any third
party, or violate any applicable law, rule or regulation.
3.4
The AVC further represents and warrants that, throughout the System Warranty Period, the executable
object code of software and the system will perform substantially in accordance with the System
Specifications and this Agreement. If the software fails to perform as specified and accepted all remedies
are pursuant to the policies set forth in the Specification and in the Agreement.
3.5
Subsequent to system certification, source code changes and/or additional programming, whether
requested by Owner or performed by AVC, will be warranted by the vendor for a period of one (1) year,
with the vendor responsible for the diagnosis and repair of any erroneous Software. The vendor shall
ensure that the current program is saved to a portable electronic media format and delivered to the Owner
as part of the close-out documentation. No program resident in a control system shall be overwritten until
a back-up of the resident program is written and turned over to the Owner.
3.6
An acceptance test will be performed for a ten (10) day period, during which changed or additional code
Page 259 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 25 of 31
must perform accurately and error free.
SECTION 4 INDEMNIFICATION
4.1
The AVC hereby indemnifies and shall defend and hold harmless Owner, its parent companies and its and
their subsidiaries, affiliates, officers, directors, employees, agents and subcontractors from and against all
liability, damages, loss, cost or expense, including but not limited to reasonable attorneys' fees and
expenses, arising out of or in connection with any breach or alleged breach of the Agreement or any
damage or claimed caused or alleged to have been caused by the negligent or willfully wrongful act or
omission of Contractor or any of its subcontractors, agents, officers or employees, or any third party
claims that the software or system here provided by the AVC infringes or otherwise violates any rights of
any such third party.
4.2
Owner hereby indemnifies and shall defend and hold harmless the AVC, its and their subsidiaries,
affiliates, officers, directors, employees, agents and subcontractors from and against all liability, damages,
loss, cost or expense, including but not limited to reasonable attorneys' fees and expenses, arising out of
or in connection with any third party claims that Owner's use of the software in contravention of the grant
of rights infringes or otherwise violates any rights of any such third party.
4.3
Upon the assertion of any claim or the commencement of any suit or proceeding against an indemnitee by
any third party that may give rise to liability of an indemnitor hereunder, the indemnitee shall promptly
notify the indemnitor of the existence of such a claim and shall give the indemnitor reasonable opportunity
to defend and to settle the claim at its own expense and with counsel of its own selection and approved by
indemnity, such approval not to be unreasonably withheld.. The indemnitee shall cooperate with the
indemnitor, shall at all times have the full right to participate in such a defense at its own expense and
shall not be obligated, against its consent, to participate in any settlement which it reasonably believes
would have an adverse effect on its business.
SECTION 5
TRANSFER AND TERMINATION
This license will automatically terminate upon the disassembly of the system subject to Section 4.1, unless
the system is reassembled in its original configuration in another location.
The AVC may terminate this license upon notice for failure to comply with any of the terms set forth in this
Software License. Upon termination, Customer is obligated to immediately destroy the software, including
all copies and modifications.”
2. The Bidder shall offer an annual “Software and Firmware Maintenance” contract. This shall
cover all software and firmware provided as part of this system and/or written for this system,
and shall include both routine upgrades to applications and operating systems, as well as any
modifications to software that may be required by any manufacturer. The Software
Maintenance contract shall commence immediately after expiration of the warranty period, and
continue for three (3) years.
E. Distribution
1. Three copies of the above documentation will be retained by the Owner.
2. One copy of the above documentation will be retained by the Architect.
3. One copy shall be delivered to the Owner’s Representative prior to the System Commissioning.
4. At least one copy of the above documentation will be retained by the Contractor.
F. Procedure for Resubmitting
1. Make corrections or changes in O & M and/or Record Drawings as required by the Architect and
resubmit when the Architect’s stamp requires re-submittal.
2. Clearly identify changes made other than those specifically requested by the Architect when
resubmitting Record Drawings. Changes shall be clouded or similarly highlighted as coordinated
with the Architect. Only changes that have been specifically requested by the Architect or have
been clouded by the Contractor will be reviewed on resubmittals.
3. Any drawing sheets added to the resubmittal shall be clearly identified and clouded, and shall
Page 260 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 26 of 31
not change the sheet numbering scheme for previously issued Record Drawings.
4. The Contractor shall be responsible for any delays caused by the re-submittal process.
3.4 CONTRACTOR SYSTEM CHECKOUT
A. Before Commissioning Tests are scheduled, the Contractor shall perform his own system
checkout based upon an approved testing procedure for the systems. The Contractor shall furnish
all required test equipment and shall perform all work necessary to determine and/or modify
performance of the system to meet the requirements of this specification. The Contractor shall
submit a testing plan (refer to 1.18-A.-15) for approval by the individual or firm representing the
Owner during the Audiovisual Installation. At a minimum, the following sub-components of the
Audiovisual System shall be tested and verified:
1. Cable and Connectors
a. All cables and connectors shall be tested and verified to comply with the manufacturer’s
specifications and design intent.
b. Cable test results shall be submitted in advance of the Commissioning for review by the
Owner’s Representative.
2. Devices
a. All devices shall meet the functionality as specified by manufacturer.
b. If any device is found to deviate from the manufacturer’s functionality it shall be replaced
by the Audiovisual Systems Contractor at no cost to the Owner.
3. Signal Types
a. The Audiovisual System shall be tested to comply with all video and audio standard s as
specified in the Performance Standards section.
4. System Function
a. The cables and connectors, devices, and signal types shall meet the functional
requirements as specified by their respective manufacturer and the Consultant.
b. Acceptable testing procedures may include but is not limited to that which is described in
the detailed specifications such as (streaming, push-to-talk, annotation, etc.)
5. Document that all matrix switching crosspoints have been tested and verified.
6. Test all audio and video systems for compliance with the Performance Standards, using the
example procedure outlined in Appendix A:
a. Test Equipment.
i. The following test equipment (or submit equivalent for approval) shall be used to test
the systems on site:
a) Video Testing:
i) Digital video and Audio test generator, Extron VTG 400 DVI
ii) Digital Video test generator with EDID and HDCP components, PureLink
HDG-8000 PRO
iii) Media and portable hardware (i.e laptop) representative of all types found
in the subject system including but not limited to Blu-ray ™ players and
discs (provide discs with and without HDCP encrypted content), mobile
PC/Tablets.
iv) Video cable
v) Set of terminations, ‘T’ pieces etc.
b) Audio Testing:
Page 261 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 27 of 31
i) Time based measurement system, Goldline TEF20 or SIA Smaartlive with
laptop PC, calibrated omnidirectional mic, and appropriate interfaces
ii) Audio test set, Audio Precision ATS-1DD
iii) Media representative of all types found in the subject system
iv) Audio cables as required to connect test equipment to the system
v) Set of terminations, adapters etc.
c) Gain Setting
i) Adjust all systems (end to end within a system) for maximum signal-to-
noise ratio. No hiss should be audible through any loudspeaker at the
completion of gain structure setting, and all audio gain stages should clip
simultaneously.
d) Signal Paths - Video/Audio
i) Connect the output of the video signal generator to a floor box/table/rack
connector and select the “Full Field Color Bar” signal. Connect the
combined waveform monitor/vector-scope to a final output point, e.g. an
input to a picture monitor or video projector. Ensure that the test signal is
routed to the selected output.
ii) Measure and record the signal amplitudes.
iii) Repeat item ‘i’ after selecting the “Multi-burst, 50 IRE” test signal.
iv) Measure and record the signal amplitudes.
v) Repeat item ‘i’ after selecting the “Modulated 5-step” test signal.
vi) Measure and record the signal differential phase and gain.
vii) Repeat item #’s ‘i’ through ‘vi’ for other video signal paths.
viii) Repeat item ‘i’ after selecting the Window test signal.
ix) Measure and record the signal line and field tilt.
x) Repeat item ‘i’ after connecting the Black Burst signal from a rear
mounted connector.
xi) Measure and record the signal/noise ratio.
xii) Connect the output of the audio test set to a floor box/table/rack program
audio connector and connect the input of the audio test set to a final
output point, e.g. an input to a program speaker power amplifier. Ensure
that the test signal is routed to the selected output, that the volume control
is set to 100% and that the equalizers are bypassed.
xiii) Measure and record the signal/noise ratio, total harmonic distortion and
frequency response.
xiv) Repeat items ‘xii’ and ‘xiii’ for other audio signal paths.
xv) Connect the output of the audio test set to a floor box/table/rack speech
audio connector and connect the input of the audio test set to a final
output point, e.g. an input to a speech speaker power amplifier. Ensure
that the test signal is routed to the selected output, that the volume control
is set to 100% and that the equalizer is bypassed.
xvi) Measure and record the signal/noise ratio, total harmonic distortion and
frequency response.
xvii) Repeat items ‘xv’ and ‘xvi’ for other audio signal paths.
Page 262 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 28 of 31
xviii) Connect the output of the signal generator to a floorbox/table/rack ‘Left’
and ‘Right’ connectors and select the 1kHz tone. Chec k that the signal is
emitted from the left and right program speakers.
xix) Repeat item ‘v’ for other audio connection location.
e) HDMI
i) Using an appropriate HDMI generator, HDCP enabled, test for correct
resolution and timing of all HDMI input signals and signal transmission
coming into the display using the entire cabling path to the extent
possible.
ii) Test each HDMI input to verify working condition.
iii) Test and verify video type, picture and audio.
iv) Verify HDCP sources can be routed to all destinations.
v) Verify EDID configuration and functionality.
vi) Verify CEC functionality (if being implemented) and that automatic CEC
functions do not affect the display.
vii) Verify displays can switch between and display different resolutions and
color space.
viii) Verify images are stable, no scaling artifacts or latency.
f) HDMI 2.1
i) Future capabilities to include: 4K@120 up to 8K@60, resolution up to 10K,
48 Gbps b/w uncompressed, backwards compatible, eARC, VRR, QMS,
QFT, ALLM.
ii) 4K
1. Test and verify HDMI cables and product can support 4K
functionality when connected to a 4K device.
2. Test and verify HDMI can transport 4K video at 50-60 frames per
second, support 4096 x 2160 (UHD 3840 x 2160) resolution, color
bit depth 10bit up to 12 bit.
iii) Data rates
1. Test and verify HDMI can pass data rates at a minimum of 10.2
Gbit/s and up to 18.0 Gbits/s.
iv) Refresh rates
1. Test and verify product can support common refresh rates up to
120Hz.
g) KVM/USB
i) Test and verify USB-passes high speed, functional, electrical, mechanical
and legacy compliance testing.
ii) Can use a USB test tool analyzer or software test package to verify driver
and hardware interoperability.
iii) Test and verify USB 2.0, 3.0, or 3.1 performance pertaining to system
design.
iv) Test and verify that USB host and endpoint function correctly for its
Page 263 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 29 of 31
intended application.
v) If using USB as a controller:
vi) Verify that host can recognize attached devices and install appropriate
drivers.
vii) Verify power budget if connecting to multiple devices, that power does
not exceed manufacture specified power requirements.
viii) If using USB or KVM extenders, test and verify all data cables and
connectors pass conformance testing. This includes but not limited to data
rates, skew, return loss, resistance etc. according to test manufacture
specifications.
h) HD-Base-T
i) Test and verify all data cable and connectors pass conformance testing.
This includes but not limited to data rates, skew, return loss, resistance
etc. according to test manufacture specifications.
ii) Test and verify audio source and video source from point of origination
through HD-Base-T system to the destination functions correctly.
iii) Test and verify rs232 control functionality.
iv) Test and verify HD-Base-T system functions within system configuration.
i) Streaming
i) Bit Rate – image quality, 8-15 Mbps
ii) Latency - ensure that a minimal level of audio quality and latency are
sustained so as to not degrade the user experience.
iii) Buffer – how long before the video loads and ready to watch.
iv) Lag – is the playback smooth, watch and wait time.
v) Does the network service provided by the ISP furnish the necessary
QOS to acquire, render, search, broadcast and deliver content for the
intended application?
ix) Check that the image is correctly displayed on the picture flat panel
display(s) and/or by the video projector.
j) Display Set-up and Calibration:
i) Set up display for intended usage per manufacture recommendations.
ii) Allow display to warm up to standard operating temperatures.
iii) Setup and verify that display is set to its native resolution
iv) Setup and verify correct aspect ratio, verify no overscan or underscan.
v) Bring up a proper test pattern.
vi) Perform colorimetry calibration.
vii) Set pixel clock and phase as required.
viii) Use a black PLUGE pattern, or appropriate test pattern generator to set
black level.
ix) Use a white PLUGE pattern, or appropriate test pattern generator to set
white level.
B. At the conclusion of the tests, return all equipment settings to previously calibrated positions.
C. Provide written records of all test results in spreadsheet form.
Page 264 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 30 of 31
D. Check all control functions, from all controlling devices to all controlled devices, for proper
operations.
E. Adjust, balance, and align all equipment for optimum quality and to meet the manufacturer’s
published specifications. Establish and mark normal settings for all level controls, and record these
settings in the “System Operation and Maintenance Manual”.
F. Check all optical projection images for average light level, light fall-off, and image alignment and
size to comply with the Performance Standards and specifications drawings. Check to determine
that all projectors, projector bases, carts, tables, and mirrors are rigid and vibration -less in
operation.
G. Maintain documentation of all performance tests for reference by the Owner’s Representative
during the Commissioning.
3.5 COMMISSIONING TESTS
A. Commissioning Tests will not be performed until the Contractor’s System Checkout has been
completed and the test results have been reviewed. The Commissioning Tests will be supervised
by the Owner’s Representative and shall consist of the following at a minimum:
1. A physical inventory of all equipment on site and will be compared to equipment lists in the
contract documents.
2. The operation of all system equipment shall be demonstrated by the Contractor.
3. Review of final As-Build documentation as described in the “Contractors Documentation” section
of this specification.
B. Both subjective and objective tests will be required by the Owner’s Representative to determine
compliance with the specifications. The Contractor shall be responsible for providing test equipment
for these tests.
C. In the event further adjustment is required, or defective equipment must be repaired or replaced,
tests may be suspended or continued at the option of the Owner’s Representative.
D. Any charge for additional time incurred by the Owner’s Representative required to over-see the
system tests, due to improper system installation or previous failed systems, shall be the
responsibility of, and charged directly to the contractor.
E. Note: As noted in 1.5, “Warranty Statement” and 1.6 “Preventative Maintenance & Service
Contract,” Warranty and Preventative Maintenance Periods shall commence after final
commissioning by both the Owner and Consultant.
3.6 SERVICE IDENTIFICATION PLATE
A. All installations shall bear the following service identification plate, supplied by this contractor,
mounted on the front of the main rack at the top, using the Maven Pro typeface:
SYSTEMS DESIGNED BY:
ABD Engineering & Design, Inc.
321 SW 4th Avenue
Suite 700
Portland, OR 97204
503-444-5656
SYSTEMS FABRICATED, INSTALLED & SERVICED BY:
(This Contractor)
Engraving shall be white filled lettering on a black background or as appropriate to the identification plate
material.
Page 265 of 390
City of Ukiah California ABD Project #P2703 July 14, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COMMON WORK RESULTS FOR AUDIOVISUAL SYSTEMS
27 41 00 - Page 31 of 31
PART 4 - APPENDIX A – EQUIPMENT LISTS
A. See the attached Appendix for the equipment lists for the audiovisual systems. These lists are
provided for the bidding process
END OF SECTION 274100
Page 266 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COUNCIL CHAMBERS AUDOIVISUAL SYSTEMS
27 41 20 - Page 1 of 9
SECTION 27 41 20 – COUNCIL CHAMBERS AUDIOVISUAL SYSTEMS
PART 1 - GENERAL INFORMATION
1.1 OPERATIONAL SUMMARY & SCOPE
A. This section of the specification describes the functional details of the audiovisual systems to be
furnished and installed in the Council Chambers of the City of Ukiah.
B. The Systems in the Council Chambers are to be a complete replacement of all systems
components, hardware, cabling, connectors and associated devices. Essentially, this project is a
“forklift upgrade” of the AV systems, and shall be bid as such.
C. The Systems Scope shall include interfacing new AV systems to an existing SDI-to-fiber ingest
device, which is connected to the demarcation cabinet of the local community access television
provided for the City (Comcast, herein referred to as “CATV”) All systems owned and operated by
CATV shall be left-in place for the duration of the project. If, for whatever reason, CATV
equipment needs to be moved or relocated to enable Work, the Owner and their designated
CATV representative shall be informed ahead of the Work, and allowed to relocate, remove
and/or reposition equipment to allow the necessary Work.
D. BID ALTERNATE ‘A’ - The Scope shall include replacement of existing lighting switches for
control of two (2) 277 Volt switched and two (2) 120V dimmable circuits. Lighting controls shall
include coordinated work to install controller cabinet, controller, and switching/dimming modules in
the existing electrical room – adjacent to the existing lighting panelboards. Existing wall switches
to be replaced with new low-Voltage keypads and provide integration to the AV Master Control
Processor for control through the Clerk’s touchpanel.
E. Events hosted in this space will include, but not be limited to:
1. Council Meetings – These meetings are also recorded as official records, along with voting
tallies, minutes, and audio and video content to the CivicPlus system under contract to the
City.
2. City staff and management meetings – Internal meetings with audio-conferencing and web-
conferencing, using an Owner PC hosting UC software.
3. Related Public and Community Meetings – Public meetings with or without recording or
conferencing.
4. Meetings with confederate organizations – Internal and Web-conferences with partner City
authorities and related organizations, including public programs such as documentary
festivals.
F. All systems shall be dedicated and permanently installed as described above and, in the following,
‘functional’ descriptions.
1.2 RELATED WORK
A. Installation of new or modified wall boxes, pathways, floor-box fittings (excluding any plates and
connectors to be provided by the contractor.
B. Modification of ceiling, ceiling soffits and wall finishes as needed to install items in paragraph A
above, as well as new motorized projection screen, projector, loudspeakers, cameras and
associated equipment.
C. Modification of existing millwork, including dais, podium, Clerk’s desk, table and other FF&E items,
including coordination with the City’s project manager, carpenter’s and related City
subcontractors.
D. Telephone and telecommunications jacks and special telecom outlets not related directly to AV,
(LAN/WAN, Wireless access points (WAPs), PTSN/POTS, etc.).
E. Provide in accordance with Section 27 41 00 – Audiovisual Systems.
1.3 SYSTEM INTERCONNECTION & FUNCTIONAL DESCRIPTION
Page 267 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COUNCIL CHAMBERS AUDOIVISUAL SYSTEMS
27 41 20 - Page 2 of 9
A. Functional intent
1. The Systems provided in the room, and general layout shall consist of the following locations
and associated functions:
a. The dais will seat up to 7 positions, with the following positions:
i. The Clerk’s position is at a dedicated table at the front-center of the dais. Functions
at the Clerk’s position shall include:
a) Control of the room systems – including:
i) Presentation source: Dais seat HDMI – including ones at the Clerk’s own
position, Podium HDMI, Clerk’s PC (UC/Web-conference & CivicPlus host),
Wireless presentation appliance, Recording/streaming device output and
interface to CivicPlus software.
ii) Control of presentation destination displays, Flat-panel-display (All), front or
rear flat panel displays, or projection system
iii) Response to request-to-speak and moderator controls of conference
microphone systems, including mute all or selective muting
iv) Start, Stop, and Pause of the room recording/streaming appliance, as well
as Write/Save and Playback functions
v) Control of room lighting – per Bid Alternate ‘A’
vi) Control of room volume and audio/video muting
vii) Control of room PTZ Camera selection, camera position and camera
presets, including:
viii) Control of the auto-tracking camera functions, including hosting auto-
tracking client software
b) A local PC, on the secure City enterprise network, to host City content as well as
UC/Web-conferencing software, and CivicPlus web-interface/client software
c) A captive cable box with a local HDMI cable input, as well as pass through for
USB cables, and 120V power and USB power for a laptop and smart-devices.
d) A gooseneck microphone/speaker unit, as part of the conference/discussion
microphone system in the room.
e) A pair (2) of desktop monitors and stands to display the local PC, as well as
selected program content being displayed on the Main Room display as well as
Dais displays – which may include the Clerk’s laptop extended desktop.
ii. Five (5) current, plus two (2) side positions for City Attorney and City Manager, with the
Council President at the centermost position. Each position features:
a) A gooseneck microphone/speaker unit, as part of the conference/discussion
microphone system in the room.
b) A captive cable box with a local HDMI cable input, as well as pass through for
USB cables, and 120V power and USB power for a laptop and smart-devices.
(shared per two (2) seats)
c) A desktop monitor and stand, which will duplicate the content also shown on the
Main Room display.
Page 268 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COUNCIL CHAMBERS AUDOIVISUAL SYSTEMS
27 41 20 - Page 3 of 9
iii. A table to the audience-right of the dais, which will serve two (2) city employees in
attendance, along with wireless gooseneck microphones and a table box with local
HDMI cable input, as well as pass through and 120V and 5V USB power.
iv. A podium, at the center of the dais, between the audience and the Clerk’s position, to
allow presentation by speakers from the public, guests, and staff. The podium will also
feature:
a) A gooseneck microphone unit, as part of the conference/discussion microphone
system in the room.
b) A captive cable box with a local HDMI cable input, as well as 120V power
c) Devices in the podium will be routed via cabling to the room systems through a
pass-thru pathway to the clerk’s desk/dais, where they can be fed into the room
systems via dais pathways.
b. The Audience area and perimeter of the Council Chambers will include:
i. Wireless microphone systems to accommodate presenters and small tabled
conferences.
ii. Ceiling microphones to pick up audience questions and discussion
iii. Wireless presentation appliance, for presentation of content over Wi-Fi from user
devices, including Windows, OSX, iOS, Android, Chromecast and others.
iv. Wall mounted columnar loudspeakers for voice amplification and program audio
v. Reuse of existing soffit recessed ceiling speakers, and amplified zone serving the
Chambers and adjacent corridor passages.
vi. Reused of the existing circuit shall be on a separate DSP output zone, and allow
selective control of the use of, level and muting of these speakers by the Clerk’s control
panel.
vii. A 72-76MHz RF assisted listening transmitter and antenna, for ADA compliance, as well
as an associated ALS-over-Wi-Fi appliance to allow listening over smartphones and
earbuds using the guest network and associated app
viii. A pair of wall-mounted 98” Flat panel displays, behind the dais, in each corner for
display of content as selected by the Clerk using the room control system
ix. A pair of wall-mounted 75” Flat panel displays, one to each side of the audience area for
display of content as selected by the Clerk using the room control system, with the
ability to provide legibility for those in the audience furthest from the behind dais
displays.
x. A ceiling mounted video projector and motorized projection screen, for display of
program content when the room is being used for non-Council programs and events.
xi. Two (2) high-definition PTZ cameras, mounted at the front and rear of the room at the
base of the perimeter soffit, to capture wide views of the audience, and framed views of
the entire Council and City representatives.
xii. One (1) high-definition, high-performance PTZ camera, mounted in the (audience)
center-left portion of the room soffit, with the ability to auto-track speakers and audio
sources in the room and focus on those sources.
xiii. Bid Alternate ‘A’ - Replacement of existing 277 Volt and 120Volt dimming wall-
mounted light switches, with a simple lighting control system that allows remote control
of the circuit/zone switching of existing center fixtures, as well as dimming and switching
of perimeter recessed accent lighting.
c. The Existing AV Equipment Rack and IDF Room:
Page 269 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COUNCIL CHAMBERS AUDOIVISUAL SYSTEMS
27 41 20 - Page 4 of 9
i. The AV headend will be located in a new Owner Furnished (OFE) replacement AV rack,
and share space with the existing CATV ingest point and demarcation enclosure.
Contractor to coordinate turnover of rack from Owner, and transport to shop for
integration of equipment and required accessories.
ii. The AV headend will use existing pathway and electrical power.
d. The Existing Lobby and Building entry will include:
i. Reuse of existing speakers, speaker zone and amplifier circuits for selective overflow
audio into the Lobby space through the control system
ii. Reuse of existing speaker(s), speaker zone and switched amplifier circuit for
selective overflow/broadcast to the speaker(s) at the exterior entrance of the
building.
B. Display Systems
1. Provide and install a pair of 98” diagonal flat panel displays. Each display shall be mounted on
a bolt-down stand that will suspend the display in the corner behind the dais as close to the
underside of the perimeter soffit as possible while retaining serviceability. Supporting
infrastructure shall be located on the wall, centered behind each display. The supporting AV-
over-IP decoder shall be mounted to the backside of the display mount.
2. Provide and install a pair of 75” diagonal flat panel display at each side of the audience area,
as per the plan drawings. Each display shall be mounted on a low-profile mount to ensure the
total depth of the display from the wall is less than 4” in order to meet 2010 ADA. A recessed
service enclosure shall be provided behind each display to provide power/data connectivity as
well as the supporting AV-over-IP decoder.
3. Provide and install a ceiling mounted projector, suspended from a recessed projector service
enclosure and mount. Coordinate access to and modification of the existing ceiling space and
system with the Owner’s Project Manager. Verify specified lensing with field conditions and
confirm prior to procurement.
4. Provide and install a surface ceiling-mounted motorized tab-tensioned projection screen from
the angled face of the soffit at the front of the room as per the plan drawings. Provide
necessary extension 120V circuit to power the screen as well as projector. Provide all
necessary low-voltage control cabling and interface to the AV control system processor.
Provide and install mounting hardware to mount screen case to the angled surface of the soffit
and maintain the case’s and screen’s orientation plumb to the floor.
5. Provide and install 22” tabletop LCD monitor displays at the dais, as per the plans. Provide
desktop VESA mounts to allow the use of the monitors while minimizing the appearance of the
monitors from the audience view over the dais top.
C. Video Systems
1. Provide and integrate an HDMI distribution amplifier at the dais, within the dais millwork, to
provide signal to the 22” monitors at the dais.
2. Provide and integrate AV-over-IP decoder units at display devices as per the drawings.
Provide appropriate mounting to the millwork or display backing structure.
3. Provide and integrate AV-over-IP encoder/decoder units as per the drawings. Provide
integration of USB2.0 KVM or signal transport as per the drawings. Provide audio breakaway
routing to the decoder unit to be fed into the audio DSP as room program audio.
4. Provide and integrate AV-over-IP encoder units at source devices as per the drawings.
Provide appropriate mounting within dais millwork.
5. Provide and integrate an under-table 8x1 HDMI switcher at the dais to allow selection of HDMI
inputs at the dais table boxes to be sent to the encoder for display/recording.
6. Provide and integrate ceiling-mounted HD PTZ cameras in the ceiling soffits as per the RCP
drawings and schematics. Cameras shall provide output of HDMI, USB2.0/3.0 video and IP
H.264/AVC streaming content. H.264 content to be sent to a decoder for ingest to the
recording/streaming device, as well as to the CATV feed. Provide and integrate an active
USB3.0 extension cable to feed front of room camera content to the OFE PC at the dais, used
Page 270 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COUNCIL CHAMBERS AUDOIVISUAL SYSTEMS
27 41 20 - Page 5 of 9
for UC/Web-conferencing applications.
a. Provide and integrate camera control software client to enable auto-tracking camera
functions on the center camera of the room. Coordinate installation of software with Owner’s
IT management.
7. Provide and integrate a wireless presentation appliance to allow display of HD/UHD content
from a variety of user platforms over Wi-Fi, using an application, Apple Air-Play, Miracast,
Chromecast and other supported platforms. Coordinate provisioning of guest and/or
enterprise Wi-Fi integration with the Owner’s IT group.
8. Provide and integrate a recording and streaming appliance at the equipment rack, on a pull-out
rack shelf. The recording/streaming appliance shall provide two HDMI inputs for side-by-
side/PIP recording of two sources (typically content + video from the web-cam or camera feed
from CATV, as per the drawings), as well as audio. Recording shall be to an SD card slot.
Operation is through the device touch-panel display as well as a page in the control systems’
touchpanel to allow session record ‘start’, ‘stop’, ‘pause’, ‘write/save’, and playback
commands.
9. Provide and integrate an HDMI distribution amplifier at the rack to provide signal to the
recorder and feed to the converter supplying presentation content to CATV.
10. Provide and integrate an HDMI-to-3/12G-SDI converter to provide content to the CATV SD-
SDI ingest/transport interface. Coordinate provisioning with the Owner and CATV
representative.
11. Provide and integrate, at each dais input location, a ‘keyring’ of common adapters for use by
staff, as per Appendix ‘A’.
D. Audio Systems
1. Provide and integrate a conferencing microphone system of modular components that include:
a. Conference microphone base unit: Flush mount in the podium, without monitor speaker
b. Conference microphone base unit: Flush mount in the dais, with speaker for voice &
program reinforcement
c. Conference microphone gooseneck units, in 16” and 20” lengths, as per the drawings, for
use with the base units
d. Conference microphone modular interface: to connect base units to series transport to
Control Unit. Provide under-table mounting brackets to secure modules within dais
millwork/cabinets.
e. Conference microphone central control unit: with power supply, in equipment rack. To
provide input/output to/from the audio DSP for output to room speakers & audio feeds to
record/CVTV, as well as return mix-minus feeds to tabletop base unit speakers.
f. Provide and integrate using manufacturer shielded CAT6/6A cables or following
manufacturer requirements for use of 3rd party cabling.
2. Provide and integrate a system of surface ceiling-mounted beam-forming beam-tracking
microphones and AVB interface to audio DSP systems. Provide in-ceiling cabling and
infrastructure to connect microphones to power/interface unit, and from interface to equipment
rack network switch dedicated to AVB.
a. Provide and integrate extension microphone units as per plans and Appendix ‘A’.
3. Provide and integrate a system of digital FM RF wireless microphone systems as per the
drawings and Appendix ‘A’. System shall be a 500MHz range system with AES-256
encryption. Include all mounting accessories, RF distribution, antennae, lithium-ion batteries
and charging accessories. Provide wireless survey and frequency coordination plan as per
Section 27 41 00. Wireless mic system shall include:
a. Dedicated receiver system with belt-pack transmitter with lavaliere omnidirectional
capsule.
Page 271 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COUNCIL CHAMBERS AUDOIVISUAL SYSTEMS
27 41 20 - Page 6 of 9
b. Dedicated receiver system with handheld dynamic transmitters.
c. Dedicated receiver system with tabletop transmitter and 10” gooseneck microphones with
supercardioid elements.
d. Dedicated receiver system with tabletop boundary layer transmitters.
e. Dedicate tabletop plug-in battery charging system for transmitter bases and batteries.
f. Rackmount RF distribution amplifier, with power supply outputs, and cascade output to
feed additional DA’s.
g. Associated dipole antennae and mounting brackets for mounting of antenna above RF-
transparent suspended ceiling. Provide manufacturer recommended orientation for
polarization plane of transmitters used in the environment.
4. Provide and integrate a rackmount audio DSP processor as per the drawings and Appendix
‘A’. DSP shall provide 12x8 analog I/O, with AEC hardware on each input, both Ethernet and
AVB network connectivity, VoIP/SIP and POTS dialer interfaces. Provide integration to AVB
switch and associated AVB network equipment. Provide integration of SIP or POTS dialer and
coordinate with Owner’s IT group for provisioning of port(s)/line(s) for audio-conferencing.
5. Provide and integrate a rack-mounted audio distribution amplifier to provide split output fed to
both the in-room recording/streaming appliance, as well as to the back-wall media feed panels
and portable press box unit, as needed.
6. Provide and integrate a rack-mount audio power amplifier to drive the main reinforcement
speakers in the room. Amplifier shall be a two-channel, low-impedance type of 100 W per
channel. Include rack-mount kit.
7. Provide and integrate a pair of wall-mounted column loudspeakers with adjustable equalization
and vertical directivity curves for its application. Provide aiming bracket and locate as per the
drawings.
8. Ingrate existing ceiling speakers, amplifiers and zones to outputs from the DSP as per the
drawings. Verify function of existing hardware and adjust as needed. If non-functioning,
identify issues affecting function to the Owner and Consultant with suggestions for
remediation.
9. Provide and integrate an assistive listening system to meet ADA requirements for public
assembly areas. ALS system shall combine a FM transmitter and antenna with a
supplemental system using the guest Wi-Fi network for use by users with smartphones and
earbuds, using the manufacturer ‘app’. Coordinate provisioning on the guest network with the
Owner’s IT group. Provide kit with included IR receivers, earphones, T-coil inductive neck-
loops, rack-mount kit, and require signage/placards with access information.
10. Provide and install wall-plates to provide press-box feeds at rear of room in audience area.
Provide custom plates as per Appendix ‘A’ and drawings.
11. Provide and set up portable press-box. Press box to accept line-level output from wall plate
and provide transformer isolated mic-level outputs for feeds to public media.
12. Provide and integrate a USB3.0 active extension cable to provide feed from DSP unit to OFE
PC computer at dais used for UC/Web-conferencing. Provide configuration with DSP and
OFE PC to provide reliable, repeatable use of PC for UC conferencing within room.
E. Control Hardware
1. Provide and integrate a rack-mounted control system processor. Processor shall provide dual-
NIC interface to AV & Owner’s enterprise network, as well as multiple serial/com ports for RS-
232/422 device control, as well as contact/relays and 0-10 Volt I/O for future applications.
2. Provide and integrate a table-top 10” touchpanel control for use by the Clerk in running
systems. Touch-panel shall include tabletop kit.
3. Bid Alternate ‘A’ - Provide and integrate a hardware control interface for control of existing
lighting circuits. Lighting control systems shall be coordinated with the City Project Manager
and designated Electrician. Lighting controls shall include:
a. Wall mounted control interface and processor cabinet, to be located in the existing
electrical room adjacent to the panelboards serving 277V and 120V circuits.
Page 272 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COUNCIL CHAMBERS AUDOIVISUAL SYSTEMS
27 41 20 - Page 7 of 9
b. Wall or DIN-rail mounted 277V switched and 120V dimming modules for control of
respective circuits in the Chambers
c. Wall-mounted keypad controllers to replace existing 120V and 277V wall switches.
Coordinate provisioning of keypads and labels with Consultant and Owner through submittal
process.
4. Provide and integrate a rack-mounted L3 network switch for use with AV-over-IP transport, as
well as device control and monitoring. This switch shall be used for off-enterprise network
applications and will not be integrated into the Owner’s enterprise network. Switch shall be
stackable with 10GE SFP/SFP+ ports, and PoE/PoE+ ports with a power budget of 740 Watts
maximum, with at least 8 ports supporting 60W PoE applications.
5. Provide and integrate a stand-alone rack-mounted AVB switch for the integration of AVB
microphone systems with the DSP. Switch shall be a 5-port unit, with 1 port for gapped
network control/monitoring. Provide rack mount shelf or bracket to mount.
F. User Interface
1. Provide programming of control interfaces as directed by Owner’s Representative and
Consultant. Programming shall provide simple user interface to select local video and audio
sources and adjust room and area volume to within predetermined limit. Additional pages and
functions to include:
a. Control of main audio settings: Microphone levels – desktop & wireless, Speaker main
levels. (All other gain structure shall be auto-mix or tech-page only)
i. Control and muting of Conferencing Mics: Allow request to speak; Reject request to
speak; mute-all; allow-all
ii. Control of muting of other mic systems: wireless and ceiling
iii. Control of microphone routing to UC/Web-conference/Audio-conference: Ceiling,
Wireless Tabletop, Wireless HH/Lavaliere
b. Control of source switching to displays & CATV: Selection from, Wireless, Clerk Dais PC,
Clerk Laptop PC, Secretary HDMI in, Dais HDMI 1-7, Podium HDMI, Recorder
c. Control of PTZ cameras, including pan, tilt, zoom functions, auto-tracking, and no less than
four (4) presents, which shall include push-to-hold write for recall. Provide ability to name
presets for easy recall by the Clerk.
d. Control of recording/streaming appliance: New Recording, Start, Pause, Stop, Save/write.
Selection of input configuration:
i. Camera – USB or CATV feed
ii. Content – select displayed or (other)
iii. Image layout in stream/recording – PIP: Camera big/Content small, Content
big/Camera small; Side-by-Side
e. Per Bid Alternate ‘A’ - Control of room lighting: Broken down into scenes:
i. All on/off
ii. Council Meeting, with flat panel display usage
iii. Conference Call
iv. Projection
f. System startup/shutdown: with confirmation page.
2. Provide and program software management/monitoring interface for Owner’s technical staff,
which will allow advanced system control and monitoring functions using a PC connected to
the control system LAN.
Page 273 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COUNCIL CHAMBERS AUDOIVISUAL SYSTEMS
27 41 20 - Page 8 of 9
3. Provide control panel operations that are consistent from page to page.
4. Provide feedback that indicates the current equipment and/or system status where possible.
G. Software
1. Provide control capability for every function available on every piece of equipment being
controlled by the system. Define and provide “macro” commands for the most used functions.
2. Provide control capability to OFE Windows PC and tablet devices, by providing the appropriate
executable files and app deployment of the control system GUI for the space. Include all
necessary programming and licensing costs for this feature.
3. Provide password protection for any operations that can adversely affect certain room set-up
functions. Provide for the ability for remote monitoring of system functions and adjustments
via-TCP/IP. Capability for configuration will require password protection for use of facility
management. Provide for the delivery of email fault alerts to facility management.
H. The Contractor shall provide all interconnection cable, connectors, terminal strips, wireways,
flexible conduit, etc., to facilitate the audiovisual systems as detailed within these specifications
and drawings.
I. Miscellaneous
1. Integrate an existing OFE equipment rack as noted in the Appendix ‘A’ document and
drawings. Provide and integrate all required thermal management accessories, doors, side-
panels, top panels, bases, casters, blank and vent panels, lacing-bars, horizontal and vertical
wire management, and power distribution as required per the specifications and drawings, as
well as best practices defined by AVIXA, TIA/EIA, and BiCSi.
2. Provide and integrate power conditioning and distribution as required.
3. Provide and integrate a rack-mounted patch panel at the IP switch in the main AV rack to allow
patching and management of AV related IP devices in the rack.
4. Provide and integrate all rack specialty ventilated and pull-out shelves, drawers and foam
inserts for storage of microphones and transmitters as per appendix ‘A’. Provide all rack-
mount kits and shelves as required for the securement of AV equipment specified. No double-
sided tape, tie-wraps, or other adhesive methods shall be allowed to secure equipment that
does not confirm to standard TIA rack mount methods. All devices shall be installed in
standard rackmount hardware.
5. Provide and install all flush-mounted captive cable boxes in dais and podium as per the
drawings and Appendix ‘A’. Include US 120V receptacles and power supplies for USB-A and
USB-C power. Provide captive cables as specified in Appendix ‘A’.
6. Provide and install all hardware, cabling, connectors, faceplates, terminators, adapters, audio
combiners, balanced-unbalanced audio converters, wall boxes, etc. required to ensure
installation of a fully functional audiovisual system as depicted in the attached AV Systems
drawings.
1.4 EQUIPMENT LAYOUT
A. The equipment in this area shall be as detailed on drawings.
B. All equipment shall be installed with rack ears/mounts or custom rack-mounts/face-plates, using
security screws.
1.5 OWNER FURNISHED EQUIPMENT
A. All room furniture will be furnished by the Owner (Unless otherwise noted in this specification).
B. All Windows PC computers will be furnished by the Owner, along with wired and wireless
keyboard/mice/trackpads and monitors. All software and licensing for PC computers will be OFE.
Coordinate I/O connectivity requirements with Owner IT staff and provide any required adaptors,
baluns or interfaces.
C. Unless noted otherwise in Appendix ‘A’, All enterprise IP Network switches and Wi-Fi access
points (APs) will be furnished by the Owner. Coordinate switch allocation with owner as needed
and allowed by the Owner’s IT security representative.
Page 274 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
COUNCIL CHAMBERS AUDOIVISUAL SYSTEMS
27 41 20 - Page 9 of 9
1.6 RELATED WORK SPECIFIED ELSEWHERE
A. The following systems and equipment are not provided under this contract. The Contractor is to
coordinate with the base bid contractors as necessary to insure compatibility.
B. Telephone and telecommunications jacks and special telecom outlets not related directly to AV,
(LAN/WAN, Wireless access points (WAPs), PTSN/POTS, etc.).
PART 2 - PRODUCTS
2.1 APPROVED MANUFACTURERS
A. Included with Contract Documentation
1. Provide in accordance with Appendix ‘A’ – 27 41 20.
B. Pre-Approved Alternate Manufacturers
1. Provide in accordance with Section 27 41 00.
2.2 AUDIOVISUAL SYSTEMS HARDWARE & COMPONENTS
A. Provide in accordance with Appendix ‘A’ – 27 41 20, which includes the following:
1. Equipment description, including parameters and options required.
2. Manufacturer to be base-bid.
3. Model number of equipment or series to be bid.
4. Quantity of equipment, or reference to drawing quantities.
5. Designation of any Owner-Furnished (OFE), Existing to Reuse (ETR), Not-in-Contract (NIC) or
Future equipment.
6. Custom Quotation numbers, where applicable, to be bid as a pre-approved dealer or
representative of the manufacturer quoted.
PART 3 - EXECUTION
3.1 PROVIDE IN ACCORDANCE WITH SECTION 27 41 00 – AUDIOVISUAL SYSTEMS: PART 3 -
EXECUTION.
APPENDIX A – EQUIPMENT LISTS
See the attached Appendix for the equipment lists for the audiovisual systems. These lists are provided for
the bidding process.
END OF SECTION 274120
Page 275 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
CONFERENCE ROOM 3 AUDOIVISUAL SYSTEMS
27 41 30 - Page 1 of 4
SECTION 27 41 30 – CONFERENCE ROOM 3 AUDIOVISUAL SYSTEMS
PART 1 - GENERAL INFORMATION
1.1 OPERATIONAL SUMMARY & SCOPE
A. This section of the specification describes the functional details of the audiovisual systems to be
furnished and installed in Conference Room 3 of the Civic Center of the City of Ukiah.
B. The Systems in the Conference Room are to be a complete replacement of all systems
components, hardware, cabling, connectors and associated devices.
C. Events hosted in this space will include, but not be limited to:
1. City staff and management meetings – Internal meetings with audio-conferencing and web-
conferencing, using an Owner PC hosting UC software.
D. All systems shall be dedicated and permanently installed as described above and, in the following,
‘functional’ descriptions.
1.2 RELATED WORK
A. Installation of new or modified wall boxes, pathways, floor-box fittings (excluding any plates and
connectors to be provided by the contractor.
B. Telephone and telecommunications jacks and special telecom outlets not related directly to AV,
(LAN/WAN, Wireless access points (WAPs), PTSN/POTS, etc.).
C. Provide in accordance with Section 27 41 00 – Audiovisual Systems.
1.3 SYSTEM INTERCONNECTION & FUNCTIONAL DESCRIPTION
A. Functional intent
1. The Systems provided in the room, and general layout shall consist of the following locations
and associated functions:
a. A long rectangular conference room table, hosting up to 20 seats:
i. The table shall provide a recessed captive cable box with an HDMI, and USB and
120V power available for charging. The HDMI shall be fed to the display location in
the room via over-floor/under-carpet raceway. If necessary, this raceway shall
include channel to route 120V power from the wall at the display.
b. An existing castered credenza unit, which shall house and host most of the audiovisual
equipment serving the space – both on shelving and on the top surface.
c. A new wall mounted flat panel display and mount, along with stereo side-bar speakers, a
fixed zoomable web-conferencing camera, and a recessed in-wall backbox to host power,
data, and support devices behind the display mount.
d. A flush wall-mounted control panel, to provide basic display and device controls, including:
i. Power on/off
ii. Source input selection
iii. Audio volume up/down/mute
iv. Video muting
v. Microphone muting
e. A local PC, on the secure City enterprise network, to host City content as well as UC/Web-
conferencing software, and CivicPlus web-interface/client software
f. A UCC host interface, with HDMI pass-thru video and USB camera support, alongside a
set of beam-forming/beam-tracking ceiling pendant microphones for UCC conferencing and
Page 276 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
CONFERENCE ROOM 3 AUDOIVISUAL SYSTEMS
27 41 30 - Page 2 of 4
streaming/recording capture.
g. Wireless presentation appliance, for presentation of content over Wi-Fi from user devices,
including Windows, OSX, iOS, Android, Chromecast and others.
B. Display Systems
1. Provide and install a 75” diagonal flat panel display as per the plan drawings. A recessed
service enclosure shall be provided behind the display to provide power/data connectivity.
C. Video Systems
1. Provide and integrate an HDMI distribution amplifier to split signal between the display and
streaming encoder/recorder interfacing to the CivicPlus platform.
2. Provide and integrate a small integrated HD-Base-T/HDMI switcher at the credenza to allow
selection of HDMI input(s) at the table box to be sent to the display/recording.
3. Provide and integrate a small HD-Base-T transmitter at the table box to allow HDMI
connection to the display/credenza.
4. Provide and integrate a fixed zoomable camera at the display, above the credenza. Cameras
shall provide output of HDMI and USB 3.0 interface at the credenza unit.
5. Provide and integrate a wireless presentation appliance to allow display of HD/UHD content
from a variety of user platforms over Wi-Fi, using an application, Apple Air-Play, Miracast,
Chromecast and other supported platforms. Coordinate provisioning of guest and/or
enterprise Wi-Fi integration with the Owner’s IT group.
6. Provide and integrate a recording and streaming appliance at the credenza unit, The
recording/streaming appliance shall provide two HDMI inputs for side-by-side/PIP recording of
two sources as well as audio. Recording shall be to an SD card slot. Operation is through the
device touch-panel display as well as a page in the control systems’ touchpanel to allow
session record ‘start’, ‘stop’, ‘pause’, ‘write/save’, and playback commands.
D. Audio Systems
1. Provide and integrate a unified-conferencing & collaboration interface which consists of a host
unit that provides HDMI pass-thru input as well as dual HDMI outputs to displays, USB3.0 host
interface for a PC or laptop client UC software host, USB3.0/2.0 connections to host a USB
conferencing camera, input for ceiling/table microphones for conferencing use, and network
connectivity for control and management of the unit. UCC interface shall also include:
2. Provide and integrate a system of pendant ceiling-mounted beam-forming beam-tracking
microphones and interface to the UCC interface. Provide in-ceiling cabling and infrastructure
to connect microphones to the UCC interface.
a. Provide and integrate extension microphone unit as per plans and Appendix ‘A’.
3. Provide and integrate a pair of display-mounted custom-height “soundbar” type column
loudspeakers at the display. Provide necessary mounting hardware to install to display VESA
mount.
E. Control Hardware
1. Provide and integrate a wall-mounted button control panel with integral control system
processor. Processor shall provide IP network interface to AV network, as well as a serial/com
ports for RS-232/422 device control, as well as contact/relays and 0-10 Volt I/O for future
applications.
a. Button panel shall provide a minimum of 8 assignable keys, with custom printed labels to
match functions as noted in 1.3.A.1.d above. Button panel shall also feature a rotary
encoder for control of audio volume levels.
2. Provide and integrate a small L2/L3 network switch for use with AV-over-IP transport, as well
as device control and monitoring. This switch shall be used for off-enterprise network
applications and will not be integrated into the Owner’s enterprise network. Switch shall
include two 10GE SFP/SFP+ ports, and PoE/PoE+ ports with a power budget of 60 Watts.
Page 277 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
CONFERENCE ROOM 3 AUDOIVISUAL SYSTEMS
27 41 30 - Page 3 of 4
F. User Interface
1. Provide programming of control interfaces as directed by Owner’s Representative and
Consultant. Programming shall provide simple user interface to select local video and audio
sources and adjust room and area volume to within predetermined limit. Additional pages and
functions to include:
a. Control functions as outlined in 1.3.A.1.d above.
2. Provide and program software management/monitoring interface for Owner’s technical staff,
which will allow advanced system control and monitoring functions using a PC connected to
the control system LAN.
3. Provide control panel operations that are consistent from page to page.
4. Provide feedback that indicates the current equipment and/or system status where possible.
G. Software
1. Provide control capability for every function available on every piece of equipment being
controlled by the system. Define and provide “macro” commands for the most used functions.
2. Provide control capability to OFE Windows PC and tablet devices, by providing the appropriate
executable files and app deployment of the control system GUI for the space. Include all
necessary programming and licensing costs for this feature.
3. Provide password protection for any operations that can adversely affect certain room set-up
functions. Provide for the ability for remote monitoring of system functions and adjustments
via-TCP/IP. Capability for configuration will require password protection for use of facility
management. Provide for the delivery of email fault alerts to facility management.
H. The Contractor shall provide all interconnection cable, connectors, terminal strips, wireways,
flexible conduit, etc., to facilitate the audiovisual systems as detailed within these specifications
and drawings.
I. Miscellaneous
1. Provide and integrate equipment into existing Owner-furnished (OFE) credenza unit. Provide
any and all necessary mounting accessories and/or supporting hardware and cable
management necessary to ensure a clean, organized and secure installation, which will allow
servicing and support by the Owner.
2. Provide and integrate power conditioning and distribution as required.
3. Provide and install all flush-mounted captive cable boxes in dais and podium as per the
drawings and Appendix ‘A’. Include US 120V receptacles and power supplies for USB-A and
USB-C power. Provide captive cables as specified in Appendix ‘A’.
4. Provide and install all hardware, cabling, connectors, faceplates, terminators, adapters, audio
combiners, balanced-unbalanced audio converters, wall boxes, etc. required to ensure
installation of a fully functional audiovisual system as depicted in the attached AV Systems
drawings.
1.4 EQUIPMENT LAYOUT
A. The equipment in this area shall be as detailed on drawings.
B. All equipment shall be installed with rack ears/mounts or custom rack-mounts/face-plates, using
security screws.
1.5 OWNER FURNISHED EQUIPMENT
A. All room furniture will be furnished by the Owner (Unless otherwise noted in this specification).
B. All Windows PC computers will be furnished by the Owner, along with wired and wireless
keyboard/mice/trackpads and monitors. All software and licensing for PC computers will be OFE.
Coordinate I/O connectivity requirements with Owner IT staff and provide any required adaptors,
baluns or interfaces.
C. Unless noted otherwise in Appendix ‘A’, All enterprise IP Network switches and Wi-Fi access
points (APs) will be furnished by the Owner. Coordinate switch allocation with owner as needed
Page 278 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
CONFERENCE ROOM 3 AUDOIVISUAL SYSTEMS
27 41 30 - Page 4 of 4
and allowed by the Owner’s IT security representative.
1.6 RELATED WORK SPECIFIED ELSEWHERE
A. The following systems and equipment are not provided under this contract. The Contractor is to
coordinate with the base bid contractors as necessary to insure compatibility.
B. Telephone and telecommunications jacks and special telecom outlets not related directly to AV,
(LAN/WAN, Wireless access points (WAPs), PTSN/POTS, etc.).
PART 2 - PRODUCTS
2.1 APPROVED MANUFACTURERS
A. Included with Contract Documentation
1. Provide in accordance with Appendix ‘A’ – 27 41 30.
B. Pre-Approved Alternate Manufacturers
1. Provide in accordance with Section 27 41 00.
2.2 AUDIOVISUAL SYSTEMS HARDWARE & COMPONENTS
A. Provide in accordance with Appendix ‘A’ – 27 41 30, which includes the following:
1. Equipment description, including parameters and options required.
2. Manufacturer to be base-bid.
3. Model number of equipment or series to be bid.
4. Quantity of equipment, or reference to drawing quantities.
5. Designation of any Owner-Furnished (OFE), Existing to Reuse (ETR), Not-in-Contract (NIC) or
Future equipment.
6. Custom Quotation numbers, where applicable, to be bid as a pre-approved dealer or
representative of the manufacturer quoted.
PART 3 - EXECUTION
3.1 PROVIDE IN ACCORDANCE WITH SECTION 27 41 00 – AUDIOVISUAL SYSTEMS: PART 3 -
EXECUTION.
APPENDIX A – EQUIPMENT LISTS
See the attached Appendix for the equipment lists for the audiovisual systems. These lists are provided for
the bidding process.
END OF SECTION 274130
Page 279 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
CONFERENCE ROOM 5 AUDOIVISUAL SYSTEMS
27 41 35 - Page 1 of 4
SECTION 27 41 35 – CONFERENCE ROOM 5 AUDIOVISUAL SYSTEMS
PART 1 - GENERAL INFORMATION
1.1 OPERATIONAL SUMMARY & SCOPE
A. This section of the specification describes the functional details of the audiovisual systems to be
furnished and installed in Conference Room 5 of the Civic Center Annex building of the City of
Ukiah.
B. The Systems in the Conference Room are to be a complete replacement of all systems
components, hardware, cabling, connectors and associated devices.
C. Events hosted in this space will include, but not be limited to:
1. City staff and management meetings – Internal meetings with audio-conferencing and web-
conferencing, using an Owner PC hosting UC software.
D. All systems shall be dedicated and permanently installed as described above and, in the following,
‘functional’ descriptions.
1.2 RELATED WORK
A. Installation of new or modified wall boxes, pathways, floor-box fittings (excluding any plates and
connectors to be provided by the contractor.
B. Telephone and telecommunications jacks and special telecom outlets not related directly to AV,
(LAN/WAN, Wireless access points (WAPs), PTSN/POTS, etc.).
C. Provide in accordance with Section 27 41 00 – Audiovisual Systems.
1.3 SYSTEM INTERCONNECTION & FUNCTIONAL DESCRIPTION
A. Functional intent
1. The Systems provided in the room, and general layout shall consist of the following locations
and associated functions:
a. A square or circular conference room table, hosting up to 8-10 seats:
i. The table shall provide a centered recessed captive cable box with an HDMI, and
USB and 120V power available for charging. The HDMI shall be fed to the display
location in the room via over-floor/under-carpet raceway. If necessary, this raceway
shall include channel to route 120V power from the wall at the display.
b. An existing castered credenza unit, which shall house and host most of the audiovisual
equipment serving the space – both on shelving and on the top surface.
c. A new wall mounted flat panel display and mount, along with stereo side-bar speakers, a
fixed zoomable web-conferencing camera, and a recessed in-wall backbox to host power,
data, and support devices behind the display mount.
d. A flush wall-mounted control panel, to provide basic display and device controls, including:
i. Power on/off
ii. Source input selection
iii. Audio volume up/down/mute
iv. Video muting
v. Microphone muting
e. A local PC, on the secure City enterprise network, to host City content as well as UC/Web-
conferencing software, and CivicPlus web-interface/client software
f. A UCC host interface, with HDMI pass-thru video and USB camera support, alongside a
Page 280 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
CONFERENCE ROOM 5 AUDOIVISUAL SYSTEMS
27 41 35 - Page 2 of 4
set of beam-forming/beam-tracking ceiling pendant microphones for UCC conferencing and
streaming/recording capture.
g. Wireless presentation appliance, for presentation of content over Wi-Fi from user devices,
including Windows, OSX, iOS, Android, Chromecast and others.
B. Display Systems
1. Provide and install a 65” diagonal flat panel display as per the plan drawings. A recessed
service enclosure shall be provided behind the display to provide power/data connectivity.
C. Video Systems
1. Provide and integrate an HDMI distribution amplifier to split signal between the display and
streaming encoder/recorder interfacing to the CivicPlus platform.
2. Provide and integrate a small integrated HD-Base-T/HDMI switcher at the credenza to allow
selection of HDMI input(s) at the table box to be sent to the display/recording.
3. Provide and integrate a small HD-Base-T transmitter at the table box to allow HDMI
connection to the display/credenza.
4. Provide and integrate a fixed zoomable camera at the display, above the credenza. Cameras
shall provide output of HDMI and USB 3.0 interface at the credenza unit.
5. Provide and integrate a wireless presentation appliance to allow display of HD/UHD content
from a variety of user platforms over Wi-Fi, using an application, Apple Air-Play, Miracast,
Chromecast and other supported platforms. Coordinate provisioning of guest and/or
enterprise Wi-Fi integration with the Owner’s IT group.
6. Provide and integrate a recording and streaming appliance at the credenza unit, The
recording/streaming appliance shall provide two HDMI inputs for side-by-side/PIP recording of
two sources as well as audio. Recording shall be to an SD card slot. Operation is through the
device touch-panel display as well as a page in the control systems’ touchpanel to allow
session record ‘start’, ‘stop’, ‘pause’, ‘write/save’, and playback commands.
D. Audio Systems
1. Provide and integrate a unified-conferencing & collaboration interface which consists of a host
unit that provides HDMI pass-thru input as well as dual HDMI outputs to displays, USB3.0 host
interface for a PC or laptop client UC software host, USB3.0/2.0 connections to host a USB
conferencing camera, input for ceiling/table microphones for conferencing use, and network
connectivity for control and management of the unit. UCC interface shall also include:
2. Provide and integrate a system of pendant ceiling-mounted beam-forming beam-tracking
microphones and interface to the UCC interface. Provide in-ceiling cabling and infrastructure
to connect microphones to the UCC interface.
3. Provide and integrate a pair of display-mounted custom-height “soundbar” type column
loudspeakers at the display. Provide necessary mounting hardware to install to display VESA
mount.
E. Control Hardware
1. Provide and integrate a wall-mounted button control panel with integral control system
processor. Processor shall provide IP network interface to AV network, as well as a serial/com
ports for RS-232/422 device control, as well as contact/relays and 0-10 Volt I/O for future
applications.
a. Button panel shall provide a minimum of 8 assignable keys, with custom printed labels to
match functions as noted in 1.3.A.1.d above. Button panel shall also feature a rotary
encoder for control of audio volume levels.
2. Provide and integrate a small L2/L3 network switch for use with AV-over-IP transport, as well
as device control and monitoring. This switch shall be used for off-enterprise network
applications and will not be integrated into the Owner’s enterprise network. Switch shall
include two 10GE SFP/SFP+ ports, and PoE/PoE+ ports with a power budget of 60 Watts.
F. User Interface
Page 281 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
CONFERENCE ROOM 5 AUDOIVISUAL SYSTEMS
27 41 35 - Page 3 of 4
1. Provide programming of control interfaces as directed by Owner’s Representative and
Consultant. Programming shall provide simple user interface to select local video and audio
sources and adjust room and area volume to within predetermined limit. Additional pages and
functions to include:
a. Control functions as outlined in 1.3.A.1.d above.
2. Provide and program software management/monitoring interface for Owner’s technical staff,
which will allow advanced system control and monitoring functions using a PC connected to
the control system LAN.
3. Provide control panel operations that are consistent from page to page.
4. Provide feedback that indicates the current equipment and/or system status where possible.
G. Software
1. Provide control capability for every function available on every piece of equipment being
controlled by the system. Define and provide “macro” commands for the most used functions.
2. Provide control capability to OFE Windows PC and tablet devices, by providing the appropriate
executable files and app deployment of the control system GUI for the space. Include all
necessary programming and licensing costs for this feature.
3. Provide password protection for any operations that can adversely affect certain room set-up
functions. Provide for the ability for remote monitoring of system functions and adjustments
via-TCP/IP. Capability for configuration will require password protection for use of facility
management. Provide for the delivery of email fault alerts to facility management.
H. The Contractor shall provide all interconnection cable, connectors, terminal strips, wireways,
flexible conduit, etc., to facilitate the audiovisual systems as detailed within these specifications
and drawings.
I. Miscellaneous
1. Provide and integrate equipment into existing Owner-furnished (OFE) credenza unit. Provide
any and all necessary mounting accessories and/or supporting hardware and cable
management necessary to ensure a clean, organized and secure installation, which will allow
servicing and support by the Owner.
2. Provide and integrate power conditioning and distribution as required.
3. Provide and install all flush-mounted captive cable boxes in dais and podium as per the
drawings and Appendix ‘A’. Include US 120V receptacles and power supplies for USB-A and
USB-C power. Provide captive cables as specified in Appendix ‘A’.
4. Provide and install all hardware, cabling, connectors, faceplates, terminators, adapters, audio
combiners, balanced-unbalanced audio converters, wall boxes, etc. required to ensure
installation of a fully functional audiovisual system as depicted in the attached AV Systems
drawings.
1.4 EQUIPMENT LAYOUT
A. The equipment in this area shall be as detailed on drawings.
B. All equipment shall be installed with rack ears/mounts or custom rack-mounts/face-plates, using
security screws.
1.5 OWNER FURNISHED EQUIPMENT
A. All room furniture will be furnished by the Owner (Unless otherwise noted in this specification).
B. All Windows PC computers will be furnished by the Owner, along with wired and wireless
keyboard/mice/trackpads and monitors. All software and licensing for PC computers will be OFE.
Coordinate I/O connectivity requirements with Owner IT staff and provide any required adaptors,
baluns or interfaces.
C. Unless noted otherwise in Appendix ‘A’, All enterprise IP Network switches and Wi-Fi access
points (APs) will be furnished by the Owner. Coordinate switch allocation with owner as needed
and allowed by the Owner’s IT security representative.
Page 282 of 390
City of Ukiah California ABD Project #P2703 February 28, 2020
Council Chambers AV Replacement
City of Ukiah
Issued for Bid
CONFERENCE ROOM 5 AUDOIVISUAL SYSTEMS
27 41 35 - Page 4 of 4
1.6 RELATED WORK SPECIFIED ELSEWHERE
A. The following systems and equipment are not provided under this contract. The Contractor is to
coordinate with the base bid contractors as necessary to insure compatibility.
B. Telephone and telecommunications jacks and special telecom outlets not related directly to AV,
(LAN/WAN, Wireless access points (WAPs), PTSN/POTS, etc.).
PART 2 - PRODUCTS
2.1 APPROVED MANUFACTURERS
A. Included with Contract Documentation
1. Provide in accordance with Appendix ‘A’ – 27 41 35.
B. Pre-Approved Alternate Manufacturers
1. Provide in accordance with Section 27 41 00.
2.2 AUDIOVISUAL SYSTEMS HARDWARE & COMPONENTS
A. Provide in accordance with Appendix ‘A’ – 27 41 35, which includes the following:
1. Equipment description, including parameters and options required.
2. Manufacturer to be base-bid.
3. Model number of equipment or series to be bid.
4. Quantity of equipment, or reference to drawing quantities.
5. Designation of any Owner-Furnished (OFE), Existing to Reuse (ETR), Not-in-Contract (NIC) or
Future equipment.
6. Custom Quotation numbers, where applicable, to be bid as a pre-approved dealer or
representative of the manufacturer quoted.
PART 3 - EXECUTION
3.1 PROVIDE IN ACCORDANCE WITH SECTION 27 41 00 – AUDIOVISUAL SYSTEMS: PART 3 -
EXECUTION.
APPENDIX A – EQUIPMENT LISTS
See the attached Appendix for the equipment lists for the audiovisual systems. These lists are provided for
the bidding process.
END OF SECTION 274135
Page 283 of 390
CITY OF UKIAH ORDER NO. 1
CONTRACT CHANGE ORDER DATE: February 9, 2021
Contract for (Description of Facility): Council Chamber AV Replacement, Spec. No. 20-09
Owner: City of Ukiah, 300 Seminary Avenue, Ukiah, California, 95482-5400
To: (Contractor):EIDIM Group, Inc. dba EIDIM AV Technology,6905 Oslo Cir. Suite J, Buena Park, CA 90621
You are hereby directed to make the herein described changes from the contract plans and specifications or do the following described
work not included in the contract plans and specifications:
Change requested by: City Project Manager
Justification (Detailed and Concise): Please see above.
The amount of the Contract will be (decreased/increased/unchanged) by the estimated sum of: N/A.
The contract total including this and previous Change Orders will be: two hundred seventy-nine thousand seven hundred seventy
dollars and forty-three cents. ($279,770.43).
The contract period provided for completion will be (increased/decreased/unchanged):91 calendar days.
This document will become a supplement to the contract and all provisions will apply hereto.
Approved By:__________________________________
(City)Date
Accepted: ______________________________________
(Contractor)Date
This information will be issued as a record of any changes to the original construction contract.
Description of Changes - Itemized Breakdown
ESTIMATED
DECREASE To
Contract Amount
ESTIMATED
INCREASE To
Contract Amount
1. Add additional 91calendar days to the contract due to delays in material deliveries as a
consequence of COVID-19. As a result, the new deadline to complete the project is March
15, 2021.
N/A N/A
ESTIMATED NET CHANGE IN CONTRACT PRICE N/A
2/12/2021Timothy Pak Digitally signed by Timothy Pak
DN: cn=Timothy Pak, o=EIDIM Group, Inc., ou,
email=tim.pak@eidim.com, c=US
Date: 2021.02.12 10:33:38 -08'00'
2/15/2021
ATTACHMENT 2
Page 284 of 390
ATTACHMENT 3
Page 285 of 390
Estimate
Estimate D...
8/2/2021
Estimate #
4963 rev.2
Name / Address
City of Ukiah
300 Seminary Avenue
Ukiah, California 95482-5400
Ship To
City of Ukiah
300 Seminary Avenue
Ukiah, California 95482-5400
Terms
Net 30
Rep
AVA
Account #
20200917
FOB
Signature
E-mail
contact@eidim.com
Web Site
www.eidim.com
Total
Subtotal
Sales Tax (8.875%)
Tel. (877) 773-4346
Fax. (562) 777-9120
6905 Oslo Circle Ste J
Buena Park, CA 90621
Item DescriptionQty TotalCost
** Change Order - Airflow Fan & Rack Installation **
Accessories USB Powered d 4.5” x 4.5” Quiet Fan, UL Certified1 30.00T30.00
Accessories Ventilation Grille1 20.00T20.00
Accessories USB Charger1 11.00T11.00
Rack [Monoprice] 4U Wall Mounted Vertical Rack2 190.00T95.00
Accessories [Middle Atlantic] UTR1, 1U Half-Rack6 270.00T45.00
Installation Installation1 1,025.001,025.00
Shipping Charges Shipping Fee1 125.00125.00
_____________________________________
*Customer must pre-pay full cost of the equipments in advance. Price valid for 30 days.
1. No patching, conduit, or painting and etc. will be included unless indicated in writing.
2. Depends on availability of the parts, it may take up to 3 weeks for the parts to arrive at the job site.
3. Customer must pay for all additional equipments: parts & accessories that are not in the invoice,
result from change of order, typing error and accidental omission.
4. Customer must pay 35% restocking charge in case of exchage & return of item.
5. 4% Transaction Fee will be charged for Credit Card Transaction
$1,717.24
$1,671.00
$46.24
Page 286 of 390
7
KEY FEATURES
ANTI-VIBRATION SILICONE
Specially designed rubber
feet helps keep the noise level
down when the fan is vibrating
against a hard surface.
SPEED CONTROLLER
A speed controller located on
the cord permits you to
adjusts the fan’s speed and
power off the fan.
DUAL FAN GUARDS
Guards creates a barrier
between a fan’s blades and
any foreign objects it may
come into contact with.
DUAL BALL BEARINGS
Allows the fan unit to be
powered by a standard USB
port, a common power source
in home electronics.
ADDITIONAL USB PORT
Each fan contains an USB
port. Up to four fans can be
powered through a single USB
or outlet source.
USB CONNECTOR
Allows the fan unit to be
powered by a standard USB
port, a common power source
in home electronics.
Page 287 of 390
8
PRODUCT CONTENTS
MULTIFAN S1
MULTIFAN S3
MULTIFAN S4
MULTIFAN S3-P
AI-MPF80A
AI-MPF120A
AI-MPF140A
AI-MPF120P
(1) Single USB fan with Speed Controlller
Model AI-MPF120P contains Turbo Power Adapter
MULTIFAN S5
MULTIFAN S7
MULTIFAN S7-P
AI-MPF80A2
AI-MPF120A2
AI-MPF120P2
(1) Dual USB Fans with Speed Controller
Model AI-MPF120P2 contains Turbo Power Adapter
MULTIFAN S2 AI-MPB140A
(1) Single USB Blower with Speed Controller
MULTIFAN MINI AI-MPF40A
(1) Single USB Mini Fan with Speed Controller
Page 288 of 390
Page 289 of 390
Page 290 of 390
Page 291 of 390
U Series - Universal rackshelves with solid and vented construction
• Available in 1 through 4 rackspaces
• Weight capacity from 35 to 85 lbs. depending on size
• Accommodates most standard non-rackmountable components
• See chart for part numbers and dimensions
• Contractor packs available
U317 - Vented 3 space rackshelf
• 17- 3/4” depth allows for deeper components
• 60 lb. weight capacity
• Vent pattern provides air circulation
• Slotted rear flange for cable management
UTR1 - Half / third rack shelf
• 25 lb. weight capacity
• Generous vent pattern provides superior air circulation
• Hook & loop strips included for mounting any half or third space
components without hardware
• Contractor packs available
96
-
0
4
7
/
r
e
v
d
/
5
-
8
-
2
0
/
U
S
e
r
i
e
s
/
U
3
1
7
/
U
T
R
1
R
a
c
k
s
h
e
l
v
e
s
U Series
EIA/TIA compliant 19” solid, one-piece 16-gauge steel rackshelf shall be Middle Atlantic Products
model # Ux (x = # of rackspaces, refer to chart). Weight capacity shall be__(refer to chart).
Rackshelf shall feature durable flat black powder coat finish. Contractor packs shall be available
with twelve U1 or six U2 rackshelves and shall be model # U1-RP12 or U2-RP6. U series
rackshelf shall be UL Listed in the US and Canada. U Series shall be GREENGUARD Indoor Air
Quality Certified for Children and Schools. U series shall be manufactured by an ISO 9001 and ISO
14001 registered company.U series rackshelf shall be warrantied to be free from defects
in material or workmanship under normal use and conditions for the lifetime of the product.
U Series, Vented
EIA/TIA compliant 19” solid, one-piece 16-gauge steel rackshelf shall be Middle Atlantic Products
model # UxV (x=# of rackspaces, refer to chart) and shall have a ventilated bottom and sides.
Weight capacity shall be__(r efer to chart). Rackshelf shall feature durable flat black powder coat
finish. Vented U series rackshelf shall be GREENGUARD Indoor Air Quality Certified for Children
and Schools. Vented U series rackshelf shall be manufactured by an ISO 9001 and ISO 14001
registered company. Vented U series rackshelf shall be warrantied to be free from defects in
material or workmanship under normal use and conditions for the lifetime of the product.
U2
U Series / U317 / UTR1 Rackshelves
U317
UTR1
U4V
U317
EIA/TIA compliant 19” vented three rackspace rackshelf shall be Middle Atlantic Products
model # U317. One-piece, 16-gauge rackshelf shall provide a 60 lb. weight capacity. U317
shall features slotted rear flange for cable management. Depth of 17-3/4” shall accommodate
deeper components. U317 shall be GREENGUARD Indoor Air Quality Certified for Children
and Schools. U317 shall be manufactured by an ISO 9001 and ISO 14001 registered company.
U317 shall be warrantied to be free from defects in material or workmanship under normal
use and conditions for the lifetime of the product.
UTR1
EIA/TIA compliant 19” half / third rack shelf with 10" depth shall be Middle Atlantic Products
model # UTR1. Weight capacity shall be 25 lbs. UTR1 shall include two 2” x 10” hook &
loop strips for component mounting and a generous vent pattern for superior air circulation.
Contractor packs shall be available with twelve UTR1 rackshelves and shall be model
# UTR1-RP12. UTR1 shall be GREENGUARD Indoor Air Quality Certified for Children and
Schools. UTR1 shall be manufactured by an ISO 9001 and ISO 14001 registered company. UTR1 shall
be warrantied to be free from defects in material or workmanship under normal use and
conditions for the lifetime of the product.
EXCEPTIONAL SUPPORT & PROTECTION™
CUSTOMIZABLE SPECIFICATION CLIPS AVAILABLE AT MIDDLEATLANTIC .COM
Features
US: New Jersey • California • Illinois • Voice: 973-839-1011 Fax: 973-839-1976 • middleatlantic.com
Canada: Ontario • British Columbia • Voice: 613-836-2501 Fax: 613-836-2690 • middleatlantic.ca
Architects’ and Engineers’ Specifications
U Series/U317/UTR1 Rackshelves
EIA/TIA Compliant
Page 292 of 390
U Series
U317 UTR1
U Series/Vented U Series/U317/UTR1 basic dimensions
All dimensions in inches unless otherwise noted [Bracketed dimensions in millimeters]
US: New Jersey • California • Illinois • Voice: 973-839-1011 Fax: 973-839-1976 • middleatlantic.com
Canada: Ontario • British Columbia • Voice: 613-836-2501 Fax: 613-836-2690 • middleatlantic.ca
PART #
1 piece
PART #
4 pieces
RACKING
HEIGHT/
RACKSPACES
“A”
OVERALL
DEPTH
“B”
USEABLE
DEPTH
“C”
WEIGHT
CAPACITY
U1V U1V-4 1.75 [44] (1 SP)10.78 [274]10.41 [264]35 lbs. [16 kg]
U2V U2V-4 3.50 [89] (2 SP)15.375 [390]15.00 [381]50 lbs. [23 kg]
U3V U3V-4 5.25 [133] (3 SP)15.375 [390]15.00 [381]70 lbs. [32 kg]
U4V U4V-4 7.00 [178] (4 SP)15.875 [403]15.50 [394]85 lbs. [39 kg]
Middle Atlantic Products, Inc.Middle Atlantic Products
®
A
B
D
17.56 [446]
17.38 [441]
.56 [14]
(rear flange)
TOP
VIEW
FRONT VIEW
SIDE
VIEW
.31 [8] front flange
on U2, U3 and U4 only
C
17.50 [445]
10.00
[254]
19.00 [483]
1.72 [44]
TOP
VIEW
FRONT
VIEW
17.38 [441]
.31 [8] (front flange)
5.25
[133]
.63 [16]
(rear flange)
5.25
[133]
5.00
[127]
.31 [8] (rear flange depth)
17.75
[451]
useable
depth
17.86
[454]
overall
depth
TOP
VIEW
SIDE
VIEW
FRONT
VIEW
PART #
RACKING HEIGHT /
RACKSPACES
“A”
OVERALL
DEPTH
“B”
USEABLE
DEPTH
“C”“D”
WEIGHT
CAPACITY
U1 1.75 [44] (1 SP)10.78 [274]10.72 [272]6.05 [154]35 lbs. [16 kg]
U2 3.50 [89] (2 SP)14.55 [370]14.43 [367]6.49 [165]50 lbs. [23 kg]
U3 5.25 [133] (3 SP)14.55 [370]14.43 [367]5.71 [145]70 lbs. [32 kg]
U4 7.00 [178] (4 SP)15.50 [394]15.38 [391]6.00 [152]85 lbs. [39 kg]
.375 [10]
B
USABLE
DEPTH
17.44 [443]
.437 [11]
rear flange
SIDE
VIEWA
19.00 [483]
.313 [8]
front flange
Vented U Series
TOP
VIEW
FRONT
VIEW
Page 293 of 390
CONSTRUCTION CONTRACTORS ESTIMATE OF COST (FOR CHANGE ORDER)Ref.: EST 4963 rev.2
RFP --
City of Ukiah - Conference Room #3 / Airflow installation
CONTRACT NO.:
Prime Contractor:EIDIM AV Technology * th = Technician Hour
* ah = Administrator Hours
LABOR MATERIAL EQUIPMENT
NO.ITEM DESCRIPTION QTY UNIT Un. Cost Ttl Cost Un. Cost Ttl Cost Un. Cost Ttl Cost
Administrative Work
1 Processing of Submittals 2 mh 45.00 90.00 0.00 0.00
2 Catalog Change 0 mh 45.00 0.00 0.00 0.00
3 Scheduling 0 mh 45.00 0.00 0.00
4 As-built 0 mh 45.00 0.00 0.00 0.00
5 Reprographics 0 sf 0.00 0.15 0.00 0.00
6 0.00 0.00 0.00
Prime Contractor's Work Totals 90.00 0.00 0.00
Technical Work QTY UNIT Un. Cost Ttl Cost Un. Cost Ttl Cost Un. Cost Ttl Cost
7 1 ls 0.00 0.00
8 1 th 45.00 45.00 0.00 0.00
9 0 th 45.00 0.00 0.00 0.00
10 2 ah 45.00 90.00 0.00 0.00
11 Submittal preparation, new equipment 0 th 45.00 0.00 0.00 0.00
12 N/A 0 ah 45.00 0.00 0.00 0.00
13 Engineering, new equipment 0 th 65.00 0.00 0.00 0.00
14 0 ea 0.00 0.00 0.00 0.00
14 0 mh 45.00 0.00 0.00 0.00
15 1 ea 34.00 34.00 0.00 0.00 0.00
0.00 0.00 0.00
0.00 0.00 0.00
16 8 mh 60.00 480.00 0.00 0.00
17 0 mh 65.00 0.00 0.00 0.00
18 0 ea 650.00 0.00 0.00 0.00
19 4 55.00 220.00 0.00 0.00
20 0 mh 55.00 0.00 0.00 0.00
21 0 lot 25.00 0.00 0.00 0.00
22 0 Lot 55.00 0.00 0.00 0.00
23 0 Lot 0.00 0.00 0.00 0.00
24 260 mile 0.60 156.00 0.00 0.00
Technical Work Totals 1,025.00 61.00 0.00
Traveling (includes lodging and food)
Traveling (Miles) - Round Trip
Shipping
Field install of added components not part
of original equipment list
Field R&R Existing Infrastructure
Onsite Training
Warranty (Equipment) -
Shop Install, Added Equipment
Cables, parts, accessories
Shop Labor
Field Install, Added Equipment
Programming
Equipment Rental - Lift, Scaffold, Ladder or
others
Please see EST #4963 -
Prepare new equipment quote sheets
Buyout for new equipment
Purchase orders and admin for new
equipment
Warranty (Tech support - email, call, onsite
Support
Page 294 of 390
ATTACHMENT 4
Page 295 of 390
Estimate
Estimate D...
12/7/2021
Estimate #
5060
Name / Address
City of Ukiah
300 Seminary Avenue
Ukiah, California 95482-5400
Ship To
City of Ukiah
300 Seminary Avenue
Ukiah, California 95482-5400
Terms
Net 30
Rep
AVA
Account #
20200917
FOB
Signature
E-mail
contact@eidim.com
Web Site
www.eidim.com
Total
Subtotal
Sales Tax (8.25%)
Tel. (877) 773-4346
Fax. (562) 777-9120
6905 Oslo Circle Ste J
Buena Park, CA 90621
Item DescriptionQty TotalCost
** Change Order Request: PTZ Camera Auto tracking Programming **
Programming Crestron & DSP Control programming1 2,724.002,724.00
_____________________________________
*Customer must pre-pay full cost of the equipments in advance. Price valid for 30 days.
1. No patching, conduit, or painting and etc. will be included unless indicated in writing.
2. Depends on availability of the parts, it may take up to 3 weeks for the parts to arrive at the job site.
3. Customer must pay for all additional equipments: parts & accessories that are not in the invoice,
result from change of order, typing error and accidental omission.
4. Customer must pay 35% restocking charge in case of exchage & return of item.
5. 4% Transaction Fee will be charged for Credit Card Transaction
$2,724.00
$2,724.00
$0.00
Page 296 of 390
CONSTRUCTION CONTRACTORS ESTIMATE OF COST (FOR CHANGE ORDER)Ref.:
RFP --EST #5060 r.2
City of Ukiah - Council Chambers /PTZ Camera tracking programming
CONTRACT NO.:
Prime Contractor:EIDIM AV Technology * th = Technician Hour
* ah = Administrator Hours
LABOR MATERIAL EQUIPMENT
NO.ITEM DESCRIPTION QTY UNIT Un. Cost Ttl Cost Un. Cost Ttl Cost Un. Cost Ttl Cost
Administrative Work
1 Processing of Submittals 0 mh 47.00 0.00 0.00 0.00
2 Catalog Change 0 mh 0.00 0.00 0.00 0.00
3 Scheduling 2 mh 47.00 94.00 0.00
4 As-built 0 mh 47.00 0.00 0.00 0.00
5 Reprographics 0 sf 0.00 0.00 0.15 0.00 0.00
6 0.00 0.00 0.00
Prime Contractor's Work Totals 94.00 0.00 0.00
Technical Work QTY UNIT Un. Cost Ttl Cost Un. Cost Ttl Cost Un. Cost Ttl Cost
7 0 ls 0.00 0.00 0.00 0.00
8 0 th 0.00 0.00 0.00 0.00
9 0 th 0.00 0.00 0.00 0.00
10 0 ah 0.00 0.00 0.00 0.00
11 Submittal preparation, new equipment 0 th 0.00 0.00 0.00 0.00
12 N/A 0 ah 0.00 0.00 0.00 0.00
13 Engineering, new equipment 0 th 0.00 0.00 0.00 0.00
14 0 ea 0.00 0.00 0.00 0.00
14 0 mh 0.00 0.00 0.00 0.00
15 0 ea 0.00 0.00 0.00 0.00 0.00
0.00 0.00 0.00
0.00 0.00 0.00
16 0 mh 0.00 0.00 0.00 0.00
17 20 mh 95.00 1,900.00 0.00 0.00
18 0 ea 0.00 0.00 0.00 0.00
19 0 0.00 0.00 0.00 0.00
20 2 mh 65.00 130.00 0.00 0.00
21 0 lot 0.00 0.00 0.00 0.00
22 0 th 47.00 0.00 0.00 0.00
23 2 Lot 300.00 600.00 0.00 0.00
24 0 mile 0.60 0.00 0.00 0.00
Technical Work Totals 2,724.00 0.00 0.00
Traveling (includes lodging and food)
Traveling (Miles) - Round Trip
Shipping
Field install of added components not part
of original equipment list
Field R&R Existing Infrastructure
Onsite Training
Warranty (Equipment) -
Shop Install, Added Equipment
Cables, parts, accessories
Shop Labor
Field Install, Added Equipment
Programming
Equipment Rental - Lift, Scaffold, Ladder
or others
Prepare new equipment quote sheets
Buyout for new equipment
Purchase orders and admin for new
equipment
Warranty (Tech support - email, call, onsite
Support)
Page 2 of 2
Page 297 of 390
Please return to:
CITY OF UKIAH
300 Seminary Avenue
Ukiah, California 95482-5400
(707) 463-6200
NOTICE OF COMPLETION
NOTICE IS HEREBY GIVEN:
1.That the project described as: Council Chambers AV Replacement Project, Specification No. 20-09.
2. That the nature of the title to the Upgrade of technology in the City of Ukiah’s Council Chamber and
establish audio/visual capability in the City of Ukiah’s conference rooms Nos. 3 and 5.
3. That on the October 10, 2022, the Contract work for this project was actually completed.
4. That the name and address of the Contractor is EIDIM Group, Inc., 1015 S Placentia Ave. Fullerton, CA
92831
5. That the property location of work performed herein referred to is situation in the County of Mendocino,
State of California, and is described as follows: City Hall - 300 Seminary Ave, Ukiah, California; and
City Hall Annex - 411 West Clay Street, Ukiah California.
I hereby certify under penalty of perjury that the forgoing is true and correct:
City Council Approval CITY OF UKIAH, a Municipal Corporation
_________________ By:__________
Date Kristine Lawler, City Clerk Date
State of California
County of Mendocino
Exempt from recording fees pursuant to Government Code Section 27383
ATTACHMENT 5
Page 298 of 390
Page 1 of 2
Agenda Item No: 12.a.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2154
AGENDA SUMMARY REPORT
SUBJECT: Consideration of Approval of Scope of Work for General Plan Mobility Subconsultant GHD to
Expand the City's SB 743 Methodology to Include Multimodal Networks; Approval of Contract Amendment with
Mintier Harnish, General Plan Consultants; and Approval of Corresponding Budget Amendment.
DEPARTMENT: Community
Development PREPARED BY: Craig Schlatter, Community Development Director
PRESENTER: Craig Schlatter, Community Development
Director
ATTACHMENTS:
1. 9-21-22 13a Presentation Given at Meeting
2. Ukiah SB-743 Methodology-10.3.22 GHD memo
3. Ukiah SB-743 Mitigation Proposal_10.21.22
4. Amendment 3- C#1819190 (GHD SB 743)
Summary: Council will consider approving a scope of work for General Plan Mobility Subconsultant GHD to
expand the City's SB 743 methodology to include multimodal networks. Council will also consider approving
the corresponding amendment to the contract with Mintier Harnish, General Plan consultants, as well as a
corresponding budget amendment.
Background: As a part of the City's update to its General Plan and associated Draft Environmental Impact
Report (DEIR), Council has discussed with Staff and approved methods of evaluation of transportation-related
Green House Gas (GHG ) emissions as required under SB 743. This effort has involved analysis and
development of a methodology and thresholds by the City's General Plan mobility subconsultant, GHD.
On September 15, 2022, GHD completed a Technical Memorandum describing a proposed methodology for
assessing transportation impacts in Ukiah consistent with SB 743 and current California Environmental Quality
Act (CEQA) Guidelines. At its September 21, 2022 meeting (see Attachment 1 for a copy of the presentation
slides for the September 21 meeting), Council discussed the proposals and voted to continue the item to the
October 5, 2022, meeting so that further analysis could be undertaken and key questions by Council
answered.
At the October 5, 2022 meeting, Council discussed the updated Technical Memo prepared by GHD on
October 3, 2022 (Attachment 2). As noted by Staff and GHD in the presentation of the updated thresholds, the
recommendations provided a "99% solution," meaning that the methodology and thresholds proposed were
expected to be appropriate for 99% of future projects in Ukiah. Staff also noted that a "100% solution," which
would require expansion of the SB 743 methodology to include multimodal networks and acceptable mitigation
options, was possible but would need additional research and analysis. Council approved the baseline
methodology and thresholds proposed in the October 3, 2022 Technical Memo and directed Staff to return
with a scope of work and possible contract amendment to pursue the 100% solution.
Discussion: GHD has prepared a scope of work and cost proposal (Attachment 3) to expand the City's SB
743 approach to include multimodal networks. As noted within the proposal, this work would result in the
preparation of a technical memorandum outlining impact reduction and mitigation options. Combined with the
Council-approved methodology and thresholds contained within the October 3, 2022 technical memo
Page 299 of 390
Page 2 of 2
(Attachment 2), the new memo is expected to provide a comprehensive SB 743 methodology for 100% of
future projects in Ukiah.
Per email correspondence with GHD staff on October 26, 2022, GHD noted the methodology was expected to
be quite a bit of additional work but they had "found an internal funding program to help develop a significant
portion of it, and their fee to the City essentially represents the effort necessary to build in the Ukiah-specific
elements (a bikeway network, bikeway improvements, etc)." Consequently, of the $34,290 total project cost,
GHD would fund $12,765, leaving a City contract amendment (Attachment 4) for the additional work at a not to
exceed cost of $21,525.
Staff recommends Council approve the scope of work in Attachment 3 and contract amendment within
Attachment 4. If approved, the scope of work would become "Exhibit 1" of the contract amendment within
Attachment 4.
Recommended Action: Approve scope of work for General Plan mobility subconsultant GHD to expand the
City's SB 743 methodology to include multimodal networks; contract amendment with Mintier Harnish, General
Plan consultants; and a corresponding budget amendment.
BUDGET AMENDMENT REQUIRED: Yes
CURRENT BUDGET AMOUNT: 31523100.52100.18146: $0
PROPOSED BUDGET AMOUNT: 31523100.52100.18146: $21,525
FINANCING SOURCE: Advanced Planning Fund (2040 General Plan)
PREVIOUS CONTRACT/PURCHASE ORDER NO.: C#1819190
COORDINATED WITH: Todd Tregenza, Colin Burgett, and Donald Hubbard, GHD
Page 300 of 390
Ukiah SB-743 Approach
l GHD[Footer text]1
September 2022
Attachment 1
Page 301 of 390
– Background on SB-743
– Proposed Approach
– Thresholds and Screening
– Questions & Answers
Topics Covered
l GHD2
Page 302 of 390
Background
on SB-743
Page 303 of 390
Why Was SB-743 Passed?
l GHD4
– California faces related, simultaneous crises in
housing and climate change.
– Transportation accounts for about half of
California’s carbon footprint. We can’t meet our
GHG reduction goals unless something is done
about
– Incremental measures to reduce GHG are not
working. Legislators felt that something more
drastic is needed
Page 304 of 390
– Correct an unintended consequence of CEQA,
which was to make infill development difficult
relative to greenfield development*
– Align CEQA traffic analysis with greenhouse gas
reduction goals
– Simplify approval of bicycle, pedestrian, transit,
and transit-supportive projects
– Eliminate the need for lengthy, expensive traffic
studies
The Goals of SB-743
l GHD5
* A recent study found that environmentally-friendly projects are the most common targets for
CEQA lawsuits. 98%of the proposed homes targeted by CEQA lawsuits were infill housing,
mostly multi-family
Page 305 of 390
– SB-743 overturned decades of practice regarding how traffic impacts are analyzed. It
specifically prohibits the use of level-of-service to determine traffic impacts under CEQA
The Challenges of SB-743
l GHD6
– Although the law went into effect state-wide in July 2020,
the replacement methodologies are only partly fleshed out
and many uncertainties remain.
– The guidelines are confusing and certain to be interpreted
differently by different people. This is a ripe environment for
lawsuits
– There is not yet any established body of case law to show
what analytical approaches courts will accept, or what
mitigations will suffice. Just because an agency thinks that
an approach is acceptable does not mean that courts will
agree, and it is the courts’ opinions that count
Page 306 of 390
– The authority to set local infrastructure standards, including
roadway LOS, are based on local jurisdictions’ police powers.
This authority is independent of CEQA; CEQA could be revised
or even repealed in its entirety and a jurisdiction’s authority to
maintain LOS standards would be unimpaired
– Moreover, use of LOS is still legally required by other California
laws, and is commonly used in Federal programs
– Besides, it is needed as an input for design work, air quality
analysis, etc.
So what Happens to LOS?
l GHD7
It’s not going away:
– So few, if any, jurisdictions have stopped using LOS. They simply shifted it from a CEQA
requirement to a General Plan requirement. This is what happened previously when
parking impacts were removed from CEQA
Page 307 of 390
Proposed
Approach
Page 308 of 390
SB-743 Requirements
l GHD9
• SB-743 leaves the choice of metrics and methodologies up to the lead agency
• The intent for SB-743 is that, “Those criteria shall promote the reduction of
greenhouse gas emissions, the development of multimodal transportation
networks, and a diversity of land uses.” (§ 21099(b)(1))
• The “and” means that all 3 goals must be addressed. Our proposed approach
does just that:
o Reduces GHG emissions by substituting short commutes for long ones
o Promotes multimodal transportation networks by putting jobs within biking and
walking range of residential neighborhoods, and by prioritizing development of
non-auto paths
o It promotes a diversity of land uses by reducing jobs/housing imbalances
Although this legislation is directed towards climate change and affordability concerns,
it could just as easily have been pursued for quality-of-life reasons. People like living
walkable communities with shops and services conveniently nearby
Page 309 of 390
Overview of Approach
l GHD10
– Make the argument that Ukiah is the smart growthiest place in Mendocino. The larger the
share of the county’s growth that is channeled to Ukiah the better, for a host of reasons
mentioned in CARB’s Climate Change Scoping Plan (farm and forest preservation, use of
non-auto modes, etc.)
– Create a scoring system that would allow GP alternatives to be evaluated based on how
well they achieve the three goals set forth in §21099(b)(1):
• Reducing GHG emissions
• Promoting multi-modal transportation networks
• Promoting a diversity of land uses
Page 310 of 390
– Ukiah’s current job/housing balance is skewed
towards jobs, yet only about 1/4th of the jobs are
held by local residents. There are large volumes
of both imported and exported workers
– A possible criteria would be to classify land uses
into residential, retail, and other non-residential.
The goal would be to bring these 3 classes into
local balance, with the region-wide average ratio
being taken as the ideal mix
– This could be done as a GIS buffering exercise.
The idea is that a local balance is needed to
make walking and biking viable options
Diversity of Land Uses
l GHD11
73% of Ukiah
employees live
outside the City
61% of Ukiah’s
working residents
work outside the City
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
Jobs per Resident
County Average
State Average
Page 311 of 390
Diversity of Land Uses - Methodology
l GHD12
– Divide the study area into hexagons
– Find the number of households, retail jobs, and
non-retail jobs for each hexagon using parcel
data
– Compute the jobs/housing, jobmix, and
retail/housing diversity scores for each hex,
including its immediate neighbors
– Weight the 3 diversity scores by the % of trips
they represent, then combine into a single score
for each hexagon
– Compare the aggregate scores for different
alternatives
Page 312 of 390
Split the Study Area into Hexagons
l GHD13
Households Non-Retail JobsRetail Jobs
Page 313 of 390
Interactions between Land Uses
l GHD14
Non-Home-Based
Residential
Retail JobsNon-Retail Jobs
Home-Based Work: 20%
Home-Based Other: 48%
Non-Home-Based: 32%
Page 314 of 390
Diversity of Land Uses - Equations
l GHD15
Jobs/Housing Diversity =1-[ABS(b*HHs-EMP)/(b*HHs + EMP)]
Jobmix Diversity = 1-[ABS(c*REMP-NEMP)/(c*REMP + NEMP)]
Retail/Housing Diversity = 1-[ABS(b*HHs-REMP)/(b*HHs + REMP)]
Where:
HH = Number of households
REMP = Number of Retail and Service Jobs
NEMP = Number of Non-Retail Jobs
EMP = Total number of jobs (i.e. REMP + NEMP)
b = total regional employment / total regional households
c = total regional non-retail jobs / total regional retail jobs
d = total regional retail/service employment / total regional households
Interactions between housing and jobs
Interactions between retail and non-retail jobs
Interactions
between housing
and retail/services
Scores range from -1 to 1.
The lower the score, the
better (the less deviation
from the ideal mix). Ideal
score is zero.
Page 315 of 390
Combined Diversity Score – Existing Conditions
l GHD16
Area with existing
land use
imbalances
Page 316 of 390
Hypothetical Proposed Project
l GHD17
Developer proposes to build a residential project in a hexagon that, with its neighboring six
hexagons, currently has 500 dwelling units, 500 retail jobs, and 500 non-retail jobs. The
developer would like to build 2,000 additional dwelling units, but their EIR will include a
reduced-impact alternative with only 500 additional dwelling units.
City staff would note the diversity indices for existing conditions, then add 2,000
households and note the results. They would repeat the procedure for 500 households.
When they tabulate the results, they would get a table like this:
Page 317 of 390
Identifying the Sweet Spot
l GHD18
Jobs/Housing Diversity Retail/Housing Diversity
Page 318 of 390
Identifying the Sweet Spot
l GHD19
Combined Diversity Score
“Goldilocks”
combination;
900 new DUs
Page 319 of 390
Advantages:
– Focuses on the root cause of VMT; land use imbalances
– Plays to Ukiah’s relative strengths (compact, walkable, etc.)
– Provides nuanced, informative results
– Open architecture. Easy to modify if desired (more land use types, for example)
– Very user-friendly. No need to for expensive modeling software or training. Can be done
by staff using spreadsheet software they already have
Advantages of this Methodology
l GHD20
Disadvantages:
– Uses a legally untested approach (though VMT has not been tested, either)
– Not suitable for large study areas with major transit infrastructure
Page 320 of 390
Thresholds &
Screening
Page 321 of 390
– Lead agencies are not required to adopt thresholds, but they must base their conclusions on
something supported by substantial evidence; failure to do so leaves an EIR vulnerable to
challenge
– It is best practice to adopt general thresholds through an ordinance because:
• It provides clear guidance to staff, developers, and the public
• It provides a level playing field; all projects are treated equally
• The analysis of substantial evidence need only be done once
• The process is open, transparent, and takes place at the City Council level
– Using ad hoc thresholds leaves EIRs open to manipulation and pressure, and adds to the
cost and uncertainty of EIRs
Discussion of Thresholds
l GHD22
Page 322 of 390
Thresholds have 3 components, namely:
1) A unit of measurement
2) A target amount of reduction
3) A baseline that the reduction is measured from
Discussion of Thresholds
l GHD23
Page 323 of 390
• Mendocino COG commissioned a study of SB-743 issues in 2020
• The study did not appear to reach a specific conclusion regarding
numerical thresholds
• It suggested using VMT per service population (combined housing and
employment) as a metric. That would be problematic for Ukiah.
MCOG Study
l GHD24
• Because work trips tend to be longer than other trip types, using "service
population" may produce a nonsensical result for employment centers.
Their VMT/service population may be above average even if each
individual component (VMT/job and VMT/resident) is below the regional
average
11% below average
5% above average
20% below average
Number VMT/Unit Number VMT/Unit
Employees 10,000 18.0 20,000 16.0
Residents 20,000 10.0 10,000 8.0
Service Population 30,000 12.7 30,000 13.3
City 1
Bedroom Community
City 2
Employment CenterPopulation
Measured
Page 324 of 390
How Much of a Reduction is Enough?
l GHD25
• CARB concluded that an average 15% reduction is needed to achieve the State’s GHG
reduction goals (see California’s 2017 Climate Change Scoping Plan)
• However, this state-wide average may not be appropriate for all jurisdictions, and CARB has
set higher targets in some MPO areas and lower targets in others
• Ukiah is not in a MPO area and is not bound by any of these targets. It is most similar to
Shasta RTA, which has a 4% target reduction
0%
2%
4%
6%
8%
10%
12%
14%
16%
18%
20%
Pe
r
c
e
n
t
R
e
d
u
c
t
i
o
n
i
n
V
M
T
CARB 2035 Reduction Goals
Page 325 of 390
– SB-743 is somewhat unusual in that a City has some flexibility to select thresholds that suit
its policy goals:
• If located in a large metropolitan area, it can choose to use a threshold based on averages
for the MPO region as a whole. This will likely result that residential development in outer
suburban cities will have significant VMT impacts because it is compared to the urban core
• It can use a threshold based on county averages, which will result in developments in
existing towns having less-than-significant impacts compared to developments in rural
areas
• It can use the city average VMT, meaning that developments in the center will be less-
than-significant and the developments on the periphery will likely have significant impacts
– Threshold(s) should be done by ordinance separate from the General Plan, otherwise you
would need a General Plan amendment each time you want to change it
SB-743 Thresholds
l GHD26
Page 326 of 390
A land development project would be deemed to have a significant impact if:
The Plus Project condition results in a combined diversity score greater than 0.20, and the
combined diversity score improves less than 4%.
What it means:
–This allows for some densification of balanced areas, If you have areas that are already
pretty well balanced then you can add more to them, so long as you don’t tip them out of
balance
–If you are building in an area that is currently unbalanced, then you are required to push it (at
least a little) in the direction of being more balanced.
Proposed Framework for SB-743 Thresholds
l GHD27
Page 327 of 390
Effect of the SB-743 Threshold
l GHD
28
Households Retail Jobs
Fringe Infill
Development Development
Old System Easy Hard
New System Hard Easy
SB-743 flips the script. It used to be
easy to build on the urban fringe but
hard to build infill. The new system
makes it easier to build infill and
harder to build on the fringe.
Page 328 of 390
The intent is to not over-burden small projects with negligible impacts with a need for
costly analysis
CEQA Guidelines provide for a Class 1 categorical exemption for an expansion of an
existing use of up to 10,000 sq.ft. based (§15301(e)(2)). The 10,000 sq.ft. figure also
applies for new non-residential projects in urban areas (Class 3 exemption, §15303(c)).
The figure is 2,500 sq.ft. in rural areas.
OPR interpreted this to be 110 trips/day, based on Single Tenant Office Building (ITE Code
715) as a “typical” use. It is unclear what the legal basis would be for departing from direct
use of the 10,000 sq.ft.
Other agencies extended this logic of analogies to previously-exempt projects. LADOT
uses 250 trips and San Diego 300 trips. These are not yet tested in court
The most defensible approach would be to use the thresholds exactly as they are written
in the CEQA Guidelines
Screening out for Small Project Size
l GHD29
Page 329 of 390
Thresholds for Transportation Projects
l GHD30
•“Those criteria shall promote the reduction of greenhouse gas emissions, the
development of multimodal transportation networks, and a diversity of land uses.”
• We recommend setting a threshold that explicitly focuses on balancing transportation
modes within the city. An example would be:
“A project’s impacts shall be deemed significant if it results in a percentage increase
in road capacity higher than the percentage increase in bicycle or multi-use capacity.”
• Note that this threshold would make all active transportation projects presumptively
less-than-significant.
• It would not preclude the City from undertaking road expansion projects, but it would
mean that such projects would need to include expansion of the bicycle facility system
as well.
• As written, it would require a 1:1 expansion of the two systems, but it could easily be
tweaked to require a 2:1 or 3:1 expansion of bike facilities to help that system catch up
with the facilities offered to cars.
Page 330 of 390
Questions &
Answers
Page 331 of 390
Technical Memorandum
The Power of Commitment
11196303 1
October 3, 2022
To Craig Schlatter, City of Ukiah Contact
No.
(707) 463-6219
Copy to Jim Harnish, Mintier Harnish Email cschlatter@cityofukiah.com
From Colin Burgett Project No. 11196303
Project
Name
City of Ukiah General Plan Update
Subject SB-743 Methodology
This memorandum augments the prior memorandum provided by GHD (dated September 15, 2022)
concerning the proposed SB-743 methodology with the following additional information relevant to
upcoming discussions concerning the proposed SB-743 methodology:
Comparison of the citywide land use diversity score with the regional rate for Mendocino County;
Screening threshold recommendations by type of project; and
Example application of the proposed diversity index methodology to hypothetical projects on the
edges of Ukiah.
1. Comparison with Countywide Land Use Diversity
Table 1 provides a comparison of the existing citywide and countywide land use diversity scores, based on
the distribution and proximity of households, retail and non-retails. The diversity score ranges from 0.00 to
1.00, with lower scores (close to 0.00) representing diverse conditions, and higher scores (closer to 1.00)
representing less diverse conditions.
As shown, under existing conditions, the Countywide diversity index is 0.50, while the City of Ukiah score is
0.30, indicating that the diversity of land uses in Ukiah that is superior to the Countywide average. This
reflects the fact that a large portion of Ukiah residents live relatively close to work and/or local services,
generating lower rates of vehicle miles traveled (VMT).
Table 1: Land Use Diversity Score (City & County)
Note: The diversity score ranges from 0.00 to 1.00, with lower scores (close to 0.00) representing diverse conditions,
and higher scores (closer to 1.00) representing less diverse conditions.
Area Existing Total Land Use
Diversity Score
City of Ukiah 0.30
Mendocino County 0.50
Attachment 2
Page 332 of 390
11196303 2
2. Screening Recommendations
Local agencies may identify screening thresholds to quickly identify when a project should be expected to
cause a less-than-significant impact without conducting a detailed study. The screening thresholds may be
based on characteristics including project size, location, transit availability or provision of affordable
housing, consistent with guidance provided by the Governor’s Office of Planning and Research (OPR).
Table 2 summarizes recommended screening thresholds by project type. Taking into account the unique
travel characteristics of Ukiah, all residential projects in Ukiah could be screened from further analysis as
recommended below, because (1) residences located in Ukiah generate low rates of home-based VMT per
Capita compared to the rest of Mendocino County (roughly half the Countywide average based on the
Mendocino COG travel demand model) given greater proximity to jobs and services; and (2) Ukiah has a
jobs/housing imbalance, with an excess of jobs relative to the number of households, that results in most
Ukiah jobs being filled by non-resident commuters; therefore the provision of housing projects in Ukiah
would increase the likelihood that that a larger portion of workers employed in Ukiah may also reside in
Ukiah, thus reducing VMT given shorter commute lengths.
Table 2: Screening Recommendations
Type of Project Recommended Screening Thresholds for City of Ukiah
Small Projects Projects that meet the existing CEQA categorical exemptions: Class
1 exemption, for small expansions of existing uses, and Class 3, for
new small projects, as specified in CEQA Guidelines §15301 and
§15303
Residential Uses Residential1 projects.
Employment Uses2 in Areas with
a Diverse Mix of Land Uses
Proposed employment uses in zones with a total diversity score at
least 4% better than the Countywide average.
Local-serving Retail Neighborhood shopping centers3 with a total gross leasable area of
up to 125,000 square feet, with multiple tenants typically anchored by
a supermarket or drugstore; and single tenant local-serving retail
projects of 50,000 sq. ft. or less.
Projects in Proximity to Major
Transit Stops
Projects within one-half (0.5) mile of a transit stop with 15 minute or
less headways, unless the project has a Floor Area Ratio (FAR) of
less than 0.75, reduces the supply of affordable housing, or includes
more parking than required under the zoning code.
Transportation Projects Roadway, transit, bicycle, and pedestrian projects that do not lead to
a measurable increase in vehicle travel.
1 All residential projects in Ukiah may be expected to result in less than significant transportation impacts relevant to VMT and SB-743,
because ( (1) residences located in Ukiah generate low rates of home-based VMT per Capita compared to the rest of Mendocino
County (roughly half the Countywide average based on the Mendocino COG travel demand model) given greater proximity to jobs and
services; and (2) Ukiah has a jobs/housing imbalance, with an excess of jobs relative to the number of households that results in most
Ukiah jobs being filled by non-resident commuters; therefore the provision of housing in Ukiah would increase the likelihood that that a
larger portion of workers employed in Ukiah may also reside in Ukiah, thus reducing VMT given shorter commute lengths.
2 The screening threshold for employment uses would be applicable to proposed commercial land uses in which most daily trips would
be generated by employees (not customers), such as proposed office projects.
3 Neighborhood shopping centers of up to 125,000 square feet as defined by the International Council of Shopping Centers (ICSC)
U.S. Shopping Center Classification and Characteristics, provide 30,000 to 125,000 square feet of gross leasable area, typically
anchored by a supermarket and/or large drugstore with a trade area of 3 miles or less.
Page 333 of 390
11196303 3
3. Hypothetical Projects at Edge Locations
In response to questions about the likely impacts for potential projects at “edge locations” near the City
limits, in areas that are currently undeveloped, several hypothetical projects were considered as examples
for upcoming discussion. Table 3 summarizes the potential impact findings, based on the comparing the
diversity score for the Project area (Hex Zone) with the Countywide average. The diversity score for
individual Hex zones takes into account the land use diversity of adjacent Hex zones. The methodology for
assessing interconnectivity between adjacent Hex zones may also be refined for Ukiah to further
incorporate multi-modal characteristics and travel amenities. Figure 1 shows the Hex Zone locations.
Table 3: Hypothetical Projects at Edge Locations
Hypothetical
Project
Location
(Hex Zone)
Total Diversity Score for
Project Zone Potential Impact Finding based
on Comparison with Countywide
average4 No Existing
Existing
plus
Project
1
Industrial near
North edge of
Ukiah
492 N/A
(undeveloped) 0.23 Less than significant
2
Retail
>150,000 sq ft
near South
edge of Ukiah
181 0.87 0.93
Significant requiring mitigation(s).
For projects requiring mitigations:
mitigation options specific to the
City of Ukiah could be identified as
this analysis methodology is
refined further. Potential
mitigations could include provision
of multi-modal improvements (such
as potential connections to a
planned bicycle/pedestrian path
along Airport Road that will
connect the South edge of Ukiah
with downtown).
4 Project impacts would be considered less than significant if the total diversity score for the project zone under Existing plus Project
conditions would be at least 4% lower than the Countywide average of 0.50
Page 334 of 390
86 87
110
111
112
133 134 135
136
157
158
159
174 175 176 180 181 182
198 199 200 203 204 205
206
220 221 222
223
224 225 226
227
228
229
230
245 246 247 248 249 250
251
252
253
254 255
268 269 270 271 272 273
274 275
276
277 278
280
296 297 298
299
300 301
302 303
304 305
319 320
321 322 323
324
325
326
327 328
344 345
346 347 348
349
350
351
368
369 370 371
372
373 374
392
393 394
395
396
397 398 399 400
416
417 418
419
420 421 422
441 442 443 444 445
446
447
450
467
468
469 470
473
492
493
494
Legend
Total Diversity
0 - .1
.11 - .2
.21 - 30
.31 - .4
0.41 - 0.5
0.51 - 0.6
0.61 - 0.7
0.71 - 0.8
0.81 - 0.9
0.91 - 1
Total Trips
Trips
0
3,245
6,490
9,735
Annexation Areas
City Limits
Highway
Roads
FIGURE 1
09/19/2022Date
-Revision No.
11196303Project No.CITY OF UKIAH
GENERAL PLAN UPDATE 2040
HEX ZONE LOCATIONSMap Projection: Lambert Conformal Conic
Horizontal Datum: North American 1983
Grid: NAD 1983 StatePlane California II FIPS 0402 Feet
0 500 1,000 1,500 2,000
US Feet
Paper Size ANSI B
Data source: City Boundary, Annexation Area: Mintier Harnish, 2022. World Imagery: Earthstar GeographicsCreated by: pthornton\\ghdnet\ghd\US\Roseville\Projects\561\11196303\GIS\Maps\Working\11196303_VMT Option 2 Analysis_20220901\11196303_VMT Option 2 Analysis.aprx
Print date: 19 Sep 2022 - 11:49
427
428
450 451 452 453
473 474 475
476
477
501
Annexation Area to the Northeast
Page 335 of 390
The Power of Commitment
GHD
PO Box 7967
Santa Rosa, California 95407
United States
www.ghd.com
Scope of Work (October 21, 2022)
Assistance to Expand the City of Ukiah’s SB 743 Approach to Include Multimodal Networks
A. Additional Services to be Performed:
Task A.1: SB 743 Mitigation Options
Building off of the methodology recently approved by City Council to establish a transportation impact
framework that is consistent with SB 743, including performance standards and thresholds of significance,
GHD will prepare a technical memorandum outlining impact reduction and mitigation options. These may
include changes to project land uses, density, and design. These may also include consideration of GHG
reducing strategies from the updated California Air Pollution Control Officers Association (CAPCOA)
Handbook for Analyzing Greenhouse Gas Emission Reductions, Assessing Climate Vulnerabilities, and
Advancing Health and Equity (CAPCOA Handbook).
GHD also proposes to establish a quantifiable mechanism to reduce transportation impacts through the
construction of high-quality bikeways that can extend the safe non-motorized travel range of workers and
residents. This mechanism will build off of the GIS platform developed and approved by City council to
calculate SB 743 transportation impacts for land development projects. This mechanism would allow for an
offsite improvement to reduce project specific SB 743 impacts through bikeway network gap closures, and
through the improvement in the quality of the bikeway network, as measured in improved bikeway service.
This task includes a kick-off meeting (as an internal workshop) with City Staff to establish a preliminary
framework (facility type, facility score, analysis scope) to guide the subsequent analyses and development
of the hex based tool to include multimodal networks. This task also includes consideration of other viable
score improvement (VMT reduction) strategies outside of the hex-based GIS tool.
Task A.2: Citywide Level of Traffic Stress Analysis
GHD will complete a Bicycle Level of Traffic Stress (BLTS) analysis and network connectivity assessment
that will measure the quality of multimodal connectivity between hex grid destinations using the existing
and planned bike network to compare between existing conditions and the General Plan 2040 Buildout
scenario.
Level of traffic stress (LTS) is a suitability rating system from the perspective of different subsets of the
population, which measures the perceived comfort, safety and convenience associated with bicycling or
walking in or adjacent to vehicle traffic. Studies have shown that 60 percent of the population will be
deterred from bicycling or walking if an active transportation facility features high levels of traffic stress,
and they will only choose the routes with the highest levels of perceived comfort and safety.1 Using the
BLTS methodology, facilities are scored on a one to four scale in which facilities that receive LTS scores of
1 are considered the lowest stress and highest quality, and those that receive LTS scores of four are the
highest stress and lowest quality.
The BLTS analysis employs the level of traffic stress methodology described in the Oregon Department of
Transportation (ODOT) “Analysis Procedures Manual Version 2, Chapter 14, Multimodal Analysis,”
(October 2020), which is based on based on the paper, Low Stress Bicycling and Network Connectivity,
Report 11-19, published by the Mineta Transportation Institute (MTI) (May 2012). The LTS methodology
as reported by ODOT’s latest Multimodal Analysis Procedure Manual includes updates to the methodology
that was originally published by MTI. The updated methodology includes analysis criteria for new bicycle
facility types that have become more popularly used since the original report was published and considers
1 “Four Types of Transportation Cyclists in Portland,” Geller, 2006
Attachment 3
Page 336 of 390
The Power of Commitment
Task Order | VMT for SB 743 2
additional infrastructure types not analyzed under the original MTI methodological approach. The
methodology considers a variety of roadway infrastructure characteristics including but not limited to the
following: number of travel lanes (i.e., road width), posted/prevailing speed, roadway functional
classification or Average Daily Traffic (ADT), and degree of separation from the roadway.
The level of traffic stress assessment will determine the quality of the existing and planned bicycle network
and allow gaps in high quality network connectivity to be identified. GHD will then create a series of origin-
destination matrices between hex locations, which will measure the percent of connectivity between hex
destinations using the high quality/low stress identified by the BLTS analysis.
The results of this analysis will be incorporated with the SB 743 methodology, prepared by GHD and
recently adopted by Ukiah City Council.
Task A.3: Calculate Impact Reductions for Multimodal Network Improvements
GHD will develop a process to modify hex scores to account for existing connectivity via multimodal
networks. From this baseline modified hex score, a score modification process to account for investments
in active transportation infrastructure will be developed based on anticipated increases in opportunities for
low-stress bicycle connectivity, and a commensurate decrease in VMT through an increase in bicycle use.
The intent of this analysis will be to provide a mitigation quantification mechanism for development projects
that could otherwise cause a potentially significant CEQA transportation impact, even if the proposed new
or improved bikeway investment is not immediately adjacent to the proposed project.
Task A.4: Council Presentation
GHD shall prepare a presentation and present the recommendations of Tasks A.1 and A.3 at up to two (2)
City Council meetings via video call.
B. Compensation:
GHD estimates completion of draft tech memos 4 weeks after Notice to Proceed. Work will be performed
on a not-to-exceed time and materials basis, broken down by staff in estimated hourly increments as
summarized on Table 1. GHD will internally fund a portion of this work under our Delivery Transformation
budget (described as “GHD Portion” below). Therefore, after subtracting the GHD Portion: the total
compensation for these additional services (“City Portion”) will be for an amount not to exceed $21,525.
Table 1 Cost Estimate
Task #Task Don
Hubbard
Colin
Burgett
Todd
Tregenza
Paige
Thornton
GIS
Specialist
Total
Hours
Total
Cost
Rate & Hours $ 245 $ 200 $ 200 $ 140 $ 220 -
A.1 SB-743 Mitigation Options 8 4 2 16 2 32 $5,840 $0 $5,840
A.2 Citywide LTS Analysis 2 4 4 24 40 74 $14,250 $7,125 $7,125
A.3 Calculate Impact Reduction Rate 16 4 4 16 16 56 $11,280 $5,640 $5,640
A.4 Council Presentation 8 2 4 14 $2,920 $0 $2,920
34 12 12 60 58 176 $34,290 $12,765 $21,525 Total
GHD
Portion
City
Portion
Page 337 of 390
Attachment 4
CITY OF UKIAH
AMENDMENT 3
TO
CONTRACT #1819190 – PROFESSIONAL PLANNING SERVICES FOR A GENERAL PLAN
UPDATE, ENVIRONMENTAL IMPACT REPORT,
AND OTHER RELATED ADVANCED PLANNING SERVICES
This Amendment No. 3, entered on July 5, 2022, revises the Agreement for Professional services dated
March 21, 2019 between the City of Ukiah and Mintier Harnish for consulting services related to
professional planning services for a General Plan Update, Environmental Impact Report, and other
related advanced planning services.
This Amendment No. 3, as per Exhibit 1:
1) Amends the Scope of Services to include a refinement to SB 743 activities as described.
2) Adds an additional dollar amount of $21,525, for a revised total contract amount of $577,835.
Except as expressly amended by this Amendment, all other terms remain unchanged and in full force
and effect.
IN WITNESS WHEREOF, THE PARTIES HAVE EXECUTED THIS AMENDMENT ON
THE EFFECTIVE DATE:
MINTIER HARNISH
BY: DATE:
JIM HARNISH, JD
CITY OF UKIAH
BY: DATE:
SAGE SANGIACOMO, CITY MANAGER
ATTEST
BY: DATE:
KRISTINE LAWLER, CITY CLERK
Page 338 of 390
Page 1 of 1
Agenda Item No: 13.a.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2043
AGENDA SUMMARY REPORT
SUBJECT: Introduction of an Ordinance, by Title Only, to Adopt the 2022 California Fire Code as Amended.
DEPARTMENT: Fire PREPARED BY: Doug Hutchison, Fire Chief
PRESENTER: Doug Hutchison, Fire Chief
ATTACHMENTS:
1. 2022 Fire Code Adoption Ordinance Redline
2. 2022 Fire Code Adoption Ordinance Clean
Summary: Council will consider the adoption by ordinance of the 2022 California Fire Code as amended.
Background: The State of California utilizes the International Fire Code (IFC) as published by the
International Code Council (ICC). The State also amends the code to specifically meet the hazards
encountered in the State and allows local jurisdictions to further amend the coed based upon local conditions
and needs.
Discussion: The IFC and California Fire Code are updated every three (3) years and were last updated and
adopted in 2019. This is a routine update and adoption of the most recent code.
Staff recommends introducing the Ordinance (Attachment 1 in Redline version and Attachment 2 in Clean
version) by title only, amending Division 6, Chapter 3, Articles 1 and 3, of the Ukiah City Code, entitled: Fire
Prevention Code, to adopt the 2022 Edition of the California Fire Code, including additions or amendments, as
well as NFPA 1 Chapter 38 thereto to address local conditions.
Recommended Action: Introduce the Ordinance, by title only, amending Division 6, Chapter 3, Articles 1 and
and 3, of the Ukiah City Code, entitled: Fire Prevention Code, to adopt the 2022 Edition of the California Fire
Code, including additions or amendments, as well as NFPA 1 Chapter 38 thereto to address local conditions.
BUDGET AMENDMENT REQUIRED: N/A
CURRENT BUDGET AMOUNT: N/A
PROPOSED BUDGET AMOUNT: N/A
FINANCING SOURCE: N/A
PREVIOUS CONTRACT/PURCHASE ORDER NO.: N/A
COORDINATED WITH: Community Development-Building Department
Page 339 of 390
Page 1 of 14
ORDINANCE NO.X2022-
ORDINANCE OF THE CITY COUNCIL OF THE CITY OF UKIAH AMENDING DIVISION 6,
CHAPTER 3, ARTICLES 1 AND 3, OF THE UKIAH CITY CODE, ENTITLED: FIRE PREVENTION
CODE.
The City Council of the City of Ukiah hereby ordains as follows:
SECTION ONE.
Article 1 of Chapter 3 in Division 6 of the Ukiah City Code is hereby amended to read
as follows (unchanged text is omitted and is shown by “* * *”):
§5200 ADOPTION OF CALIFORNIA FIRE CODE
A certain document, three (3) copies of which are on file in the office of the City Clerk of the
City of Ukiah, being marked and designated as the California Fire Code, 2019 2022 Edition,
including Appendix Chapter 4 and Appendices B, BB, C, CC, D, E, F, G, H, I, K, N and O as
published by the International Code Council, and National Fire Protection Association
(NPFA) 1 Chapter 38, be and is hereby adopted as the Fire Code of the City of Ukiah, in the
State of California regulating and governing the safeguarding of life and property from fire
and explosion hazards arising from the storage, handling and use of hazardous substances,
materials and devices, and from conditions hazardous to life or property in the occupancy of
buildings and premises as herein provided; providing for the issuance of permits and
collection of fees therefor; and each and all of the regulations, provisions, penalties,
conditions and terms of said Fire Code on file in the office of the City Clerk are hereby referred
to, adopted, and made part hereof, as if fully set out in this section, with the additions,
insertions, deletions, and changes, if any, prescribed in Division 6, Chapter 3, Articles 2 and
3 of this code. Further, the regulations known as the "SRA Fire Safe Regulations" as set forth
within Title 14, Division 1.5, Chapter 7, Subchapter 2 of the California Board of Forestry
applicable to the State Responsibility Area ("SRA") are hereby incorporated, adopted
verbatim and made part hereof, and such SRA Fire Safe Regulations shall be enforced and
implemented within all applicable High Fire Severity Zones within the City of Ukiah.
§5200.5 INSERTIONS INTO CERTAIN SECTIONS OF THE CALIFORNIA FIRE CODE
2019 2022 EDITION
The following sections of the California Fire Code, 2019 2022 Edition, are hereby revised
amended by inserting information specific to the City of Ukiah so that these sections read as
follows:
101.1 Title. These regulations shall be known as the Fire Code of the City of Ukiah,
hereinafter referred to as "this code."
Section 105.1, General, of Chapter 1 is amended to read as follows:
Attachment 1
Page 340 of 390
Page 2 of 14
105.1 General. Permits shall be in accordance with Sections 105.1.1 through 105.76.25 24
or other provisions of this code as required by the City of Ukiah.
Section 111.1, Board of Appeals Established, of Chapter 1 is amended to read as follows:
111.1 Board of Appeals Established. In order to hear and decide appeals of orders,
decisions, or determinations made by the fire code official relative to the application and
interpretation of this code, there shall be and is hereby created a Board of Appeals. The
Board of Appeals shall be the Board of Directors of the Ukiah Valley Fire District or a sub-
committee as appointed by the Board of Directors of the Ukiah Valley Fire District. The fire
code official shall be an ex-officio member of said board but shall have no vote on any
matter before the board. The board shall adopt rules of procedure for conducting its
business and shall render all decisions and findings in writing to the Appellant with a
duplicate copy to the fire code official.
Section 111.3, Qualifications, of Chapter 1 is deleted.
Section 111.5, Appeals Process, of Chapter 1 is added to read as follows:
111.5 Appeals Process. The appeals process for appeals of orders, decisions, or
determinations made by the fire code official relative to the application and interpretation of
this code shall be defined by sections 111.5.1 through 111.5.5.
Section 111.5.1, Initiating Appeal, of Chapter 1 is added to read as follows:
Section 111.5.1 Initiating Appeal. Any beneficially interested party has the right to appeal
the order served by the fire code official by filing a written “NOTICE OF APPEAL” with the
office of the fire code official within ten days after service of such order and upon payment
of the sum of $150. In the event the order of the fire code official is overturned following
the appeal, the fee shall be returned. The notice shall state the order appealed from, the
identity and mailing address of the Appellant, and the specific grounds upon which the
appeal is made.
Section 111.5.2, Stay of Order, of Chapter 1 is added to read as follows:
Section 111.5.2 Stay of Order. The timely filing of a properly completed notice of appeal
shall have the effect of staying the implementation of the order appealed from until the final
decision of the appeal. Failure to file a timely notice of appeal waives any right to further
challenge the order of the fire code official. “File” means delivered to the office of the fire
code official at 300 Seminary Ln, Ukiah, California 95482.
Exception: Orders affecting acts or conditions which in the opinion of the fire code official,
pose an immediate threat to life, property, or the environment as a result of panic, fire,
explosion, or release are enforceable when made and are not stayed by the filing of a
notice of appeal.
Section 111.5.3, Hearing of Appeal, of Chapter 1 is added to read as follows:
Page 341 of 390
Page 3 of 14
Section 111.5.3 Hearing of Appeal. Following is the process for establishing and hearing
appeals:
The Board of Appeals, or the secretary thereof, shall set the matter to be heard at a date
within thirty (30) days of receipt of such notice of appeal. Written notice of the time and
place set for hearing shall be served on the Appellant by first class mail to the mailing
address given in the notice of appeal. A hearing may not be conducted less than 20 days
after notice is given to the applicant. The Board of Appeals may adopt rules governing the
conduct of its hearings. Those rules shall include, at least, the following:
1. The fire code official shall submit evidence at the hearing substantiating his/her
decision. Such evidence may include testimony, fire district, police or other reports of the
incident, witness statements, and other documents. Not less than 10 days prior to the
scheduled hearing, the fire code official must notify the Appellant of the name, address, and
phone number of any witness to the violation and furnish the Appellant with a copy of any
document the fire code official intends to submit at the hearing. Not less than seven (7)
days prior to the hearing, the Appellant may request the fire code official to produce at the
hearing any witness he/she intends to rely upon to substantiate the violation. The written
request must name the witness or witnesses who are requested to attend the hearing. The
fire code official may not rely on the testimony of any witness (including such testimony
contained in reports or written witness statements) whose appearance at the hearing is
required by this subsection if that witness fails to appear.
2. Not less than 10 days prior to the hearing, the Appellant must notify the fire code official
in writing of the name, address, and phone number of any witness the Appellant intends to
call as a witness at the hearing, provide a brief description of the proposed testimony, and
furnish the fire code official with a copy of any document the Appellant intends to offer as
evidence at the hearing. The Appellant may not call any witness to testify at the hearing
who was not identified as required by this subsection or offer any document as evidence at
the hearing that was not provided to the fire code official as required by this subsection.
3. At the hearing, the Appellant may be represented by an attorney, at the Appellant’s
expense. Both the fire code official and the Appellant shall have the right to examine and
cross-examine any witness produced at the hearing. The rules of evidence that normally
apply in court shall not apply in a hearing before the Board of Appeals, but it shall only
consider evidence that would be relied upon by reasonable people making an important
decision, and shall disregard evidence that by its nature is unreliable or not credible.
4. The entire hearing shall be electronically or stenographically recorded. The Board of
Appeals shall base its decision exclusively on the evidence presented at the hearing and
shall issue a written decision, which includes a statement of the relevant facts that it finds to
be true and explains how the facts support its decision. The record of the hearing shall be
preserved for not less than six (6) months after the decision is served on the Appellant.
Section 111.5.4, Hearing Decision, of Chapter 1 is added to read as follows:
Section 111.5.4 Hearing Decision. The chairperson of the Board of Appeals shall issue
the written decision required by subsection 4 of Section 111.4.3 Hearing of appeal. The
Page 342 of 390
Page 4 of 14
Board of Appeals may issue a decision affirming, modifying, or vacating the order of the fire
code official. The decision shall be in writing and shall be served upon the Appellant by
first class mail to the mailing address given in the notice of appeal. The hearing decision
shall include notice of the Appellant’s right to seek review of the decision pursuant to
California Code of Civil Procedure Sections 1094.5 and 1094.6.
Section 111.5.5, Finality of the Decision of the Board of Appeals, of Chapter 1 is added to
read as follows:
Section 111.5.5 Finality of the Decision of the Board of Appeals. The decision of the
Board of Appeals shall be the final decision for the District. The Board of Appeals shall
have the power to continue any hearing and may, at its discretion, take the appeal under
submission. The Board of Appeals shall render a decision not later than the seventh (7th)
day following the date the matter was taken under submission, and forthwith notify the
interested parties as previously set forth.
Section 111.5.6, Appeal to Superior Court, of Chapter 1 is added to read as follows:
Section 111.5.6 Appeal to Superior Court. Judicial review of the decision of the Board of
Appeals shall be governed by the Code of Civil Procedure Sections 1094.5 and 1094.6.
Section 111.5.7, Enforcement of Decision, of Chapter 1 is added to read as follows:
Section 111.5.7 Enforcement of Decision. Unless stayed by a court, any final decision of
the Board of Appeals is effective immediately and may be implemented and enforced by
the District. The remedies provided by this code are cumulative and in addition to any
other remedies available at law or in equity.
1. Causing, permitting, aiding, abetting, or concealing a violation of any provision of this
ordinance shall constitute a violation.
2.Violations of this code are hereby declared to be public nuisances.
3. A violation of this code constitutes a misdemeanor/infraction punishable by a fine of
$1,000 or by imprisonment in the County jail for six months, or both.
4. In addition to other remedies provided by this ordinance or by other law, any violation of
this ordinance may be remedied by a civil action brought by the District, including, for
example, administrative or judicial nuisance abatement proceedings, other legally
authorized enforcement proceedings, and suits for injunctive relief.
Section 1120.4, Violation Penalties, of Chapter 1 is amended to read as follows:
Section 1120.4 Violation Penalties. Persons who shall violate a provision of this code or
shall fail to comply with any of the requirements thereof or who shall erect, install, alter, repair
or do work in violation of the approved construction documents or directive of the fire code
official, or of a permit or certificate used under provisions of this code, shall be guilty of a
misdemeanor/infraction. The first citation within a 12-month period, for violations of the Fire
Page 343 of 390
Page 5 of 14
Code and any amendments adopted herein shall be treated as a Civil Penalty payable
directly to the City of UkiahUkiah Valley Fire District and is set at $250.00 plus the actual
costs of all inspections required to gain compliance at the current rate set from time to time
by the City of UkiahUkiah Valley Fire District, per hour with a 1 hour minimum. Said civil
penalties shall be a debt owed to the City of UkiahDistrict by the person responsible for the
violation within thirty (30) days after the date of mailing the citation, unless an appeal is filed
as provided in this section. Upon failure to pay the Civil civil penalty when due, the
responsible person shall be liable for civil action brought forth by the City of UkiahUkiah
Valley Fire District for such penalty and costs of the litigation, including reasonable attorney’s
fees.
Any subsequent citations within a twenty-four (24) month period for any violations of the Fire
Code and any amendments adopted herein shall be misdemeanors/infractions, and shall be
subject to the penalties set forth herein, or a civil penalty shall be assessed in the sum of
$500.00 plus the actual costs of all inspections required to gain compliance at the current
rate set from time to time by the City of UkiahUkiah Valley Fire District. The imposition of a
penalty for any violation shall not excuse the violation or permit it to continue and all such
persons shall be required to correct or remedy such violations or defects within a reasonable
time. When not otherwise specified, each day that a violation occurs or continues, after a
final notice has been delivered shall constitute a separate offense. The application of both
penalties shall be held to prevent the enforced correction of the prohibited condition. Nothing
contained in this Section shall be construed or interpreted to prevent the City of UkiahUkiah
Valley Fire District from recovering all costs associated with a Fire Department District
response as described in the City of Ukiah Valley Fire District’s current cost recovery
ordinance, Ordinance 2004-1, or subsequent cost recovery ordinances.
Any violation of any provision of this Chapter shall constitute a public nuisance and shall
entitle the Ukiah Valley Fire District to collect the costs of abatement and related
administrative costs by a nuisance abatement lien as more particularly set forth in
Government Code Section 38773.1, and by special assessment to be collected by the
County Tax Collector as more particularly set forth in Government Code Section 38773.5.
At least thirty (30) days prior to recordation of the lien, or submission of the report to the
Tax Collector for collection of this special assessment, the record owner shall receive
notice from the Chief of the Ukiah Valley Fire District of the intent to charge the property
owner for all administrative costs associated with enforcement of this Ordinance and
abatement of the nuisance. The notice shall include a summary of costs associated with
enforcement of this Ordinance and abatement of the nuisance. The property owner may
appeal the Chief’s decision to the Board of Directors of the Ukiah Valley Fire District within
fifteen (15) days of the date of the notice and request a public hearing prior to recordation
of the lien or submission of the report to the County Tax Collector for collection of the
special assessment. In addition to the foregoing, the Ukiah Valley Fire District is authorized
to prosecute a civil action to collect such abatement costs from the property owner or other
person in possession or control of the affected property and shall be entitled to recover
such abatement costs, together with the cost of litigation, including reasonable attorney’s
fees.
Page 344 of 390
Page 6 of 14
Any person receiving a citation for a civil penalty pursuant to Section 112.3, Violation
Penalties, of Chapter 1, may file an appeal per Section 111.5 through 111.7 of this code
against the imposition of the civil penalty or response costs and expense.
Section 1132.4, Failure to Comply, of Chapter 1 is amended to read as follows:
Section 1132.4 Failure to Comply. Any person who shall continue any work after having
been served with a stop work order, except such work as that person is directed to perform
to remove a violation or unsafe conditions, shall be liable to a fine payable directly to the City
of UkiahUkiah Valley Fire District in the amount of set at not less than $250.00 or more than
$1000.00 plus the actual costs of all inspections required to gain compliance at the rate set
from time to time by the City of UkiahUkiah Valley Fire District, per hour with a 1 hour
minimum. This civil penalty shall be a debt owed to the District by the person responsible for
the violation within thirty (30) days after the date of mailing of the citation unless an appeal
is filed as provided for in Section 108.4.
Section 315.8 Lithium battery storage and handling, of Chapter 3, is hereby added to read
as follows:
315.8 Lithium battery storage and handling. The storage and handling of lithium-ion and
lithium metal batteries or cells in quantities exceeding 1,000 pounds (4086 kg) shall comply
with Sections 315.8.1 through 315.8.10, and Chapter 32 where applicable.
315.8.1 Permits. Permits shall be required as set forth in Section 105.6.27.
315.8.2 Maximum quantity in a fire area. The aggregate amount of lithium batteries
stored and handled in a single fire area shall not exceed 9,000 pounds (4086 kg).
315.8.3 Construction requirements. Fire areas shall be separated from each other by fire
barriers having not less than a 2-hour fire-resistance rating constructed in accordance with
Section 707 of the Building Code and horizontal assemblies constructed in accordance with
Section 711 of the Building Code.
315.8.4 Number of fire areas. The maximum number of fire areas within a building shall
be four.
315.8.5 Group H, Division 2 occupancy. Storage and handling of more than 9,000
pounds of lithium batteries per fire area shall be in an approved Group H, Division 2
occupancy constructed in accordance with the Building Code and provided throughout with
approved automatic smoke detection and radiant-energy detection systems.
315.8.6 Automatic sprinkler system. Buildings containing fire areas used for lithium
battery storage or handling shall be equipped throughout with an approved automatic
sprinkler system in accordance with Section 903.3.1.1. The design of the sprinkler system
within each fire area shall not be less than that required for Extra Hazard Group 2 with a
minimum design area of 2,500 square feet. Where the storage arrangement is required by
other provisions of this code to be provided with a higher level of sprinkler system
protection, the higher level of sprinkler system protection shall be provided.
Page 345 of 390
Page 7 of 14
315.8.7 Automatic smoke detection system. An approved automatic smoke detection
system that activates an approved occupant notification system shall be provided
throughout each fire area in accordance with Section 907.
315.8.8 Radiant energy detection. An approved radiant-energy detection system that
activates an approved occupant notification system shall be installed throughout each fire
area in accordance with Section 907.
315.8.9 Collection containers. Containers used to collect or store lithium batteries shall
be: noncombustible and shall not have an individual capacity exceeding 30 gallons (113.6
L); or be approved for transportation in accordance with the Department of Transportation
(DOT).
315.8.10 Storage configuration. Lithium batteries shall be considered a high-hazard
commodity in accordance with Chapter 32 and where applicable, lithium battery storage
shall comply with Chapter 32 in addition to Section 315.8.
Section 503.3.1, Fire Lane Designation, of Chapter 5 is hereby added to read as follows:
Section 503.3.1 Fire Lane Designation. Where the fire code official determines that it is
necessary to ensure adequate fire access, the fire code official may designate existing
roadways as fire access roadways as provided by Vehicle Code section 22500.1 (public)
or 22658(a) (private).
Section 503.4.2, Roadway Design Features, of Chapter 5 is hereby added to read as follows:
Section 503.4.2 Roadway Design Features. Roadway design features (speed bumps,
speed humps, speed control dips, etc.) which may interfere with emergency apparatus
responses shall not be installed on fire access roadways, unless they meet design criteria
approved by the fire code official.
Section 505.1, Address Identification, of Chapter 5 is hereby amended to read as follows:
Section 505.1 Address Identification. Approved numbers and/or addresses shall be
placed and maintained on all new and existing buildings and at appropriate additional
locations as to be plainly visible and legible from the street or roadway fronting the property
from either direction of approach. Said number shall contrast with their background and shall
meet the minimum standards as to size: 4" high with a 0.5" stroke for residential buildings, 6'
high and a 0.5" stroke for commercial and multi-residential buildings, 12" high with a 1" stroke
for industrial buildings. Additional numbers shall be required where deemed necessary by
the fire code official, such as rear access doors, building corners, and entrances to
commercial centers. The fire code official may establish different minimum sizes for numbers
for various categories of projects.
Section 505.3, Easement Address Signs, of Chapter 5 is hereby added to read as follows:
Section 505.3 Easement Address Signs. All easements, which are not named differently
from the roadway from which they originate, shall have an address sign installed and
Page 346 of 390
Page 8 of 14
maintained, listing all street numbers occurring on that easement, located where the
easement intersects the named roadway. Minimum size of numbers on that sign shall be 4"
in height with a minimum stroke of 0.5" and shall contrast with the background.
Section 505.4, Map Directories, of Chapter 5 is hereby added to read as follows:
Section 505.4 Map Directories. A lighted directory map, meeting current Ffire department
District standards, shall be installed at each driveway entrance to multiple unit residential
projects and mobile home parks, where the numbers of units in such projects exceed 15.
Section 505.5, Response Map Updates, of Chapter 5 is hereby added to read as follows:
Section 505.5 Response Map Updates. Any new development, which necessitates
updating of emergency response maps by virtue of new structures, hydrants, roadways or
similar features, shall be required to provide map updates in a format (PDF and/or CAD
format as approved by the fire code official) or compatible with current department District
mapping services, and shall be charged a reasonable fee for updating all response maps
associated with this development.
Section 506.3, Emergency Electrical Disconnects, of Chapter 5 is hereby added as follows:
Section 506.3 Emergency Electrical Disconnects. Where access to main electrical control
panels requires entry to, and passage through, portions of a structure which may be involved
with fire, smoke, gasses, hazardous materials, or which otherwise present unsafe conditions
to emergency personnel, the fire code official may require that a means of remotely
disconnecting electrical service to the structure be provided. This means of remotely
disconnecting electrical service shall be by a secured key switch mechanism approved by
the fire code officialFire District.
Section 6041201.43.1.1, Alternate Power Sources, of Chapter 6 12 is hereby added to read
as follows:
Section 6041201.4.3.1.1 Alternate Power Sources. All permanent installations of electrical
generators, wind generators, or other power sources shall be approved by the building code
official. All applicable provisions of the National California Electrical Code, the California
Plumbing Code, the Uniform Fuel Gas Code, the California Building Code, California
Residential Code, and this Code shall be followed for any such installation. Permanent
engraved and affixed signage, red in color, reading "WARNING – This premises is provided
with an Alternate Power source, Disconnection of commercial power may not disable the
electric power source." Lettering shall be a minimum of 0.5" tall and shall be permanently
affixed on each electrical panel subject to back-feed form alternate power sources. Any and
all power disabling switches shall be clearly labeled.
Section 903.2, Where required, of Chapter 9 is hereby amended to read as herein provided.
This section shall not amend the portion commencing and following Section 903.2.1.
Page 347 of 390
Page 9 of 14
Section 903.2 Where required. Approved automatic sprinkler systems in new, additions to
existing, remodeled, added to or altered buildings and structures shall be provided in the
locations described in this section.
A. Approved automatic sprinkler systems shall be provided in the new buildings and
structures requiring a fire flow of 2,0001,750 gallons per minute (GPM) or greater as
determined by Appendix B of this code.
B. Approved automatic sprinkler systems shall be provided in addition to existing structures
where the new total building area would require a fire flow of 1,750 2,000 gallons per minute
(GPM) or greater as determined by Appendix B of this code.
C. Approved automatic sprinkler systems shall be provided in existing structures which are
remodeled, added to or altered, except for ordinary maintenance and repair not involving
structural alterations,where improvements occur during any three (3) year period wch meet
the definition of a “substantial remodel” and requiring a fire flow of 2,0001,750 gallons per
minute (GPM) or greater as determined by Appendix B of this code, and when the cost of
such remodels, additions, or alterations within any 36 month period exceeds $60,000.00.
Exception: Projects which are solely complying with statutory regulations (examples may be
Health and Safety Codes, earthquake/seismic, American Disabilities Act (ADA), or façade
improvements) will not trigger this requirement.
D. Approved automatic sprinkler systems shall be provided in new structures exceeding 30
feet in height above lowest grade level.
E. Approved automatic sprinkler systems shall be provided in those new, additions to
existing, remodeled, added to or altered buildings and structures which require a fire flow, as
determined by Appendix B of this code, in excess of the capability of the available water
supply.
F. Approved automatic sprinkler systems shall be installed per 903.3.1.3 in new mobile
homes, and manufactured homes.
G. For purposes of this Section, “substantial remodel” shall mean the alteration of any
structure which combined with any additions to the structure, performed within any three (3)
year period, affects a floor area that exceeds fifty percent (50%) of the existing floor area of
the structure. When any changes are made in the building, such as walls, columns, beams
or girders, floor or ceiling joists and coverings, roof rafters, roof diaphragms, foundations,
piles or retaining walls or similar components, the floor area of all rooms affected by such
changes shall be included in computing floor areas for purposes of applying this definition.
This definition does not apply to the replacement and upgrading of residential roof coverings
or exterior wall finishes.
Section 3313.1, Where required, of Chapter 33 is hereby amended to read as follows:
Section 3313.1 Where required. In buildings required to have standpipes by Section
905.3.1, not less than one standpipe shall be provided for use during construction. Such
Page 348 of 390
Page 10 of 14
standpipes shall be installed during construction for each story above or below the first floor
grade. Such standpipes shall be provided with Ffire department District hose connections at
locations adjacent to stairways complying with Section 3311.1. Such standpipes shall be
extended to the floor of the highest point of construction having secured decking or flooring.
Section Table B105.2, Buildings other than one- and two-family dwellings, of Appendix B is
hereby amended as follows:
AUTOMATIC SPRINKLER
SYSTEM
(Design Standard)
MINIMUM FIRE
FLOW
(gallons per
minute)
FLOW DURATION
(hours)
No automatic sprinkler system Value in Table
B105.1(2)
Duration in Table B105.1(2)
Section 903.3.1.1 of the California
Fire Code
50% of the value in
Table B105.1(2)a
Duration in Table B105.1(2)
at the reduced flow rate
Section 903.3.1.2 of the California
Fire Code
50% of the value in
Table B105.1(2)b
Duration in Table B105.1(2)
at the reduced flow rate
Exceptions:
1. A reduction in required fire-flow of up to 50 percent, as approved, is allowed when the
building is provided with an approved automatic sprinkler system installed in accordance with
Section 903.3.1.1 or 903.3.1.2. The resulting fire-flow shall not be less than 1,500 gallons
per minute (5,678 L/min) for the prescribed duration as specified in Table B105.1.
Section BB105.1, Fire-Flow requirements for buildings, of Appendix BB is hereby amended
as follows:
Section BB105.1 The minimum fire flow and flow duration for school buildings shall be
specified in Table BB105.1.
Exception: A reduction in required fire flow of up to 50 percent is allowed when the building
is provided with an approved sprinkler system.
§5201 DEFINITIONS
In the California Fire Code, herein adopted, the terms used therein shall comply with the
common construction given to and usage of them in the City and as hereinafter defined.
§5202 ENFORCEMENT
A. The California Fire Code (CFC) herein adopted shall be enforced by the Chief of the Fire
Department of the CityUkiah Valley Fire District who is hereby appointed to supervise the
Bureau of Fire Prevention and such regularly employed members of said Districtdepartment
in accordance with the applicable provisions of the California Fire Code.
Page 349 of 390
Page 11 of 14
B. Section 104.3 of the California Fire Code is amended by adding subsection 104.3.2
thereto as follows:
For the purpose of providing and maintaining functions necessary for the prevention of fire
and for the protection of life and property from fire and panic, there is hereby established a
"self-inspection program" assuring that certain California building code (CBC) group B, F, H,
L, M, and S occupancies within the city are inspected on an annual basis for fire safety.
The Ukiah Ffire department District shall deliver, by hand or by mail, "self-inspection
worksheet" and "business and emergency record" forms as established from time to time by
said department District to certain CBC group B, F, H, L, M, & S occupancies within the city
on an annual basis, or as may be initiated through the business license application process.
The owner or manager of said occupancy or person in highest authority in said occupancy
shall be allowed thirty (30) days from issue date, as noted on the self-inspection worksheet,
in which to conduct an inspection for fire safety, correct any deficiencies, complete said
forms, and return completed forms to the Ukiah Valley Fire District Ukiah fire department as
directed by the fire chief or his designee.
Any person who fails to comply with the requirements to return said forms duly completed
and to correct the deficiencies noted in said occupancies within thirty (30) days of the
issuance of said forms shall be guilty of an infraction, punishable by a fine of $100 for a first
offense, $500 for a second offense and $1,000 for a third or subsequent offense.
SECTION TWO.
Article 3 of Chapter 3 in Division 6 of the Ukiah City Code is hereby amended to read
as follows:
* * *
§5216 SECTION 903.2
Section 903.2 (not including sections 903.2.1 and all subsections thereof) of the California
fire code, 2010 edition, is amended to read as follows:
Section 903.2 – Where Required. Approved automatic sprinkler systems in new, additions
to existing, remodeled, added to or altered buildings and structures shall be provided in the
locations described in this section.
A. Approved automatic sprinkler systems shall be provided in new buildings and structures
requiring a fire flow of 2,0001,750 gallons per minute (gpm) or greater as determined by
appendix B of this code.
B. Approved automatic sprinkler systems shall be provided in additions to existing structures
where the new total building area would require a fire flow of 2,0001,750 gallons per minute
(gpm) or greater as determined by appendix B of this code.
Page 350 of 390
Page 12 of 14
C. Approved automatic sprinkler systems shall be provided in existing structures where
improvements occur during any three (3) year period wch meet the definition of a “substantial
remodel” and which are remodeled, added to or altered, except for ordinary maintenance
and repair not involving structural alterations, requiring a fire flow of 2,0001,750 gallons per
minute (gpm) or greater as determined by appendix B of this code, and when the cost of such
remodels, additions, or alterations within any 36 month period exceeds $60,000.
Exception: Projects which are solely complying with statutory regulations (examples may be
health and safety codes, earthquake/seismic, American disabilities act (ADA), or facade
improvements) will not trigger this requirement.
D. Approved automatic sprinkler systems shall be provided in new structures exceeding 30
feet in height above the lowest grade level.
E. Approved automatic sprinkler systems shall be provided in those new, additions to
existing, remodeled, added to or altered buildings and structures which require a fire flow, as
determined by appendix B of this code, in excess of the capability of the available water
supply.
F. Approved automatic sprinkler systems shall be installed per 903.3.1.3 in new mobile
homes, and manufactured homes.
G. For purposes of this Section, “substantial remodel” shall mean the alteration of any
structure which combined with any additions to the structure, performed within any three (3)
year period, affects a floor area that exceeds fifty percent (50%) of the existing floor area of
the structure. When any changes are made in the building, such as walls, columns, beams
or girders, floor or ceiling joists and coverings, roof rafters, roof diaphragms, foundations,
piles or retaining walls or similar components, the floor area of all rooms affected by such
changes shall be included in computing floor areas for purposes of applying this definition.
This definition does not apply to the replacement and upgrading of residential roof coverings
or exterior wall finishes.
* * *
§5218 SECTION 506.3
Section 506.3 of the California fire code, 2010 edition, is added as follows:
Section 506.3 – Emergency Electrical Disconnects.
Where access to main electrical control panels requires entry to, and passage through,
portions of a structure which may be involved with fire, smoke, gasses, hazardous materials,
or which otherwise present unsafe conditions to emergency personnel, the chief may require
that a means of remotely disconnecting electrical service to the structure be provided. This
means of remotely disconnecting electrical service shall be by a secured key switch
mechanism approved by the fire departmentFire District.
* * *
Page 351 of 390
Page 13 of 14
§5223 GEOGRAPHIC LIMITS
That The geographic limits referred to in certain section of the 2019 2022 edition of the
California Fire Code are hereby established as follows:
Section 5704.2.9.6.1 The geographic limits referred to in Section 5704.2.9.6.1 of the 202219
edition of the California Fire Code in which storage of Class I, Class II, and liquids in outside
above ground tanks is prohibited are amended as follows: In all residential areas and in all
heavily populated or congested commercial areas as established by the City of UkiahCounty
of Mendocino, and agricultural land of less than two (2) acres.
Section 5706.2.4.4 The geographic limits referred to in Section 5706.2.4.4 of the 202219
edition of the California Fire Code in which storage of Class I, Class II, and liquids in
aboveground tanks is prohibited are amended as follows: In all residential areas and in all
heavily populated or congested commercial areas as established by the County of
MendocinoCity of Ukiah, and agricultural land of less than two (2) acres.
Section 5806.2 The geographic limits referred to in the 202219 edition of the California Fire
Code in which the storage of flammable cryogenic fluids in stationary containers are
prohibited, are hereby established as follows: In all residential areas and heavily populated
or congested commercial areas, as established by the City of UkiahCounty of Mendocino.
Section 6104.2 The geographic limits referred to in Section 613804.2 of the 202219 edition
of the California Fire Code in which storage of liquefied petroleum gas, the aggregate
capacity of any one installation shall not exceed a water capacity of 2,000 gallons (7,570
liters), is restricted, are amended as follows: In all residential areas and in all heavily
populated or congested commercial areas as established by the City of Ukiah.
§5224 SECTION 7904.4.1.1
Section 7904.4.1.1 is hereby added to the California fire code to read as follows:
Section 7904.4.1.1 – Location Of Bulk Plants.
No bulk plants shall be constructed within the city limits of the city of Ukiah, except if
constructed in accordance with section 7902.2.2.1 of the California fire code.
SECTION TWO.
1. Publication: Within fifteen (15) days after its adoption, this Ordinance shall be published once
in a newspaper of general circulation in the City of Ukiah. In lieu of publishing the full text of the
Ordinance, the City may publish a summary of the Ordinance once 5 days prior to its adoption and
again within fifteen (15) days after its adoption.
2. Effective Date: The ordinance shall become effective thirty (30) days after its adoption.
Introduced by title only on ___________, 2022, by the following roll call vote:
Page 352 of 390
Page 14 of 14
AYES:
NOES:
ABSENT:
ABSTAIN:
Adopted on ___________, 2022, by the following roll call vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
_______________
Jim O. Brown, Mayor
ATTEST:
_______
Kristine Lawler, City Clerk
Page 353 of 390
Page 1 of 13
ORDINANCE NO.X2022-
ORDINANCE OF THE CITY COUNCIL OF THE CITY OF UKIAH AMENDING DIVISION 6,
CHAPTER 3, ARTICLES 1 AND 3, OF THE UKIAH CITY CODE, ENTITLED: FIRE
PREVENTION CODE.
The City Council of the City of Ukiah hereby ordains as follows:
SECTION ONE.
Article 1 of Chapter 3 in Division 6 of the Ukiah City Code is hereby amended to read
as follows (unchanged text is omitted and is shown by “* * *”):
§5200 ADOPTION OF CALIFORNIA FIRE CODE
A certain document, three (3) copies of which are on file in the office of the City Clerk of the
City of Ukiah, being marked and designated as the California Fire Code, 2022 Edition,
including Appendix Chapter 4 and Appendices B, BB, C, CC, D, E, F, G, H, I, K, N and O as
published by the International Code Council, and National Fire Protection Association
(NPFA) 1 Chapter 38, be and is hereby adopted as the Fire Code of the City of Ukiah, in the
State of California regulating and governing the safeguarding of life and property from fire
and explosion hazards arising from the storage, handling and use of hazardous substances,
materials and devices, and from conditions hazardous to life or property in the occupancy of
buildings and premises as herein provided; providing for the issuance of permits and
collection of fees therefor; and each and all of the regulations, provisions, penalties,
conditions and terms of said Fire Code on file in the office of the City Clerk are hereby referred
to, adopted, and made part hereof, as if fully set out in this section, with the additions,
insertions, deletions, and changes, if any, prescribed in Division 6, Chapter 3, Articles 2 and
3 of this code.
§5200.5 INSERTIONS INTO CERTAIN SECTIONS OF THE CALIFORNIA FIRE CODE
2022 EDITION
The following sections of the California Fire Code, 2022 Edition, are hereby amended by
inserting information specific to the City of Ukiah so that these sections read as follows:
101.1 Title. These regulations shall be known as the Fire Code of the City of Ukiah,
hereinafter referred to as "this code."
Section 105.1, General, of Chapter 1 is amended to read as follows:
105.1 General. Permits shall be in accordance with Sections 105.1.1 through 105.6.24 or
other provisions of this code as required by the City of Ukiah.
Section 111.1, Board of Appeals Established, of Chapter 1 is amended to read as follows:
Attachment 2
Page 354 of 390
Page 2 of 13
111.1 Board of Appeals Established. In order to hear and decide appeals of orders,
decisions, or determinations made by the fire code official relative to the application and
interpretation of this code, there shall be and is hereby created a Board of Appeals. The
Board of Appeals shall be the Board of Directors of the Ukiah Valley Fire District or a sub-
committee as appointed by the Board of Directors of the Ukiah Valley Fire District. The fire
code official shall be an ex-officio member of said board but shall have no vote on any
matter before the board. The board shall adopt rules of procedure for conducting its
business and shall render all decisions and findings in writing to the Appellant with a
duplicate copy to the fire code official.
Section 111.3, Qualifications, of Chapter 1 is deleted.
Section 111.5, Appeals Process, of Chapter 1 is added to read as follows:
111.5 Appeals Process. The appeals process for appeals of orders, decisions, or
determinations made by the fire code official relative to the application and interpretation of
this code shall be defined by sections 111.5.1 through 111.5.5.
Section 111.5.1, Initiating Appeal, of Chapter 1 is added to read as follows:
Section 111.5.1 Initiating Appeal. Any beneficially interested party has the right to appeal
the order served by the fire code official by filing a written “NOTICE OF APPEAL” with the
office of the fire code official within ten days after service of such order and upon payment
of the sum of $150. In the event the order of the fire code official is overturned following
the appeal, the fee shall be returned. The notice shall state the order appealed from, the
identity and mailing address of the Appellant, and the specific grounds upon which the
appeal is made.
Section 111.5.2, Stay of Order, of Chapter 1 is added to read as follows:
Section 111.5.2 Stay of Order. The timely filing of a properly completed notice of appeal
shall have the effect of staying the implementation of the order appealed from until the final
decision of the appeal. Failure to file a timely notice of appeal waives any right to further
challenge the order of the fire code official. “File” means delivered to the office of the fire
code official at 300 Seminary Ln, Ukiah, California 95482.
Exception: Orders affecting acts or conditions which in the opinion of the fire code official,
pose an immediate threat to life, property, or the environment as a result of panic, fire,
explosion, or release are enforceable when made and are not stayed by the filing of a
notice of appeal.
Section 111.5.3, Hearing of Appeal, of Chapter 1 is added to read as follows:
Section 111.5.3 Hearing of Appeal. Following is the process for establishing and hearing
appeals:
The Board of Appeals, or the secretary thereof, shall set the matter to be heard at a date
within thirty (30) days of receipt of such notice of appeal. Written notice of the time and
Page 355 of 390
Page 3 of 13
place set for hearing shall be served on the Appellant by first class mail to the mailing
address given in the notice of appeal. A hearing may not be conducted less than 20 days
after notice is given to the applicant. The Board of Appeals may adopt rules governing the
conduct of its hearings. Those rules shall include, at least, the following:
1. The fire code official shall submit evidence at the hearing substantiating his/her
decision. Such evidence may include testimony, fire district, police or other reports of the
incident, witness statements, and other documents. Not less than 10 days prior to the
scheduled hearing, the fire code official must notify the Appellant of the name, address, and
phone number of any witness to the violation and furnish the Appellant with a copy of any
document the fire code official intends to submit at the hearing. Not less than seven (7)
days prior to the hearing, the Appellant may request the fire code official to produce at the
hearing any witness he/she intends to rely upon to substantiate the violation. The written
request must name the witness or witnesses who are requested to attend the hearing. The
fire code official may not rely on the testimony of any witness (including such testimony
contained in reports or written witness statements) whose appearance at the hearing is
required by this subsection if that witness fails to appear.
2. Not less than 10 days prior to the hearing, the Appellant must notify the fire code official
in writing of the name, address, and phone number of any witness the Appellant intends to
call as a witness at the hearing, provide a brief description of the proposed testimony, and
furnish the fire code official with a copy of any document the Appellant intends to offer as
evidence at the hearing. The Appellant may not call any witness to testify at the hearing
who was not identified as required by this subsection or offer any document as evidence at
the hearing that was not provided to the fire code official as required by this subsection.
3. At the hearing, the Appellant may be represented by an attorney, at the Appellant’s
expense. Both the fire code official and the Appellant shall have the right to examine and
cross-examine any witness produced at the hearing. The rules of evidence that normally
apply in court shall not apply in a hearing before the Board of Appeals, but it shall only
consider evidence that would be relied upon by reasonable people making an important
decision, and shall disregard evidence that by its nature is unreliable or not credible.
4. The entire hearing shall be electronically or stenographically recorded. The Board of
Appeals shall base its decision exclusively on the evidence presented at the hearing and
shall issue a written decision, which includes a statement of the relevant facts that it finds to
be true and explains how the facts support its decision. The record of the hearing shall be
preserved for not less than six (6) months after the decision is served on the Appellant.
Section 111.5.4, Hearing Decision, of Chapter 1 is added to read as follows:
Section 111.5.4 Hearing Decision. The chairperson of the Board of Appeals shall issue
the written decision required by subsection 4 of Section 111.4.3 Hearing of appeal. The
Board of Appeals may issue a decision affirming, modifying, or vacating the order of the fire
code official. The decision shall be in writing and shall be served upon the Appellant by
first class mail to the mailing address given in the notice of appeal. The hearing decision
shall include notice of the Appellant’s right to seek review of the decision pursuant to
California Code of Civil Procedure Sections 1094.5 and 1094.6.
Page 356 of 390
Page 4 of 13
Section 111.5.5, Finality of the Decision of the Board of Appeals, of Chapter 1 is added to
read as follows:
Section 111.5.5 Finality of the Decision of the Board of Appeals. The decision of the
Board of Appeals shall be the final decision for the District. The Board of Appeals shall
have the power to continue any hearing and may, at its discretion, take the appeal under
submission. The Board of Appeals shall render a decision not later than the seventh (7th)
day following the date the matter was taken under submission, and forthwith notify the
interested parties as previously set forth.
Section 111.5.6, Appeal to Superior Court, of Chapter 1 is added to read as follows:
Section 111.5.6 Appeal to Superior Court. Judicial review of the decision of the Board of
Appeals shall be governed by the Code of Civil Procedure Sections 1094.5 and 1094.6.
Section 111.5.7, Enforcement of Decision, of Chapter 1 is added to read as follows:
Section 111.5.7 Enforcement of Decision. Unless stayed by a court, any final decision of
the Board of Appeals is effective immediately and may be implemented and enforced by
the District. The remedies provided by this code are cumulative and in addition to any
other remedies available at law or in equity.
1. Causing, permitting, aiding, abetting, or concealing a violation of any provision of this
ordinance shall constitute a violation.
2.Violations of this code are hereby declared to be public nuisances.
3. A violation of this code constitutes a misdemeanor/infraction punishable by a fine of
$1,000 or by imprisonment in the County jail for six months, or both.
4. In addition to other remedies provided by this ordinance or by other law, any violation of
this ordinance may be remedied by a civil action brought by the District, including, for
example, administrative or judicial nuisance abatement proceedings, other legally
authorized enforcement proceedings, and suits for injunctive relief.
Section 112.4, Violation Penalties, of Chapter 1 is amended to read as follows:
Section 112.4 Violation Penalties. Persons who shall violate a provision of this code or
shall fail to comply with any of the requirements thereof or who shall erect, install, alter, repair
or do work in violation of the approved construction documents or directive of the fire code
official, or of a permit or certificate used under provisions of this code, shall be guilty of a
misdemeanor/infraction. The first citation within a 12-month period, for violations of the Fire
Code and any amendments adopted herein shall be treated as a Civil Penalty payable
directly to the Ukiah Valley Fire District and is set at $250.00 plus the actual costs of all
inspections required to gain compliance at the current rate set from time to time by the Ukiah
Valley Fire District, per hour with a 1 hour minimum. Said civil penalties shall be a debt owed
to the District by the person responsible for the violation within thirty (30) days after the date
of mailing the citation, unless an appeal is filed as provided in this section. Upon failure to
Page 357 of 390
Page 5 of 13
pay the civil penalty when due, the responsible person shall be liable for civil action brought
by the Ukiah Valley Fire District for such penalty and costs of the litigation, including
reasonable attorney’s fees.
Any subsequent citations within a twenty-four (24) month period for any violations of the Fire
Code and any amendments adopted herein shall be misdemeanors/infractions, and shall be
subject to the penalties set forth herein, or a civil penalty shall be assessed in the sum of
$500.00 plus the actual costs of all inspections required to gain compliance at the current
rate set from time to time by the Ukiah Valley Fire District. The imposition of a penalty for any
violation shall not excuse the violation or permit it to continue and all such persons shall be
required to correct or remedy such violations or defects within a reasonable time. When not
otherwise specified, each day that a violation occurs or continues, after a final notice has
been delivered shall constitute a separate offense. The application of both penalties shall be
held to prevent the enforced correction of the prohibited condition. Nothing contained in this
Section shall be construed or interpreted to prevent the Ukiah Valley Fire District from
recovering all costs associated with a Fire District response as described in the Ukiah Valley
Fire District’s current cost recovery ordinance, Ordinance 2004-1, or subsequent cost
recovery ordinances.
Any violation of any provision of this Chapter shall constitute a public nuisance and shall
entitle the Ukiah Valley Fire District to collect the costs of abatement and related
administrative costs by a nuisance abatement lien as more particularly set forth in
Government Code Section 38773.1, and by special assessment to be collected by the
County Tax Collector as more particularly set forth in Government Code Section 38773.5.
At least thirty (30) days prior to recordation of the lien, or submission of the report to the
Tax Collector for collection of this special assessment, the record owner shall receive
notice from the Chief of the Ukiah Valley Fire District of the intent to charge the property
owner for all administrative costs associated with enforcement of this Ordinance and
abatement of the nuisance. The notice shall include a summary of costs associated with
enforcement of this Ordinance and abatement of the nuisance. The property owner may
appeal the Chief’s decision to the Board of Directors of the Ukiah Valley Fire District within
fifteen (15) days of the date of the notice and request a public hearing prior to recordation
of the lien or submission of the report to the County Tax Collector for collection of the
special assessment. In addition to the foregoing, the Ukiah Valley Fire District is authorized
to prosecute a civil action to collect such abatement costs from the property owner or other
person in possession or control of the affected property and shall be entitled to recover
such abatement costs, together with the cost of litigation, including reasonable attorney’s
fees.
Any person receiving a citation for a civil penalty pursuant to Section 112.3, Violation
Penalties, of Chapter 1, may file an appeal per Section 111.5 through 111.7 of this code
against the imposition of the civil penalty or response costs and expense.
Section 113.4, Failure to Comply, of Chapter 1 is amended to read as follows:
Section 113.4 Failure to Comply. Any person who shall continue any work after having
been served with a stop work order, except such work as that person is directed to perform
to remove a violation or unsafe conditions, shall be liable to a fine payable directly to the
Page 358 of 390
Page 6 of 13
Ukiah Valley Fire District in the amount set at not less than $250.00 or more than $1000.00
plus the actual costs of all inspections required to gain compliance at the rate set from time
to time by the Ukiah Valley Fire District. This civil penalty shall be a debt owed to the District
by the person responsible for the violation within thirty (30) days after the date of mailing of
the citation unless an appeal is filed as provided for in Section 108.4.
Section 315.8 Lithium battery storage and handling, of Chapter 3, is hereby added to read
as follows:
315.8 Lithium battery storage and handling. The storage and handling of lithium-ion and
lithium metal batteries or cells in quantities exceeding 1,000 pounds (4086 kg) shall comply
with Sections 315.8.1 through 315.8.10, and Chapter 32 where applicable.
315.8.1 Permits. Permits shall be required as set forth in Section 105.6.27.
315.8.2 Maximum quantity in a fire area. The aggregate amount of lithium batteries
stored and handled in a single fire area shall not exceed 9,000 pounds (4086 kg).
315.8.3 Construction requirements. Fire areas shall be separated from each other by fire
barriers having not less than a 2-hour fire-resistance rating constructed in accordance with
Section 707 of the Building Code and horizontal assemblies constructed in accordance with
Section 711 of the Building Code.
315.8.4 Number of fire areas. The maximum number of fire areas within a building shall
be four.
315.8.5 Group H, Division 2 occupancy. Storage and handling of more than 9,000
pounds of lithium batteries per fire area shall be in an approved Group H, Division 2
occupancy constructed in accordance with the Building Code and provided throughout with
approved automatic smoke detection and radiant-energy detection systems.
315.8.6 Automatic sprinkler system. Buildings containing fire areas used for lithium
battery storage or handling shall be equipped throughout with an approved automatic
sprinkler system in accordance with Section 903.3.1.1. The design of the sprinkler system
within each fire area shall not be less than that required for Extra Hazard Group 2 with a
minimum design area of 2,500 square feet. Where the storage arrangement is required by
other provisions of this code to be provided with a higher level of sprinkler system
protection, the higher level of sprinkler system protection shall be provided.
315.8.7 Automatic smoke detection system. An approved automatic smoke detection
system that activates an approved occupant notification system shall be provided
throughout each fire area in accordance with Section 907.
315.8.8 Radiant energy detection. An approved radiant-energy detection system that
activates an approved occupant notification system shall be installed throughout each fire
area in accordance with Section 907.
Page 359 of 390
Page 7 of 13
315.8.9 Collection containers. Containers used to collect or store lithium batteries shall
be: noncombustible and shall not have an individual capacity exceeding 30 gallons (113.6
L); or be approved for transportation in accordance with the Department of Transportation
(DOT).
315.8.10 Storage configuration. Lithium batteries shall be considered a high-hazard
commodity in accordance with Chapter 32 and where applicable, lithium battery storage
shall comply with Chapter 32 in addition to Section 315.8.
Section 503.3.1, Fire Lane Designation, of Chapter 5 is hereby added to read as follows:
Section 503.3.1 Fire Lane Designation. Where the fire code official determines that it is
necessary to ensure adequate fire access, the fire code official may designate existing
roadways as fire access roadways as provided by Vehicle Code section 22500.1 (public)
or 22658(a) (private).
Section 503.4.2, Roadway Design Features, of Chapter 5 is hereby added to read as follows:
Section 503.4.2 Roadway Design Features. Roadway design features (speed bumps,
speed humps, speed control dips, etc.) which may interfere with emergency apparatus
responses shall not be installed on fire access roadways, unless they meet design criteria
approved by the fire code official.
Section 505.1, Address Identification, of Chapter 5 is hereby amended to read as follows:
Section 505.1 Address Identification. Approved numbers and/or addresses shall be
placed and maintained on all new and existing buildings and at appropriate additional
locations as to be plainly visible and legible from the street or roadway fronting the property
from either direction of approach. Said number shall contrast with their background and shall
meet the minimum standards as to size: 4" high with a 0.5" stroke for residential buildings, 6'
high and a 0.5" stroke for commercial and multi-residential buildings, 12" high with a 1" stroke
for industrial buildings. Additional numbers shall be required where deemed necessary by
the fire code official, such as rear access doors, building corners, and entrances to
commercial centers. The fire code official may establish different minimum sizes for numbers
for various categories of projects.
Section 505.3, Easement Address Signs, of Chapter 5 is hereby added to read as follows:
Section 505.3 Easement Address Signs. All easements, which are not named differently
from the roadway from which they originate, shall have an address sign installed and
maintained, listing all street numbers occurring on that easement, located where the
easement intersects the named roadway. Minimum size of numbers on that sign shall be 4"
in height with a minimum stroke of 0.5" and shall contrast with the background.
Section 505.4, Map Directories, of Chapter 5 is hereby added to read as follows:
Page 360 of 390
Page 8 of 13
Section 505.4 Map Directories. A lighted directory map, meeting current Fire District
standards, shall be installed at each driveway entrance to multiple unit residential projects
and mobile home parks, where the numbers of units in such projects exceed 15.
Section 505.5, Response Map Updates, of Chapter 5 is hereby added to read as follows:
Section 505.5 Response Map Updates. Any new development, which necessitates
updating of emergency response maps by virtue of new structures, hydrants, roadways or
similar features, shall be required to provide map updates in a format (PDF and/or CAD
format as approved by the fire code official) or compatible with current District mapping
services, and shall be charged a reasonable fee for updating all response maps associated
with this development.
Section 506.3, Emergency Electrical Disconnects, of Chapter 5 is hereby added as follows:
Section 506.3 Emergency Electrical Disconnects. Where access to main electrical control
panels requires entry to, and passage through, portions of a structure which may be involved
with fire, smoke, gasses, hazardous materials, or which otherwise present unsafe conditions
to emergency personnel, the fire code official may require that a means of remotely
disconnecting electrical service to the structure be provided. This means of remotely
disconnecting electrical service shall be by a secured key switch mechanism approved by
the Fire District.
Section 1201.4, Alternate Power Sources, of Chapter 12 is hereby added to read as follows:
Section 1201.4Alternate Power Sources. All permanent installations of electrical
generators, wind generators, or other power sources shall be approved by the building code
official. All applicable provisions of the California Electrical Code, the California Plumbing
Code, the California Building Code, California Residential Code, and this Code shall be
followed for any such installation. Permanent engraved and affixed signage, red in color,
reading "WARNING – This premises is provided with an Alternate Power source,
Disconnection of commercial power may not disable the electric power source." Lettering
shall be a minimum of 0.5" tall and shall be permanently affixed on each electrical panel
subject to back-feed form alternate power sources. Any and all power disabling switches
shall be clearly labeled.
Section 903.2, Where required, of Chapter 9 is hereby amended to read as herein provided.
This section shall not amend the portion commencing and following Section 903.2.1.
Section 903.2 Where required. Approved automatic sprinkler systems in new, additions to
existing, remodeled, added to or altered buildings and structures shall be provided in the
locations described in this section.
A. Approved automatic sprinkler systems shall be provided in the new buildings and
structures requiring a fire flow of 1,750 gallons per minute (GPM) or greater as determined
by Appendix B of this code.
Page 361 of 390
Page 9 of 13
B. Approved automatic sprinkler systems shall be provided in addition to existing structures
where the new total building area would require a fire flow of 1,750 gallons per minute (GPM)
or greater as determined by Appendix B of this code.
C. Approved automatic sprinkler systems shall be provided in existing structures where
improvements occur during any three (3) year period wch meet the definition of a “substantial
remodel” and requiring a fire flow of 1,750 gallons per minute (GPM) or greater as determined
by Appendix B of this code.
Exception: Projects which are solely complying with statutory regulations (examples may be
Health and Safety Codes, earthquake/seismic, American Disabilities Act (ADA), or façade
improvements) will not trigger this requirement.
D. Approved automatic sprinkler systems shall be provided in new structures exceeding 30
feet in height above lowest grade level.
E. Approved automatic sprinkler systems shall be provided in those new, additions to
existing, remodeled, added to or altered buildings and structures which require a fire flow, as
determined by Appendix B of this code, in excess of the capability of the available water
supply.
F. Approved automatic sprinkler systems shall be installed per 903.3.1.3 in new mobile
homes, and manufactured homes.
G. For purposes of this Section, “substantial remodel” shall mean the alteration of any
structure which combined with any additions to the structure, performed within any three (3)
year period, affects a floor area that exceeds fifty percent (50%) of the existing floor area of
the structure. When any changes are made in the building, such as walls, columns, beams
or girders, floor or ceiling joists and coverings, roof rafters, roof diaphragms, foundations,
piles or retaining walls or similar components, the floor area of all rooms affected by such
changes shall be included in computing floor areas for purposes of applying this definition.
This definition does not apply to the replacement and upgrading of residential roof coverings
or exterior wall finishes.
Section 3313.1, Where required, of Chapter 33 is hereby amended to read as follows:
Section 3313.1 Where required. In buildings required to have standpipes by Section
905.3.1, not less than one standpipe shall be provided for use during construction. Such
standpipes shall be installed during construction for each story above or below the first floor
grade. Such standpipes shall be provided with Fire District hose connections at locations
adjacent to stairways complying with Section 3311.1. Such standpipes shall be extended to
the floor of the highest point of construction having secured decking or flooring.
Table B105.2, Buildings other than one- and two-family dwellings, of Appendix B is hereby
amended as follows:
AUTOMATIC SPRINKLER
SYSTEM
MINIMUM FIRE
FLOW
FLOW DURATION
(hours)
Page 362 of 390
Page 10 of 13
(Design Standard) (gallons per
minute)
No automatic sprinkler system Value in Table
B105.1(2)
Duration in Table B105.1(2)
Section 903.3.1.1 of the California
Fire Code
50% of the value in
Table B105.1(2)a
Duration in Table B105.1(2)
at the reduced flow rate
Section 903.3.1.2 of the California
Fire Code
50% of the value in
Table B105.1(2)b
Duration in Table B105.1(2)
at the reduced flow rate
Section BB105.1, Fire-Flow requirements for buildings, of Appendix BB is hereby amended
as follows:
Section BB105.1 The minimum fire flow and flow duration for school buildings shall be
specified in Table BB105.1.
Exception: A reduction in required fire flow of up to 50 percent is allowed when the building
is provided with an approved sprinkler system.
§5201 DEFINITIONS
In the California Fire Code, herein adopted, the terms used therein shall comply with the
common construction given to and usage of them in the City and as hereinafter defined.
§5202 ENFORCEMENT
A. The California Fire Code (CFC) herein adopted shall be enforced by the Chief of the
Ukiah Valley Fire District who is hereby appointed to supervise the Bureau of Fire Prevention
and such regularly employed members of said Districtt in accordance with the applicable
provisions of the California Fire Code.
B. Section 104.3 of the California Fire Code is amended by adding subsection 104.3.2
thereto as follows:
For the purpose of providing and maintaining functions necessary for the prevention of fire
and for the protection of life and property from fire and panic, there is hereby established a
"self-inspection program" assuring that certain California building code (CBC) group B, F, H,
L, M, and S occupancies within the city are inspected on an annual basis for fire safety.
The Ukiah Fire District shall deliver, by hand or by mail, "self-inspection worksheet" and
"business and emergency record" forms as established from time to time by said District to
certain CBC group B, F, H, L, M, & S occupancies within the city on an annual basis, or as
may be initiated through the business license application process.
The owner or manager of said occupancy or person in highest authority in said occupancy
shall be allowed thirty (30) days from issue date, as noted on the self-inspection worksheet,
in which to conduct an inspection for fire safety, correct any deficiencies, complete said
Page 363 of 390
Page 11 of 13
forms, and return completed forms to the Ukiah Valley Fire District as directed by the fire
chief or his designee.
Any person who fails to comply with the requirements to return said forms duly completed
and to correct the deficiencies noted in said occupancies within thirty (30) days of the
issuance of said forms shall be guilty of an infraction, punishable by a fine of $100 for a first
offense, $500 for a second offense and $1,000 for a third or subsequent offense.
SECTION TWO.
Article 3 of Chapter 3 in Division 6 of the Ukiah City Code is hereby amended to read
as follows:
* * *
§5216 SECTION 903.2
Section 903.2 (not including sections 903.2.1 and all subsections thereof) of the California
fire code, 2010 edition, is amended to read as follows:
Section 903.2 – Where Required. Approved automatic sprinkler systems in new, additions
to existing, remodeled, added to or altered buildings and structures shall be provided in the
locations described in this section.
A. Approved automatic sprinkler systems shall be provided in new buildings and structures
requiring a fire flow of 1,750 gallons per minute (gpm) or greater as determined by appendix
B of this code.
B. Approved automatic sprinkler systems shall be provided in additions to existing structures
where the new total building area would require a fire flow of 1,750 gallons per minute (gpm)
or greater as determined by appendix B of this code.
C. Approved automatic sprinkler systems shall be provided in existing structures where
improvements occur during any three (3) year period wch meet the definition of a “substantial
remodel” and requiring a fire flow of 1,750 gallons per minute (gpm) or greater as determined
by appendix B of this code.
Exception: Projects which are solely complying with statutory regulations (examples may be
health and safety codes, earthquake/seismic, American disabilities act (ADA), or facade
improvements) will not trigger this requirement.
D. Approved automatic sprinkler systems shall be provided in new structures exceeding 30
feet in height above the lowest grade level.
E. Approved automatic sprinkler systems shall be provided in those new, additions to
existing, remodeled, added to or altered buildings and structures which require a fire flow, as
determined by appendix B of this code, in excess of the capability of the available water
supply.
Page 364 of 390
Page 12 of 13
F. Approved automatic sprinkler systems shall be installed per 903.3.1.3 in new mobile
homes, and manufactured homes.
G. For purposes of this Section, “substantial remodel” shall mean the alteration of any
structure which combined with any additions to the structure, performed within any three (3)
year period, affects a floor area that exceeds fifty percent (50%) of the existing floor area of
the structure. When any changes are made in the building, such as walls, columns, beams
or girders, floor or ceiling joists and coverings, roof rafters, roof diaphragms, foundations,
piles or retaining walls or similar components, the floor area of all rooms affected by such
changes shall be included in computing floor areas for purposes of applying this definition.
This definition does not apply to the replacement and upgrading of residential roof coverings
or exterior wall finishes.
* * *
§5218 SECTION 506.3
Section 506.3 of the California fire code, 2010 edition, is added as follows:
Section 506.3 – Emergency Electrical Disconnects.
Where access to main electrical control panels requires entry to, and passage through,
portions of a structure which may be involved with fire, smoke, gasses, hazardous materials,
or which otherwise present unsafe conditions to emergency personnel, the chief may require
that a means of remotely disconnecting electrical service to the structure be provided. This
means of remotely disconnecting electrical service shall be by a secured key switch
mechanism approved by the Fire District.
* * *
§5223 GEOGRAPHIC LIMITS
The geographic limits referred to in certain section of the 2022 edition of the California Fire
Code are hereby established as follows:
Section 5704.2.9.6.1 The geographic limits referred to in Section 5704.2.9.6.1 of the 2022
edition of the California Fire Code in which storage of Class I, Class II, and liquids in outside
above ground tanks is prohibited are amended as follows: In all residential areas and in all
heavily populated or congested commercial areas as established by the County of
Mendocino, and agricultural land of less than two (2) acres.
Section 5706.2.4.4 The geographic limits referred to in Section 5706.2.4.4 of the 2022
edition of the California Fire Code in which storage of Class I, Class II, and liquids in
aboveground tanks is prohibited are amended as follows: In all residential areas and in all
heavily populated or congested commercial areas as established by the County of
Mendocino, and agricultural land of less than two (2) acres.
Page 365 of 390
Page 13 of 13
Section 5806.2 The geographic limits referred to in the 2022 edition of the California Fire
Code in which the storage of flammable cryogenic fluids in stationary containers are
prohibited, are hereby established as follows: In all residential areas and heavily populated
or congested commercial areas, as established by the County of Mendocino.
Section 6104.2 The geographic limits referred to in Section 6104.2 of the 2022 edition of the
California Fire Code in which storage of liquefied petroleum gas, the aggregate capacity of
any one installation shall not exceed a water capacity of 2,000 gallons (7,570 liters), is
restricted, are amended as follows: In all residential areas and in all heavily populated or
congested commercial areas as established by the City of Ukiah.
SECTION TWO.
1. Publication: Within fifteen (15) days after its adoption, this Ordinance shall be
published once in a newspaper of general circulation in the City of Ukiah. In lieu of publishing
the full text of the Ordinance, the City may publish a summary of the Ordinance once 5 days
prior to its adoption and again within fifteen (15) days after its adoption.
2. Effective Date: The ordinance shall become effective thirty (30) days after its adoption.
Introduced by title only on ___________, 2022, by the following roll call vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
Adopted on ___________, 2022, by the following roll call vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
_______________
Jim O. Brown, Mayor
ATTEST:
_______
Kristine Lawler, City Clerk
Page 366 of 390
Page 1 of 2
Agenda Item No: 13.b.
MEETING DATE/TIME: 11/2/2022
ITEM NO: 2022-2118
AGENDA SUMMARY REPORT
SUBJECT: Receive Updates on City Council Committee and Ad Hoc Assignments, and, if Necessary,
Consider Modifications to Assignments and/or the Creation/Elimination of Ad Hoc(s); Including Consideration
of Adoption of Resolution Appointed a Member and an Alternate Member to the Ukiah Valley Basin
Groundwater Sustainability Agency (UVBGSA).
DEPARTMENT: City Clerk PREPARED BY: Kristine Lawler, City Clerk
PRESENTER: Mayor Brown, various Councilmembers, and
Sean White, Water Resources Director.
ATTACHMENTS:
1. 2022 City Council Special Assignments
2. Ukiah Valley Basin GSA JPA
3. UVBGSA Appointing Resolution 2022
Summary: City Council members will provide reports and updates on their committee and ad hoc
assignments. If necessary, the Council may consider modifications. Council will also consider adopting a
resolution appointing a Member and an Alternate Member to the Ukiah Valley Basin Groundwater
Sustainability Agency (UVBGSA).
Background: City Council members are assigned to a number of committees and ad hoc activities. These
assignments are included as Attachment 1.
Discussion: Previously, the City Council discussed having more time allocated to reporting on committee and
ad hoc activities. Often, the Council Reports section of the regular agenda is rushed due to impending
business (i.e., public hearings), and not enough time is afforded for reports beyond community activities.
In an effort to foster regular updates on committee and ad hoc assignments, this item is being placed on the
agenda to provide the City Council members an expanded opportunity to report on assignments and modify
assignments as necessary.
Ukiah Valley Basin Groundwater Sustainability Agency
As a Member of the Ukiah Valley Basin Groundwater Sustainability Agency (UVBGSA), the City Council is
required to nominate a Director and an Alternate Director to be appointed to serve a term of two years from
2023-2025. The current board member seats for Director and Alternate-Director were last confirmed in
February of 2021.
The Appointment Process is defined in the UVBGSA JPA (Attachment 2) section 7.3.1. Member Directors:
Each Member Director must sit on the governing board of the [participating] Member [being City of Ukiah] and
be appointed by that governing board by Resolution (Attachment 3), which shall be transmitted to the
Secretary of the Agency following adoption.
The UVBGSA will be holding their first Board Meeting on the first meeting following January 1, 2023, and plan
to present the Member Directors at that meeting. Therefore, Staff is recommending that Council reappoint the
Page 367 of 390
Page 2 of 2
City's existing representatives or consider alternatives if desired. Currently Councilmember Crane serves as
the primary, and Vice Mayor Duenas serves in the alternate position.
Recommended Action: 1. Receive report(s). The Council will consider modifications to committee and ad
hoc assignments along with the creation/elimination ad hoc(s).
2. Adopt Resolution appointing a Member and an Alternate Member to the Ukiah Valley Basin Groundwater
Sustainability Agency (UVBGSA).
BUDGET AMENDMENT REQUIRED: No
CURRENT BUDGET AMOUNT: N/A
PROPOSED BUDGET AMOUNT: N/A
FINANCING SOURCE: N/A
PREVIOUS CONTRACT/PURCHASE ORDER NO.: N/A
COORDINATED WITH: N/A
Page 368 of 390
2022 CITY COUNCIL SPECIAL ASSIGNMENTS
COUNTY/REGIONAL
OnGoing One + Alternate MTG DATE/TIME MEETING LOCATION MAILING ADDRESS/CONTACT COMMITTEE FUNCTION ASSIGNED TO PRINCIPAL STAFF SUPPORT
Disaster Council
Shall meet a minimum
of once a year at a
time and place
designated upon call of
the chair
Place designated upon call of the
chair or, if she/he is unavailable or
unable to call such meeting, the first
vice chair and then the City Manager
or her/his designee.
Office of Emergency Management
300 Seminary Ave.
Ukiah, CA 95482
467-5765 - Tami Bartolomei
Develop any necessary emergency and mutual aid
plans, agreements, ordinances, resolutions, rules, and
regulations.
Orozco
Duenas- Alternate
Tami Bartolomei, Office of Emergency
Management Coordinator; 467-5765
tbartolomei@cityofukiah.com
Greater Ukiah Business & Tourism
Alliance
3rd Tuesday of month,
11:30 a.m.
200 S School St.
Ukiah, CA 95482
200 S School St.
Ukiah, CA 95482
Promotes tourism and works to strengthen and promote
the historic downtown and businesses within the greater
Ukiah area
Duenas
Rodin - Alternate
Shannon Riley,Deputy City Manager;
467-5793 sriley@cityofukiah.com
Mendocino Council of Governments
(MCOG)
1st Monday of month,
1:30 p.m.
Board of Supervisors Chambers
501 Low Gap Road
Ukiah, CA
Executive Director
367 N. State Street, Ste. 206
Ukiah, CA 95482
463-1859
Plan and allocate State funding, transportation,
infrastructure and project County wide
Brown
Rodin- Alternate
Tim Eriksen, Public Works Director/City
Engineer; 463-6280 teriksen@cityofukiah.com
Mendocino County Inland Water and
Power Commission (IWPC)
2nd Thursday of
month, 6:00 p.m.
Civic Center
300 Seminary Avenue
conference room 5
IWPC Staff
P.O. Box 1247
Ukiah, CA 95482
391-7574 - Candace Horsley
Develops coordination for water resources and current
water rights: Potter Valley project - Eel River Diversion
Orozco
Brown- Alternate
Sean White,Director of Water Resources;
463-5712 swhite@cityofukiah.com
Mendocino Solid Waste Management
Authority (MSWMA)
3rd Thursday of every
other month (varies),
10:00 a.m.
Willits Council Chambers
Solid Waste Director
3200 Taylor Drive
Ukiah, CA 95482
468-9710
County-wide Solid Waste JPA Brown
Duenas- Alternate
Tim Eriksen, Public Works Director/City
Engineer; 463-6280 teriksen@cityofukiah.com
Mendocino Transit Authority (MTA)
Board of Directors
Last Wednesday of
month, 1:30 p.m.
Alternating locations - Ukiah
Conference Center or Fort Bragg, or
Point Arena
Executive Director
241 Plant Road
Ukiah, CA 95482
462-1422
County-wide bus transportation issues and funding Duenas Orozco -
Alternate
Tim Eriksen, Public Works Director/City
Engineer; 463-6280 teriksen@cityofukiah.com
North Coast Opportunities (NCO)4th Wednesday of
month, 2 p.m.
Alternating locations - Ukiah and
Lakeport
Ross Walker, Governing Board Chair
North Coast Opportunities
413 North State Street
Ukiah, CA 95482
Assist low income and disadvantaged people to become
self reliant Burgess
Jake Burgess, Community Services Supervisor;
463-6201
jburgess@cityofukiah.com
North Coast Rail Authority (NCRA)2nd Wednesday of
month, 10:30 a.m.Various Locations - announced
419 Talmage Road, Suite M
Ukiah, CA 95482
463-3280
Provides a unified and revitalized rail infrastructure
meeting the freight and passenger needs of the region
Shannon Riley, Deputy
City Manager Shannon Riley,Deputy City Manager;
467-5793 sriley@cityofukiah.com
Russian River Watershed Association
(RRWA)
4th Thursday of month,
9:00 a.m. (only 5 times
a year)
Windsor Town Hall
Russian River Watershed Association
Attn: Daria Isupov
425 South Main St., Sebastopol, CA
95472
508-3670
Consider issues related to Russian river - plans projects
and funding requests
Rodin
Brown- Alternate
Tim Eriksen, Public Works Director/City
Engineer;463-6280 teriksen@cityofukiah.com
Ukiah Valley Basin Groundwater
Sustainability Agency (GSA)
2nd Thursday of
month, 1:30 p.m.
Board of Supervisors Chambers; 501
Low Gap Road
Ukiah, CA
County Executive Office
Nicole French
501 Low Gap Rd., Rm. 1010
Ukiah, CA 95482
463-4441
GSA serves as the Groundwater Sustainability Agency in
the Ukiah Valley basin
Crane
Duenas- Alternate
Sean White, Director of Water Resources;
463-5712 swhite@cityofukiah.com
COUNTY/REGIONAL
One + Staff Alternate MTG DATE/TIME MEETING LOCATION MAILING ADDRESS/CONTACT COMMITTEE FUNCTION ASSIGNED TO PRINCIPAL STAFF SUPPORT
Economic Development & Financing
Corporation (EDFC)
2nd Thursday of
month, 2:00 p.m.
Primarily 631 S. Orchard Street
(location varies)
Executive Director
631 South Orchard Avenue
Ukiah, CA 95482
467-5953
Multi-agency co-op for economic development and
business loan program
Riley
(appointed 12/19/18)
Shannon Riley, Deputy City Manager;
467-5793 sriley@cityofukiah.com
Sun House Guild ex officio 2nd Tuesday of month,
4:30 p.m.
Sun House
431 S. Main St.
Ukiah, CA
431 S. Main Street
Ukiah, CA 95482
467-2836
Support and expand Grace Hudson Museum Orozco Neil
Davis- Alternate
David Burton, Museum Director; 467-2836
dburton@cityofukiah.com
Continued -
COUNTY/REGIONAL
One + Staff Alternate
MTG DATE/TIME MEETING LOCATION MAILING ADDRESS/CONTACT COMMITTEE FUNCTION ASSIGNED TO PRINCIPAL STAFF SUPPORT
Mendocino Youth Project JPA Board of
Directors
3rd Wednesday of
month, 7:45 a.m.776 S. State Street Conference Room
Mendocino Co. Youth Project
776 S. State Street, Ste. 107
Ukiah, CA 95482
707-463-4915
Targets all youth with a focus on drug and alcohol
prevention, healthy alternatives and empowering youth
to make healthy choices
Cedric Crook, Patrol
Lieutenant
Cedric Crook, Patrol Lieutenant Nob; 463-6771;
ccrook@cityofukiah.com
Northern California Power Agency
(NCPA) - Commission
4th Thursday of month,
9:00 a.m. (see NCPA
calendar)
Roseville, CA
and other locations
651 Commerce Drive
Roseville, CA 95678
916-781-4202
Pool of State and local power utilities developing and
operating power generation, providing scheduling and
related energy services and providing regulatory and
legislative support.
Crane - Commissioner
Sauers - Alternate and
Commissioner in absence of
Commissioner Crane
Cindi Sauers - Electric Utility Director;
463-6286 csauers@cityofukiah.com
Northern California Power Agency
(NCPA) – Lodi Energy Center (LEC)
Appointment
2nd Monday of
month, 10:00 AM Lodi, CA and other locations
651 Commerce Drive
Roseville, CA 95678
916-781-4299
Committee oversees the operation, maintenance and
expenditures of the LEC 300 MW generating project.
Sauers – Project Participate
Appointee
Cindy Sauers, Electric Utility Director,
463‐6286, csauers@cityofukiah.com
Transmission Agency of Northern
California (TANC)
4th Wednesday of
month, 10 a.m.
35 Iron Point Circle Suite 225 Folsom,
CA
35 Iron Point Cir #225
Folsom, CA 95630
916-852-1673; info@tanc.us
Provide electric transmission to its Member utilities
through transmission line ownership or contract
arrangements.
Crane
Sauers - Alternate
Cindi Sauers - Electric Utility Director;
463-6286 csauers@cityofukiah.com
1 9/8/2022
ATTACHMENT 1
Page 369 of 390
2022 CITY COUNCIL SPECIAL ASSIGNMENTS
LOCAL/COUNTY/REGIONAL/LIASONS
OnGoing One or Two Council and/or
Staff
MTG DATE/TIME LOCATION MAILING ADDRESS/CONTACT COMMITTEE FUNCTION ASSIGNED TO PRINCIPAL STAFF SUPPORT
League of California Cities Redwood
Empire Legislative Committee
Prior to Division
Meetings, meets 3x in
person and then via
conference call
Various locations that are announced
Redwood Empire League President;
Public Affairs Program Manager
(916) 658-8243
Elected city officials and professional city staff attend
division meetings throughout the year to share what they
are doing and advocate for their interests in Sacramento
Rodin
Orozco-Alternate
Sage Sangiacomo, City Manager; 463-6221
ssangiacomo@cityofukiah.com
City Selection Committee Called as required by
the Clerk of the Board
BOS Conference Room
501 Low Gap Rd. Rm. 1090
Ukiah, CA
C/O: BOS
501 Low Gap Rd., Rm 1090
Ukiah, CA 95482
463-4441
Makes appointments to LAFCO and Airport Land Use
Commission Mayor Kristine Lawler, City Clerk; 463-6217
klawler@cityofukiah.com
Investment Oversight Committee Varies
Civic Center
300 Seminary Ave.
Ukiah, CA 95482
Civic Center
300 Seminary Ave.
Ukiah, CA 95482
Reviews City investments, policies, and strategies
Crane
Orozco, Alternate
Alan Carter, Treasurer
Dan Buffalo, Director of Finance; 463-6220
dbuffalo@cityofukiah.com
Library Advisory Board
3rd Wednesdays of
alternate months; 1:00
p.m.
Various Mendocino County Libraries Ukiah County Library
463-4491 Review library policy and activities Supervisor Mulheren Kristine Lawler, City Clerk; 463-6217;
klawler@cityofukiah.com
Ukiah Players Theater Board of Directors 3rd Tuesday of month,
6:00 p.m
1041 Low Gap Rd
Ukiah, CA 95482
462-1210
1041 Low Gap Rd
Ukiah, CA 95482
462-1210
To oversee the activities, organization and purpose of
the Ukiah Players Theater
Greg Owen, Airport
Manager
(appointed 12/19/18)
Kristine Lawler, City Clerk; 463-6217
klawler@cityofukiah.com
Ukiah Unified School District (UUSD)
Committee Quarterly 511 S. Orchard, Ste. D
Ukiah, CA 95482
511 S. Orchard
Ukiah, CA 95482
Information exchange with UUSD Board Chair, Mayor,
Superintendent, and City Manager
Mayor, City Manager and
Police Chief
Sage Sangiacomo, City Manager; 463-6221
ssangiacomo@cityofukiah.com
Russian River Flood Control District
(RRFCD) Liaison
1st Monday of month,
5:30 p.m.
151 Laws Ave.,Suite D
Ukiah, CA
151 Laws Ave., Ukiah, CA 95482;
rrfc@pacific.net; 462-5278
Proactively manage the water resources of the upper
Russian River for the benefit of the people and
environment of Mendocino County
White/Orozco Sean White, Director of Water Resources;
463-5712 swhite@cityofukiah.com
Mendocino County Local Area
Formation Commission (LAFCO)
1st Monday of month,
9:00 a.m.Board of Supervisors Chambers
Executive Director
200 S. School Street, Ste. 2
Ukiah, CA 95482
463-4470
Required by legislation - planning spheres of influence,
annexation, service areas, and special districts Rodin/Crane
Craig Schlatter, Director of Community
Development; 463-6219;
cschlatter@cityofukiah.com
Mendocino County Airport Land Use
Commission As needed
BOS Conference Room
501 Low Gap Rd., Rm. 1090,
Ukiah, CA
Mendocino County Executive Office
501 Low Gap Rd. Rm. 1010
Ukiah, CA 95482
To formulate a land use compatibility plan, provide for
the orderly growth of the airport and the surrounding
area, and safeguard the general welfare of the
inhabitants within the vicinity
Owen/Schlatter
Greg Owen, Airport Manager; 467-2855;
gowen@cityofukiah.com
Craig Schlatter, Director of Community
Development; 463-6219;
cschlatter@cityofukiah.com
Mendocino County 1st District Liaison Monthly; TBD
Civic Center Annex
conference room #5
411 West Clay St.
Ukiah, CA 95482
Civic Center
300 Seminary Ave.
Ukiah, CA 95482
To coordinate activities and policy development with the
City's 1st District Supervisor
Brown
Crane- Alternate
Sage Sangiacomo, City Manager;
463-6221; ssangiacomo@cityofukiah.com
Mendocino County 2nd District Liaison 1st Wednesdays of
month, 8:00 a.m.
Civic Center Annex
conference room #5
411 West Clay St.
Ukiah, CA 95482
Civic Center
300 Seminary Ave.
Ukiah, CA 95482
To coordinate activities and policy development with the
County's 2nd District Supervisor Brown Shannon Riley, Deputy City Manager;
467-5793 sriley@cityofukiah.com
LOCAL/COUNTY/REGIONAL/LIASONS
OnGoing One or Two Council and/or
Staff
MTG DATE/TIME LOCATION MAILING ADDRESS/CONTACT COMMITTEE FUNCTION ASSIGNED TO PRINCIPAL STAFF SUPPORT
Fire Executive Committee 2nd Wednesdays of
month, 3:45 p.m.
Ukiah Valley Conference Center,
200 S. School Street
Ukiah, CA
Stephanie Abba
Civic Center
300 Seminary Ave.
Ukiah, CA 95482
sabba@cityofukiah.com
Per the recently adopted agreement between the City of
Ukiah and the Ukiah Valley Fire Protection District Orozco/Brown
Doug Hutchison, Fire Chief; 463-6263;
dhutchison@cityofukiah.com
STANDING COMMITTEES MTG DATE/TIME LOCATION MAILING ADDRESS/CONTACT COMMITTEE FUNCTION ASSIGNED TO PRINCIPAL STAFF SUPPORT
Equity and Diversity TBD Virtual Meeting Room
(link to be created)
Civic Center
300 Seminary Ave.
Ukiah, CA 95482
Improve diversity and equity in the City’s workforce and
municipal services Orozco/Duenas Traci Boyl, City Manager's Office Management
Analyst; 467-5720 tboyl@cityofukiah.com
2 9/8/2022
Page 370 of 390
COMMITTEE ASSIGNED TO PRINCIPAL STAFF SUPPORT
Electric Grid Operational Improvements Crane/Orozco Cindy Sauers, Electric Utility Director;
463-629586 csauers@cityofukiah.com
Trench Cut Policy Development Crane/Brown Tim Eriksen, Public Works Director/City Engineer;
463-6280 teriksen@cityofukiah.com
Budget Development Best Practices and
Financial Policy For FY 22/23 Budget Crane/Brown
Dan Buffalo, Director of Finance;
463-6220 dbuffalo@cityofukiah.com
Sheri Mannion, Human Resource Director/Risk
Manager; 463-6272, smannion@cityofukiah.com
Advance Planning & Policy for Sphere of
Influence (SOI), Municipal Service Review (MSR),
Annexation, Tax Sharing, Detachment, and Out
of Area Service Agreements
Crane/Rodin
Sage Sangiacomo, City Manager
463-6221 ssangiacomo@cityofukiah.com
Shannon Riley, Deputy City Manager
467-5793 sriley@cityofukiah.com
Craig Schlatter, Community Development Director
463-6219 cschlatter@cityofukiah.com
Sean White, Director of Water Resources;
463-5712 swhite@cityofukiah.com
Tim Eriksen, Public Works Director/City Engineer;
463-6280 teriksen@cityofukiah.com
Cindy Sauers, Electric Utility Director;
463-629586 csauers@cityofukiah.com
Dan Buffalo, Director of Finance; 463-6220
dbuffalo@cityofukiah.com
2021 Electric Rate Study Crane/Duenas Cindy Sauers, Electric Utility Director;
463‐6286 csauers@cityofukiah.com
Housing Policy Rodin/Orozco Craig Schlatter, Community Development Director
463-6219 cschlatter@cityofukiah.com
UVSD/ City Relations
Ad hoc committee to address specific issues with the
Ukiah Valley Sanitation District, including discussion of
overall sewer system service delivery policies, operating
policy revisions, potential revisions to the current
Operating Agreement, and cost sharing
Crane/Brown
Dan Buffalo, Director of Finance;
463‐6220 dbuffalo@cityofukiah.com
Sean White, Water Resources Director
463‐5712 swhite@cityofukiah.com
Upper Russian River Water Agency/City
Relations Crane/Brown Sean White, Director of Water Resources;
463‐5712 swhite@cityofukiah.com
Orr Street Bridge Corridor Rodin/Duenas Tim Eriksen, Public Works Director/City Engineer;
463-6280 teriksen@cityofukiah.com
Complete Streets Rodin/Crane
Tim Eriksen, Public Works Director/City Engineer;
463-6280 teriksen@cityofukiah.com
Shannon Riley, Deputy City Manager
467-5793 sriley@cityofukiah.com
Neil Davis, Community Services Director
467-5764 ndavis@cityofukiah.com
Cannabis Ordinance Modifications Duenas/Brown Craig Schlatter, Community Development Director
463‐6219 cschlatter@cityofukiah.com
Special Districts Brown/Crane Shannon Riley, Deputy City Manager
467‐5793 sriley@cityofukiah.com
Public Financing Rodin/Orozco Dan Buffalo, Director of Finance;
463‐6220 dbuffalo@cityofukiah.com
Corp Yard Crane/Brown Jason Benson, Senior Civil Engineer
463‐6284 jbenson@cityofukiah.com
Police Chief Recruitment Brown/Rodin Shannon Riley, Deputy City Manager
467‐5793 sriley@cityofukiah.com
Great Redwood Trail Rodin/Duenas Neil Davis, Community Services Director
467‐5764 ndavis@cityofukiah.com
City Manager Review Rodin/Brown
Sheri Mannion, Human Resources Director
463‐6244 smannion@cityofukiah.com
2022 AD HOC COMMITTEES
3 10/6/2022
Page 371 of 390
Page 1 of 18
Joint Powers Agreement Forming the Ukiah Valley Basin Groundwater
Sustainability Agency
This Joint Powers Agreement (“Agreement”) is made and entered into by and among the Russian
River Flood Control and Water Conservation Improvement District (“RRFC”), and the Upper
Russian River Water Agency, both of which are California special districts, the City of Ukiah, a
municipal corporation, and the County of Mendocino, a political subdivision of the State of
California, which are together referred to herein individually as “Member” and collectively as
“Members,” for the purposes of forming a joint powers agency, to be known as the Ukiah Valley
Basin Groundwater Sustainability Agency, to serve as the Groundwater Sustainability Agency in
the Ukiah Valley basin.
Recitals
A. Each of the Members is a local agency, as defined by the Sustainable
Groundwater Management Act of 2014 (Division 2, Part 2.74 (commencing with §10720), Part 5
(commencing with Section4999), Part 5.1 (commencing with Section5100) and Part 5.2
(commencing with Section5200) of the California Water Code Section et seq.; “SGMA”), duly
organized and existing under, and by virtue, of the laws of the State of California, and each
Member has water supply, water management or land use responsibilities within the Ukiah
Valley.
B. SGMA seeks to provide sustainable management of groundwater basins, enhance
local management of groundwater, establish minimum standards for sustainable groundwater
management, and provide local groundwater agencies with the authority and the technical and
financial assistance necessary to sustainably manage groundwater.
C. Section 10720.7 of SGMA requires all basins designated as high or medium
priority basins by the Department of Water Resources (“DWR”) in its Bulletin 118 be managed
under groundwater sustainability plans, or coordinated groundwater sustainability, plans
pursuant to SGMA.
D. The Ukiah Valley basin (designated basin number 1-52 in Bulletin 118; the
“Basin”) is designated as a medium-priority basin.
E. The Members have determined that the sustainable management of the Basin
pursuant to SGMA may best be achieved through the cooperation of the Members operating
through a joint powers agency.
F. The Joint Exercise of Powers Act (Chapter 5 (commencing with § 6500) of
Division 7, of Title 1 of the California Government Code; the “Act”), authorizes two or more
public agencies to, by agreement, jointly exercise any power held in common by agencies
entering into such an Agreement and to exercise additional powers granted under the Act.
G. Based on the foregoing legal authority, the Members desire to create a joint
powers agency for the purpose of taking all actions deemed necessary by the joint powers agency
to ensure sustainable management of the Basin, as required by SGMA.
ATTACHMENT 2
Page 372 of 390
Page 2 of 18
H. The governing board of each Member has determined it to be in the Member’s
and in the public’s best interest that this Agreement be executed.
Terms of Agreement
Article 1. Definitions
As used in this Agreement, unless context requires otherwise, the meanings of the terms set forth
below shall be as follows:
1.1. “Act” means the Joint Exercise of Powers Act, set forth in Chapter 5 of Division
7of Title 1 of the Government Code, sections 6500, et seq., including all laws supplemental
thereto.
1.2. “Agency” means the Ukiah Valley Basin Groundwater Sustainability Agency.
1.3. “Agreement” means this joint powers agreement, which creates the Ukiah Valley
Basin Groundwater Sustainability Agency.
1.4. “Basin” means the Ukiah Valley basin, as shown on the map attached as Exhibit
A, which is incorporated herein by this reference.
1.5. “Board of Directors” or “Board” means the governing body of the Agency as
established by Article 7 of this Agreement.
1.6. “Board Member” or “Director” shall mean a member of the Agency’s Board of
Directors.
1.7. “Committee” shall mean any committee established pursuant to Article Twelve
(12) of this Agreement.
1.8. “Effective Date” means the date on which the last Member executes this
Agreement.
1.9. “Fiscal Year” means July 1 through June 30.
1.10. “GSA” shall mean a groundwater sustainability agency.
1.11. “GSP” shall mean a groundwater sustainability plan.
1.12. “Member” has the meaning assigned to it in the Preamble and further means each
party to this Agreement that satisfies the requirements of Section 6.1 of this Agreement,
including any new members, as may be authorized by the Board pursuant to Section 6.2 of this
Agreement.
1.13. “Member Director” means a director or alternate director appointed by a Member
pursuant to Article 7 of this Agreement.
Page 373 of 390
Page 3 of 18
1.14. “Member’s Governing Body” means the board of directors or other voting body
that controls the individual public agencies that are Members.
1.15. “RRFC” has the meaning assigned to it in the Preamble of this Agreement.
1.16. “SGMA” has the meaning assigned to it in Recital A.
1.17. “Special Project” means a project undertaken by some, but not all Members of th e
Agency, pursuant to Article 14 of this Agreement.
1.18. “Stakeholder Director” means a Director appointed pursuant to Article 6 that
represents stakeholder interests.
1.19. “State” means the State of California.
Article 2. Creation of a Separate Entity
2.1. Upon the effective date of this Agreement, Ukiah Valley Basin Groundwater
Sustainability Agency (“Agency”) is hereby created. Pursuant to the provisions of the Act, the
Agency shall be a public agency separate from its members. The principal office shall be
provided for in the Bylaws.
2.2. The boundaries of the Agency shall be as shown on the map on Exhibit A,
attached and incorporated herein by this reference. The boundary shown on Exhibit A is an
updated version of the Bulletin 118 boundary, based on the 2005 Larsen and Kelsey Map
approved by the Department of Water Resources on January 26, 2017.
Article 3. Term
3.1. This Agreement shall become effective upon execution by each of the Parties and
shall continue in full force and effect until terminated pursuant to the provisions of Article 17.
Article 4. Purpose of the Agency and this Agreement
4.1. The purpose of this Agreement is to create a joint powers agency separate from its
Members that will elect to be the GSA for the entire Basin. The purpose of the Agency is to (a)
develop, adopt, and implement a GSP for the Basin in order to implement SGMA requirements
and achieve the sustainably goals outlined in SGMA; and (b) involve the public and area
stakeholders through outreach and engagement in developing and implementing the Ukiah
Valley Basin Groundwater Sustainability Plan.
Page 374 of 390
Page 4 of 18
Article 5. Powers of the Agency
5.1. Restrictions on Exercise of Powers. For purposes of Government Code Section
6509, the powers of the Agency shall be exercised subject to the restrictions upon the manner of
exercising such powers as are imposed on the County of Mendocino, and in the event of the
withdrawal of the County of Mendocino as a Member under this Agreement, then the powers of
the Agency shall be exercised subject to the restrictions upon the manner of exercising such
powers as are imposed on the City of Ukiah.
5.2. Powers. Subject to the limitations addressed herein, the Agency shall have the
power in its own name to exercise any and all common powers of the Members reasonably
related to the purposes of the Agency, including but not limited to, the following powers,
together with such other powers as are expressly set forth in the Act and SGMA:
5.2.1. To exercise all powers afforded to a GSA pursuant to, and as permitted by,
SGMA upon electing in accordance with SGMA to become the GSA for the Ukiah Valley Basin.
5.2.2. To develop, adopt and implement a GSP for the Basin pursuant to SGMA.
5.2.3. To adopt rules, regulations, policies, bylaws and procedures governing the
operation of the Agency; and adoption and implementation of a GSP for the Basin.
5.2.4. To obtain rights, permits and other authorizations for, or pertaining to,
implementation of a GSP for the Basin; and to exercise the common powers of the Members, as
directed by the Board, in developing and implementing a GSP for the Basin.
5.2.5. To perform other ancillary tasks relating to the operation of the Agency
pursuant to SGMA, including, without limitation, environmental review, engineering and design.
5.2.6. To employ, designate or otherwise contract for the services of agents,
officers, employees, attorneys, engineers, planners, financial consultants, advisors, independent
contractors, technical specialists and other consultants.
5.2.7. To make and enter into contracts necessary to the full exercise of the
Agency’s power.
5.2.8. To investigate legislation and proposed legislation affecting the Basin and
to make appearances regarding such matters.
5.2.9. To acquire property and other assets by grant, lease, purchase, bequest,
devise, gift or eminent domain; and to hold, enjoy, lease, sell, or otherwise dispose of property,
including real property, water rights and personal property, necessary for the full exercise of the
Agency’s powers.
5.2.10. To cooperate, act in conjunction and contract with the United States, the
State of California, or any agency thereof, counties, municipalities, public and private
corporations of any kind (including, without limitation, investor-owned utilities), and
individuals, or any of them, for any and all purposes necessary or convenient for the full exercise
of the powers of the Agency.
Page 375 of 390
Page 5 of 18
5.2.11. To incur debts, obligations, and liabilities; to issue bonds, notes,
certificates of participation, guarantees, equipment leases, reimbursement obligations and other
indebtedness, and, to the extent provided for in a duly adopted Agency, to impose assessments,
groundwater extraction fees or other charges, and other means of financing the Agency as
authorized by Chapter 8 of SGMA (commencing at Section 10730 of the Water Code).
5.2.12. To apply for, accept, and receive contributions, grants or loans from any
public or private agency or individual in the United States, or any department, instrumentality, or
agency thereof for the purpose of financing the Agency’s activities.
5.2.13. Invest money that is not needed for immediate necessities, as the Board of
Directors determines advisable, in the same manner and upon the same conditions as other local
entities in accordance with Section 53601 of the California Government Code, as that section
now exists, or may hereafter be amended.
5.2.14. Reimburse Board Members for the actual amounts of reasonable and
necessary expenses incurred in attending the Agency’s meetings or any committee of the Agency
in performing the duties of their officer, subject to Board of Directors policy and budget
authorization.
5.2.15. To sue and be sued in the Agency’s own name; provided that a Member
may determine not to contribute to the expenses of litigation initiated by the Agency.
5.2.16. To provide for the prosecution of, defense of, or other participation in
actions or proceedings at law or in public hearings in which the Members, pursuant to this
Agreement, may have an interest; and may employ counsel and other expert assistance for these
purposes.
5.2.17. To exercise the common powers of its Members to develop, collect,
provide and disseminate information that furthers the purposes of the Agency, including, but not
limited to the operation of the Agency and adoption and implementation of a Groundwater
Sustainability Plan for the Basin, to the Members’ legislative, administrative, and judicial bodies,
as well as the public generally.
5.2.18. Employ or retain a full time or part time supporting staff.
5.2.19. To perform all other acts necessary or proper to fully carry out the
purposes of this Agreement.
5.3. The Agency and all of its Members confirm that nothing contained herein shall
grant the Agency any power to alter any water right, contract right, or any similar right held by
its Members, or amend a Member’s water delivery practice, course of dealing, or conduct
without the express consent of the holder thereof.
Article 6. Membership
6.1. Initial Members. The initial Members of the Agency shall be the County of
Mendocino, City of Ukiah, Russian River Flood Control and Water Conservation Improvement
District, and the Upper Russian River Water Agency.
Page 376 of 390
Page 6 of 18
6.2. New Members. Additional Parties may join the Agency and become a Member
provided that the prospective new member: (a) is eligible to join a GSA as provided by SGMA,
(b) possesses powers common to all other Members, and (c) receives unanimous consent of the
existing Members, evidenced by the execution of a written amendment to this Agreement signed
by all Members, including the additional public agency. Additional Stakeholders Directors may
be created by the execution of a written amendment to this Agreement signed by all Members.
Article 7. Agency Board of Directors
7.1. Formation of the Board of Directors. The Agency shall be governed by a Board
of Directors (“Board of Directors” or “Board”). The Board shall be composed of six (6)
Directors consisting of the following representatives, who shall be appointed in the manner set
forth in Section 7:
7.1.1. One (1) representative appointed by the governing board of each Member,
who shall be a member of the governing board of the Member (each, a “Member Director”).
7.1.2. Two (2) Stakeholder Directors, one (1) of which shall be representative of
agricultural stakeholders and interests within the Basin; and one (1) of which shall be
representative of tribal stakeholders and interests within the Basin. The two (2) Stakeholder
Directors shall meet the following qualifications: ¶
(a) One (1) Agricultural Stakeholder Director. The Agricultural
Stakeholder Director shall meet the following criteria, determined at the sole discretion of the
Board Members: (1) be a resident of Mendocino County; (2.a) own/ lease real property in active
commercial agricultural production overlying the Basin or (2.b) be an employee of a commercial
agricultural production operation overlying the basin involved with water use decisions and (3)
extract groundwater from the Basin for the irrigation/frost protection of at least fifteen (15) acres
of agricultural crops in commercial operation. The Agricultural Stakeholder may not be a party
to any pending litigation against the Agency or any of its Members.
(b) One (1) Tribal Stakeholder Director shall be appointed by the six
tribes exercising jurisdiction over Indian lands within the Ukiah Valley Basin identified as
Redwood Valley Rancheria, Coyote Valley Reservation, Pinoleville Pomo Nation, Potter Valley
Rancheria, Guidiville Rancheria and the Hopland Reservation.
7.1.3. Relationship of Members. The Upper Russian River Water Agency is a
joint powers authority consisting of several water districts within the Ukiah Valley and the
RRFC. For purposes of the Agency, the RRFC desires to be a separate member of the Agency
with a separate vote, and as such, will not take part in any action or dis cussion, and shall not vote
on any item of the Upper Russian River Water Agency related to the Agency. The abstention of
the RRFC from such agenda items of the Upper Russian River Water Agency shall be separately
reflected in documents of the Upper Russian River Water Agency. Should the RRFC fail to
abstain from taking part in any vote relating to the Agency before the Upper Russian River
Water Agency, it shall not be entitled to vote on that matter when it comes before the Agency.
Members of the Upper Russian River Agency are also contemplating the
consolidation of all members of the joint powers authority into a single water district. Should
such consolidation occur, this JPA shall be amended to reflect the consolidation of members.
Page 377 of 390
Page 7 of 18
7.2. Duties of the Board of Directors. The business and affairs of the Agency, and all
of the powers of the Agency, including without limitation all powers set forth in Article 5, are
reserved to and shall be exercised by and through the Board of Directors, except as may be
expressly delegated to the Executive Director or others pursuant to this Agreement, Bylaws, or
by specific action of the Board of Directors.
7.3. Appointment of Directors. The Directors shall be appointed as follows:
7.3.1. Member Directors. Each Member Director must sit on the governing
board of the Member and be appointed by that governing board by Resolution, which Resolution
shall be transmitted to the Secretary of the Agency following adoption by the Member.
7.3.2. Stakeholder Directors. The two (2) Stakeholder Directors shall be
appointed as follows:
(a) One (1) stakeholder shall be chosen by the Member Directors to
represent agricultural interests within the Ukiah Valley Groundwater Basin. This stakeholder
shall meet the qualifications as described in 7.1.2. (a). This stakeholder shall be selected from a
list of three (3) nominations submitted from the Mendocino County Farm Bureau, but the three
(3) nominees need not be a member of the organization. Nominees shall be submitted to the
Member Directors pursuant to a process specified in the Bylaws, unless directed otherwise by the
Member Directors. The Member Directors shall consider the nominees at a regular meeting of
the Board and shall appoint the Agricultural Stakeholder Director upon simple majority vote of
all Member Directors.
(b) Tribal Stakeholder Director. The Member Directors shall confirm
the nomination for the Tribal Stakeholder Director submitted by the six (6) Tribes within the
Ukiah Valley. The Member Directors shall confirm the nominee at a regular meeting and shall
appoint the Tribal Stakeholder Director upon simple majority vote of all Member Directors.
7.4. Alternate Directors. Each Member may also appoint one (1) Alternate Director to
the Board of Directors, and an Alternate Director shall be appointed for each Stakeholder
Director. All Alternate Directors shall be appointed in the same manner as set forth in Section
7.3. Alternate Directors shall have no vote, and shall not participate in any discussions or
deliberations of the Board unless appearing as a substitute for a Director due to absence or
conflict of interest. If the Director is not present, or if the Director has a conflict of interest
which precludes participation by the Director in any decision-making process of the Board, the
Alternate Director appointed to act in his/her place shall assume all rights of the Director, and
shall have the authority to act in his/her absence, including casting votes on matters before the
Board. Each Alternate Director shall be appointed prior to the third meeting of the Board.
Alternate Directors are encouraged to attend all Board meetings and stay informed on current
issues before the Board. Alternate Board Members have no vote at Board of Director meetings if
the Board Member is present. If the Board Member is not present, the Alternate Board Member
shall be entitled to participate in all respects as a regular Board Member.
Page 378 of 390
Page 8 of 18
7.5. Terms of Office. The term of office for each member of the Agency’s Board of
Directors is two (2) years. Each member of the Board of Directors shall serve at the pleasure of
the appointing Member and may be removed from the Board of Directors by the appointing
members at any time. If at any time a vacancy occurs on the Board of Directors, a replacement
shall be appointed to fill the unexpired term of the previous Board Member, pursuant to Article 7
and within ninety (90) days of the date that such position becomes vacant.
7.6. Removal of Board Members. Board Members and Alternate Board Members shall
serve at the pleasure of their appointing Member’s governing board and may be removed or
replaced at any time. A Board Member that no longer meets the qualifications set forth in section
7.1 is automatically removed from the Agency Board of Directors. Upon removal of a Board
Member, the Alternate Board Member shall serve as a Board Member until a new Board
Member is appointed by the Member. Members must submit any changes in Board Member or
Alternate Board Member positions to the Secretary in writing and signed by the Member. A
Stakeholder Director may be removed or reappointed by a simple majority vote of all Member
Directors.
7.7. Vacancies. A vacancy on the Board of Directors shall occur when a Director
resigns or reaches the end of that Director’s term, as set forth in Section 7.5. For Member
Directors, a vacancy shall also occur when he/she is removed by his/her appointing Member. For
Stakeholder Directors, a vacancy shall also occur when the Stakeholder Director is removed, as
set forth in Section 7.5. Upon the vacancy of a Member Director, the Alternate Director shall
serve as Director until a new Director is appointed, as set forth in Section 7.3, unless the
Alternate Director is already serving as a Member Director in the event of a prior vacancy, in
which case, the seat shall remain vacant until a replacement Director is appointed as set forth in
Section 7.3. Members shall submit any changes in Director or Alternate Director positions to the
Board of Directors or Executive Director by written notice, signed by an authorized
representative of the Member. The written notice shall include a Resolution of the governing
board of the Member directing such change in the Director or Alternative Director position.
7.8. Adjustment to Composition of the Board of Directors. Should the circumstances
change in the future, any person or entity may petition the Members hereto to amend this
Agreement so as to add or delete representatives to the Governing Board to accurately reflect
groundwater production within the boundaries of the authority.
Article 8. Agency Meetings
8.1. Initial Meeting. The initial meeting of the Agency’s Board of Directors shall be
called by the County of Mendocino and held in the Mendocino County Board of Supervisors
Chambers, 501 Low Gap Road, Ukiah, California within 60 days of the effective date of this
Agreement. All Members shall be required to attend the initial meeting.
8.2. Time and Place. The Board of Directors shall provide in its adopted bylaws or by
other means authorized or required by law, for the time and place for holding regular meetings,
at least quarterly, and at such other times as determined by the Board of Directors.
Page 379 of 390
Page 9 of 18
8.3. Conduct. All meetings of the Governing Board shall be noticed, held, and
conducted in accordance with the Ralph. M. Brown Act to the extent applicable. Board Members
and Alternate Board Members may use teleconferencing in connection with any meeting in
conformance with and to the extent authorized by the applicable laws.
8.4. Local Conflict of Interest Code. The Board of Directors shall adopt a local
conflict of interest code pursuant to the provisions of the Political Reform Act of 1974
(Government Code sections 81000, et seq.).
Article 9. Board of Directors Voting
9.1. Quorum. A majority of the members of the Board of Directors shall constitute a
quorum for purposes of transacting business, except less than a quorum may vote to adjourn a
meeting.
9.2. Director Votes. Each member of the Board of Directors of the Agency shall have
one (1) vote. Except as otherwise specified in this Agreement, all affirmative decisions of the
Board of Directors shall require the affirmative vote of a simple majority of all Directors
participating in voting on a matter of Agency business; provided that if a Director is disqualified
from voting on a matter before the Board because of a conflict of interest, that Director shall be
excluded from the calculation of the total number of Directors that constitute a majority. The
Board of Directors shall strive for consensus of all members on items.
9.3. Voting on Fiscal Items. Fiscal items, approval of the annual budget of the Agency
and any expenditures, and any projects shall require an affirmative vote by a majority of the
Board of Directors.
Article 10. Officers
10.1. Officers. The Board of Directors shall select a Chairman, Vice-Chairman,
Secretary, and any other officers as determined necessary by the Board of Directors.
10.1.1. The Chairman shall preside at all Board Meetings.
10.1.2. The Vice-Chairman shall act in place of the Chairman at meetings should
the Chairman be absent.
10.1.3. The Secretary shall keep minutes of all meetings of the Board of Directors
and shall, as soon as possible after each meeting, forward a copy of the minutes to each member
and alternate of the Board of Directors.
10.1.4. All Officers shall be chosen at the first Board of Directors meeting and
serve a term for two (2) years. An Officer may serve for multiple consecutive terms. Any Officer
may resign at any time upon written notice to the Agency.
Page 380 of 390
Page 10 of 18
Article 11. Committee Formation
11.1. Internal Committee Formation. There shall be established such internal
committees as the Board of Directors shall determine from time to time. Each such internal
committee shall be comprised of two (2) Directors, shall exist for the term specified in the action
establishing the committee, shall meet as directed by the Board of Directors, and shall make
recommendations to the Board of Directors on the various activities of the Agency.
11.2. External Advisory Committee Formation. The Board of Directors may establish,
as deemed necessary, one or more advisory committees comprised of diverse social, cultural, and
economic elements of the population and area stakeholders within the Ukiah Valley Basin. The
Board of Directors shall encourage the active involvement of the advisory committee(s) prior to
and during the development and implementation of the Groundwater Sustainability Plan. The
Board of Directors will ensure that at least one (1) member from the Board of Directors or
Agency employee attends and participates in each advisory committee meeting.
11.3. Technical Advisory Committee. There shall be established a technical advisory
committee, the purpose of which shall be to provide advice to the Board of Directors on issues of
a technical nature related to the activities of the Agency. The technical advisory committee shall
be comprised of at least one (1) representative of each Member; one (1) representative for each
of the Agricultural Stakeholders and the Tribal Stakeholders; at least one (1) representative from
the Sonoma County Water Agency; and at least one (1) representative from the Mendocino
County Resource Conservation District. The technical advisory committee shall meet as directed
by the Board of Directors, and shall make recommendations to the Board of Directors as
requested. The role and responsibilities of the technical advisory committee will be established
in a Memorandum of Understanding between the Agency, the Mendocino County Resource
Conservation District, and the Sonoma County Water Agency.
Article 12. Treasurer, Controller, and Legal Counsel
12.1. Treasurer and Controller. The County of Mendocino shall act as Treasurer and
Controller for the Agency. The Controller of the Agency shall cause an independent audit of the
Agency’s finances to be made by a certified public accountant in compliance with California
Government Code Section 6505. The Treasurer of the Agency shall be the depositor and shall
have custody of all money of the Agency from whatever source. The Controller of the Agency
shall draw warrants and pay demands against the Agency when the demands have been approved
by the Agency, or any authorized representative pursuant to any delegation of Agency adopted
by the Agency. The Treasurer and Controller shall comply strictly with the provisions of statutes
relating to their duties found in Chapter 5 (commencing with Section 6500) of Division 7 of Title
1 of the California Government Code.
12.2. Legal Counsel. The Board of Directors may appoint legal counsel as it deems
appropriate.
Article 13. Executive Director
13.1. Appointment. The Board of Directors may hire an Executive Director who shall
be compensated for his or her services, as determined by the Board of Directors. The Executive
Director may, though need not be, an officer, employee or representative of one of the Members.
Page 381 of 390
Page 11 of 18
13.2. Duties. The Executive Director shall be the Chief Administrative Officer of the
Agency, shall serve at the pleasure of the Board of Directors, and shall be responsible to the
Board of Directors for the proper and efficient administration of the Agency. The Execut ive
Director shall have the powers designated in the Bylaws.
13.3. Term and Termination. The Executive Director shall serve until he/she resigns or
the Board of Directors terminates his/her appointment.
13.4. Staff. The Executive Director may employ such additional full-time and or part-
time employees, assistants, and independent contractors that may be necessary from time to time
to accomplish the purposes of the Agency, subject to approval of the Board of Directors. The
Agency may contract with a Member or other public agency or private entity for various
services, including without limitation, those related to the Agency’s finances, purchasing, risk
management, information technology, human resources and other technical and non-technical
staff assistance as may be required. A written Agreement shall be entered between the Agency
and the Member or other public agency or private entity contracting to provide such service, and
that Agreement shall specify the terms on which such services shall be provided, including
without limitation, the compensation, if any, that shall be made for the provision of such
services.
Article 14. Specific Projects
14.1. Projects. The Agency intends to carry out activities in furtherance of its purposes
and consistent with the powers established by the Agreement with the participation of all
Members.
14.2. Member Specific Projects. In addition to the general activities undertaken by all
Members of the Agency, the Agency may initiate specific projects or litigation that involves less
than all Members. No Member shall be required to be involved in a project that involves less
than all the Members.
14.3. Project Agreement. Prior to undertaking any project or litigation that does not
involve all Member Agencies, the Members electing to participate in the project shall enter into a
Project Agreement. A Member may elect not to participate in a specific project or litigation
matter by providing notice and not entering into the Project Agreement specific to the matter in
which the Member has elected not to participate. Each Project Agreement shall provide the terms
and conditions by which the Members that enter into the Project Agreement will participate in
the project. All assets, rights, benefits, and obligations attributable to the Project shall be assets,
rights, benefits, and obligations of those Members which have entered into the Project
Agreement. Any debts, liabilities, obligations, or indebtedness incurred by the Agency in regard
to a particular Project shall be the debts, liabilities, obligations, and indebtedness of those
Members who have executed the Project Agreement in accordance with the terms thereof and
shall not be the debts, liabilities, obligations, and indebtedness of those Members who have not
executed the Project Agreement. Further, to the extent the Project is litigation, the Members who
have not entered into the Project Agreement shall not be named or otherwise listed i n the
pleadings and/or appear on litigation materials.
Page 382 of 390
Page 12 of 18
14.4. Board of Directors Approval. The Board of Directors shall have the authority to
disapprove any Project Agreement upon a determination that the Project Agreement has specific,
substantial adverse impacts upon Members that have not executed the Project Agreement.
Article 15. Budget and Expenses
15.1. Budgets. Within ninety (90) days after the first meeting of the Governing Board
of the Agency, and thereafter prior to the commencement of each fiscal year, the Board of
Directors shall adopt a budget for the Agency for the ensuing fiscal year.
15.2. Agency Funding and Contributions. In order to provide the needed capital to
initially fund the Agency, the Agency shall be initially funded by a contribution from initial
Members in the amount established in the bylaws, which contribution shall be set at an equal
dollar amount for initial Members. In subsequent years, the Agency may be funded through
additional voluntary contributions by all Members, and as otherwise provided in Chapter 8 of
SGMA (commencing with Section 10730 of the Water Code).
Article 16. Liability and Indemnification
16.1. Liability. The Members do not intend hereby to be obligated either jointly or
severally for the debts, liabilities or obligations of the Agency, except as may be specifically
provided for in California Government Code Section 895.2, as amended or supplemented.
Therefore unless and to the extent otherwise required by law or agreed to herein by the
Members, in accordance with California Government Code Section 6507, the debts, liabilities
and obligations of the Agency shall not be the debts, liabilities or obligations of the Member
entities. The Agency shall own and hold title to all funds, property and works acquired by it
during the term of this Agreement.
16.2. Indemnification. Funds of the Agency may be used to defend, indemnify, and
hold harmless the Agency, each Member, each Director, and any officers, agents and employees
of the Agency for their actions taken within the course and scope of their duties while acting on
behalf of the Agency. Other than for gross negligence or intentional acts, to the fullest extent
permitted by law, the Agency agrees to save, indemnify, defend and hold harmless each Member
from any liability, claims, suits, actions, arbitration proceedings, administrative proceedings,
regulatory proceedings, losses, expenses or costs of any kind, whether actual, alleged or
threatened, including attorney’s fees and costs, court costs, interest, defense costs, and expert
witness fees, where the same arise out of, or are in any way attributable in whole or in part to,
negligent acts or omissions of the Agency or its employees, officers or agents or the employees,
officers or agents of any Member, while acting within the course and scope of a Member
relationship with the Agency.
Article 17. Withdrawal and Termination
17.1. Withdrawal. A Member may unilaterally withdraw from this Agreement without
causing or requiring termination of this Agreement, effective upon sixty (60) days written notice
to the remaining Members.
Page 383 of 390
Page 13 of 18
17.2. Termination of Agency. This Agreement may be rescinded and the Agency
terminated by unanimous written consent of all Members, except during the outstanding term of
any Agency indebtedness.
17.3. Effect of Withdrawal or Termination. Upon termination of this Agreement or
unilateral withdrawal, a Member shall remain obligated to pay its share of all debts, liabilities
and obligations of the Agency required of the Member pursuant to the terms of this Agreement
which were incurred or accrued prior to the date of such termination or withdrawal, including
without limitation, those debts, liabilities and obligations pursuant to Section 5.2.11. Any
Member that withdraws from the Agency shall have no right to participate in the business and
affairs of the Agency, or to exercise any rights of a Member under this Agreement or the Act, but
shall continue to share in distributions from the Agency on the same basis as if such Member had
not withdrawn, provided that a Member that has withdrawn from the Agency shall not receive
distributions in excess of the contributions made to the Agency while a Member. The right to
share in distributions granted under this section shall be in lieu of any right the withdrawn
Member may have to receive a distribution or payment of the fair value of the Member’s interest
in the Agency.
17.4. Disposition of Agency Assets upon Termination.
17.4.1. Surplus Funds. Upon termination of this Agreement, any reserves or
surplus money on-hand shall be returned to the Members in the same proportion said Members
have funded such reserves or surplus, in accordance with California Government Code section
6512.
17.4.2. Agency Property. The Agency shall first offer any assets of the Agency
for sale to the Members on terms and conditions determined by the Board of Directors. If no
such sale to Members is consummated, the Board shall offer the assets of the Agency for sale to
any non-member for good and adequate consideration on terms and conditions determined by the
Board of Directors.
Article 18. Miscellaneous
18.1. No Predetermination or Irretrievable Commitment of Resources. Nothing in this
Agreement shall constitute a determination by the Agency or any of its Members that any action
shall be undertaken or that any unconditional or irretrievable commitment of resources shall be
made, until such time as the required compliance with all local, state, or federal laws, including
without limitation the California Environmental Quality Act, National Environmental Policy Act,
or permit requirements, as applicable, has been completed.
18.2. Notices. Notices hereunder shall be sufficient if delivered via electronic mail,
First-Class mail to the addresses below:
Russian River Flood Control and Water Conservation Improvement District: 151
Laws Avenue, Suite D, Ukiah, CA 95482
County of Mendocino: 501 Low Gap Road, Room 1010, Ukiah, CA 95482
City of Ukiah: 300 Seminary Avenue, Ukiah, CA 95482
Upper Russian River Water Agency: 151 Laws Avenue, Ukiah, CA 95482
Page 384 of 390
Page 14 of 18
18.3. Bylaws. At, or as soon as practicable after the first Board of Directors meeting the
Board of Directors shall draft and approve Bylaws of the Agency to govern day-to-day
operations of the Agency.
18.4. Amendment. This Agreement may be amended at any time, by mutual agreement
of the Members, provided that before any amendments shall be operative or valid, it shall be
reduced to writing and signed by all Members hereto.
18.5 Agreement Complete. This Agreement constitutes the full and complete
Agreement of the Members. This Agreement supersedes all prior Agreements and
understandings, whether in writing or oral, related to the subject matter of this Agreement that
are not set forth in writing herein.
18.6. Severability. If any provision of this Agreement is determined to be invalid or
unenforceable, the remaining provisions will remain in force and unaffected to the fullest extent
permitted by law and regulation.
18.7. Execution in Counterparts. The Parties intend to execute this Agreement in
counterparts. It is the intent of the Parties to hold one (1) counterpart with single original
signatures to evidence the Agreement and to thereafter forward three (3) other original
counterparts on a rotating basis for all signatures. Thereafter, each Member shall be delivered an
originally executed counterpart with all Member signatures.
18.8. Withdrawal by Operation of Law. Should the participation of any Member to this
Agreement be decided by the courts to be illegal or in excess of that Member’s authority or in
conflict with any law, the validity of this Agreement as to the remaining Members shall not be
affected thereby.
18.9. Assignment. The rights and duties of the Members may not be assigned or
delegated without the written consent of all other Members. Any attempt to assign or delegate
such rights or duties in contravention of this Agreement shall be null and void.
18.10. Binding on Successors. This Agreement shall inure to the benefit of, and be
binding upon, the successors or assigns of the Members.
18.11. Other Joint Power Agreements. Nothing in this Agreement shall prevent the
Members from entering into other joint exercise of power Agreements.
[Signature Pages Below]
Page 385 of 390
Page 15 of 18
IN WITNESS WHEREOF, the parties hereto execute this Agreement as of the Effective Date.
COUNTY OF MENDOCINO
By: _____________________________
JOHN MCCOWEN, Chair
BOARD OF SUPERVISORS
Date: ______________
By signing above, signatory warrants and
represents that he/she executed this
Agreement in his/her authorized capacity and
that by his/her signature on this Agreement,
he/she or the entity upon behalf of which
he/she acted, executed this Agreement
ATTEST:
CARMEL J. ANGELO, Clerk of said Board
By: ____________________________
Deputy
Date: ______________
I hereby certify that according to the provisions of
Government Code Section 25103, delivery of this
document has been made.
CARMEL J. ANGELO, Clerk of said Board
By: __________________________
Deputy
Date: ______________
COUNTY COUNSEL REVIEW:
APPROVED AS TO FORM:
KATHARINE L. ELLIOTT,
County Counsel
By:________________________________
Deputy
Date: ______________
Page 386 of 390
Page 16 of 18
IN WITNESS WHEREOF, the parties hereto execute this Agreement as of the Effective Date.
CITY OF UKIAH
BY: ____________________
Date
Jim O. Brown, MAYOR
BY: ____________________
Date
CITY MANAGER
ATTEST
____________________
CITY CLERK Date
Page 387 of 390
Page 17 of 18
IN WITNESS WHEREOF, the parties hereto execute this Agreement as of the Effective Date.
Russian River Flood Control and Water Conservation Improvement District
By: ________________________________ Date: ______________
Paul Zellman, President
Board of Trustees
Page 388 of 390
Page 18 of 18
IN WITNESS WHEREOF, the parties hereto execute this Agreement as of the Effective Date.
Upper Russian River Water Agency
By: ________________________________ Date: ______________
Jerry Cardoza, President
Board of Directors
Page 389 of 390
RESOLUTION NO. 2022-
RESOLUTION OF THE CITY COUNCIL OF THE CITY OF UKIAH APPOINTING CITY
REPRESENTATIVES TO THE UKIAH VALLEY BASIN GROUNDWATER SUSTAINABILITY
AGENCY
WHEREAS, groundwater located in the Ukiah Basin is a vital resource to meet the water supply
needs for residents, visitors and businesses of Mendocino County; and
WHEREAS, the City of Ukiah, Upper Russian River Water Agency and Russian River Flood
Control and Water Conservation Improvement District have come together to improve
management of groundwater in the Ukiah Valley Basin under a Joint Powers Agreement (JPA)
creating the Ukiah Valley Basin Groundwater Sustainability Agency (Agency); and
WHEREAS, each of the Member agencies is a local agency as defined by the Sustainable
Groundwater Management Act of 2014 (SGMA), duly organized and existing under and by
virtue of the laws of the State of California with the ability to exercise powers related to
groundwater management; and
WHEREAS, Article 7 of the JPA provides for the appointment of Directors and Alternate
Directors on the Board of Directors to serve as representatives of each Member Agency.
NOW, THEREFORE, BE IT RESOLVED that, effective upon final execution of the JPA by the
Member Agencies, the Ukiah City Council hereby appoints _______________ to serve as the
Director representing the City of Ukiah on the Board of Directors for the Ukiah Valley Basin
Groundwater Sustainability Agency;
BE IT FURTHER RESOLVED _________________is appointed as the Alternate Director to
represent the City of Ukiah on the Ukiah Valley Basin Groundwater Sustainability Agency in the
event that __________________is unable to attend a Board of Directors meeting.
PASSED AND ADOPTED this 2nd day of November, 2022, by the following roll call vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
Jim O. Brown, Mayor of the City of Ukiah
ATTEST:
Kristine Lawler, City Clerk